This document appears to be a set of Salient Characteristics for a Radial Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES) instrument. The salient characteristics describe the software, peristaltic pump, nebulizer, spray chamber, torch, injector, RF generator, optical system, cooling, electrical requirements, and other features of the ICP-OES instrument.

The related federal contract opportunity is a solicitation from the Defense Logistics Agency Land and Maritime for an ICP-OES instrument. The solicitation number is SPMYM224Q2273. No additional details about the solicitation requirements, response dates, award information, or other terms are provided in the given materials.

View the file

Other files for this federal contract opportunity

Other files attached to ICP-OES, newest first.
File Type Posted
SOLE SOURCE.pdf PDF
SPMYM2-24-Q-2273.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics for Radial Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES)

a. Radial ICP-OES description:

a. Software: Qtegra ISDS Software

b. Peristaltic pump: 4-channel peristaltic pump for stable sample introduction with free tunable pump speed to facilitate any analysis needs

c. Nebulizer: Glass concentric

d. Spray chamber: Single pass glass cyclonic

e. Torch: Ceramic D-torch with vertical orientation, ease-of-use torch design for simplified maintenance and installation, as well as reliable positioning of the torch for reproducible results

f. Injector: Quartz 1.5 mm diameter bore

g. Solid state 27.12 MHz RF generator as power source to the plasma with free tunable RF power for customized sample analysis

h. Load coil: Water cooled with PTFE coating

i. Additional gas: Additional MFC adjustable via software between 0.0-0.25 L/min

j. Plasma viewing: Radial adjustable 6 to 18 mm

k. Optical system: Echelle polychromator for ultra-stable analyses

l. Optical path purge: Argon or nitrogen purged

m. CID camera cooled down to -45 degrees Celsius for low background noise

n. Fully interlocked torchbox with safety viewing window and sliding door to contain plasma with a unique exchangeable inner torch box to prevent corrosion

o. Free tunable auxiliary, nebulizer and cool gas flows for customization of sample analysis

p. Addition of Ar, air or O2 through an extra MFC controlled gas box for demanding applications

q. Full interlock control of gas and water flow, exhaust, polychromator and camera temperature

r. Interlocked drain sensor allows for safe, unattended analysis, prevents spillage and saves sample in case of interruptions in the sample introduction

s. LED status bar to display instrument and analysis status

t. Plasma TV for remote observation of the plasma

u. Tunable radial viewing height for optimum performance

v. Gas saving standby mode

w. Boost purge capabilities for ultra-fast warm-up

x. Enhanced UV (eUV) capability for improved detection limits for elements like e.g. Al, As, Cd, Hg, P, Pb and S

y. Advanced plug-in control for autosamplers, auto-dilution and other accessories

z. Cooling water supplied from an external recirculating chiller

aa. Power requirements: 200-240 V, 50-60 Hz, single phase, 20 A (North

America)

bb. Designed and manufactured by an ISO9001 registered company.

cc. Spectral band pass <7 pm

dd. Wavelength coverage from 167 to 847 nm

ee. Detector type: Charge injection device CID821 Array size 2048 x 2048 pixel array

ff. Detector cooling temperature: -45 ˚C with tolerance of 0.1 ˚C

gg. Dimensions: 615 mm W x 690 mm D x 933mm H

2. Autosampler description:

a. Four-rack sample system for automated liquid sample introduction into a variety of analysis instrumentation

b. 84 to 384 solution capacity dependent on rack configuration.

c. Suitable for 100 – 240V and 50/60Hz operation.

d. Contains:

Autosampler, baseplate, rinse station and tubing Power supply and different chords One USB cable for communication Two carbon-fiber probes: 0.5 mm i.d. (blue band) and 0.8 mm i.d. (red band) Ten 50 mL polypropylene tubes with caps for standards One 60 position BelArt tube rack Sixty 14 mL polypropylene tube

3. Data station for radial ICP-OES description:

a. Dell OptiPlex 3080MT for ICP-OES and AAS

b. 24“ flat screen monitor

c. Intel® Core i3-10100 (3.60 GHz, 6 MB) Processor

d. Windows 10 IoT Enterprise (64 bit)

e. 16 GB (8 GB*2) (DDR4 2400 MHz) Memory

f. 1 TB 7200 rpm SATA Hard Disk Drive

g. Intel (HD 4600) Integrated Graphics Card

h. 8x DVD+/-RW Optical Drive

i. 2 (1 integrated network card, 1 PCI-Network card) Network Adapters

j. DELL USB Optical Mouse and USB Keyboard English version

k. 3 Year Hardware Service Warranty with Onsite Service After Remote Diagnosis

l. Electrical: 100 V/50 Hz

4. Qtegra ISDS Software

a. Get Ready for a fully automated, data driven startup process

b. Simple, intuitive, and guided user input sequence delivering faster setup time

c. Simplified creation of LabBooks with Templates

d. Facilitated sample data input from digital Barcode/QR Code readers or LIMS Systems.

e. Data processing capabilities for trace elemental quantification

f. Integrated Inter-element Correction (IEC) workflow based on intensity or concentration

g. Clear data visualization and data transparency

h. Comprehensive data export and reporting options

i. Full suite of 21CFR Part 11 compliance tools

5. Chiller for Radial ICP-OES description:

a. Air cooled chiller with a cooling capacity of 900 W for a temperature range of 5° to 40° C.

b. Electrical: 115 V/60 Hz

c. Water recirculator

6. Radial Organics Kit

a. Radial Quartz Torch

b. Quartz Center Tube, 1 mm ID

c. Torch Holder and Center Tube Holder

d. Baffled Cyclonic Spray Chamber

e. V-Groove Nebulizer

f. Spray Chamber Adapter

g. Ball Joint Clip

h. Tubing Set and Sampling Probe

i. Sample and drain pump tubing needs to be ordered in addition.

7. Include extended warranty and maintenance support plan.