Sources Sought - 70FBR422Q00000031.pdf
PDF 382 KB Posted
- Attached to
- Atlanta Gate & Barrier Wedge Maintenance Federal contract opportunity
- Solicitation number
- 70FBR422Q00000031
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEE ADDENDUMIS CHECKED
CODE 18a. PAYMENT WILL BE MADE BY
CODE
FACILITYCODE
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT SUCH ADDRESS IN OFFER
OFFEROR
70FBR4
3005 CHAMBLEE TUCKER ROAD
ADMINISTRATIVE SERVICESCONTRACTING
FEDERAL EMERGENCY MANAGEMENT AGENCY
FEMA REGION 04
CODE 16. ADMINISTERED BYCODE
X
X
561621
SIZE STANDARD:
% FOR:SET ASIDE:UNRESTRICTED OR70FBR4
RFPIFB
10. THIS ACQUISITION ISCODE
RFQ
14. METHOD OF SOLICITATION
13b. RATING
NAICS:
SMALL BUSINESS
03/11/2022 1200 ET
02/28/2022
470-416-9313Nicole Joseph (No collect calls)
INFORMATION CALL:
FOR SOLICITATION 8. OFFER DUE DATE/LOCAL TIMEb. TELEPHONE NUMBER a. NAME
4. ORDER NUMBER3. AWARD/ 6. SOLICITATION
70FBR422Q00000031
5. SOLICITATION NUMBER
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS 1. REQUISITION NUMBER PAGE OF
1 33 OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, & 30
ATLANTA GA 30341
TELEPHONE NO.
17a. CONTRACTOR/
15. DELIVER TO
ATLANTA GA 30341
3005 CHAMBLEE TUCKER ROAD
ADMINISTRATIVE SERVICESCONTRACTING
FEDERAL EMERGENCY MANAGEMENT AGENCY
9. ISSUED BY
7.
2. CONTRACT NO.
EFFECTIVE DATE
$22.00
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK BELOW
ISSUE DATE
DELIVERY FOR FOB DESTINA-
TION UNLESS BLOCK IS
MARKED
11.
SEE SCHEDULE
12. DISCOUNT TERMS
THIS CONTRACT IS A
RATED ORDER UNDER
DPAS (15 CFR 700)
13a.
SERVICE-DISABLED
VETERAN-OWNED
SMALL BUSINESS
HUBZONE SMALL
BUSINESS
8(A)
FEMA REGION 04
WOMEN-OWNED SMALL BUSINESS
(WOSB) ELIGIBLE UNDER THE WOMEN-OWNED
SMALL BUSINESS PROGRAM
EDWOSB
24.
AMOUNT
23.
UNIT PRICE
22.
UNIT
21.
QUANTITY
20.
SCHEDULE OF SUPPLIES/SERVICES
19.
ITEM NO.
Sources Sought: 1 year term of gate security monthly maintenance for Region IV, Atlanta, Georgia.
1 year term - Gate security monthly maintenance, according to the attached Statement of Work.
Period of Performance to be determined based on award.
POCs:
(Use Reverse and/or Attach Additional Sheets as Necessary)
HEREIN, IS ACCEPTED AS TO ITEMS:
X
XX
DATED
Nicole L. Joseph
. YOUR OFFER ON SOLICITATION (BLOCK 5),
INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE SET FORTH
COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND DELIVER
ARE
ARE
31c. DATE SIGNED
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA
31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER)
30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER (Type or print)
ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY ADDITIONAL
SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.
27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1, 52.212-4. FAR 52.212-3 AND 52.212-5 ARE ATTACHED. ADDENDA
26. TOTAL AWARD AMOUNT (For Govt. Use Only)
OFFER
STANDARD FORM 1449 (REV. 2/2012)
Prescribed by GSA - FAR (48 CFR) 53.212
ARE NOT ATTACHED.
ARE NOT ATTACHED.
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
30b. NAME AND TITLE OF SIGNER (Type or print)
30a. SIGNATURE OF OFFEROR/CONTRACTOR
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN
25. ACCOUNTING AND APPROPRIATION DATA
29. AWARD OF CONTRACT:
REF.
2/28/2022
32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE
32c. DATE 32b. SIGNATURE OF AUTHORIZED GOVERNMENT REPRESENTATIVE
ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED:
32a. QUANTITY IN COLUMN 21 HAS BEEN
RECEIVED INSPECTED
40. PAID BY39. S/R VOUCHER NUMBER38. S/R ACCOUNT NUMBER
37. CHECK NUMBER
FINALPARTIAL
36. PAYMENT
FINALPARTIAL
35. AMOUNT VERIFIED
CORRECT FOR
34. VOUCHER NUMBER33. SHIP NUMBER
COMPLETE
32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE
42d. TOTAL CONTAINERS42c. DATE REC'D (YY/MM/DD)
42b. RECEIVED AT (Location)
42a. RECEIVED BY (Print)
41c. DATE41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER
41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT
STANDARD FORM 1449 (REV. 2/2012) BACK
24.
AMOUNT
23.
UNIT PRICE
22.
UNIT
21.
QUANTITY
20.
SCHEDULE OF SUPPLIES/SERVICES
19.
ITEM NO.
Contracting Officer: Nicole L. Joseph, Nicole.Joseph@fema.dhs.gov
Contracting Officer's Representative (COR): Chris
Temple, Christopher.Temple@fema.dhs.gov
32f. TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE
32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT REPRESENTATIVE
33 2 of
Statement of Work TITLE: Atlanta Gate & Barrier Wedge Maintenance
Requisition Number:
Whereas the purpose of this SOW is To set forth the requirements for providing monthly/quarterly/02Y maintenance of FEMA Region IV perimeter gates, gate operators and wedge barriers.
Provide detailed checklist of inspections to include a list of any abnormalities found during the inspections/maintenance of the equipment.
(Option) Provide labor rates for the repair of the Security Gates/ Operators and Wedge Barriers to include overtime rates and response times for onsite service in the event of a failure.
Now therefore, Purchaser and Vendor mutually agree as follows:
I. Project Objectives: Provide monthly/quarterly/02Y inspections and maintenance of (2) HySecurity Gate/Gate Operators at the Atlanta FEMA Region IV facility.
Provide monthly/quarterly inspections and maintenance of (2) Nasatka NSMB VIII Barrier Systems Provide monthly inspections and maintenance of (1) TyMetal Corp Manual Gate
II. Scope of Work: HySecurity Gate/Gate Operators – Monthly
1) Check Gate and hardware for damage and wear
2) Check Drive wheels for tightness and wear (Adjust as needed)
3) Check Wheel clamp spring for clamping tension (Adjust as needed)
4) Check Stop limit switches for adjustment (Adjust as needed)
5) Check Deceleration switches for adjustment (Adjust as needed)
6) Check Anchor bolts for tightness (Tighten if needed)
7) Check for Loss of Fluid (Report if needed)
HySecurity Gate/Gate Operators – 02Y (To be completed in the 1st year and every 2 years after initial replacements) *24 Month Service Requirement
1) Drain and Replace Hydraulic Fluid *
2) Replace Clock battery *
3) Replace Motor Brushes (DC Only) *
NMSB VIII Barrier System – Monthly
1) Check wedge barrier appearance. Clean/Remove any debris
2) Perform operational checks of the wedge unit, metering arm and safeties. Document any abnormalities.
3) Visual inspection of controls. Document any abnormalities found.
NMSB VIII Barrier System – Quarterly
1) Lubrication of hinge plate assembly.
2) Inspect mounting bolts to ensure that they are tight.
3) Verify prop bars are in place for safe providing safe maintenance and repairs of the barrier wedges.
TyMetal Corp Manual Gate – Monthly
1) Open and close the gate and observe its motion.
2) Adjust the guide wheels as necessary to eliminate binding.
3) Inspect all hardware, cables and paint. Document any abnormalities.
III. Equipment List: (2) HySecurity Slide Gate Operators - M#222 EX 1.7 ST
(2) Nasatka NSMB VIII Barrier Systems with metering arms.
(1) TyMetal Corp Manual Sliding Gate
IV. Timeline and Period of Performance: This SOW’s period of performance shall be determined in the Solicitation and Award documents.