This document outlines technical specifications for 4/0 heavy duty 600 volt welding cable required under Defense Logistics Agency Land and Maritime solicitation SPMYM223Q2152. The welding cable must meet specific standards including certification by a nationally approved testing laboratory, #34 AWG bunch stranded rope lay copper construction to reduce wire fatigue and increase flexibility and impact resistance, 100% fabric serve between wire and insulation jacket. The jacket must be flame and heat resistant "Super-Trex TSE" material or equivalent, and resistant to solvents and chemicals. Additional requirements include ink branding, soldered cam-loc connectors, minimum bend radius, integrity at -20 degrees, and resistance to chemicals including salt water, acids, jet fuel and other substances. The cable must measure 35 feet in length.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SPMYM2-23-Q-2152.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ORDERING SPECIFICATIONS FOR 4/0 HEAVY DUTY 600 VOLT
WELDING CABLE
DOCUMENT # 3073-3344
Must meet the following specifications:
• MUST BE APPROVED/CERTIFIED BY A NATIONALY APPROVED TESTING LABORATORY
• MUST BE # 34 AWG BUNCH STRANDED ROPE LAY COPPER TO REDUCE WIRE FATIGUE,
IMPROVE FLEXABILITY AND INCREASE IMPACT RESISTANCE
• MUST HAVE 100% FABRIC SERVE BETWEEN WIRE AND INSUALTION JACKET
• JACKET MUST BE ON "SUPER-TREX TSE" MATERIAL OR EQUAL AND MUST BE FLAME/HEAT
RESISTANT AND RESISTANT TO SOLVENTS AND CHEMICALS
• COPPER CABLE SHALL NOT TWIST INDEPENDENT OF JACKET CAUSING "BUNCHING" ON CABLE
JACKET BOUNDARY
• AVERAGE JACKE THICKNESS MUST BE 0.158"
• NOMINAL CABLE O.D. 0.900"
• JACKET AND CABLE CONNECTOR COVER MUST BE RED IN COLOR
• MUST BE PRIVATE PERMANENT INK BRANDED "PSNS PROPERTY SHOP 26" INTERMITTENTLY
DOWN LENGTH OF CABLE ALONG WITH DATE OF PRINTING
• CAM-LOC CABLE CONNECTORS MUST BE SOLDERED TO CABLE. MALE/FEMALE CAMLOC CABLE
CONNECTORS SHALL HAVE TAPER NOSE COVERS MOLDED TO WELD CABLE
• CABLE SHALL BE SUBJECTED TO MECHANICAL, CHEMICAL, ENVIRONMENTAL AND
OPERATIONAL TESTING COMMON TO INDUSTRIAL SHIP BUILDING/REPAIR ENVIRONMENTS.
MUST HAVE MINIMUM BEND RADIUS OF 7.2 INCHES
• CABLE JACKET WILL MAINTAIN INTEGRITY WHEN FLEXED AT -20 DEGREE TEMPERATURES
MUST BE 4/0 AWG/ 600 VOLT WELDING CABLE
• CABLE SHOULD RESIST CHEMICALS THAT INCLUDE BUT NOT LIMITED TO, SALT WATER, ACIDS, JET FUEL, PAINT, TURPENTINE, KEROSENE, HYDROCLORIC CHEMICALS AND GASOLINE
Must be 35 FT. long