The document provided appears to be the "Salient Characteristics" for the Aqua-Dyne Blastmax 50 (or equal) high pressure water jetting system, which is the subject of a federal contract opportunity solicited by the Defense Logistics Agency (DLA) Maritime Puget Sound Naval Shipyard/TRF Bangor.

The key details are:

  • The Aqua-Dyne Blastmax 50 system (or equal) must have a high pressure water jetting capability of 10,000 PSI at 7 GPM, with a manual pressure control valve, rupture disc/relief valve, and be approximately 48" tall x 45" wide x 34" deep to allow for portability and fit into naval vessel engineering spaces.
  • The system must be Nationally Recognized Testing Laboratory (NRTL) certified to comply with applicable OSHA regulations.
  • The system must have integral lifting points and forklift slots/tubes for proper handling and lifting.
  • The federal contract opportunity is for a firm-fixed price contract for a "Blast Machine" under NAICS code 334419, with a 750 employee size standard. Quotes must be submitted via email or fax by the deadline.

View the file

Other files for this federal contract opportunity

Other files attached to BLAST MACHINE, newest first.
File Type Posted
EXHIBIT B CDRL.pdf PDF
SPMYM2-24-Q-1620.pdf PDF
EXHIBIT A CDRL.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Aqua-Dyne Blastmax 50 (or equal) Salient Characteris�cs

1. High Pressure Water Je�ng System (for cleaning Heat Exchanger Tubes)

* Rated for 10K PSI

* Rated for 7 GPM

* Manual Pressure Control Valve

* Rupture Disc for 11K PSI (Relief Valve will suffice if Rupture Disc not feasible)

* Dimensions of the system to be approximately: 48” Tall x 45” Wide x 34” Deep to allow for being portable and allowing system to fit down into the engineering.

spaces of a Naval Vessel.

* Equipped for ½” NPT outlet for Aeroquip quick connects for Hoses along with

Aeroquip quick connects for pressure gauge and relief valve.

* Standard Motor Control Cabinet (MCC) to be installed in lieu of the Variable

Frequency Drive (VFD) and a Fused Knife Disconnect installed on the unit.

* 10 Micron Filter installed on the water side.

* 50 HP Motor, 480V, 3 Phase, 60Hz, 59.2 Am

2. NRTL Cer�fica�on

* The equipment and its component parts shall be in compliance with applicable Code of Federal Regula�ons (CFR) Title 29, Part 1910. By defini�on, any equipment will be deemed acceptable and approved by TRF, Bangor, if it meets specific Occupa�onal Safety and Health Administra�on (OSHA) condi�ons outlined in CFR Title 29, Part 1910; Subparts "O" and "S". Specifically, equipment will be "Accepted" by TRF, Bangor, if it has been inspected and found by a Na�onally Recognized Tes�ng Laboratory (NRTL) to conform to specified plans or procedures of applicable codes. The equipment (as a whole system) shall be Na�onally Recognized Tes�ng Laboratory (NRTL) inspected and cer�fied (by an OSHA authorized third party). Two (2) “hard” copies of the NRTL cer�fica�on report shall be provided. If the equipment type/model has already been NRTL inspected and cer�fied, a cer�fica�on report (two (2) ”hard” copies) or documenta�on mounted on the equipment, (which acknowledges it is NRTL cer�fied), shall be provided.

3. Li�ing and Handling Cer�fica�on

* Li�ing and Handling - The specified equipment shall be equipped with four “maximum load” (including the total weight of the unit, including water, etc.) crane li�ing capable integral (not bolted on) li�ing point items such as lugs, thru-holes, pad-eyes, trunnions and ISO container corner fi�ngs (designed, located, installed and cer�fied per Process Instruc�on (PI) for “Padeyes: Temporary and Permanent;

Installa�on, Use and Removal of” (PI No. 611-400-026B), for Trident Refit Facility, Bangor (TRF, Bangor) ( A copy of this document can be provided upon request), mounted on the top of the unit, correctly spaced for even and level li�ing by a single crane hook (without use of spreader bar). The base of the equipment shall also have con�nuous full-length forkli� slots/tubes (in one direc�on) for handling the unit with a forkli� truck. The forkli� slots/tubes shall be sufficient size (to allow a small to medium forkli� to transport the equipment), and have sufficient separa�on (between the forkli� slots/tubes).

Each unit shall be tested. The Li�ing and Handling Cer�fica�on documenta�on shall be provided (for each unit) prior to delivery of the equipment.