About this file
This document is a Statement of Work (SOW) for the replacement of Carbon Seals used in the W7 of the Engine Research Building at the NASA Glenn Research Center. The SOW specifies that the Stein Seal Replacement kit SSCY14828900 is required to prevent the leakage of Dexron fluid into the test article/test facility. A quantity of 3 replacement kits is requested to replace worn seals and replenish damaged stock.
The related federal contract opportunity is a Special Notice for the procurement of the Stein Seals Replacement Seal Kits. NASA/NSSC intends to issue a sole source contract to Stein Seal Company under the authority of FAR 13.106-1(b)(1)(i), as Stein Seal Company is the sole provider of these seals. The NAICS code for this procurement is 336412. Interested organizations may submit their capabilities and qualifications by 3:00 p.m. Central Standard Time on 7/26/2024. The procurement will be conducted using FAR Part 12 and FAR Part 13 procedures for the acquisition of commercial items and services.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SATPC0035789 Tab 07 Capability.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work for Carbon Seal Replacement
The Stein Seal Replacement kit SSCY14828‐900 is a required Carbon Seal kit that is used in W7 of the Engine Research Building. This seal prevents the leakage of Dexron fluid into the test article/test facility. Significant Engineering has been spent developing this seal and incorporating it into the design of the Legacy Facility Hardware. Specifically, this carbon seal is installed in NASA PN 130601MRA212, sub assembly of Front Bearing Assembly 130601MRA200.
Previous seals have been worn due to normal use, or damaged during improper installation. A qty of 3x of the Replacement kit SSCY14828‐900 is requested to replace worn seals, and replenish stock of damaged seals.
Nicholas Bushik Electrical Test Engineer
HX5/Sierra (TFOME‐II)
NASA Glenn Research Center
21000 Brookpark Rd., MS 23‐1
Cleveland, OH 44135
Office: 216‐433‐3450 nicholas.k.bushik@nasa.gov