SATPC0032186 Tab 04 Specifications Sheet.pdf

PDF 127 KB Posted

Attached to
An optical telescope for Doppler Lidar Federal contract opportunity
Solicitation number
80NSSC23842717Q
Issued by
National Aeronautics and Space Administration Shared Services Center

About this file

This document outlines technical specifications for an optical telescope and related federal contract opportunity. The specifications call for an off-axis telescope design with a diffraction-limited optical design, mirror flatness of 1/10 wave or better at 632 nm, high reflectivity at 1977 nm, 25x magnification, mirror coatings to withstand 1600 W/square cm average power and 0.3J/square cm single pulse energy. Additional requirements include a 4-mm input aperture, adjustable focus via secondary mirror translation, mounting holes for an optical table, use in an air-conditioned lab, a dust cover, and a 10-day lead time. The related federal contract opportunity from NASA's Shared Services Center seeks this optical telescope for a Doppler lidar system under solicitation number 80NSSC23842717Q.

View the file

Other files for this federal contract opportunity

Other files attached to An optical telescope for Doppler Lidar, newest first.
File Type Posted
SATPC0032186 Tab 10 1 RFQ Open Market.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Optical Telescope Requirements

There is a need for a telescope for our Doppler lidar system. The minimum requirements for the telescope are as follows:

(1) Off-axis configuration such as Dall-Kirkham design

(2) Diffraction-limited optical design

(3) Surface figure flatness of both mirrors of 1/10 peak-to-valley wave or better at 632 nm.

(4) High reflectivity of mirrors at 1977 nm

(5) Magnification of 25X

(6) Mirror coatings to tolerate without damage a 1600 W/square centimeter for average power and 0.3J/square centimeter for single pulse energy (pulse width 500ns)

(7) Input aperture to accommodate 4-mm 1/e2 diameter beam

(8) Adjustable focus by manual translation of secondary mirror (focus is necessary to create a collimated output from a diverging laser beam input)

(9) Mounting holes on bottom to accommodate mounting to an optical table

(10) To be used in air-conditioned laboratory environment.

(11) Cover for protection from dust

(12) Lead Time 10 Days