SALIENT CHARACTERISTICS
For
PECI Floatation Support System TFSS-5326
1.0. SCOPE OF EQUIPMENT:
All proposed products shall meet or exceed the following specifications outlined in this Salient Characteristics. All items shall be delivered to the 48th Rescue Squadron (48th RSQ) – FOB
DESTINATION
1.1. PRODUCT PERFORMANCE SPECIFICATION:
Please note that this is brand name specific, only NEW equipment and the following description below will be considered technically acceptable.
PECI Floatation Support System must meet the following specifications:
SPECIFICATIONS
PECI Floatation Support System TFSS-5326
PECI Floatation Support System
TFSS-5326:
• Must have the following: TFSS-5326 o 1.1.A Minimum Buoyancy per Unit: 40 lbs. lift in seawater, at the surface, with air and water temperature of 70° F (approximately 22 lbs.
lift at 33 ft. sea water) o Minimum Buoyancy per System: 80 lbs. lift in seawater, at the surface, with air and water temperature of 70° F (approximately 45 lbs. lift at 33 ft. sea water) o Oral Inflation: Left and right oral inflation tubes o Corrosion Resistance: All parts are corrosion resistant in fresh and salt water o Rot Resistance: All fabric, webbing, and binding are rot resistant o System Identification: Each pair is identified by the manufacture date and a space is provided for an organization's unique serial number. Left side unit identified with the suffix "L"; right side unit identified with the suffix "R". Each unit is marked individually.
o Unique Grommet, Loop, and Pin (GLP) Closure System o Manual Inflation: Left and right manually operated CO2 systems o (2) 38 Gram CO2 Cartridges o Pouch Color: Coyote o Bladder: Covert – Black o For covert operation purposes, the PECI must be a tan colored pouch with black bladder.
| SALIENT CHARACTERISTICS |
| For |
| PECI Floatation Support System TFSS-5326 |
| 1.1. PRODUCT PERFORMANCE SPECIFICATION: |