This document is a detailed specification sheet for Druck Pressure Transducers, outlining comprehensive technical requirements for the devices. The specification mandates a range of technical parameters including a supply voltage of 7-32 Vdc, a MIL-C 26482 Demountable electrical connector, 0-5V output voltage, and temperature compensation from -40 to 125 degrees Celsius. Additional critical specifications include improved accuracy of +/-0.2% full scale, frequency response to 3.5kHz, 4XFS over pressure range, 500Vdc 100Mohm insulation, and a 10ms power up time. The transducers must be constructed of stainless steel, feature a ¼ NPT female mechanical connection, include RoHS 2002/95/EC certification, and provide shunt calibration with a customer-accessible connection.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specification
Druck Pressure Transducers Should All have minimum of:
- Supply voltage 7-32 Vdc
- Electrical connector: MILC 26482 Demountable
- 0-5V output voltage
- Compensated Temperature: -40 to 125degC
- Improved accuracy +/-0.2%Full scale
- Frequency response to 3.5kHz
- 4XFS over pressure range
- 500Vdc: 100Mohm insulation
- 10ms power up time
- Room temperature linearity calibration
- ¼ NPT female mechanical connection
- Certification RoHS 2002/95/EC
- Stainless steel construction
- Shunt calibration with a customer accessible connection