S02. Request For Quotes 36C26323Q0800.pdf

PDF 692 KB Posted

Attached to
6515--Supply - Vyaire Brand Pulmonary Function Testing Equipment VISN23 Federal contract opportunity
Solicitation number
36C26323Q0800
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 23

About this file

This is a solicitation for Vyaire brand pulmonary function testing equipment for Veterans Integrated Service Network 23. The solicitation requests quotes for Vyaire PFT and spirometry equipment including hardware, software, and related items. The selected vendor must provide all equipment, materials, design services, installation, implementation, training and incidental items to fully implement the equipment at seven Veterans Health Administration facilities within 90 calendar days of award. The solicitation includes pricing tables detailing the required equipment, quantities, and delivery locations.

View the file

Other files for this federal contract opportunity

Other files attached to 6515--Supply - Vyaire Brand Pulmonary Function Testing Equipment VISN23, newest first.
File Type Posted
36C26323Q0800_2.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PAGE 1 OF 1. REQUISITION NO.

2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NO. 5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE

a. NAME b. TELEPHONE NO. (No Collect Calls) 8. OFFER DUE DATE/LOCAL

TIME

9. ISSUED BY CODE 10. THIS ACQUISITION IS UNRESTRICTED OR SET ASIDE: % FOR:

SMALL BUSINESS

HUBZONE SMALL

BUSINESS

SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

WOMEN-OWNED SMALL BUSINESS

(WOSB) ELIGIBLE UNDER THE WOMEN-OWNED

SMALL BUSINESS PROGRAM

EDWOSB

8(A)

NAICS:

SIZE STANDARD:

11. DELIVERY FOR FOB DESTINA-

TION UNLESS BLOCK IS

MARKED

SEE SCHEDULE

12. DISCOUNT TERMS

13a. THIS CONTRACT IS A

RATED ORDER UNDER

DPAS (15 CFR 700)

13b. RATING

14. METHOD OF SOLICITATION

RFQ IFB RFP

15. DELIVER TO CODE 16. ADMINISTERED BY CODE

17a. CONTRACTOR/OFFEROR CODE FACILITY CODE 18a. PAYMENT WILL BE MADE BY CODE

TELEPHONE NO. UEI: EFT:

PHONE: FAX:

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT SUCH ADDRESS IN OFFER

18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK BELOW IS CHECKED

SEE ADDENDUM

19. 20. 21. 22. 23. 24.

ITEM NO. SCHEDULE OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

(Use Reverse and/or Attach Additional Sheets as Necessary)

25. ACCOUNTING AND APPROPRIATION DATA 26. TOTAL AWARD AMOUNT (For Govt. Use Only)

27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1, 52.212-4. FAR 52.212-3 AND 52.212-5 ARE ATTACHED. ADDENDA ARE ARE NOT ATTACHED.

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN _______________ 29. AWARD OF CONTRACT: REF. ___________________________________ OFFER COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND DATED ________________________________. YOUR OFFER ON SOLICITATION DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY (BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED SET FORTH HEREIN IS ACCEPTED AS TO ITEMS:

30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER)

30b. NAME AND TITLE OF SIGNER (TYPE OR PRINT) 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER (TYPE OR PRINT) 31c. DATE SIGNED

AUTHORIZED FOR LOCAL REPRODUCTION (REV. NOV 2021)

PREVIOUS EDITION IS NOT USABLE Prescribed by GSA - FAR (48 CFR) 53.212

7. FOR SOLICITATION

INFORMATION CALL:

STANDARD FORM 1449

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES

OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, & 30

499-23-4-6720-0029

36C26323Q0800 09-06-2023

Curt LaRose 605-592-4026 09-11-2023 08:00am CDT

Department of Veterans Affairs

NETWORK 23 CONTRACTING OFFICE

2501 W. 22nd St.

Sioux Falls SD 57105

X

339112

1000 Employees

N/A

X

VA Medical & Regional Office Center

NETWORK 23 CONTRACTING OFFICE

VA Medical & Regional Office Center

See CONTINUATION Page

Contractor shall provide all labor, transportation, and equipment listed in the Price/Cost Schedule.

See CONTINUATION Page

499-3630160-6720-820100-3131-010065275 499-23-4-6720-0029

X X

X ONE

Curt LaRose

VHA-RPOC-2021-17

36C26323Q0800

Table of Contents

SECTION A

A.1 SF 1449 SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL PRODUCTS

AND COMMERCIAL SERVICES

SECTION B - CONTINUATION OF SF 1449 BLOCKS

B.1 CONTRACT ADMINISTRATION DATA

B.2 STATEMENT OF WORK

B.3 PRICE/COST SCHEDULE

ITEM INFORMATION

B.4 DELIVERY SCHEDULE

SECTION C - CONTRACT CLAUSES

C.1 52.212-4 CONTRACT TERMS AND CONDITIONS—COMMERCIAL PRODUCTS

AND COMMERCIAL SERVICES (DEC 2022)

C.2 VAAR 852.232-72 ELECTRONIC SUBMISSION OF PAYMENT REQUESTS (NOV

2018)

C.3 VAAR 852.242-71 ADMINISTRATIVE CONTRACTING OFFICER (OCT 2020)

C.4 VAAR 852.247-73 PACKING FOR DOMESTIC SHIPMENT (OCT 2018)

C.5 52.252-2 CLAUSES INCORPORATED BY REFERENCE (FEB 1998)

C.6 52.212-5 CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT

STATUTES OR EXECUTIVE ORDERS—COMMERCIAL PRODUCTS AND

COMMERCIAL SERVICES (JUN 2023)

SECTION D - CONTRACT DOCUMENTS, EXHIBITS, OR ATTACHMENTS

SECTION E - SOLICITATION PROVISIONS

E.1 52.212-1 INSTRUCTIONS TO OFFERORS—COMMERCIAL PRODUCTS AND

COMMERCIAL SERVICES (MAR 2023)

E.2 52.204-24 REPRESENTATION REGARDING CERTAIN TELECOMMUNICATIONS

AND VIDEO SURVEILLANCE SERVICES OR EQUIPMENT (NOV 2021)

E.3 52.209-7 INFORMATION REGARDING RESPONSIBILITY MATTERS (OCT 2018)

E.4 52.216-1 TYPE OF CONTRACT (APR 1984)

E.5 52.233-2 SERVICE OF PROTEST (SEP 2006)

E.6 VAAR 852.233-71 ALTERNATE PROTEST PROCEDURE (OCT 2018)

E.7 52.252-1 SOLICITATION PROVISIONS INCORPORATED BY REFERENCE (FEB

1998)

E.8 52.212-2 EVALUATION—COMMERCIAL ITEMS (OCT 2014)

E.9 52.212-3 OFFEROR REPRESENTATIONS AND CERTIFICATIONS—

COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES (DEC 2022)

SECTION B - CONTINUATION OF SF 1449 BLOCKS

B.1 CONTRACT ADMINISTRATION DATA

1. Contract Administration: All contract administration matters will be handled by the following individuals:

a. CONTRACTOR:

b. GOVERNMENT: Contracting Officer 36C263

NETWORK 23 CONTRACTING OFFICE

2501 W. 22nd St.

Sioux Falls SD 57105

2. CONTRACTOR REMITTANCE ADDRESS: All payments by the Government to the contractor will be made in accordance with:

[X] 52.232-33, Payment by Electronic Funds Transfer—System For Award

Management, or [] 52.232-36, Payment by Third Party

3. INVOICES: Invoices shall be submitted in arrears:

a. Quarterly []

b. Semi-Annually []

c. Other [X] Upon receipt

4. GOVERNMENT INVOICE ADDRESS: All Invoices from the contractor shall be submitted electronically in accordance with VAAR Clause 852.232-72 Electronic Submission of Payment Requests.

5. ACKNOWLEDGMENT OF AMENDMENTS: The offeror acknowledges receipt of amendments to the Solicitation numbered and dated as follows:

AMENDMENT NO DATE

B.2 STATEMENT OF WORK

Vyaire PFT and Spirometry Equipment

1. SCOPE: Vendor must provide Vyaire PFT and Spirometry Equipment and services per quotes. The selected vendor will be responsible for providing any installation services required to complete this project. These services include, but are not limited to, system design, project management, both onsite and remote installation services, clinical training, and go live support services. This also includes supporting the network configuration of this equipment including integration with the VISN wide servers and patient record. Travel to and from the place of performance shall also be included in the contractor’s proposal. All installation, training and implementation services are to be performed at the following VISN 23 facilities and/or affiliated CBOCs – Nebraska-Western Iowa Veterans Health System (VHS), Minneapolis VHS, Iowa City VHS, Central Iowa VHS, Fargo VHS, Sioux Falls VHS, and St. Cloud VHS.

2. QUALIFICATIONS: To be eligible for consideration, vendor must be able to provide Vyaire PFT and spirometry system hardware and software components, as required by the attached summaries. The vendor must either be the OEM or be authorized by the OEM to provide this specific equipment (hardware and software) and also work to integrate this new equipment with the existing VISN wide Vyaire servers. The selected vendor will be responsible for providing any installation services (travel included) required to complete this project. These services include, but are not limited to, system design, project management, both onsite and remote installation services, clinical training, and go live support services.

3. SERVICES TO BE PROVIDED: To be considered eligible for consideration, vendor must provide all equipment, materials, design services, installation labor, implementation services, training and incidental materials/labor/services to fully implement the Vyaire PFT and spirometry equipment detailed in the attached quote at 7 VISN 23 Veterans Health Systems.

B.3 PRICE/COST SCHEDULE

ITEM INFORMATION

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

1.00 EA __________________ __________________

FILLING CONNECTION HI/LO FIO2, Assembly to fit between filling bag and gas source OMAHA - 1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies

LOCAL STOCK NUMBER: 706823

HANS RUDOLPH INHALER ADAPTER, Adapter between

Filling Bag and HR Y-Valve OMAHA - 1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 707146

11.00 EA __________________ __________________

SYRINGE 3 LITER MANUAL CALIBRATION CENTRAL

IOWA - 1; SIOUX FALLS - 5; FARGO - 1; ST. CLOUD - 2;

MINNEAPOLIS - 2

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 720254

8.00 EA __________________ __________________

POWER CORD HOSPITAL GRADE IOWA CITY - 1;

CENTRAL IOWA - 1; OMAHA - 3; FARGO - 1; ST. CLOUD

- 1; MINNEAPOLIS - 1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 760707

2.00 EA __________________ __________________

GAS- 99.00% OXYGEN(USP) CENTRAL IOWA - 1;

MINNEAPOLIS - 1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 761819

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

DISPOSABLE NOSE CLIPS PK 100 Noseclips, disposable pack of 100 MINNEAPOLIS - 1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 761889

27.00 EA __________________ __________________

GAS .3%CO .3%CH4 21%02 BAL N2 (ED) IOWA CITY - 3;

CENTRAL IOWA - 3; OMAHA - 3; FARGO - 1; ST. CLOUD

- 1; MINNEAPOLIS - 16

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 768093

GAS 16%O2 4%CO2 BAL N2 8D CYL OMAHA - 1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 773867

BREATHING BAGS 20L 30PK, Pack of 30 20L filling bags

OMAHA - 1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 852828

ITGV SIMULATOR IOWA CITY - 1; CENTRAL IOWA - 1;

OMAHA - 3; FARGO - 1; ST. CLOUD - 1; MINNEAPOLIS -1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 001-375420

3.00 EA __________________ __________________

NONIN 3150 FLEX WRAP (25) MINNEAPOLIS - 3

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 22012-001

ITEM

NUMBER

DESCRIPTION OF

9.00 EA __________________ __________________

3150 WRIST BAND MINNEAPOLIS - 9

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 22989-001

"SES LAPTOP PC Dell Latitude 5520 with Windows 10 Pro

64 bit. Intel Core i5-1145G7 (4 Core, 8M cache, base 2.6GHz, up to 4.4GHz, vPro). 15.6 inch FHD (1920x1080) Non-Touch, Anti-Glare, 250nits. 16GB 2X8GB DDR4 Non- ECC. M.2 256GB PCIe NVMe Class 35 Solid State Drive.

Intel Wi-Fi 6 AX201 2x2 .11ax 160MHz + Bluetooth 5.1.

This laptop has 3 USB ports. We are also including a 4 port StarTech USB3.0 Hub which that will connect to the Type-C port on the computer. This gives a total of 7 USB ports.

There is no RS232 Serial port connections supported."

SIOUX FALLS -1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 23666-610

6.73 GE OPTION, PDF REPORT PDF report creation and

export: Auto-formats selected or customized final reports into PDF documents for storage, archiving or offline use.

(EPDF) CENTRAL IOWA - 1; OMAHA - 1; MINNEAPOLIS -

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: F23884-001

DELL COLOR LASER PRINTER DELL COLOR LASER

C1760NW ST. CLOUD - 1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 23987-001

6.00 EA __________________ __________________

VYNTUS SPIRO LAPTOP. PC Based Spirometer with direct USB connection to Laptop Computer. Validated Windows 10 Laptop Computer Included. Vyntus Spiro performs all the essential spirometry tests; FVC with Flow

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

Volume Loop, Slow Vital Capacity (SVC), Maximum Voluntary Ventilation ( MVV). Pre and Post Bronchodilator testing levels and Bronchial Challenge Testing software also included. SentrySuite software provides user guidance and feedback regarding test quality according to ATS/ERS or other author's standards. Other software features included; powerful report designer, 10 parameter-linked animated incentives, interactive guided calibration, customizable reference modules, and offline data entry.

Device can be used as standalone or can take advantage of our growing family of SentrySuite solutions for workflow and connectivity such as Sentry.Net and SentryConnect. Box of 80 Microgard filters included. 1 year complete warranty with 4 additional years of advanced product and technical support CENTRAL IOWA -1; SIOUX FALLS -4;

MINNEAPOLIS -1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 25626-001

VMAX VYNTUS SPIRO DESKTOP. PC Based Spirometer with direct USB connection to Desktop PC. Validated Windows 10 Desktop PC, 22" MONITOR and Sound Bar Included. Vmax Vyntus Spiro performs all the essential spirometry tests; FVC with Flow Volume Loop, Slow Vital Capacity (SVC), Maximum Voluntary Ventilation ( MVV).

Pre and Post Bronchodilator testing levels and Bronchial Challenge Testing software also included. SentrySuite software provides user guidance and feedback regarding test quality according to ATS/ERS or other author's standards. Other software features included; powerful report designer, 10 parameter-linked animated incentives, interactive guided calibration, customizable reference modules, and offline data entry. Device can be used as standalone or can take advantage of our growing family of SentrySuite solutions for workflow and connectivity such as Sentry.Net and SentryConnect. Box of 80 Microgard filters included. 1 year complete warranty with 4 additional years of product and technical support FARGO -1;

MINNEAPOLIS -1;

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 25627-001

NONIN 3150 ADAPTER, 9PIN SPO2 PROBES

MINNEAPOLIS -3

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 28439-001

34.00 EA __________________ __________________

SES CLIENT Device to be configured as a network client

IOWA CITY - 3; CENTRAL IOWA - 3; SIOUX FALLS - 5;

OMAHA - 3; FARGO -3; ST. CLOUD -3; MINNEAPOLIS -

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 28567-001

REUSABLE REFLECTANCE SENSOR MINNEAPOLIS - 3

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 28897-001

BOX, APPLICATOR CAPS (10)/ADH RINGS(20)

MINNEAPOLIS -3

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 28898-001

KIT, VYNTUS WALK Tablet application for six minute walk test (6MWT) using wearable, wireless sensors connected to a tablet PC running AndroidT Operating System with a workflow driven protocol meeting the 2014 ATS/ERS guidelines. Includes 1 x 7 inch Android Tablet with Vyntusr Walk application, 1 x Noninr 3150 WristOx Bluetooth oximeter, 1 x 3150 Soft Sensor, medium, 1 x 3150 Flexible adult sensor, 1 x 3150 Flex Wrap pack of 25, 1 x SpO2 Ear Clip sensor, 1 x Reusable Reflectance sensor, 1 x Box of Applicator caps (10) with Adhesive Rings (20), 1 x 3150 Adapter, 9 Pin for probes, 1x SentrySuiter Reading Station software license, and 1 x Power adapter. Vyntus Walk comes with a 2 year warranty on device plus 3 additional years of product & technical support MINNEAPOLIS -3 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

LOCAL STOCK NUMBER: 28899-001

10.00 EA __________________ __________________

KIT,OFFICE JET PRINTER CENTRAL IOWA -1; SIOUX

FALLS -5; FARGO - 1; ST. CLOUD -1; MINNEAPOLIS -2

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 29225-001

VYNTUS CPX CARDIOSOFT ECG BIG CINEMA. Vmax

Vyntus CPX metabolic cart system for the measurement of O2, CO2 and associated parameters combined with Cardiosoft Stress 12-lead ECG. System includes: 1 Vmax Vyntus CPX analyzer module, 1 Cardiosoft 12-Lead ECG, 1 Nonin SpO2 (with reflectance, earclip, and adult and pediatric finger sensors), 1 3.0 cart with medical grade isolation transformer, 1 validated Win 10 PC, 1 34 inch curved monitor, 1 Dell color laser printer kit, 1 receiver for Polar HR (Polar belt not included), 1 ambient module, 1 regulator, 2 complete DVT volume sensors (transducer and volume sensor insert), 2 additional volume sensor inserts, 4 Twin Tube bxb sample lines, 2 Hans Rudolph 7450 Oro Nasal face masks (S and M), 1 SentrySuite software with MS SQL Server Software 2014 and license code sheet, nose clips, and 2 boxes MicroGard 2 filters (50 ea.). 2 years Premium Care warranty with 4 additional years of VYNTUS accessories product and techincal support; and 3 additional years of advancedVYNTUS CPX product and technical support OMAHA -1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 29820-001

CARDIOSOFT ECG FOR VYNTUS. 1 year warranty with 4 additional years of VYNTUS Accessories product and technical support CENTRAL IOWA -1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 29838-001

BLOOD PRESSURE CUFF,LARGE, Arm circumference 32

- 42 cm / 15.5 cm wide CENTRAL IOWA -1;

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

MINNEAPOLIS-1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 30242-001

BLOOD PRESSURE CUFF,SMALL, Arm circumference 17

- 26 cm / 9 cm wide CENTRAL IOWA - 1; MINNEAPOLIS - PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 30243-001

VIASPRINT BIKE WITH BP AND CUFFS.

Electromagnetically-braked bicycle ergometer especially designed for exercise tests with integrated blood pressure.

Load 20-999 watts, revolution range 30-130 rpm, and integrated isolation transformer. 3 cuff sized are supplied-small, standard, and large. Blood pressure may be initiated via software or manually from display unit head. Manual adjustment of saddle height from 120-210 cm and adjustable handle bar. Dimensions (L 35.4 inch x W 18.1 inch x H 52.4 inch), bike weight 134.5 lbs., power supply 90- 264V. The ergometer is certified for a maximum weight of 308 lbs. CENTRAL IOWA -1; MINNEAPOLIS -1;

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 30244-001

AMBU BLUESENSOR R ECG ELECTRODE SNGL USE,

Pack of 25 CENTRAL IOWA -1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 31439-001

VYNTUS ONE PC System for PFT and CPET testing.

Includes analyzer module (O2, CO2, Multigas), breathing circuit (including Ultrasonic sensor, Flow Path Valve, Demand Valve, and DVT sensor, 2 bxb sample lines), built-in pulse oximeter (finger, forehead and ear clip sensors included), 2 Hans Rudolph 7450 Oro Nasal face masks (S

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

and M), SentrySuite software, standard cart and arm with adjustable height and left/right mousepad, validated WIN 10 PC with sanitizable medical keyboard/mouse, 34 inch flat panel monitor, Office Jet printer, 3-L manual syringe, O2, DLCO and calibration gas regulators, 6 cylinder gas stand, 1 box of MicroGard IIB and IIC (80 each) filters. Tests performed: Spirometry (FVC, SVC, MVV), Lung subdivisions (FRC-N2, RV, TLC), Real-time DLCO (both Single Breath and Intrabreath, MIP/ MEP, pre/post bronchodilator, and CPET (O2, CO2, VE, thresholds and slopes, compare tests). Standard software includes:

Guidance and Stabilitrac instructional applications, pre-formatted reports and reference sets with design tools for modification, automated interpretation algorithms, QA checks and physician interpretation templates, CPET screen layout and protocol editor. 1st year warranty included. CENTRAL IOWA -1;

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 31776-001

VYNTUS ONE PC System for PFT and CPET testing.

Includes analyzer module (O2, CO2, Multigas), breathing circuit (including Ultrasonic sensor, Flow Path Valve, Demand Valve, and DVT sensor, 2 bxb sample lines), built-in pulse oximeter (finger, forehead and ear clip sensors included), 2 Hans Rudolph 7450 Oro Nasal face masks (S and M), SentrySuite software, standard cart and arm with adjustable height and left/right mousepad, validated WIN 10 PC with sanitizable medical keyboard/mouse, 34 inch flat panel monitor, Office Jet printer, 3-L manual syringe, O2, DLCO and calibration gas regulators, 6 cylinder gas stand, 1 box of MicroGard IIB and IIC (80 each) filters. Tests performed: Spirometry (FVC, SVC, MVV), Lung subdivisions (FRC-N2, RV, TLC), Real-time DLCO (both Single Breath and Intrabreath, MIP/MEP, pre/post bronchodilator, and CPET (O2, CO2, VE, thresholds and slopes, compare tests). Standard software includes:

Guidance and Stabilitrac instructional applications, pre-formatted reports and reference sets with design tools for modification, automated interpretation algorithms, QA checks and physician interpretation templates, CPET screen layout and protocol editor. 1 year warranty plus 4 additional years of premium product & technical support

MINNEAPOLIS -1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing

ITEM

NUMBER

DESCRIPTION OF

LOCAL STOCK NUMBER: 31776-001

14.00 EA __________________ __________________

VYNTUS ONE-DL PC System. Includes analyzer module, breathing circuit (including Ultrasonic sensor, Flow Path Valve, and Demand Valve), SentrySuite software, standard cart and arm with adjustable height and left/ right mousepad, validated WIN 10 PC with sanitizable medical keyboard/ mouse, 27 flat panel infinity-edge monitor, Office Jet printer, 3-L manual syringe, DLCO and calibration gas regulators, 6 cylinder gas stand, 1 box of MicroGard IIB and IIC (80 each) filters. Tests performed: Spirometry (FVC, SVC, MVV), Real-time DLCO (both Single Breath and Intrabreath), MIP/MEP, pre/post bronchodilator. Standard software includes: Guidance and Stabilitrac instructional applications, pre-formatted reports and reference sets with design tools for modification, automated interpretation algorithms, QA checks and physician interpretation templates. 1 year warranty with 4 additional years of premium product and technical support MINNEAPOLIS -14 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 31790-001

VYNTUS ONE-DL PC System. Includes analyzer module, breathing circuit (including Ultrasonic sensor, Flow Path Valve, and Demand Valve), SentrySuite software, standard cart and arm with adjustable height and left/ right mousepad, validated WIN 10 PC with sanitizable medical keyboard/ mouse, 27 flat panel infinity-edge monitor, Office Jet printer, 3-L manual syringe, DLCO and calibration gas regulators, 6 cylinder gas stand, 1 box of MicroGard IIB and IIC (80 each) filters. Tests performed: Spirometry (FVC, SVC, MVV), Real-time DLCO (both Single Breath and Intrabreath), MIP/MEP, pre/post bronchodilator. Standard software includes: Guidance and Stabilitrac instructional applications, pre-formatted reports and reference sets with design tools for modification, automated interpretation algorithms, QA checks and physician interpretation templates. 1 year warranty included. IOWA CITY -1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 31790-0011

VYNTUS BODY PC Diffusion System. Includes 1110L body plethysmograph with 551 pound patient bench and 25 inch

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

telescoping arm, breathing circuit (including Ultrasonic sensor, Flow Path Valve, and Demand Valve), SentrySuite software, validated WIN 10 PC with sanitizable medical keyboard/mouse, 27 inch flat panel monitor, Office Jet printer, 3-L manual syringe, DLCO pressure regulator, 6 cylinder gas stand, box of 80 MicroGard IIB filters. Tests performed: Spirometry (FVC, SVC, MVV), Lung subdivisions (VTG, FRCpl, RV, TLC, Raw, Conductance and specific resistance and Resistance Volume Loops), Real-time DLCO (both Single Breath and Intrabreath, MIP/MEP, and pre/post bronchodilator. Standard software includes: Guidance and Stabilitrac instructional applications, pre-formatted reports and reference sets with design tools for modification, automated interpretation algorithms, QA checks and physician interpretation templates. 1 year warranty with 4 additional years of adavanced product and technical support CENTRAL IOWA -1; FARGO -2 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 31797-001

4.00 EA __________________ __________________

plethysmograph with 551 pound patient bench and 25 inch telescoping arm, breathing circuit (including Ultrasonic sensor, Flow Path Valve, and Demand Valve), SentrySuite software, validated WIN 10 PC with sanitizable medical keyboard/mouse, 27 inch flat panel monitor, Office Jet printer, 3-L manual syringe, DLCO pressure regulator, 6 cylinder gas stand, box of 80 MicroGard IIB filters. Tests performed: Spirometry (FVC, SVC, MVV), Lung subdivisions (VTG, FRCpl, RV, TLC, Raw, Conductance and specific resistance and Resistance Volume Loops), Real-time DLCO (both Single Breath and Intrabreath, MIP/MEP, and pre/post bronchodilator. Standard software includes: Guidance and Stabilitrac instructional applications, pre-formatted reports and reference sets with design tools for modification, automated interpretation algorithms, QA checks and physician interpretation templates. 1 year warranty with 4 additional years of advanced product and technical support OMAHA -3; ST. CLOUD -1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical plethysmograph with 551 pound patient bench and 25 inch

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

telescoping arm, breathing circuit (including Ultrasonic sensor, Flow Path Valve, and Demand Valve), SentrySuite software, validated WIN 10 PC with sanitizable medical keyboard/mouse, 27 inch flat panel monitor, Office Jet printer, 3-L manual syringe, DLCO pressure regulator, 6 cylinder gas stand, box of 80 MicroGard IIB filters. Tests performed: Spirometry (FVC, SVC, MVV), Lung subdivisions (VTG, FRCpl, RV, TLC, Raw, Conductance and specific resistance and Resistance Volume Loops), Real-time DLCO (both Single Breath and Intrabreath, MIP/MEP, and pre/post bronchodilator. Standard software includes: Guidance and Stabilitrac instructional applications, pre-formatted reports and reference sets with design tools for modification, automated interpretation algorithms, QA checks and physician interpretation templates. 1st year warranty plus 4 additional years of premium product and technical support MINNEAPOLIS -1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical plethysmograph with 551 pound patient bench and 25 inch telescoping arm, breathing circuit (including Ultrasonic sensor, Flow Path Valve, and Demand Valve), SentrySuite software, validated WIN 10 PC with sanitizable medical keyboard/mouse, 27 inch flat panel monitor, Office Jet printer, 3-L manual syringe, DLCO pressure regulator, 6 cylinder gas stand, box of 80 MicroGard IIB filters. Tests performed: Spirometry (FVC, SVC, MVV), Lung subdivisions (VTG, FRCpl, RV, TLC, Raw, Conductance and specific resistance and Resistance Volume Loops), Real-time DLCO (both Single Breath and Intrabreath, MIP/MEP, and pre/post bronchodilator. Standard software includes: Guidance and Stabilitrac instructional applications, pre-formatted reports and reference sets with design tools for modification, automated interpretation algorithms, QA checks and physician interpretation templates. 1 year warranty with 4 additional years of advanced product and technical support IOWA CITY -2 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

VYNTUS BODY DIFF ADD Diffusion system, no PC, no cart. System will connect to shared computer and license of

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

SentrySuite. Includes: 1110L body plethysmograph with 551 pound patient bench and 25 inch telescoping arm, breathing circuit (including Ultrasonic sensor, Flow Path Valve, and Demand Valve), SentrySuite software, 3-L manual syringe, DLCO pressure regulator. On board analyzers to perform in box: Spirometry (FVC, SVC, MVV), Lung subdivisions (VTG, FRCpl, RV, TLC, Raw, Conductance and specific resistance and Resistance Volume Loops), Real-time DLCO (both Single Breath and Intrabreath), MIP/MEP, and pre/post bronchodilator. 1 year warranty with 4 additional years of advanced product and technical support

CENTRAL IOWA -1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 31803-001

17.00 EA __________________ __________________

Additional Breathing Circuit for Vyntus ONE. Includes: 1 each of USS Module with polytube adapter, Flow Path Valve, Shutter, and 1 pk of 5 Silicone Valves. IOWA CITY -

1; CENTRAL IOWA -1; MINNEAPOLIS -15

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 32924-001

14.00 EA __________________ __________________

Additional Breathing Circuit for Vyntus BODY. Includes: 1 each of USS Module with polytube adapter, Flow Path Valve, Shutter and 1 pk of 5 Silicone Valves. IOWA CITY -

2; CENTRAL IOWA -3; OMAHA -3; FARGO -2; ST. CLOUD

-2; MINNEAPOLIS -2

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 32925-001

"VYNTUS SPIRO PNEUMOTACH/ELBOW KIT

Annualpneumotach supply kit for Vyntus SPIRO. Contains 4 pneumotachs and 5 elbows." ST. CLOUD -2 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 33120-001

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

SENTRYSUITE WORKFLOW UPGRADE ST. CLOUD -1;

MINNEAPOLIS -1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 33284-002

"PROFESSIONAL SERVICES -- CUSTOMIZED REPORTS

(PACKOF 5) Provides a Vyaire Professional Services resource to create 5 custom reports within the existing environment. Limited to a single round of customization/revisions. Once the 5 customized reports are signed off by the facility, future revisions to those same reports will be subject to additional charges." CENTRAL

IOWA -1; MINNEAPOLIS -1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 33287-001

4.00 EA __________________ __________________

"PROFESSIONAL SERVICES HOURLY RATE Hourly rate forcustom Professional Services support." ST. CLOUD -4 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 33288-001

"34552-142 SERVICE-RDX-SM DEVICE PFT FUNDMTLS

TRG-2 DAYS-CUSTHOSTED Course Objectives: Perform pulmonary function testing; customize and configure system settings; perform system calibrations; understand and identify factors that will affect test accuracy; generate results and reports; perform basic troubleshooting and system maintenance; operate the medical device and system properly, safely, and effectively; and understand the ATS Technical Standards and clinical best practices. This program covers up to 2 small PFT devices (e.g., Vyntus SPIRO, Vyntus WALK, MasterScreen PNEUMO, MasterScreen IOS) or 1 small PFT device and Bronchial Challenge Testing. If Bronchial Challenge Training is requested as a part of this program, it will cover the following objectives: know the difference between" SIOUX

FALLS -1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

LOCAL STOCK NUMBER: 34552-142

13.00 EA __________________ __________________

"34553-142 SERVICE-VYN-LG DEVICE PFT FUNDMTLS

TRG-2 DAYS-CUSTHOSTED Course Objectives:

Understand ATS/ERS Clinical Guidelines; perform diagnostic testing according to ATS/ERS standards;

customize and configure system settings; select appropriate pulmonary reference authors based on demographic data and tests performed; conduct biological and mechanical quality control measures including system calibrations;

identify factors that will affect test accuracy; use best practices to analyze results and generate reports; perform basic troubleshooting, system maintenance, and hygiene;

and operate the medical device and system properly, safely, and effectively. This program covers 1 large PFT device (e.g., Vyntus ONE, Vyntus ONE PFT, Vyntus BODY Plethysmograph, or Vyntus ONE DL). Provides training at a single customer location for up to 4 participants. Provides 14 AARC CRCE contact hours for 4 participants when training is purchased in conjunction with a new device.

Program includes participant access to Pre- training Modules and a 2-hour Post-Training Follow-up Call with the Clinical Educator, to take place 2-4 weeks following the class. This training program does not cover Bronchial Challenge testing." MINNEAPOLIS -13 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 34553-142

"34553-143 SERVICE-VYN-PFT FUNDMTLS TRG-3

DAYS-CUST HOSTED CourseObjectives: Perform pulmonary function testing; customize and configure system settings; perform system calibrations; understand and identify factors that will affect test accuracy; generate results and reports; perform basic troubleshooting and system maintenance; operate the medical device and system properly, safely, and effectively; and understand the ATS Technical Standards and clinical best practices. This program covers up to 5 PFT devices (e.g., Vyntus ONE, Vyntus ONE PFT, Vyntus BODY Plethysmograph, Vyntus ONE DL, Vyntus SPIRO, Vyntus WALK, MasterScreen PNEUMO, and MasterScreen IOS) or 4 PFT devices and Bronchial Challenge Testing. If Bronchial Challenge Training is requested as a part of this program, it will cover the following objectives: know the difference between direct and indirect provocation methods; understand ATS/ERS Clinical Guidelines; perform bronchial challenge testing

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

according to ERS standards; customize and configure system settings; select appropriate pulmonary reference authors based on demographic data and tests performed;

conduct biological and mechanical quality control measures including system calibrations; identify factors that will affect test accuracy; use best practices to analyze results and generate reports; and perform basic troubleshooting, system maintenance, and hygiene. Provides training at a single customer location for up to 4 participants. Provides 21 AARC CRCE contact hours for 4 participants when training is purchased in conjunction with a new device.Program includes participant access to Pre-training Modules and a 2-hour Post-Training Follow-up Call with the Clinical Educator, to take place 2-4 weeks following the class." IOWA CITY -2; OMAHA -3; FARGO -1; ST. CLOUD

-1; MINNEAPOLIS -1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 34553-143

"34553-144 SERVICE-VYN-PFT FUNDMTLS TRG-4

DAYS-CUST HOSTED CourseObjectives: Perform pulmonary function testing; customize and configure system settings; perform system calibrations; understand and identify factors that will affect test accuracy; generate results and reports; perform basic troubleshooting and system maintenance; operate the medical device and system properly, safely, and effectively; and understand the ATS Technical Standards and clinical best practices. This program covers up to 5 PFT devices (e.g., Vyntus ONE, Vyntus ONE PFT, Vyntus BODY Plethysmograph, Vyntus ONE DL, Vyntus SPIRO, Vyntus WALK, MasterScreen PNEUMO, and MasterScreen IOS) or 4 PFT devices and Bronchial Challenge Testing. If Bronchial Challenge Training is requested as a part of this program, it will cover the following objectives: know the difference between direct and indirect provocation methods; understand ATS/ERS Clinical Guidelines; perform bronchial challenge testing according to ERS standards; customize and configure system settings; select appropriate pulmonary reference authors based on demographic data and tests performed;

conduct biological and mechanical quality control measures including system calibrations; identify factors that will affect test accuracy; use best practices to analyze results and generate reports; and perform basic troubleshooting, system maintenance, and hygiene. The fourth day of training provides participants with a supplemental training day for additional side-by-side practice with the Clinical Educator. This Program provides training at a single

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

customer location for up to 4 participants and 28 AARC CRCE contact hours for each of the 4 participants when training is purchased in conjunction with a new device.

Program includes participant access to Pre- training Modules and a 2-hour Post-Training Follow-up Call with the Clinical Educator, to take place 2-4 weeks following the class." CENTRAL IOWA -1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 34553-144

"34554-142 SERVICE-VYN-CPET FUNDMTLS TRG-2

DAYS-CUST HOSTEDCourse Objectives: Understand American Heart Association (AHA) and American College of Sports Medicine (ACSM) testing guidelines; perform cardiopulmonary exercise testing according to national standards; customize and configure system settings; select appropriate test protocol based on reference data and patient history; conduct biological and mechanical quality control measures including system calibrations; identify factors that will affect test accuracy; use best practices to analyze results and generate reports; perform basic troubleshooting, system maintenance, and hygiene; and operate the medical device and system properly, safely, and effectively. This program covers 1 CPET device (e.g., Vyntus ONE or Vyntus CPX). Proficiency in cardiopulmonary exercise testing required. Provides training at a single customer location for up to 4 participants.

Provides 14 AARC CRCE contact hours for 4 participants when training is purchased in conjunction with a new device. Program includes participant access to Pre-training Modules and a 2-hour Post-Training Follow-up Call with the Clinical Educator, to take place 2-4 weeks following the class." MINNEAPOLIS -1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 34554-142

"34554-143 SERVICE-VYN-CPET FUNDMTLS TRG-3

DAYS-CUST HOSTEDCourse Objectives: Understand American Heart Association (AHA) and American College of Sports Medicine (ACSM) testing guidelines; perform cardiopulmonary exercise testing according to national standards; customize and configure system settings; select appropriate test protocol based on reference data and patient history; conduct biological and mechanical quality

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

control measures including system calibrations; identify factors that will affect test accuracy; use best practices to analyze results and generate reports; perform basic troubleshooting, system maintenance, and hygiene; operate the medical device and system properly, safely, and effectively. This program covers up to 5 CPET devices (e.g., Vyntus ONE or Vyntus CPX). Provides training at a single customer location for up to 4 participants. Provides 21 AARC CRCE contact hours for 4 participants when training is purchased in conjunction with a new device. Program includes participant access to Pre-training Modules and a 2-hour Post-Training Follow- up Call with the Clinical Educator, to take place 2-4 weeks following the class."

CENTRAL IOWA -1; OMAHA -1;

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 34554-143

"34558-131 SERVICE-RDX-SM DEVICE PFT FUNDMTLS

TRG-1 DAY-LIVE WEBBASED Course Objectives: Perform pulmonary function testing; customize and configure system settings; perform system calibrations; understand and identify factors that will affect test accuracy; generate results and reports; perform basic troubleshooting and system maintenance; operate the medical device and system properly, safely, and effectively; and understand the ATS Technical Standards and clinical best practices. This program covers 1 small PFT device (e.g., Vyntus SPIRO, Vyntus WALK, MasterScreen PNEUMO, MasterScreen IOS). Provides live, web-based training for a single location and up to 3 participants. Provides 7 AARC CRCE contact hours for 3 participants when training is purchased in conjunction with a new device.Program includes participant access to Pre-training Modules and a 2-hour Post-Training Follow-up Call with the Clinical Educator, to take place 2-4 weeks following the class. This training program does not cover Bronchial Challenge testing." MINNEAPOLIS -1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 34558-131

"34558-132 SERVICE-RDX-SM DEVICE PFT FUNDMTLS

TRG-2 DAYS-LIVE WEBBASED Course Objectives:

Perform pulmonary function testing; customize and configure system settings; perform system calibrations;

understand and identify factors that will affect test accuracy;

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

generate results and reports; perform basic troubleshooting and system maintenance; operate the medical device and system properly, safely, and effectively; and understand the ATS Technical Standards and clinical best practices. This program covers up to 2 small PFT devices (e.g., Vyntus SPIRO, Vyntus WALK, MasterScreen PNEUMO, MasterScreen IOS) or 1 small PFT device and Bronchial Challenge Testing. If Bronchial Challenge Training is requested as a part of this program, it will cover the following objectives: know the difference between direct and indirect provocation methods; understand ATS/ERS Clinical Guidelines; perform bronchial challenge testing according to ERS standards; customize and configure system settings;

select appropriate pulmonary reference authors based on demographic data and tests performed; conduct biological and mechanical quality control measures including system calibrations; identify factors that will affect test accuracy;

use best practices to analyze results and generate reports;

and perform basic troubleshooting, system maintenance, and hygiene. Provides live, web-based training for a single location and up to 3 participants. Provides 14 AARC CRCE contact hours for 3 participants when training is purchased in conjunction with a new device. Program includes participant access to Pre-training Modules and a 2-hour Post-Training Follow-up Call with the Clinical Educator, to take place 2-4 weeks following the class." ST. CLOUD -1 PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 34558-132

"SERVICE-RDX-CUSTOM TRG SUPPORT-4 DAYS-

CUSTHOSTED. This is a custom designed 4-day customer hosted training event allowing the customer to work with the Vyaire education team to produce a flexible training event based on the customer's requirements. Included with the training is a pre-class consultation to build a customer agenda." CENTRAL IOWA -1; SIOUX FALLS -1; FARGO - PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 34568-144

LAPTOP LOCK-KEYED SIOUX FALLS -5; ST. CLOUD -2;

MINNEAPOLIS -1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 34571-001

13.00 EA __________________ __________________

SERVICE-RDX-SM DEVICE FIELD INSTALL-1ST DEVICE

CENTRAL IOWA -1; SIOUX FALLS -5; FARGO -1; ST.

CLOUD -1; MINNEAPOLIS -5

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 34588-101

SERVICE-RDX-SM DEVICE FIELD INSTALL-ADDL

DEVICE SA CENTRAL IOWA -1; FARGO -1; ST. CLOUD -

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 34588-102

BLOOD PRESSURE CUFF, STANDARD, Arm circumference 24 - 32 cm / 13 cm wide CENTRAL IOWA -

1; MINNEAPOLIS -1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 34589-001

"VYNTUS BIOMEDICAL TRAINING 3 DAYS 1 PERSON

Biomedical TrainingCourse for 3 days with a Vyaire Biomedical Instructor held at the Vyaire Medical, Inc.

Training Facility for 1 attendee. Attendee will participate in both lecture and lab time designed to provide information to effectively troubleshoot problems, make necessary repairs and perform periodic maintenance. Travel and lodging are the responsibility of the course attendees. -Cancellation notice must be received from customer in writing (via email is acceptable) 15 business days prior to the confirmed start date of the Training Course, or the following fees will be assessed per the Vyaire Training Course cancellation policy.* *No fee applied if cancellation notice received from the Customer prior to 15 business days before the start date of the confirmed Training Course. *? the cost of purchased training cancellation fee applied if cancellation notice received from the Customer less than 15 business days, but

ITEM

NUMBER

DESCRIPTION OF

SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

prior to 5 business days, before start date of confirmed Training Course. *Full cost of purchased training cancellation fee applied if cancellation notice received from Customer less than 5 business days before start date of confirmed Training Course. The full cost of purchased training will also be applied to ""no shows"" by Customer when scheduled to attend training at Vyaire training facility.

-Training must be scheduled within 60 days of purchase date when sold as training only. When sold with a capital device sale, training must be scheduled within 60 days of expiration of warranty, or extended warranty if purchased.

Not to exceed 3 years from the original purchase date. "

IOWA CITY -2; CENTRAL IOWA -1; OMAHA -3; FARGO -

1; ST. CLOUD -2; MINNEAPOLIS -1;

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: 97075-VYN-YL

"OPTION HIGH/LOW FIO2 VYNTUS CPX, Hardware andsoftware kit includes software code sheet, 1 complete Hans Rudolph (HR) Y-Valve 2730, 1 DVT for Hi/Low FiO2, 1 HR Inhaler Adapter, 1 Filling Assembly, 1 of each (coupling hose from bag to gas tank, Reducing Nipple for hose to connect to bag or reducer, O-Ring D 18, Reducer Assembly, and O-Ring D 21), and 1 Breathing Bag 20L 30PK. Option does not include gas, regulator, or blender."

OMAHA -1

PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical

LOCAL STOCK NUMBER: V-375650

USB AMBIENT MODULE CENTRAL IOWA -1; SIOUX

FALLS -4; FARGO -1; ST. CLOUD -2; MINNEAPOLIS -2

PRINCIPAL NAICS CODE:…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .