About this file

This document is the April 2018 edition of the Japan Environmental Governing Standards (JEGS), which provide environmental compliance criteria and management practices for United States Department of Defense installations in Japan. The JEGS implement DoD Instruction 4715.05 and are based on the Overseas Environmental Baseline Guidance Document. The standards apply to all DoD components and were developed by comparing U.S., Japanese, and international environmental requirements and adopting the more protective criteria. Chapters address air emissions, drinking water, wastewater, hazardous materials, hazardous and solid waste, medical waste, petroleum products, pesticides, cultural and natural resources, and other environmental topics. Requirements are established for items such as incinerators, dry cleaning machines, refrigerants, motor vehicles, and stack heights.

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Please wait...

If this message is not eventually replaced by the proper contents of the document, your PDF viewer may not be able to display this type of document.

You can upgrade to the latest version of Adobe Reader for Windows®, Mac, or Linux® by visiting http://www.adobe.com/go/reader_download.

For more assistance with Adobe Reader visit http://www.adobe.com/go/acrreader.

Windows is either a registered trademark or a trademark of Microsoft Corporation in the United States and/or other countries. Mac is a trademark of Apple Inc., registered in the United States and other countries. Linux is the registered trademark of Linus Torvalds in the U.S. and other countries.

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN

COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND

DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY

ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED

29. AWARD OF CONTRACT: REF. OFFER

16. ADMINISTERED BY CODE

7. FOR SOLICITATION

INFORMATION CALL:

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, & 30

1. REQUISITION NUMBER

0079849281

2. CONTRACT NO.

SPE4A8-20-P-0102

3. AWARD/EFFECTIVE

DATE

4. ORDER NUMBER 5. SOLICITATION NUMBER 6. SOLICITATION ISSUE

DATE

a. NAME b. TELEPHONE NUMBER (No collect calls)

8. OFFER DUE DATE/

LOCAL TIME

9. ISSUED BY CODE SPE4A8

DLA AVIATION

ASC INDUSTRIAL PLANT EQUIPMENT

8000 JEFFERSON DAVIS HWY

RICHMOND VA 23297

USA

Local Admin: Kerry Bunting DKB0006 Tel: 804-279-3316 Email: Kerry.Bunting@dla.mil

10. THIS ACQUISITION IS 100UNRESTRICTED OR SET ASIDE: % FOR:

SMALL BUSINESS

HUBZONE SMALL

BUSINESS

WOMEN-OWNED SMALL BUSINESS

(WOSB) ELIGIBLE UNDER THE WOMEN-OWNED

SMALL BUSINESS PROGRAM

8 (A)

SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

NAICS: 333517

SIZE STANDARD:500

11. DELIVERY FOR FOB DESTINA-

TION UNLESS BLOCK IS

MARKED

12. DISCOUNT TERMS

Net 30 days

13a. THIS CONTRACT IS A

RATED ORDER UNDER

DPAS (15 CFR 700)

13b. RATING

DO-B9

14. METHOD OF SOLICITATION

RFQ IFB RFP

15. DELIVER TO CODE SPE4A8

SEE BLOCK 9

Criticality: C PAS : None

17a. CONTRACTOR/ CODE

OFFEROR

FACILITY

CODE

N627581CY64

Machine Tools USA, Inc.

62 Heron Harbor Way

HUDGINS VA 23076-2086

USA

TELEPHONE NO. 8047252522

18a. PAYMENT WILL BE MADE BY CODE SL4701

DEF FIN AND ACCOUNTING SVC

BSM

P O BOX 182317

COLUMBUS OH 43218-2317

USA

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT SUCH ADDRESS IN

OFFER

18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK

BELOW IS CHECKED.

19.

ITEM NO.

20.

SCHEDULE OF SUPPLIES/SERVICES

21.

QUANTITY

22.

UNIT

23.

UNIT PRICE

24.

AMOUNT

25. ACCOUNTING AND APPROPRIATION DATA

AA: 97X4930 5CBX 10110A0 001 3111 1092903812 S33189 $674740.00

26. TOTAL AWARD AMOUNT (For Govt. Use Only)

$674,740.00

27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1, 52.212-4. FAR 52.212-3 AND 52.212-5 ARE ATTACHED. ADDENDA ARE ARE NOT ATTACHED.

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED.

30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER)

30b. NAME AND TITLE OF SIGNER (Type or Print) 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER (Type or Print) 31c. DATE SIGNED

0000-00-00

SEE SCHEDULE

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

SEE SCHEDULE

STANDARD FORM 1449 (REV.

Prescribed by GSA - FAR (48 CFR) 53.212

SEE ADDENDUM

See Schedule

DATED . YOUR OFFER ON SOLICITATION (BLOCK 5),

INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE SET FORTH ,

HEREIN IS ACCEPTED AS TO ITEMS:

EDWOSB

Christy Crumpler 09/28/2020

Marianne

Typewritten text

Marianne Ross Burroughs

President

25 SEPT 2020

DEPARTMENT OF DEFENSE

JAPAN ENVIRONMENTAL

GOVERNING STANDARDS

April 2018

ISSUED BY

HEADQUARTERS, U.S. FORCES JAPAN

April 2018 Japan Environmental Governing Standards

Executive Summary i

EXECUTIVE SUMMARY

The Under Secretary of Defense for Acquisition, Technology, and Logistics (USD(AT&L)) has appointed COMUSFJ as the DoD Lead Environmental Component (LEC) in Japan. One responsibility of the DoD LEC is to develop and maintain the Final Governing Standards (FGS) for their Area of Responsibility.

The FGS for Japan are known as the Japan Environmental Governing Standards (JEGS). The JEGS were developed in accordance with DoD Instruction 4715.05, Incorporating Change 1, October 5, 2017 (“Environmental Compliance at Installations Outside the United States”), the Status of Forces Agreement, and other applicable international agreements. The JEGS are based upon the format and standards of DoD 4715.05-G, “Overseas Environmental Baseline Guidance Document” (OEBGD). Service Components will need to develop instructions for their own management practices.

The completion of the JEGS was the result of teamwork by USFJ Service Components, installations, and other pertinent organizations within USFJ’s Area of Responsibility. The JEGS is the primary source for environmental guidance and standards for US Forces in Japan.

The 2018 JEGS are an update of the 2016 JEGS which were published in April of the same year.

The JEGS does not address environmental contamination or abatement standards, as these issues are fully covered under DoD Instruction 4715.08, Incorporating Change 1, October 10, 2017 (“Remediation of Environmental Contamination outside the United States”). Service Components shall consult the USFJ Command Engineer, on behalf of the DoD LEC, on matters regarding determinations of substantial impact to human health and safety.

Other than as provided in Chapter 8, “Medical Waste Management,” the JEGS does not address management or disposal of radioactive waste. These matters are addressed in DoD Instruction

4715.27 (“DoD Low-Level Radioactive Waste (LLRW) Disposal Program”) and service component directives.

Japan Environmental Governing Standards April 2018 ii Executive Summary

LIST OF UPDATES/REVALIDATIONS

CHANGE NUMBER DATE POSTED BY

First Issue 31-Jan-1995 Sunny Sea

Second Issue 31-May-1996 Sunny Sea

Third Issue 31-Jan-1997 Sunny Sea

Fourth Issue 31-Oct-2001 Robert Starks

Version 1.1 14-Jun-2002 Martin Westman

Fifth Issue 26-Jul-2004 Justin Lancaster

Sixth Issue 07-Sep-2006 Justin Lancaster

Seventh Issue 11-Sep-2008 Hector Jamilli

Eighth Issue 30-Nov-2010 Joseph Cook

Ninth Issue 17-Dec-2012 Sean Barron

Tenth Issue 21-Apr-2016 Sean Barron

Eleventh Issue 06-Apr-2018 Sean Barron

Table of Contents iii

Table of Contents

Executive Summary ......................................................................................................................... i

Table of Contents ........................................................................................................................... iii

C1. Chapter 1 – Overview

C1.1. Purpose

C1.2. Applicability

C1.3. Exemptions

C1.4. Definitions

C1.5. Additional Information

C1.6. Permits and Licenses

C1.7. Lead Environmental Component

C2. Chapter 2 – Air Emissions

C2.1. Scope

C2.2. Definitions

C2.3. Criteria

C3. Chapter 3 – Drinking Water

C3.1. Scope

C3.2. Definitions

C3.3. Criteria

C4. Chapter 4 – Wastewater

C4.1. Scope

C4.2. Definitions

C4.3. Criteria

C5. Chapter 5 – Hazardous Material

C5.1. Scope

C5.2. Definitions

C5.3. Criteria

C6. Chapter 6 – Hazardous Waste

C6.1. Scope

C6.2. Definitions

C6.3. Criteria iv Table of Contents

C7. Chapter 7 – Solid Waste

C7.1. Scope

C7.2. Definitions

C7.3. Criteria

C8. Chapter 8 – Medical Waste Management

C8.1. Scope

C8.2. Definitions

C8.3. Criteria

C9. Chapter 9 – Petroleum, Oil, and Lubricants

C9.1. Scope

C9.2. Definitions

C9.3. Criteria

C10. Chapter 10 – Reserved

C11. Chapter 11 – Pesticides

C11.1. Scope

C11.2. Definitions

C11.3. Criteria

C12. Chapter 12 – Historic and Cultural Resources

C12.1. Scope

C12.2. Definitions

C12.3. Criteria

C13. Chapter 13 – Natural Resources and Endangered Species

C13.1. Scope

C13.2. Definitions

C13.3. Criteria

C14. Chapter 14 – Polychlorinated Biphenyls

C14.1. Scope

C14.2. Definitions

C14.3. Criteria

C15. Chapter 15 – Asbestos

C15.1. Scope

C15.2. Definitions

C15.3. Criteria

Table of Contents v

C16. Chapter 16 – Reserved

C17. Chapter 17 – Lead-Based Paint

C17.1. Scope

C17.2. Definitions

C17.3. Criteria

C18. Chapter 18 – Spill Prevention and Response Planning

C18.1. Scope

C18.2. Definitions

C18.3. Criteria

C19. Chapter 19 – Underground Storage Tanks

C19.1. Scope

C19.2. Definitions

C19.3. Criteria

AP1. Appendix 1

AP1.1. Characteristics of Hazardous Waste

AP1.2. Lists of Hazardous Wastes

AP2. Appendix 2 – Determination of Worst Case Discharge Planning Volume vi Table of Contents

Chapter 1, Overview 1

C1. CHAPTER 1

OVERVIEW

C1.1. PURPOSE

C1.1.1. The primary purpose of these Final Governing Standards (FGS) is to provide environmental compliance criteria and management practices to be used by United States (U.S.)

Department of Defense (DoD) installations in Japan. This document implements DoD Instruction 4715.05, “Environmental Compliance at Installations Outside the United States,” Incorporating Change 1, dated 5 October 2017, and is based upon DoD 4715.05-G, “Overseas Environmental Baseline Guidance Document” (OEBGD), dated 1 May 2007.

C1.1.2. These FGS were developed by comparing and adopting the more protective criteria of the OEBGD, applicable Government of Japan (GoJ) national and prefectural environmental laws and regulations, and applicable international agreements. These FGS are consistent with the applicable provisions of Article IV of the “Agreement under Article VI of the Treaty of Mutual Cooperation and Security between the United States of America and Japan, Regarding Facilities and Areas and the Status of United States Armed Forces in Japan,” also known as the “Status of Forces Agreement (SOFA) between the United States and Japan.”

C1.2. APPLICABILITY

C1.2.1. These JEGS apply to actions of the DoD Components at all installations located within Japan.

C1.2.2. DoD activities and installations may issue supplementary criteria more protective of the environment than required by these FGS, provided they first obtain written concurrence from the DoD Lead Environmental Component. Requests for more protective criteria shall be evaluated based on their potential impact upon other activities and installations, and upon their relationship with GoJ authorities. DoD activities and installations shall clearly identify variances from these FGS in all requests for resources.

C1.2.3. DoD Components shall not enter into agreements with GoJ authorities at any level that establishes a criterion for compliance different than provided in these FGS without the prior written approval of the DoD Lead Environmental Component.

C1.3. EXEMPTIONS. These FGS do not apply to:

C1.3.1. U.S. military vessels, ships, aircraft, or space vehicles, however, the JEGS do apply to support functions for U.S. military vessels, ships, aircraft, or space vehicles provided by the DoD Components, including the management and disposal of off-loaded waste or hazardous materials.

C1.3.2. Off-installation training.

2 Chapter 1, Overview

C1.3.3. Contingency locations and associated operations and deployments, including cases of hostilities, contingency operations in hazardous areas, peacekeeping missions, or relief operations. These include U.S. forces operating as part of a multinational force not under full U.S. control.

C1.3.4. Facilities and activities associated with the Naval Nuclear Propulsion Program, in accordance with Executive Order (E.O.) 12344, and conducted pursuant to section 7158 of Title 42, United States Code.

C1.3.5. Actions to remediate environmental contamination. DoDI 4715.08 generally covers remediation.

C1.3.6. Environmental analyses conducted in accordance with E.O. 12114, “Environmental Effects Abroad of Major Federal Actions.”

C1.3.7. DoD installations that do not have the potential to affect the natural environment (e.g., activities that are primarily administrative) or where, in consultation with the Assistant Secretary of Defense for Energy, Installations, and Environment (ASD(EI&E)), the applicable Combatant Commander has determined that no significant force health protection or environmental threats exist.

C1.3.8. Activities, systems, operations and areas on DoD installations for which DoD has no authority or responsibility.

C1.4. DEFINITIONS. For purposes of these FGS, unless otherwise indicated, the following definitions apply:

C1.4.1. Existing Facility. Any facility and/or building, source, or project in use or under construction before 1 October 1994, unless it is subsequently substantially modified.

C1.4.2. New Facility. Any facility and/or building, source, or project with a construction start date on or after 1 October 1994, or a pre-existing facility that has been substantially modified since 1 October 1994.

C1.4.3. Requirements

C1.4.3.1. Particular provisions of U.S. law respecting environmental protection on DoD installations within the U.S.

C1.4.3.2. GoJ laws of general applicability, including those specifically delegated to prefectural or local governments for implementation, respecting environmental protection and which are generally applied to the Japan Self Defense Force (JSDF).

C1.4.3.3. DoD installations overseas shall use these FGS as standards for environmental compliance rather than the individual source documents that have been reconciled by the DoD Lead Environmental Component in the creation of these FGS.

Chapter 1, Overview 3

C1.4.4. Substantial Modification. Any modification to a facility and/or building the cost of which exceeds $1 million, regardless of funding source.

C1.5. ADDITIONAL INFORMATION

C1.5.1. The DoD Components shall establish and implement an environmental audit program to ensure that overseas installations assess compliance with these FGS at least once every 3 years at all major installations.

C1.5.2. DoDI 4715.23, “Integrated Recycling and Solid Waste Management,” dated October 24, 2016, implements policy, assigns responsibility, and prescribes procedures for implementation of pollution prevention programs throughout the DoD. As a matter of DoD policy, these FGS should be consulted for particular requirements that apply to activities in Japan.

Where economically advantageous and consistent with mission requirements, pollution prevention shall be the preferred means for attaining compliance with these FGS.

C1.5.3. Laboratory analyses necessary to implement these FGS shall normally be conducted in a laboratory certified by a U.S. or GoJ regulatory authority for the applicable test method. In the absence of a certified laboratory, analyses may also be conducted at a laboratory that has an established reliable record of QA compliance with standards for the applicable test method that are generally recognized by appropriate industry or scientific organizations.

C1.5.4. Unless otherwise specified, all record keeping requirements, including assessments, inspection records, logs, manifests, notices, forms, and formats, are described in accordance with DoD Manual 8910.01, Vol 1, “DoD Information Collections Manual:

Procedures for DoD Internal Information Collections,” Incorporating Change 2, April 19, 2017.

C1.5.5. These FGS do not create any rights or obligations enforceable against the U.S., the DoD, or any of its components, nor does it create any standard of care or practice for individuals. Although these FGS refer to other DoDDs and DoDIs, it is intended only to coordinate the requirements of those directives as required to implement the policies found in DoDI 4715.05. These FGS do not change other DoDDs or DoDIs or alter DoD policies.

C1.5.6. When these FGS were developed, DoD activities and installations were located in the following prefectures or special administrative areas: Aomori, Tokyo, Kanagawa, Saitama, Kyoto, Hiroshima, Shizuoka, Nagasaki, Yamaguchi, and Okinawa. If DoD activities are, or are expected to be, located in any other prefecture, the DoD Lead Environmental Component shall be contacted to determine if any changes in the FGS are warranted for that prefecture.

C1.6. PERMITS AND LICENSES

C1.6.1. In accordance with the SOFA, permits, licenses, or other forms of official approvals are not required by DoD activities and installations. Permits, licenses, or other forms of official approvals may, however, be required under GoJ law for certain contracted activities specified herein. When required, all such permits, licenses and other forms of official approval shall be obtained by the contractor from the appropriate GoJ authorities. DoD Components shall assist contractors when they are applying for a required permit, license or other form of official approval by providing necessary information only.

4 Chapter 1, Overview

C1.6.2. If the conditions of any permit, license or other form of official approval provides for a less protective standard than are prescribed in these FGS, these FGS shall remain the compliance standard unless a waiver is obtained in writing from the DoD Lead Environmental Component.

C1.7. LEAD ENVIRONMENTAL COMPONENT

C1.7.1. In accordance with DoDI 4715.05, the DoD Lead Environmental Component for these FGS is the Commander, U.S. Forces, Japan (COMUSFJ). Service Components shall consult the USFJ Command Engineer, on behalf of the DoD Lead Environmental Component, on matters regarding interpretation or exceptions to these FGS. Any questions or comments pertaining to these FGS shall be sent to:

Commander, U.S. Forces, Japan Unit 5068, Attn: USFJ/Command Engineer

APO, AP 96328-5068

DSN Voice (315) 225-4713

DSN FAX (315) 225-4709

Commercial +81 (042) 552-2510, Ext 54713

Chapter 2, Air Emissions 5

C2. CHAPTER 2

AIR EMISSIONS

C2.1. SCOPE

This Chapter contains criteria for air emissions sources. Criteria addressing open burning of solid waste are contained in Chapter 7, “Solid Waste.” Criteria addressing asbestos are contained in Chapter 15, “Asbestos.”

C2.2. DEFINITIONS

C2.2.1. Coal Refuse. Waste products from coal mining, cleaning and coal preparation operations (e.g., culm and gob) containing coal, matrix material, clay, and other organic and inorganic material.

C2.2.2. Cold Cleaning Machine. Any device or piece of equipment that contains and/or uses liquid solvent, into which parts are placed to remove soil and other contaminants from the surfaces of the parts or to dry the parts. Cleaning machines that contain and use heated, nonboiling solvent to clean the parts are classified as cold cleaning machines.

C2.2.3. Commercial and Industrial Solid Waste Incinerator (CISWI) Units. Any combustion device that combusts commercial and industrial waste in an enclosed device using controlled flame combustion without energy recovery that is a distinct operating unit of any commercial or industrial facility (including field-erected, modular, and custom incineration units operating with starved or excess air). CISWI units do NOT include Municipal Waste Combustor Units, Sewage Sludge Incinerators, Medical Waste Incinerators, and Hazardous Waste Combustion Units.

C2.2.4. Diesel Engine Generating Unit. Diesel Engine Generating Units that have a combustion rate ≥50 liters (13.2 gallons) per hour when calculated in terms of fuel oil consumption.

C2.2.5. Dioxins. Dioxins defined in this chapter are polychlorinated dibenzofurans (PCDFs), polychlorinated dibenzo-para-dioxins (PCDDs) and coplanar polychlorinated biphenyls (coplanar PCBs).

C2.2.6. Existing Incinerators. Any incinerator constructed on or before 1 December 1997.

C2.2.7. Fossil Fuel. Natural gas, petroleum, coal, and any form of solid, liquid or gaseous fuel derived from such material for the purpose of creating useful heat.

C2.2.8. Freeboard Ratio. The ratio of the solvent cleaning machine freeboard height to the smaller interior dimension (length, width, or diameter) of the solvent cleaning machine.

C2.2.9. Hydrofluorocarbon (HFC). A compound consisting of hydrogen, fluorine, and carbon often used as a replacement for Ozone-Depleting Substances (ODS).

6 Chapter 2, Air Emissions

C2.2.10. Gaseous (Compressed Gas) Engine Generating Unit. Gaseous Engine Generating Units that have the following specifications. The combustion rate of the engine is ≥35 liters/hour (9.24 gal/hour) when calculated in terms of fuel oil consumption.

C2.2.11. Gasoline Engine Generating Unit. Gasoline Engine Generating Units that have the following specifications. The combustion rate of the engine is ≥35 liters/hour (9.24 gal/hour) when calculated in terms of fuel oil consumption.

C2.2.12. Incinerator. Any furnace used in the process of burning solid or liquid waste for the purpose of reducing the volume of the waste by removing combustible matter, including equipment with heat recovery systems for either hot water or steam generation.

C2.2.13. Motor Vehicle. Any commercially-available vehicle that is not adapted to military use which is self-propelled and designed for transporting persons or property on a street or highway, including but not limited to passenger cars, light duty vehicles, and heavy duty vehicles.

C2.2.14. Municipal Waste Combustion (MWC) Units. Any equipment that combusts solid, liquid, or gasified municipal solid waste (MSW) including, but not limited to, field-erected MWC units (with or without heat recovery), modular MWC units (starved-air or excess-air), boilers (for example, steam generating units), furnaces (whether suspension-fired, grate-fired, mass-fired, air curtain incinerators, or fluidized bed-fired), and pyrolysis/combustion units.

Municipal waste combustion units do NOT include pyrolysis or MWC units located at a plastics or rubber recycling unit, cement kilns that combust MSW, internal combustion engines, gas turbines, or other combustion devices that combust landfill gases collected by landfill gas collection systems.

C2.2.15. Municipal Solid Waste (MSW). Any household, commercial/retail, or institutional waste. Household waste includes material discarded from residential dwellings, hotels, motels, and other similar permanent or temporary housing. Commercial/retail waste includes material discarded by stores, offices, restaurants, warehouses, nonmanufacturing activities at industrial facilities, and other similar establishments or facilities. Institutional waste includes materials discarded by schools, hospitals (nonmedical), nonmanufacturing activities at prisons and government facilities, and other similar establishments or facilities. Household, commercial/retail, and institutional waste does include yard waste and refuse-derived fuel.

Household, commercial/retail, and institutional waste does not include used oil; sewage sludge;

wood pallets; construction, renovation, and demolition wastes (which include railroad ties and telephone poles); clean wood; industrial process or manufacturing wastes; medical waste; or motor vehicles (including motor vehicle parts or vehicle fluff).

C2.2.16. New Incinerators. Any new Waste or Specified Waste Incinerator built on or after 2 December 1997.

C2.2.17. Ozone-Depleting Substances (ODS). Those substances listed in Table C2.T1.

C2.2.18. Pathological Waste. Waste material consisting of only human or animal remains, anatomical parts, and/or tissue, the bags/containers used to collect and transport the waste material, and animal bedding (if applicable).

Chapter 2, Air Emissions 7

C2.2.19. Perfluorocarbon (PFC). A compound consisting solely of carbon and fluorine often used as a replacement for ODS.

C2.2.20. Process Heater. A device that is primarily used to heat a material to initiate or promote a chemical reaction in which the material participates as a reactant or catalyst.

C2.2.21. Pyrolysis. The endothermic gasification of hospital waste and/or medical/infectious waste using external energy.

C2.2.22. Specified Waste Incinerator. A waste incinerator with a hearth area ≥0.5 m2 (5.38 ft2) or an incineration rate ≥50 kg/hr (110 lbs/hr).

C2.2.23. Soot and Dust. Particulate matter generated from combustion.

C2.2.24. Stack. Any point in a source covered by criteria contained in C2.3.1.1, C2.3.1.2, C2.3.2 (except paragraph C2.3.2.5), C2.3.3, C2.3.4, or C2.3.5 designed to emit pollutants.

C2.2.25. Steam/Hot Water Generating Unit. A device that combusts any fuel and produces steam or heats water or any other heat transfer medium. This definition does not include nuclear steam generators or process heaters.

C2.2.26. Substantially-Modified. Any modification to a facility/building, the cost of which exceeds $1 million, regardless of funding source.

C2.2.27. Vapor Cleaning Machine. A batch or in-line solvent cleaning machine that boils liquid solvent which generates solvent vapor that is used as a part of the cleaning or drying cycle.

C2.2.28. Volatile Organic Compound (VOC). Any organic compound (excluding substances which are not a source for the generation of suspended particulate matter or oxidants) that is emitted into the atmosphere and is in gaseous form at the time when scattered.

C2.2.29. Waste Incinerator. Any incinerator with a grate area ≥2 m2 (21.5 ft2) or an incineration rate ≥200 kg/hr (441 lbs/hr), and which burns solid or liquid waste to reduce volume by removing combustible matter, including equipment with heat recovery systems for either hot water or steam generation.

C2.2.30. Wood Residue. Bark, sawdust, slabs, chips, shavings, mill trim, and other wood products derived from wood processing and forest management operations.

C2.3. CRITERIA

C2.3.1. Steam/Hot Water Generating Units. Steam/Hot Water Generating Units with a heating area ≥10 m2 (107.6 ft2), or with a burner combustion rate of ≥50 liters (13.2 gallons) per hour when calculated in terms of fuel oil consumption, must comply with the standards provided in Tables C2.T2 (see also paragraph C2.3.10), C2.T3 and C2.T4.

8 Chapter 2, Air Emissions

C2.3.1.1. Air Emission Standards. The following criteria apply to units with a maximum design heat input capacity ≥10 million BTU/hr that commenced construction on or after 1 October 1994 or that were substantially modified since 1 October 1994.

C2.3.1.1.1. Steam/hot water generating units and associated emissions controls, if applicable, must be designed to meet the emission standards for specific sized units shown in Table C2.T5 at all times, except during periods of start up, shut down, soot blowing, malfunction, or when emergency conditions exist.

C2.3.1.1.2. For units combusting liquid or solid fossil fuels, fuel sulfur content (weight percent) and higher heating value will be measured and recorded for each new shipment of fuel. Use these data to calculate sulfur dioxide (SO2) emissions and document compliance with the SO2 limits using the equation in Table C2.T5 (see also paragraph C2.3.10).

Alternatively, install a properly calibrated and maintained continuous emissions monitoring system to measure the flue gas for SO2 and either oxygen (O2) or carbon dioxide (CO2).

C2.3.1.2. Air Emissions Monitoring. Steam/hot water generating units that commenced construction on or after 1 October 1994 or that were substantially modified since 1 October 1994 subject to opacity or nitrogen oxides (NOX) standards in C2.T5 must have a properly calibrated and maintained continuous emissions monitoring system (CEMS) to measure the flue gas as follows:

C2.3.1.2.1. For units with a maximum design heat input capacity >30 million BTU/hr: Opacity, except that CEMS is not required where gaseous or distillate fuels are the only fuels combusted.

C2.3.1.2.2. For fossil fuel fired units with a maximum design heat input capacity >100 million BTU/hr: NOX and either O2 or CO2.

C2.3.2. Incinerators. The following requirements do not apply to incinerators combusting hazardous waste or munitions. Refer to Chapter 6, “Hazardous Waste,” for information regarding hazardous waste disposal and incineration.

C2.3.2.1. Commercial and Industrial Solid Waste Incinerators (CISWI). All CISWI units must comply with the applicable emission standards in Table C2.T8 and operating limits in Table C2.T9 (see also paragraph C2.3.2.5).

C2.3.2.2. Municipal Waste Combustion (MWC) Units. Each MWC unit must comply with the applicable emission standards in Table C2.T8 and operating limits in Table C2.T9. The temperature of the combustion chamber must be maintained at ≥800°C (1,472°F), except during periods of start up, shut down, soot blowing, malfunction, or when emergency conditions exist.

C2.3.2.3. Sewage Sludge Incinerators. All sewage sludge incinerators that commenced construction on or after 1 October 1994 or that were substantially modified since 1 October 1994 and that burn more than 1 ton per day (tpd) of sewage sludge or more than 10% sewage sludge, must also be designed to meet a particulate emission limit of 0.65 g/kg dry sludge (1.30 lb/ton dry sludge) and an opacity limit of 20% at all times, except during periods of start up, shut down, malfunction, or when emergency conditions exist.

Chapter 2, Air Emissions 9

C2.3.2.4. Medical Waste Incinerators (MWI). The following standards apply to all units.

These requirements do not apply to any portable units (field deployable), pyrolysis units, or units that burn only pathological, low-level radioactive waste, or chemotherapeutic waste. Refer to Chapter 8, “Medical Waste Management,” for other requirements pertaining to medical waste management.

C2.3.2.4.1. All MWI must be designed and operated according to the following good combustion practices (GCP):

C2.3.2.4.1.1. Unit design: dual chamber.

C2.3.2.4.1.2. Minimum temperature in primary chamber: 760-871°C (1400- 1600°F).

C2.3.2.4.1.3. Minimum temperature in secondary chamber: 982-1204°C (1800- 2200°F).

C2.3.2.4.1.4. Minimum residence time in the secondary chamber: 2 seconds.

C2.3.2.4.1.5. Incinerator operators must be trained in accordance with applicable Service requirements.

C2.3.2.5. Additional Air Emission Monitoring for Waste and Specified Waste Incinerators. Waste and Specified Waste Incinerators must be monitored for hazardous air pollutants and dioxins in accordance with the standards in Tables C2.T2, C2.T3, and C2.T6.

C2.3.2.5.1. Hazardous Air Pollutant Monitoring. Installations that operate Waste Incinerators must monitor the hazardous air pollutants listed in Table C2.T2 twice a year.

C2.3.2.5.2. Dioxin Monitoring. Installations that operate Waste or Specified Waste Incinerators must monitor dioxin emissions listed in Table C2.T6 at least annually.

Additionally, ash from Waste and Specified Incinerators must be tested at least annually, and must have dioxin levels of 3.0 ng-TEQ/g or less. Ash not meeting this standard must be disposed of as a hazardous waste in accordance with Chapter 6, “Hazardous Waste.”

C2.3.3. Perchloroethylene (PCE) Dry Cleaning Machines. The following requirements apply to all dry cleaning machines. These requirements do not apply to coin-operated machines.

C2.3.3.1. Emissions from PCE dry cleaning machines installed before 1 October 1994 that use more than 2,000 gallons per year of PCE (installation wide) in dry cleaning operations, must be controlled with a refrigerated condenser, unless a carbon absorber was already installed.

The temperature of the refrigerated condenser must be maintained at ≤7.22°C (45°F). Dry cleaning machines and control devices must be operated according to manufacturer recommendations.

C2.3.3.2. All PCE dry cleaning systems installed on or after 1 October 1994 must be of the dry-to-dry design with emissions controlled by a refrigerated condenser. The temperature of

10 Chapter 2, Air Emissions the refrigerated condenser must be maintained at ≤7.22°C (45°F). Dry cleaning machines and control devices must be operated according to manufacturer recommendations.

C2.3.4. Chromium Electroplating and Chromium Anodizing Tanks. Electroplating and anodizing tanks must comply with one of the three methods below for controlling chromium emissions. Implement one of the following methods that is most appropriate to suit local conditions:

C2.3.4.1. Option 1: Limit chromium emissions in the ventilation exhaust to 0.015 milligrams per dry standard cubic meter (mg/dscm). Control devices/methods must be operated according to manufacturer recommendations.

C2.3.4.2. Option 2: Use chemical tank additives to prevent surface tension of the electroplating or anodizing bath from exceeding 45 dynes per centimeter (cm) as measured by a stalagmometer or 35 dynes/cm as measured by a tensiometer. Measure the surface tension prior to the first initiation of electric current on a given day and every 4 hours thereafter.

C2.3.4.3. Option 3: Limit chromium emissions to the maximum allowable mass emission rate (MAMER) calculated using the following equation: MAMER = ETSA x K x 0.015 mg/dscm, where: MAMER = the alternative emission rate for enclosed hard chromium electroplating tanks in mg/hr; ETSA = the hard chromium electroplating tank surface area in square feet (ft2); K = a conversion factor, 425 dscm/(ft2-hr). Option 3 is ONLY applicable to hard chrome electroplating tanks equipped with an enclosing hood and ventilated at half the rate or less than that of an open surface tank of the same surface area.

C2.3.5. Halogenated Solvent Cleaning Machines. These requirements apply to all solvent cleaning machines that use solvent which contains more than 5% by weight: methylene chloride (CAS No. 75-09-2), perchloroethylene (CAS No. 127-18-4), trichloroethylene (CAS No. 79-01- 6), 1,1,1-trichloroethane (CAS No. 71-55-6), carbon tetrachloride (CAS No. 56-23-5), chloroform (CAS No. 67-66-3), or any combination of these halogenated solvents.

C2.3.5.1. All cold cleaning machines (remote reservoir and immersion tanks) must be covered when not in use. Additionally, immersion type cold cleaning machines must have either a 1-inch water layer or a freeboard ratio of at least 0.75.

C2.3.5.2. All vapor cleaning machines (vapor degreasers) must incorporate design and work practices which minimize the direct release of halogenated solvent to the atmosphere.

C2.3.6. Units Containing ODS Listed in Table C2.T1, HFCs and PFC. The following criteria apply to direct atmospheric emissions of ODS, HFCs, and perfluorocarbons (PFC) from refrigeration equipment and ODS from fire suppression equipment.

C2.3.6.1. Refrigerant Recovery/Recycling. All repairs, including leak repairs or services to appliances, industrial process refrigeration units, air conditioning units, or motor vehicle air conditioners, must be performed using commercially available refrigerant recovery/recycling equipment operated by trained personnel. Refrigerant technicians shall be trained in proper recovery/recycling procedures, leak detection, safety, shipping, and disposal in accordance with recognized industry standards or Japanese equivalent.

Chapter 2, Air Emissions 11

C2.3.6.2. Refrigerant Venting Prohibition. Any class I or class II ODS, HFC, and PFC refrigerant shall not be intentionally released in the course of maintaining, servicing, repairing, or disposing of appliances, industrial process refrigeration units, air conditioning units, or motor vehicle air conditioners. De minimis releases associated with good faith attempts to recycle or recover ODS, HFC, and PFC refrigerants are not subject to this prohibition.

C2.3.6.3. Refrigerant Leak Monitoring and Repair. Monitor and repair refrigeration equipment for ODS leakage in accordance with the following criteria and repair, if found to be leaking.

C2.3.6.3.1. Commercial Refrigeration Equipment. Commercial refrigeration equipment normally containing >50 pounds of refrigerant must have leaks repaired if the appliance is leaking at a rate such that the loss of refrigerant will exceed 35% of the total charge during a 12-month period.

C2.3.6.3.2. Industrial Process Refrigeration Equipment. Industrial process refrigeration equipment normally containing >50 pounds of refrigerant must have leaks repaired if the appliance is leaking at a rate such that the loss of refrigerant will exceed 35% of the total charge during a 12-month period.

C2.3.6.3.3. Comfort Cooling Appliances. Comfort cooling appliances normally containing >50 pounds of refrigerant and not covered by paragraphs C2.3.6.3.1 or C2.3.6.3.2 of this chapter must have leaks repaired if the appliance is leaking at a rate such that the loss of refrigerant will exceed 15% of the total charge during a 12-month period.

C2.3.6.4. ODS Fire Suppression Agent (Halon) Venting Prohibition. Halons shall not be intentionally released into the environment while testing, maintaining, servicing, repairing, or disposing of Halon-containing equipment or using such equipment for technician training. This venting prohibition does NOT apply to the following Halon releases:

C2.3.6.4.1. De minimis releases associated with good faith attempts to recycle or recover Halons (i.e., release of residual Halon contained in fully discharged total flooding fire extinguishing systems).

C2.3.6.4.2. Emergency releases for the legitimate purpose of fire extinguishing, explosion inertion, or other emergency applications for which the equipment or systems were designed.

C2.3.6.4.3. Releases during the testing of fire extinguishing systems if each of the following is true: systems or equipment employing suitable alternative fire extinguishing agents are not available; release of extinguishing agent is essential to demonstrate equipment functionality; failure of system or equipment would pose great risk to human safety or the environment; and a simulant agent cannot be used.

C2.3.7. Motor Vehicles. This criteria applies to DoD-owned motor vehicles as defined in paragraph C2.2.13.

12 Chapter 2, Air Emissions

C2.3.7.1. All vehicles shall be inspected every 2 years to ensure that no tampering with factory-installed emission control equipment has occurred.

C2.3.7.2. If available on the local economy, use only unleaded gasoline in vehicles that are designed for this fuel.

C2.3.8. Stack Heights. Hg is the good engineering practice stack height necessary to minimize downwash of stack emissions due to aerodynamic influences from nearby structures.

C2.3.8.1. Stacks shall be designed and constructed to heights at least equal to the largest Hg calculated from either of the following two criteria:

C2.3.8.1.1. Hg = H + 1.5L, where H is the height of the nearby structure measured from the ground level elevation at the base of the stack, and L is the lesser of height or projected width of the nearby structure(s). A structure is determined to be nearby when the stack is located within 5L of the structure envelope but ≤0.8 km (0.5 mile). This calculation shall be performed for each structure nearby the stack being studied to determine the greatest Hg.

C2.3.8.1.2. Hg is the height demonstrated by a fluid model or a field study, which ensures that the emissions from a stack do not result in maximum ground-level concentrations of any air pollutant as a result of atmospheric downwash, wakes, or eddy effects created by the source itself, nearby structures, or nearby terrain features at least 40% in excess of the maximum ground-level concentrations of any air pollutant experienced in the absence of such atmospheric downwash, wakes, or eddy effects. For purposes of this paragraph, “nearby” means <0.8 km (0.5 mile), except that the portion of a terrain feature may be considered to be nearby which falls within a distance of up to 10 times the maximum height (Ht) of the feature, not to exceed 2 miles if such feature achieves a height (Ht) 0.8 km from the stack that is at least 40% of the good engineering practice stack height determined by the formulae provided in C2.3.8.1.1 of this part or 26 meters, whichever is greater, as measured from the ground-level elevation at the base of the stack. The height of the structure or terrain feature is measured from the ground-level elevation at the base of the stack.

C2.3.9. Diesel/Gaseous/Gasoline Engine Generating and Gas Turbine Units. These units must comply with the emission standards in Tables C2.T2, C2.T3 and C2.T4. The following are exempt from these standards:

C2.3.9.1. Portable or mobile equipment.

C2.3.9.2. Stationary back-up power equipment, such as emergency generators.

C2.3.10. Emission Limits for Sulfur Oxides. Maximum permissible emission limits for the amount of sulfur oxides emitted from an outlet of a facility, q, is calculated as follows:

where, 2310 eHKq

Chapter 2, Air Emissions 13 q is the hourly volume of SOX emitted (Nm3/hr). Nm3 represents m3/hour at a normal temperature of 0C and a pressure of 1 atmosphere.

K is a constant value assigned to each designated region. The most protective value (e.g., the smallest K-value) applicable to the region must be used (see Table C2.T7).

He is the effective stack height calculated as follows:

where, He is the effective stack height, in meters

Ho is the actual stack height, in meters.

Q is the flue gas flow rate at 15C (59F) in m3/sec

V is the flue gas speed in m/sec and

T is the flue gas temperature, in absolute temperature

C2.3.11. Volatile Organic Compound (VOC). Operators will incorporate procedures which minimize the direct release of VOCs into the atmosphere at painting facilities, printing facilities, cleaning facilities, storage tanks, drying facilities and/or resin dryer. Emissions from those facilities using organic solvents shall not exceed the threshold values indicated in Table C2.T10.

tmoe HHHH 65.0

V

VQ

Hm 58.2

795.0

)1 log30.2()288(1001.2 3

J JTQHt

1)

2961460(

T

V

VQ

J

14 Chapter 2, Air Emissions

Table C2.T1. Class I and II Ozone Depleting Substances

Class I CFC - 11 CFC - 114 CFC - 215 Halon - 1211 CFC - 12 CFC - 115 CFC - 216 Halon - 1301 CFC - 13 CFC - 211 CFC - 217 Halon - 2402 CFC - 111 CFC - 212 Carbon Tetrachloride CFC - 112 CFC - 213 Methyl Chloroform CFC - 113 CFC - 214 Methyl Bromide CHFBr2 C2H2F3Br C3HF6Br C3H3F4Br HBFC-2201 (CHF2Br) C2H3FBr2 C3H2FBr5 C3H4FBr3 CH2FBr C2H3F2Br C3H2F2Br4 C3H4F2Br2 C2HFBr4 C2H4FBr C3H2F3Br3 C3H4F3Br C2HF2Br3 C3HFBr6 C3H2F4Br2 C3H5FBr2 C2HF3Br2 C3HF2Br5 C3H2F5Br C3H5F2Br C2HF4Br C3HF3Br4 C3H3FBr4 C3H6FBr C2H2FBr3 C3HF4Br3 C3H3F2Br3 Chlorobromomethane C2H2F2Br2 C3HF5Br2 C3H3F3Br2

Class II HCFC – 21 HCFC – 133a HCFC – 225cb HCFC – 243 HCFC – 22 HCFC – 141b HCFC – 226 HCFC – 244 HCFC – 31 HCFC – 142b HCFC – 231 HCFC – 251

HCFC – 121 HCFC – 151 HCFC – 232 HCFC – 252

HCFC – 122 HCFC – 221 HCFC - 233 HCFC – 253

HCFC – 123 HCFC – 222 HCFC – 234 HCFC – 261

HCFC – 124 HCFC – 223 HCFC – 235 HCFC – 262

HCFC – 131 HCFC – 224 HCFC – 241 HCFC – 271

HCFC – 132b HCFC – 225ca HCFC – 242

Note: All isomers of the above chemicals are ODS, except isomers of (1,1,1-trichloroethane (also known as methyl chloroform)) such as 1,1,2-trichloroethane.

Chapter 2, Air Emissions 15

Table C2.T2. Emission Standards for Hazardous Air Pollutants

Substance Emission Source Emission Standards Methods

Sulfur Oxide

(SOX)

Combustion of fuel and minerals in boilers, stationary engines and waste incinerators

1. The standard is set according to the height of the exhaust outlet (He) and the value of K assigned to each area (see paragraph C2.3.10)

General emission standards:

K = 3.0 to 17.5

Special emission standards:

K = 1.17 to 2.34

2. Fuel use standard:

Sulfur in fuel is set for each area.

Sulfur content: <0.5 to 1.2 %

3. Total emissions:

Set for each area/factory based on the total emission reduction plan.

1. SOX: JIS K0103

Emission quality: JIS Z8808.

2. Sulfur content in fuel: JIS

K2301, JIS K2541 to K2541- 7 or JIS M8813

3. Fuel consumption: JIS Z8762-1 to Z8762-4, or equivalent.

Soot & Dust

Combustion of fuel and minerals in boilers, stationary engines, waste incinerators and the use of an electric furnace

Emission standards for each facility/scale (see Table C2.T3)

General emission standards:

0.04 - 0.3 g/Nm3

Special emission standards:

0.03 - 0.2 g/Nm3

Soot & Dust: JIS Z8808

O2: Absorption method using an Orsat gas analyzer (or equivalent)

Hydrogen Chloride (HCl)

Combustion or chemical treatment at waste

Emission standard for Waste Incinerators:

700 mg/Nm3

In Saitama Prefecture, emission standard for waste incinerators with a grate area ≥2 m2 or incineration capacity ≥200 kg/hr:

Incineration capacity ≥500 kg/hr, allowable limits are 200 mg/Nm3

Incineration capacity <500 kg/hr, allowable limits are 500 mg/Nm3

HCl for waste incinerators:

Measuring HCl concentration by the methods stipulated in JIS K0107, and the oxygen concentration in the emission gas by the same method of soot and dust.

Nitrogen Oxide

(NOX)

Combustion, synthesis or degradation in a boilers, stationary engines, and waste

1. Emission standards for each facility/scale (see Table C2.T3) 60 - 950 ppm

2. Total emissions Set for each area/factory based on total emission reduction plan

JIS K0104 for measuring NOX concentration in the emission gas, and JIS Z8808 for measuring soot and dust for the oxygen concentrations in the emission gas.

Notes:

Target Facilities:

Boiler: Heating surface area ≥10 m2 Stationary Engine: Fuel Combustion Rate: ≥50 L/hr (Gas Turbine and Diesel Engine) Fuel Combustion Rate: ≥35 L/hr (Gaseous and Gasoline Engine) Waste Incinerator: Grate area ≥2 m2, or burning capacity ≥200 kg/hr Monitoring Frequency: Twice a year

16 Chapter 2, Air Emissions

Table C2.T3. Emission Standards for Soot and Dust and NOX

Type of Facility Specification Types

Soot and Dust NOX Total

Emission (Nm3/hour)

General Area#1

(g/Nm3)

Special Area#2

Total Emission

Standard (ppm)

Boiler 1

Heating area 2 ≥10 m2, or

Burner combustion rate ≥50 L/hr 3

Gas boiler heating area ≥10 m2 burner combustion rate:

≥50 L/hr

≥40,000 0.05 0.03

≥500,000 60 ≥40,000 but <500,000

<40,000 0.10 0.05

≥10,000

<40.000

<10,000 150

Liquid boiler or gas and liquid boiler burner combustion rate:

≥50 L/hr

≥200,000 0.05 0.04 ≥500,000 130

<200,000

0.15 0.05

<40,000

0.25 0.15

<10,000 0.30 0.15 <10,000 180

Black liquid boiler or black liquid and gas or liquid fuel boiler

≥200,000 0.15 0.10

0.25 0.15

<40,000 0.30 0.15 <10,000 180

Liquid fuel boiler (heating area <10 m2)

-- 0.30 0.15 -- 260

Coal boiler (heating area ≥10 m2)

≥200,000 0.10 0.05 ≥700,000 200

<700,000 250 ≥40,000

0.20 0.10

<40,000 0.30 0.15 <40,000 300

Coal boiler (heating area <10 m2)

-- 0.30 0.15 -- 350

Solid fuel boiler (others whose heating area is ≥10 m2)

≥40,000 0.30 0.15

≥700,000 200

<700,000

<40,000 0.30 0.20 <40,000 300 Solid fuel boiler (others whose heating area is <10 m2)

-- 0.30 0.20 -- 350

Boilers (others)

≥40,000 0.30 0.15

<40,000 0.30 0.20

<10,000 180

Chapter 2, Air Emissions 17

Table C2.T3. Emission Standards for Soot and Dust and NOX (continued)

Type of Facility Specification Type

Soot and Dust NOX Size

(metric tons/hour)

General Area#1

Special Area#2

Standard (ppm)

Gas Turbine Engine Fuel Combustion Rate: ≥50 L/hr3

0.05 0.04

Diesel Engine 0.10 0.08 950

Gaseous Engine Fuel Combustion Rate: ≥35 L/hr

0.05 0.04 600

Gasoline Engine 0.05 0.04 600

Waste material incinerator

Grate area: 2 ≥2 m2

Incineration rate:

≥200 kg/hr continuous incinerator (by vortex combustion method)

≥4 0.04

All 450 ≥2 but <4 0.08

Peculiar 4 waste continuous material incinerator

≥4 0.04 ≥40,000 250

≥2 but <4 0.08 <40,000 700 continuous incinerator (others)

≥4 0.04 All 250

≥2 but <4 0.08 incinerator (others)

<2 0.15 ≥40,000 250

<40,000 --

#1. Soot and dust emission standard per Nm3 of emitting gas in general area (see Table C2.T7).

#2. Soot and dust emission standard per Nm3 of emitting gas in special area (see Table C2.T7). These standards apply for facilities built after 1 June 1982 in Tokyo Metropolitan area (special wards), Yokohama and Yokosuka.

1. Hot blast boilers are included. Boilers which use electricity or waste heat alone are excluded.

2. Horizontal projected area.

3. Calculation in terms of heavy oil.

4. A “peculiar” incinerator refers to an incinerator that burns waste generated from a process that produces or uses nitro-, amino-, or cyano-compounds or their derivatives, or from a process that treats wastewater using ammonia.

5. Monitoring Frequency: Twice a year.

(Nm3 = Normal cubic meters)

18 Chapter 2, Air Emissions

Table C2.T4 Emission Standard for NOx (applies to facilities located in Tokyo Prefecture)

Type of Facility

Type Scale Date Facility Installed Emission Standard (ppm)

Class 1 Area1 Class 2 Area1

Boiler

Gas Boiler

Fuel combustion capacity ≥100 L/hr

Prior to 15 Mar 1991 80 85 On or After 15 Mar 1991 45 45 capacity <100 L/hr

Prior to 15 Mar 1991 85 95 On or After 15 Mar 1991 45 55

Liquid Boiler capacity ≥100 L/hr

Prior to 15 Mar 1991 90 100 15 Mar 1991 to 31 Mar 2001 65 65 On or After 1 Apr 2001 50 65 capacity <100 L/hr

Prior to 15 Mar 1991 100 110 On or After 15 Mar 1991 65 75

Gas Turbine

Gas Turbine (gaseous fuel)

Rated output:

>50,000 kw

Prior to 1 Apr 2001 25 35 On or After 1 Apr 2001 10 10

2,000-50,000 kw

Prior to 1 Apr 1992 35 35 On or After 1 Apr 1992 25 35

< 2,000 kw

Prior to 1 Apr 1992 50 50 On or After 1 Apr 1992 35 50

Gas turbine (liquid fuel)

>50,000 kw

Prior to 1 Apr 2001 25 50 On or After 1 Apr 2001 10 10

2,000-50,000 kw

Prior to 1 Apr 1992 50 50 On or After 1 Apr 1992 25 50

< 2,000 kw

Prior to 1 Apr 1992 60 60 On or After 1 Apr 1992 35 60

Diesel Engine

Fuel combustion ≥ 25 L/hr, and rated output ≥ 2,000 kw

Prior to 1 Apr 1992 190 380 On or After 1 Apr 1992 110 270

Fuel combustion ≥ 25 L/hr, and rated output < 2,000 kw

Prior to 1 Apr 1992 190 610 On or After 1 Apr 1992 110 500

Fuel combustion < 25 L/hr Prior to 1 Apr 1992 500 610 On or After 1 Apr 1992 380 500

Gas

Fuel combustion ≥ 50 L/hr Prior to 1 Apr 1992 300 500 On or After 1 Apr 1992 200 500

Fuel combustion < 50 L/hr Prior to 1 Apr 1992 500 500

On or After 1 Apr 1992 300 500

Gasoline

Fuel combustion ≥ 50 L/hr Prior to 1 Apr 1992 300 500 On or After 1 Apr 1992 200 500

Fuel combustion < 50 L/hr Prior to 1 Apr 1992 500 500 On or After 1 Apr 1992 300 500

1. Class 1 Areas: Areas which is designated as Special District, Musashino City, Mitaka City, Chofu City, Komae

City, Nishitokyo City (limited to the area of former Hoya City).

Class 2 Areas: All areas other than those defined as Class 1 Area.

Chapter 2, Air Emissions 19

Table C2.T5. Emission Standards for Steam Generating Units 1

Maximum Design Heat Input Capacity 10 – 100 million BTU/hr Size >100 million BTU/hr Fuel Type PM Opacity 2 SO2

3 PM Opacity 2 SO2

3 NOX

Gaseous N/A N/A N/A N/A N/A N/A 0.20 Gaseous - Coal Derived N/A N/A N/A N/A N/A N/A 0.50 Liquid Fossil Fuel N/A 20% 0.50 5 0.10 20% 0.80 0.30 Solid Fossil Fuel 0.10 20% 1.20 0.10 20% 1.20 0.70 Other Solid Fuel 6 0.30 20% N/A 0.20 20% N/A N/A

N/A = Not applicable.

1. Standards apply to units constructed or substantially modified after 1 October 1994.