This document contains the Salient Characteristics for 06G Shop Equipment, which describes the requirements for a 20' x 8'6" x 8'0" steel dry freight ISO container. The key modifications and features include front-end intake louvers, rear-end intake louvers, curbside and roadside wall cutouts and roll-up doors, interior insulation and linings, HVAC systems, electrical and lighting systems, and painting/marking specifications. The related federal contract opportunity is for a Solicitation for a CONTAINER, SHIPPING requirement issued by the Defense Logistics Agency Land and Maritime. The Solicitation Number is SPMYM224Q2304.

View the file

Other files for this federal contract opportunity

Other files attached to CONTAINER, SHIPPING, newest first.
File Type Posted
SPMYM2-24-Q-2304.pdf PDF
EXHIBIT A CDRL.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics for

06G Shop Equipment 5/3/2023

NEW 20' x 8'6" x 8'0" STEEL DRY FREIGHT ISO CONTAINER

1. SCOPE - These salient characteristics reflects those characteristics that are essential to the minimum needs of the government for the following shop equipment, to include the following items:

Front End Modifications:

1.1. Cutout, Frame & reinforce (1) Clear Openings for intake louvers.

1.2. Supply & Install (1) Approx 40-1/2” Wide x 33” High intake louver

1.3. Cutout, frame & reinforce (2) clear openings for intake louvers

1.4. Supply & install (2) 12” square stationary intake louvers

Rear End Modifications (standard double cargo doors):

2.1. Cutout, frame & reinforce (2) clear openings for intake louvers, (1) in each cargo door. Supply & install (2) 12” square stationary intake louvers.

Curbside wall modifications or cut outs:

3.1. Cutout, frame & reinforce (1) 120” wide x 80” high clear opening for rollup door

3.2. Supply & install (1) 120” wide steel roll door, Janus type.

3.3. Cutout, frame & reinforce (1) 72” wide x 80” high clear opening for rollup door.

3.4. Supply & install (1) 72” wide steel rollup door, Janus type.

Roadside wall modifications or cut outs:

4.1. Cutout, frame & reinforce (2) clear openings for exhaust fans.

4.2. Cutout, frame & reinforce (1) 18” square opening for hoses and electrical cables. Includes removable gasket cover plate.

4.3. Power entry #1 – Supply & install threaded coupling with piping to main power distribution panel ready for customer’s hard wire connection.

Interior walls & ceiling, insulation & linings:

5.1. Supply & install SBI standard insulation package in 20’ container, which consists of 1-1/2” foam insulation, 3/8” plywood with white textured plastic lining. Thermal value approx. R10.

Heating, ventilation & air conditioning systems (hvac)

6.1. Supply & install (2) 24” direct drive Sutter mount exhaust fan. Includes single speed thermostat.

Electrical & lighting systems:

7.1. Load center: Supply & install (1) each 100 amps, 240 volts, 60Hz, 10

7.2. Circuit 1 – lighting: Supply & install (2) 4’ long, 6,250 Lumens, 45 Watt 120-277 VAC, LED light fixture. IP65 Rated. PN: VTS4/PS60/840/UD. Budget provides (1) light switch & breaker. Optional light setting

– 60 watts/8,000 lumens.

7.3. Circuit 2 – receptacles: Supply & install (2) each duplex receptacles, Nema 5-20R, 20 Amp breaker

7.4. Circuit 3 – receptacles: Supply & install (2) each duplex receptacles, Nema 5-20R, 20 Amp breaker

7.5. Circuit 4 – exhaust fan: Supply & install (1) breaker.

7.6. Supply & install (1) Each grounding stud to power entry location.

Salient Characteristics for

06G Shop Equipment 5/3/2023

Painting Specifications & Markings – Interior & Exterior:

8.1. 20’ container blast welds SSPC-SP10 and brush blast needed areas

New Exterior Industrial Paint On Walls & Roof:

9.1. 20’ container paint preparation & cleaning

9.2. 20’ container primer and top coat:

9.3. 66% zinc primer

9.4. Polyzen top coat

New interior industrial paint on walls & ceiling:

10.1. 20’ container paint preparation & cleaning

10.2. 20’ container primer and top coat:

10.3. 66% Zinc Primer

10.4. Polyzen top coat

Markings:

11.1. Original unit numbers

11.2. Supply & install manufactured by ID plate. Note: Not for overseas transport

Quality Inspection, Testing, Data, Drawings and Customer Design & Review Meetings:

12.1. Quality check all features

12.2. General arrangement drawings

12.3. Project management