SALIENT CHARACTERISTIC

FOR CLINS 0001-0007

JMLS: 2117-3752 thru 2117-3758

CLIN 0001: 2117-3752

DESCRIPTION:

Repair and expendable parts replacement Salient Characteristics

These parts will be used to repair existing PSNS Government owned Proprietary Heat Exchanger Cleaning equipment. They will be used to effect emergent and pre-planned periodic repairs or, in the case of expendable items, replenish previously used on hand stock.

High Pressure Swivel Joint

This part will be used to repair existing PSNS Government owned Proprietary Heat Exchanger Cleaning equipment. They will be used to effect emergent and pre-planned periodic repairs on the self-powered SHR27 feed drum.

Must be compatible with, or adaptable to existing, Navy owned high pressure systems.

Outlet must be compatible with existing Navy equipment.

Inlet must be adaptable to fit existing, on hand Navy owned high pressure fittings.

Must be rated to 20,000 PSI Must be rated for 10 GPM Must be able to be used with water systems Must be 6” in diameter Must be about 6.750” long without additional adapters.

CLIN 0002: 2117-3753

Washer

This part will be used to restock expendable items relating to the STI-HD-3A Indexer, a Government owned Proprietary Heat Exchanger Cleaning tool, it’s previous or any more current designs. They will be used to replenish and make complete existing tool kits.

Must be compatible with Navy owned cleaning equipment Must be compatible in thickness and size for mounting and operating existing, Navy owned equipment.

Must be rust and corrosion resistant.

CLIN 0003:

DESCRIPTION: 2117-3754

Washer

This part will be used to restock expendable items relating to the STI-HD-UM X/Y Indexer, a Government owned and proprietary Heat Exchanger Cleaning tool, it’s previous or any more current designs. They will be used to replenish and make complete existing tool kits.

Must be compatible with Navy owned cleaning equipment Must be compatible in thickness and size for mounting and operating existing, Navy owned equipment.

Must be rust and corrosion resistant.

CLIN 0004: 2117-3755

4/2 Anti-withdrawl Device

This part will be used to restock expendable items relating to the STI-HD-3A and STI-HD-UM X/Y Indexer tool kits. They will be used to replenish and make complete existing kits.

Must be compatible with current existing Navy owned and designed umbilical systems and anti-withdrawl lance retention devices.

Must be rust and corrosion resistant.

Must fit inside existing 1/2” NPT 4/2 adapter.

CLIN 0005: 2117-3756

Feeder Communication wire

This part will be used to make complete existing kits and restock on hand material for the SHR27, a Government owned and proprietary Heat Exchanger Cleaning tool. It will be used for the emergent and planned repair of the SHR-27.

Must be compatible with the SHR27 Smart Feed/Plug detection assembly and Junction box.

Must be 8-pin.

Must be about 22”.

Must have 90 degree connections on each end.

CLIN 0006: 2117-3757

DESCRIPTION:

Swivel to lance adapter

This part will be used to make complete existing kits and restock on hand material for the High Pressure Swivel Joint, a part of a Government owned and proprietary Heat Exchanger Cleaning tool. It will be used for the emergent and planned repair of the High Pressure Swivel Joint, which is a sub-component of the SHR27.

Must be compatible with the outlet end of the high pressure swivel joint.

Must be compatible with existing, Government owned high pressure lances currently being used in the SHR27 Must be rated to at least 15k psi.

CLIN 0007: 2117-3758

DESCRIPTION:

“Home” setting go/no go gauge

This part will be used to make complete existing kits and restock on hand material for the SHR27, a Government owned and proprietary Heat Exchanger Cleaning tool. It will be used for the emergent and planned repair of the SHR-27.

Must be compatible with the SHR27 Smart Feed/Plug detection assembly.

Must be about 6”x1/2”x1/2” while allowing for the quick and accurate setting of the

“Home” sensor during the setup of the associated Heat Exchanger Cleaning systems.

Must be lightweight.

Must be marked with appropriate part number and nomenclature consistent with existing units owned by PSNS.