This document provides salient characteristics for downdraft benches for a federal contract opportunity with the Defense Logistics Agency Land and Maritime. The downdraft benches must be 78.0" long x 52" wide x 63.0" tall, weigh no more than 1300 lbs, and have a dust capacity of 2.8 cubic feet. Additional requirements include a downdraft velocity of 200 feet per minute, 460v/69Hz/3PH electrical requirements, a 5.0 TEFC 208-230/460/575 60Hz 3-phase motor, 480-1016 square feet of filter area, 3000 CFM airflow, a maximum load capacity of 75 lbs/square foot, and a maximum sound level of 72dB. The benches must meet MERV 14 HEPA filtration standards with Fibra-Web FR filters and a cartridge filtration method with automatic pulse cleaning. Additional features include hinged side panels, LED lighting, dust drawers, pre-wired controls, scratch resistant work surfaces, a magnehelic gauge, and a transition to mate with a 2 high x 1 wide Ultra-Lok assembly. The related federal contract opportunity is solicitation number SPMYM223Q1790 for downdraft benches through the Defense Logistics Agency Land and Maritime.

View the file

Other files for this federal contract opportunity

Other files attached to DOWNDRAFT BENCH, newest first.
File Type Posted
23Q1790 DOWNDRAFT BENCH.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SALIENT CHARACTERISTICS FOR DOWNDRAFT BENCHES

FOR JML 3107-3926

SIZE

o 78.0” long x 52” wide x 63.0” tall

WEIGHT

o 1300 lbs maximum

DUST CAPACITY

o 2.8 Cu/Ft

DOWNDRAFT VELOCITY

200 Feet per minute

ELECTRICAL REQUIREMENTS

o 460v/69Hz/3PH

MOTOR HORSEPOWER/REQUIREMENTS

o 5.0 TEFC 208-230/460/575 60Hz 3-PH

FILTER AREA

o 480-1016 Sq/Ft

AIRFLOW

o 3000 CFM

MAXIMUM LOAD FOR PARTS

o 75 Lbs/SqFt

MAXIMUM SOUND LEVEL

o 72 dB (A) Per ANSI S12.34,1988

FILTRATION RATING

o MERV 14 HEPA per ASHRAE 52.3-2007 with Fibra-Web FR filers

FILTRATION METHOD

o Cartridge with automatic pulse cleaning action

CABINET

o Hinged side wing panels that open for longer work pieces o LED lighting o Large capacity dust drawers o Pre-wired controls o Scratch resistant work surfaces o Magnehelic gauge o Transition to mate 2 High x 1 Wide Ultra-Lok assembly

File details come from the government source that posted it. Updated .