This document outlines technical specifications for 4/0 heavy duty 600 volt welding cable required under Defense Logistics Agency Land and Maritime solicitation SPMYM223Q2152. The welding cable must meet specific standards including certification by a nationally approved testing laboratory, #34 AWG bunch stranded rope lay copper construction to reduce wire fatigue and increase flexibility and impact resistance, 100% fabric serve between wire and insulation jacket. The jacket must be flame and heat resistant "Super-Trex TSE" material or equivalent, and resistant to solvents and chemicals. Additional requirements include ink branding, soldered cam-loc connectors, minimum bend radius, integrity at -20 degrees, and resistance to chemicals including salt water, acids, jet fuel and other substances. The cable must measure 35 feet in length.

View the file

Other files for this federal contract opportunity

Other files attached to WELD LEAD, newest first.
File Type Posted
SPMYM2-23-Q-2152.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ORDERING SPECIFICATIONS FOR 4/0 HEAVY DUTY 600 VOLT

WELDING CABLE

DOCUMENT # 3073-3344

Must meet the following specifications:

• MUST BE APPROVED/CERTIFIED BY A NATIONALY APPROVED TESTING LABORATORY

• MUST BE # 34 AWG BUNCH STRANDED ROPE LAY COPPER TO REDUCE WIRE FATIGUE,

IMPROVE FLEXABILITY AND INCREASE IMPACT RESISTANCE

• MUST HAVE 100% FABRIC SERVE BETWEEN WIRE AND INSUALTION JACKET

• JACKET MUST BE ON "SUPER-TREX TSE" MATERIAL OR EQUAL AND MUST BE FLAME/HEAT

RESISTANT AND RESISTANT TO SOLVENTS AND CHEMICALS

• COPPER CABLE SHALL NOT TWIST INDEPENDENT OF JACKET CAUSING "BUNCHING" ON CABLE

JACKET BOUNDARY

• AVERAGE JACKE THICKNESS MUST BE 0.158"

• NOMINAL CABLE O.D. 0.900"

• JACKET AND CABLE CONNECTOR COVER MUST BE RED IN COLOR

• MUST BE PRIVATE PERMANENT INK BRANDED "PSNS PROPERTY SHOP 26" INTERMITTENTLY

DOWN LENGTH OF CABLE ALONG WITH DATE OF PRINTING

• CAM-LOC CABLE CONNECTORS MUST BE SOLDERED TO CABLE. MALE/FEMALE CAMLOC CABLE

CONNECTORS SHALL HAVE TAPER NOSE COVERS MOLDED TO WELD CABLE

• CABLE SHALL BE SUBJECTED TO MECHANICAL, CHEMICAL, ENVIRONMENTAL AND

OPERATIONAL TESTING COMMON TO INDUSTRIAL SHIP BUILDING/REPAIR ENVIRONMENTS.

MUST HAVE MINIMUM BEND RADIUS OF 7.2 INCHES

• CABLE JACKET WILL MAINTAIN INTEGRITY WHEN FLEXED AT -20 DEGREE TEMPERATURES

MUST BE 4/0 AWG/ 600 VOLT WELDING CABLE

• CABLE SHOULD RESIST CHEMICALS THAT INCLUDE BUT NOT LIMITED TO, SALT WATER, ACIDS, JET FUEL, PAINT, TURPENTINE, KEROSENE, HYDROCLORIC CHEMICALS AND GASOLINE

Must be 35 FT. long