RIVERA BEACH FIRE RESCUE SERVICE MULTIPLE ROOMS_Drawing Set_062123.pdf
PDF 17 MB Posted
- Attached to
- Audio Visual Technology Services State and local contract opportunity
- Solicitation number
- 1195-RFQ-25-4
- Issued by
- Palm Beach County, Florida
About this file
This document is an Audio Visual (AV) system design set of technical drawings for the Riviera Beach Fire Rescue facility located at 600 W Blue Heron Boulevard in Riviera Beach, Florida. The comprehensive set of 27 technical drawings details the audio-visual infrastructure for various spaces including offices, conference rooms, a bullpen area, work area, and break room. The drawings, prepared by AV-Worx and dated May and June 2023, provide precise technical specifications for display installations, equipment rack configurations, cable routing, and system connectivity. The design includes multiple display types such as 65", 75", and 86" displays from manufacturers like ViewSonic and Barco, strategically placed throughout the facility.
The AV system design incorporates sophisticated technology including video switchers, digital signal processors, ceiling microphones, cameras, speakers, and networked connectivity solutions. The equipment includes QSC video switchers, Shure wireless microphone systems, Extron digital transmission equipment, and networked audio-visual components designed to support flexible communication and presentation capabilities. The system appears to be comprehensively engineered to provide seamless audio-visual integration across different spaces, with particular emphasis on the bullpen area which features a complex video wall configuration. The drawings include detailed electrical and mounting specifications, cable schedules, system flow diagrams, and equipment rack elevation plans, indicating a highly structured and professional approach to the audio-visual system design.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment B Draft Contract.pdf | ||
| Attachment C Microsoft ASYS MTR Solutions App Guide.pdf | ||
| Attachment D - SBE Participation Schedule 1 and Schedule 2.pdf | ||
| Attachment D3 LDSCC AV Design Wiring v2.pdf | ||
| Attachment A Forms - Proposer Required Forms v2_2025.pdf | ||
| Q_A Document 1.pdf | ||
| Solicitation.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
ES
AV
-W
O R
X.
C
O M
A/V SYMBOL LEGEND
PERMANENT FURNISHINGS
DRAPERY/SHADE MOTOR LVC:
DRAPERY/SHADE MOTOR:
MOTORIZED DRAPES/SHADES
LIGHTING DIMMING LVC PROGRAMMED:
EQUIPMENT RACKS FOR MILLWORK:
ALL TELECOMMUNICATION PLATES:
WIRELESS ACCESS POINT FOR AV:
VOICE & DATA NETWORK (FOR AV USE)
CREDENZA VENTILATION:
MILLWORK/TABLE PENETRATIONS & MODIFICATIONS:
DRAPERY/SHADE MOTOR LVC CABLE TERMINATED:
POTS/ANALOG TELEPHONE SERVICE & TERMINATION:
PROJECTION SCREENS:
PROJECTOR/DISPLAY MOUNTS:
EQUIPMENT HARD POINTS:
PROJECTION SCREENS:
PROGRAM SPEAKERS:
ALL SPECIFIED BLOCKING:
FLAT PANEL MOUNTS:
FLAT PANEL DISPLAYS:
WALL MOUNTED EQUIPMENT
CEILING MICROPHONES:
ELECTRICAL (FOR AV USE)
CEILING MOUNTED EQUIPMENT
FLOOR BOX AND ACCESSORIES:
LIGHTING DIMMING EQUIPMENT:
LIGHTING DIMMING SYSTEMS
ALL AV WALL PLATES:
ALL AV CONNECTORS:
AV LOW VOLTAGE CABLES:
LIGHTING DIMMING LVC FOR AV INTERFACE:
AV ELECTRICAL CONDUITS & PULL STRINGS:
ALL AV ELECTRICAL OUTLETS AND JUNCTION BOXES:
INSTALLED BY:
RESPONSIBILITY SCHEDULE
E.
C
G .C
E.
C
G .C
T/ D
.C
C
LI
EN
T
SUPPLIED BY:
C
LI
EN
T
N /A
CAMERAS:
IP/NETWORK CONFIGURATION FOR VIDEO CONFERENCING:
IP/NETWORK CONFIGURATION FOR AV CONTROL:
AV EQUIPMENT RACKS
VoIP/SIP CONFIGURATION FOR AUDIO CONFERENCING:
PROJECTOR/DISPLAY:
SPEAKER HARDWARE & BACKBOX:
AV
C
T/ D
.C
AV
C
ALL COAX RF PLATES/CABLE/CONNECTIONS:
GENERAL NOTES
GENERAL ELECTRICAL NOTES:
· 120VAC SERVICES FOR EQUIPMENT RACKS AND VIDEO PROJECTORS TO SHARE THE SAME PHASE
· ALL TELE/DATA, NETWORK AND 120VAC CONVENIENCE OUTLETS INDICATED ON THESE DRAWINGS
ARE FOR COORDINATION PURPOSES ONLY. REFER TO COMMUNICATIONS AND POWER PLANS FOR
FULL TELE/DATA, NETWORK AND ELECTRICAL REQUIREMENTS.
· REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL LIGHTING CONTROL STATION LOCATIONS, 120VAC REQUIREMENTS AND LIGHTING REQUIREMENTS.
· COORDINATE FINAL LOCATIONS OF SWITCHES, AV-PLATES AND J-BOXES WITH WALL TREATMENT
AND SURFACES.
· ANY DISCREPANCIES OCCURRING BETWEEN THESE DOCUMENTS AND ELECTRICAL DOCUMENTS
ARE TO BE REFERRED TO THE ARCHITECT.
· ALL AC OUTLETS INDICATED ON THESE DRAWINGS ARE FOR AV PURPOSES. FOR ALL OTHER AC
NEEDS, REFER TO POWER PLANS.
· FINAL LOCATION AND COORDINATION OF ALL FLOOR BOXES TO BE VERIFIED IN FIELD WITH
ARCHITECT PRIOR TO INSTALLATION.
· REFER TO ELECTRICAL DRAWINGS FOR ALL POWER CIRCUITRY.
· UNLESS SPECIFIED, JUNCTION BOXES SHALL BE SIZED AS REQUIRED BY THE ELECTRICAL
CONTRACTOR.
· AV DRAWINGS, COMMUNICATIONS DRAWINGS, POWER PLAN DRAWINGS AND ARCHITECTURAL
DRAWINGS SHOULD BE CAREFULLY REVIEWED SIMULTANEOUSLY TO AVOID UNDER-COUNTING OR
OVER-COUNTING DEVICES AND MIS-LOCATING DEVICES.
· QUANTITIES GIVEN ON AV DETAIL PAGES AND AV ROOM SCHEDULE DRAWING (IF APPLICABLE) MUST
BE CONFIRMED BY EACH DISCIPLINE WHEN REVIEWING THE AV DRAWINGS. THE QUANTITIES GIVEN
ARE PRELIMINARY AND MAY NOT REFLECT ALL LAST MINUTE CHANGES. ANY DISCREPANCIES
SHOULD BE REVIEWED WITH THE OWNER.
GENERAL LIGHTING NOTES FOR VIDEO CONFERENCING APPLICATIONS:
· INDIRECT FLORESCENT LIGHTING FIXTURES, CAPABLE OF PROVIDING EVEN ILLUMINATION WITHOUT
SHADOWS IS SUGGESTED.
· AN EVEN 70 FOOT CANDLES REQUIRED AT 4'-0" ABOVE FINISHED FLOOR.
· LAMP COLOR TEMPERATURE OF 3500 KELVIN RECOMMENDED.
· WINDOWS WITHOUT TREATMENT WHERE APPLICABLE MAY CAUSE ISSUES BY ALLOWING A "MIX" OF
LIGHTING COLOR TEMPERATURE FROM HALLWAY OR OUTSIDE LIGHTING.
GENERAL ACOUSTICAL NOTES:
· ROOM AMBIENT FROM ALL IN-ROOM OR EXTERNAL NOISE SOURCES NOT TO EXCEED 40dB
A-WEIGHTED.
· AN OVERALL DESIGN GOAL FOR AN NC-25 TO NC-30 NOISE CRITERIA RATING IS DESIRABLE.
· ACOUSTICAL PANELS OR "SOUND-SOAK" WALL TREATMENTS SHOULD BE CONSIDERED FOR ONE
WALL SURFACE.
· ACOUSTICAL PROPERTIES OF THE CEILING TILES, CARPET AND CARPET PAD SHOULD BE
CONSIDERED DURING SELECTION.
· TO PREVENT SOUND LEAKAGE INTO THESE ROOMS FROM ADJOINING SPACES, ALL WALLS SHOULD
EXTEND TO THE DECKING ABOVE. ALL PENETRATIONS LEAVING THE SPACE SHOULD BE SEALED AS
REQUIRED. THE SPACE ABOVE THE CEILING TILES MAY ALSO NEED CONSIDERATION AND TREATED
WITH FIBERGLASS BATTING.
· ACOUSTICAL REFLECTIONS OFF ALL GLASS SURFACES SHOULD BE ADDRESSED WITH APPROPRIATE
WINDOW TREATMENTS.
· MAXIMUM REVERBERATION TIME SHOULD NOT EXCEED .6 SECONDS FOR ALL ROOMS.
· 8) RECOMMENDED SOUND TRANSMISSION CLASS FOR WALL CONSTRUCTION METHOD TO BE OF A
STC-45 RATING.
JUNCTION BOX SYMBOL LEGEND SPEAKER SYMBOL LEGEND
WALL CEILING FLOOR
A/V ELECTRICAL NOTES
JUNCTION BOX NUMBER,
CORRESPONDING WITH CONDUIT
RISER AND CABLE PULL SCHEDULE
ALPHABET INDICATING SIZE OF CONDUIT
STUBBED INTO ACCESSIBLE CEILING OR
IN/UNDER FLOOR. SEE A/V ELECTRICAL
NOTES FOR EXACT CONDUIT SIZE.
ZONE1
SPEAKER NUMBER
ZONE NUMBER
1-GANG JUNCTION BOX OR MUD RING
2-GANG JUNCTION BOX OR MUD RING
3-GANG JUNCTION BOX OR MUD RING
4-GANG JUNCTION BOX OR MUD RING
VOICE/DATA PORT @ FLOOR
VOICE/DATA PORT @ WALL
POWER RECEPTACLE @ WALL,
DUPLEX, 120V/20A
POWER RECEPTACLE @ WALL,
QUAD, 120V/20A
POWER RECEPTACLE @ WALL,
SINGLE RECESSED, 120V/20A
POWER RECEPTACLE @ CEILING,
DUPLEX, 120V/20A
POWER RECEPTACLE @ CEILING,
QUAD, 120V/20A
POWER RECEPTACLE @ FLOOR,
DUPLEX, 120V/20A
POWER RECEPTACLE @ FLOOR,
QUAD, 120V/20A.
VOICE/DATA PORT @ CEILING
FB1
PT1
AV FLOOR BOX
AV POKE THRU
PULL AREA AT PROJECTOR LOCATION
1/2" CONDUIT STUBBED INTO ACCESSIBLE
CEILING
3/4" CONDUIT STUBBED INTO ACCESSIBLE
CEILING
1" CONDUIT STUBBED INTO ACCESSIBLE
CEILING
1 1/4" CONDUIT STUBBED INTO ACCESSIBLE
CEILING
1 1/2" CONDUIT STUBBED INTO ACCESSIBLE
CEILING
AV1
x
J1XX
SB1 CONDUIT STUB UP
P1
PULL AREA AT FLAT PANEL DISPLAY LOCATIONF1
CEILING MOUNTED MICROPHONE PROVIDED BY
AVCM1
CEILING MOUNTED SPEAKER, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATIONS1
CEILING MOUNTED CAMERA, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATIONC1
CEILING MOUNTED WIRELESS GATEWAY, REFER
TO DETAIL FOR EXACT MOUNTING SPECIFICATIONW1
SCREEN LOW VOLTAGE INTERFACE WITH,
MOTOR AND INTERFACE MOUNTS ABOVE
FINISHED CEILING.
LVC1
PULL AREA AT PARTITION SENSOR LOCATIONPS1
PULL AREA AT ANTENNA LOCATIONA1
2" CONDUIT STUBBED INTO ACCESSIBLE
CEILING
WALL BOX
CABLE TV AVT1 AV FLOOR TRACK
FC1 AV FLOOR CORE
CATV
JXXX
WB
JXXX
AV4
JXXX
AV3
JXXX
AV2
JXXX
AV1
JXXX
PULL AREA AT OCCUPANCY SENSOR LOCATIONOS1
HARDWIRED AC POWER
S1
CLEAR CABLE PATH AND STRING TO
ACCESSIBLE CEILING
G
A
B
C
D
E
F
AV PLAN
RIVIERA BEACH FIRE RESCUE
RIVIERA BEACH, FL 33404
600W BLUE HERON BLVD,
AV COVER PAGE
A. ANDERSEN
ANALYTIX
A. ANDERSEN
ARCH FULL BLEED D
(36.00 X 24.00 INCHES)
A. ANDERSEN
RIVIERA BEACH FIRE
RESCUE
AV.C01
AV PLAN
0 05/10/2023 REVIEW
1 06/21/2023 REVIEW
06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023
06/21/2023
06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023 06/21/2023
RIVIERA BEACH, FL
33404
600W BLUE HERON
BLVD,
DRAWING INDEX
SHEET TITLE SHEET DESCRIPTION DATE
AV.C01 AV COVER PAGE
AV.KP.01 AUDIO VISUAL KEY PLAN - 2ND FLOOR PLAN
AV.FP.101 AV - EQUIPMENT & ELECTRICAL FLOOR PLAN - OFFICE 1, OFFICE 2, OFFICE 3, OFFICE 4 AV.FP.102 AV - EQUIPMENT & ELECTRICAL FLOOR PLAN - OFFICE 5, OFFICE 6, BREAK ROOM AV.FP.103 AV - EQUIPMENT & ELECTRICAL FLOOR & CEILING PLAN - CONF. ROOM 1, CONF. ROOM 2
AV.FP.104 AV - EQUIPMENT & ELECTRICAL FLOOR PLAN - WORK ROOM, BULLPEN
AV.FP.105 AV - EQUIPMENT & ELECTRICAL CEILING PLAN - BULLPEN
AV.EL.01 AV - EQUIPMENT & ELECTRICAL DISPLAY ELEVATION - OFFICES (1-6), BREAK ROOM, WORK AREA AV.EL.02 AV - EQUIPMENT & ELECTRICAL DISPLAY & W.P. ELEVATION - CONF.RM 1, CONF.RM 2, OFFICES(1-6)
AV.EL.03 AV - EQUIPMENT & ELECTRICAL DISPLAY ELEVATION - BULLPEN
AV.EL.04 AV - EQUIPMENT & ELECTRICAL VIDEO WALL ELEVATION & SIDE ELEVATION - BULLPEN
AV.EL.05 AV - EQUIPMENT & ELECTRICAL CEILING CAMERA & RACK ELEVATION - BULLPEN
AV.F00 CABLE SCHEDULE & AV CABLE LEGEND
AV.F01 AV SYSTEM FLOW DIAGRAM - OFFICES(1-6) & CONFERENCE ROOM 1
AV.F02 AV SYSTEM FLOW DIAGRAM - WORK AREA
AV.F03 AV SYSTEM FLOW DIAGRAM - BULLPEN (01 OF 04)
AV.F04 AV SYSTEM FLOW DIAGRAM - BULLPEN (02 OF 04)
AV.F05 AV SYSTEM FLOW DIAGRAM - BULLPEN (03 OF 04)
AV.F06 AV SYSTEM FLOW DIAGRAM - BULLPEN (04 OF 04)
AV.F07 AV SYSTEM FLOW DIAGRAM - CONFERENCE ROOM 2 & BREAK ROOM
AV.F08 RACK ELEVATION DIAGRAM - STORAGE
AV.D01 AV DETAIL (01 OF 06)
AV.D02 AV DETAIL (02 OF 06)
AV.D03 AV DETAIL (03 OF 06)
AV.D04 AV DETAIL (04 OF 06)
AV.D05 AV DETAIL (05 OF 06)
AV.D06 AV DETAIL (06 OF 06)
4 5
R
EF
FEC
FEC
FE
C
DN
CRCR
CR
CR
CR
FE
CR
CR
CR
DN
CR CR
CR
CR
LOBBY
JANITOR
REST. 11
WELLNESS
IT / AV ROOM
ELEVATOR
APPARATUS
BAY**
1 3 4
A
E
C
D
B
F
'-6
'-1 1/
'-8
/16
OPEN
TO BELOW
'-0
TRUE
N
PHONE BANK
OFFICE 6
BULLPEN
MURPHY BED,
TYPICAL IN
ALL SECOND
FLOOR
OFFICES
CONFERENCE
ROOM 2
BREAKROOM
C O
R R
ID
O
R
TV
12'-3 5/8"
19'-4 3/8"
GENERATOR
6'
CONCRETE
OVERHANG
6' CONCRETE
OVERHANG
TV
TV
TV
TV
TV
BALCONY
OFFICE 3
POD ROOM
CONFERENCE
ROOM 1
TV
OPEN TO BELOW
BALCONY
ADA REST. 10
REST. 12
REST. 13
TV
OFFICE 5
BDA CLOSET
TV
OFFICE 1STORAGE
TV
ELECTRICAL
ROOM
OFFICE 4
5'- 0"
TV
WORK AREA
OFFICE 2
CORRIDOR
TV
TVTV
12" HIGH PLATFORM
LOW
WALL
(2) 6"
RISERS
1 2 3
4'-8" 4'-8"
TV
7'-0" 7'-0"
TV
TV
TV
ADA RAMP 1:12UP
6'-
5/8
OVERHANG
GROUT ALL CMU
CELLS SOLID
ALONG THIS WALL
ADJACENT TO
POD ROOM &
WELLNESS ROOM 6" GAS FLU CHASE.
COORDINATE WITH
MEP TYPICAL.
G
'-8
5/1 6"
'-1
3'-2 3/8"
13'-0"
'-0
6'- 0 5
/8"
6" CHASE
6" CHASE
7" CHASE. COORDINATE
WITH MEP TYPICAL.
10" CHASE.
COORDINATE WITH
MEP TYPICAL.
6 1/2" CHASE WALL.
COORDINATE WITH
MEP TYPICAL.
20'-0" 87'-0" 18'-7"
8" 3'-
4"
5 1 /2"
5'- 2"
6'-7 3/8"
5'-4 1/2"
6'-7 1/16"
11'-9 7/8"
48'-5 1/4" 3'-3" 25'-3"
1'-3 1/4" 75'-8"
13'-0"
99'-11" 1'-3 1/4"
'-4
/16
FRAMED WALL FOR
ELEVATOR CONTROLS.
COORDINATE WITH
ELEVATOR MANUFACTURER
1'- 5"
3'- 3"
'-4
TV
HANDRAIL
42" HIGH
CONTINUOUS KNEE
WALL
1'- 0"
MEZZANINE
10' - 0"
13' - 4"
FOYER
GROUT ALL CMU CELLS
SOLID ALONG THIS WALL
ADJACENT TO OFFICE 3
YELLOW ZONE
ROOF SERVICE
ACCESS DOOR
5'- 0"
3'- 3"
8'- 8"
7'- 8"
'-2
'-1 1/2
11'-7 3/4"
4'-0"
MECHANICAL WELL ROOF
ACCESS
WALL
LADDER
TO
ROOF
HATCH
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
ES
AV
-W
O R
X.
C
O M
AUDIO VISUAL KEY PLAN
- 2ND FLOOR PLAN
A. ANDERSEN
ANALYTIX
A. ANDERSEN
RESCUE
AV.KP.01
SCALE:
1 AUDIO VISUAL KEY PLAN - 2ND FLOOR PLAN
3/32" = 1'-0"
OFFICES 1-6
RIVIERA BEACH, FL
33404
BREAK ROOM
CONFERENCE ROOM 1
OFFICE 1
AV.FP.101
OFFICE 2
AV.FP.101
OFFICE 3
AV.FP.101
OFFICE 4
AV.FP.101
OFFICE 5
AV.FP.102
OFFICE 6
AV.FP.102
BREAK ROOM
AV.FP.102
CONFERENCE ROOM 1
AV.FP.103
CONFERENCE ROOM 2
AV.FP.103
CONFERENCE ROOM 2
WORK AREA
AV.FP.104
WORK AREA
BULLPEN
BULLPEN
AV.FP.104, AV.FP.105
600W BLUE HERON
BLVD,
FB1
PT1
SB1
CATV
JX
AVT1
FC1
VOICE/DATA PORT @ FLOOR
VOICE/DATA PORT @ WALL
POWER RECEPTACLE @ WALL,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ WALL,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ WALL,
SINGLE RECESSED, 120V/20A
VOICE/DATA PORT @ CEILING
POWER RECEPTACLE @ CEILING,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ CEILING,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ FLOOR,
DUPLEX, 120V/20A
POWER RECEPTACLE @ FLOOR,
QUAD, 120V/20A.
A/V ELECTRICAL SYMBOLS
1-GANG JUNCTION BOX OR MUD RING @WALL
2-GANG JUNCTION BOX OR MUD RING @WALL
3-GANG JUNCTION BOX OR MUD RING @WALL
4-GANG JUNCTION BOX OR MUD RING @WALL
PULL AREA AT PROJECTOR LOCATIONP1
PULL AREA AT CEILING FOR TOUCH-ENABLED
SWITCHED GLASS
GS
CEILING MOUNTED MICROPHONE PROVIDED BY
AVC
M1
CEILING MOUNTED SPEAKER, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
S1
CEILING MOUNTED CAMERA, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
C1
CEILING MOUNTED WIRELESS GATEWAY, REFER TO
DETAIL FOR EXACT MOUNTING SPECIFICATION
W1
SCREEN LOW VOLTAGE INTERFACE WITH,
MOTOR AND INTERFACE MOUNTS ABOVE
FINISHED CEILING.
PULL AREA AT CEILING RACK LOCATIONER1
PULL AREA AT CEILING FOR SOUND MASKING EMITTERE1
AV FLOOR BOX @ FLOOR
AV POKE THRU @ FLOOR
CONDUIT STUB UP @ FLOOR
WALL BOX @WALL
CABLE TV @WALL
AV FLOOR TRACK @ FLOOR
AV FLOOR CORE @ FLOOR
PULL AREA AT ANTENNA LOCATIONA1
LVC1
WB
JX
AV4
JX
AV3
JX
AV2
JX
AV1
JX
AUDIO VISUAL ELECTRICAL NOTES
3/4" CONDUIT TO ACCESSIBLE CEILING
1" CONDUIT TO ACCESSIBLE CEILING
1 1/4" CONDUIT TO ACCESSIBLE CEILING
1 1/2" CONDUIT TO ACCESSIBLE CEILING
3" CONDUIT TO ACCESSIBLE CEILING
CLEAR CABLE PATH AND STRING TO ACCESSIBLE
CEILING
1/2" CONDUIT TO ACCESSIBLE CEILINGA
B
C
D
E
F
G
INSTALL NOTES
OFFICE 1
TV1
AV.EL.01
A
AV.EL.02
E
AUDIO VISUAL EQUIPMENT LEGEND
OFFICES 1-6
VIEWSONIC / CDE6520-W / 65" DISPLAY
4 LIBERTY AV / PC-G1790-E-P-C / WALL PLATE
CHIEF / LTM1U / DISPLAY WALL MOUNT
SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNITOFFICE 1
TV
AV2D
J101
X2
AV.EL.01
B
AV.EL.02
F
AV1D
J102
OFFICE 2
TV1
AV.EL.01
A
4 AV.EL.02
E
OFFICE 2
TV X2
AV2D
J101
AV.EL.01
B
AV.EL.02
F
AV1D
J102
OFFICE 3
TV
AV.EL.01
A
AV.EL.02
E
OFFICE 4
TV
AV.EL.01
A
AV.EL.02
E
OFFICE 3
TV
AV2D
J101
X2
AV.EL.01
B
AV.EL.02
F
AV1D
J102
OFFICE 4
TV
AV2D
J101
X2
AV.EL.01
B
AV.EL.02
F
AV1 D
J102
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
ES
AV
-W
O R
X.
C
O M
AV - EQUIPMENT &
ELECTRICAL FLOOR PLAN
- OFFICE 1, OFFICE 2,
OFFICE 3, OFFICE 4
A. ANDERSEN
ANALYTIX
A. ANDERSEN
RESCUE
AV.FP.101
RIVIERA BEACH, FL
33404
600W BLUE HERON
BLVD,
SCALE:
A AV - EQUIPMENT FLOOR PLAN - OFFICE 1
1/4" = 1'-0" SCALE:
B AV - ELECTRICAL FLOOR PLAN - OFFICE 1
1/4" = 1'-0"
SCALE:
C AV - EQUIPMENT FLOOR PLAN - OFFICE 2
1/4" = 1'-0" SCALE:
D AV - ELECTRICAL FLOOR PLAN - OFFICE 2
1/4" = 1'-0"
SCALE:
E AV - EQUIPMENT FLOOR PLAN - OFFICE 3
1/4" = 1'-0" SCALE:
F AV - ELECTRICAL FLOOR PLAN - OFFICE 3
1/4" = 1'-0"
SCALE:
G AV - EQUIPMENT FLOOR PLAN - OFFICE 4
1/4" = 1'-0" SCALE:
H AV - ELECTRICAL FLOOR PLAN - OFFICE 4
1/4" = 1'-0"
SB1
CATV
JX
AVT1
FC1
VOICE/DATA PORT @ FLOOR
VOICE/DATA PORT @ WALL
POWER RECEPTACLE @ WALL,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ WALL,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ WALL,
SINGLE RECESSED, 120V/20A
VOICE/DATA PORT @ CEILING
POWER RECEPTACLE @ CEILING,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ CEILING,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ FLOOR,
DUPLEX, 120V/20A
POWER RECEPTACLE @ FLOOR,
QUAD, 120V/20A.
A/V ELECTRICAL SYMBOLS
1-GANG JUNCTION BOX OR MUD RING @WALL
2-GANG JUNCTION BOX OR MUD RING @WALL
3-GANG JUNCTION BOX OR MUD RING @WALL
4-GANG JUNCTION BOX OR MUD RING @WALL
PULL AREA AT PROJECTOR LOCATIONP1
PULL AREA AT CEILING FOR TOUCH-ENABLED
SWITCHED GLASS
GS
CEILING MOUNTED MICROPHONE PROVIDED BY
AVC
M1
CEILING MOUNTED SPEAKER, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
S1
CEILING MOUNTED CAMERA, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
C1
CEILING MOUNTED WIRELESS GATEWAY, REFER TO
DETAIL FOR EXACT MOUNTING SPECIFICATION
W1
SCREEN LOW VOLTAGE INTERFACE WITH,
MOTOR AND INTERFACE MOUNTS ABOVE
FINISHED CEILING.
PULL AREA AT CEILING RACK LOCATIONER1
PULL AREA AT CEILING FOR SOUND MASKING EMITTERE1
AV FLOOR BOX @ FLOOR
AV POKE THRU @ FLOOR
CONDUIT STUB UP @ FLOOR
WALL BOX @WALL
CABLE TV @WALL
AV FLOOR TRACK @ FLOOR
AV FLOOR CORE @ FLOOR
PULL AREA AT ANTENNA LOCATIONA1
LVC1
WB
JX
AV4
JX
AV3
JX
AV2
JX
AV1
JX
AUDIO VISUAL ELECTRICAL NOTES
3/4" CONDUIT TO ACCESSIBLE CEILING
1" CONDUIT TO ACCESSIBLE CEILING
1 1/4" CONDUIT TO ACCESSIBLE CEILING
1 1/2" CONDUIT TO ACCESSIBLE CEILING
3" CONDUIT TO ACCESSIBLE CEILING
CLEAR CABLE PATH AND STRING TO ACCESSIBLE
CEILING
1/2" CONDUIT TO ACCESSIBLE CEILINGA
B
C
D
E
F
G
INSTALL NOTES
CR
CR
OFFICE 5
TV
TV
AV.EL.01
A
AV.EL.02
E
CR
CR
OFFICE 5
TV
TV
AV2 D
J101
X2
AV.EL.01
B
AV.EL.02
F
AV1D
J102
R
EF
FE
BREAKROOM
TV
6'-7 5'-4 6'-7
1 3
AV.EL.01
C R
EF
FE
BREAKROOM
TV
6'-7 5'-4 6'-7
X2
AV2D
J115
AV.EL.01
D
AUDIO VISUAL EQUIPMENT LEGEND
OFFICES 1-6
VIEWSONIC / CDE6520-W / 65" DISPLAY
4 LIBERTY AV / PC-G1790-E-P-C / WALL PLATE
CHIEF / LTM1U / DISPLAY WALL MOUNT
SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
OFFICE 6
TV
WALL
AV.EL.01
A
AV.EL.02
E
OFFICE 6
TV
AV2 D
J101
X2
AV.EL.01
B
AV.EL.02
F
AV1D
J102
AUDIO VISUAL EQUIPMENT LEGEND
BREAK ROOM
VIEWSONIC / CDE6520-W / 65" DISPLAY
4 TBD / TBD / OFE CATV
CHIEF / LTM1U / DISPLAY WALL MOUNT
SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
5 QSC / NV-21-HU / VIDEO SWITCHER
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
ES
AV
-W
O R
X.
C
O M
AV - EQUIPMENT &
ELECTRICAL FLOOR PLAN
- OFFICE 5, OFFICE 6,
BREAK ROOM
A. ANDERSEN
ANALYTIX
A. ANDERSEN
RESCUE
AV.FP.102
RIVIERA BEACH, FL
33404
600W BLUE HERON
BLVD,
SCALE:
A AV - EQUIPMENT FLOOR PLAN - OFFICE 5
1/4" = 1'-0" SCALE:
B AV - ELECTRICAL FLOOR PLAN - OFFICE 5
1/4" = 1'-0"
SCALE:
E AV - EQUIPMENT FLOOR PLAN - BREAK ROOM
1/4" = 1'-0" SCALE:
F AV - ELECTRICAL FLOOR PLAN - BREAK ROOM
1/4" = 1'-0"
SCALE:
C AV - EQUIPMENT FLOOR PLAN - OFFICE 6
1/4" = 1'-0" SCALE:
D AV - ELECTRICAL FLOOR PLAN - OFFICE 6
SB1
CATV
JX
AVT1
FC1
VOICE/DATA PORT @ FLOOR
VOICE/DATA PORT @ WALL
POWER RECEPTACLE @ WALL,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ WALL,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ WALL,
SINGLE RECESSED, 120V/20A
VOICE/DATA PORT @ CEILING
POWER RECEPTACLE @ CEILING,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ CEILING,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ FLOOR,
DUPLEX, 120V/20A
POWER RECEPTACLE @ FLOOR,
QUAD, 120V/20A.
A/V ELECTRICAL SYMBOLS
1-GANG JUNCTION BOX OR MUD RING @WALL
2-GANG JUNCTION BOX OR MUD RING @WALL
3-GANG JUNCTION BOX OR MUD RING @WALL
4-GANG JUNCTION BOX OR MUD RING @WALL
PULL AREA AT PROJECTOR LOCATIONP1
PULL AREA AT CEILING FOR TOUCH-ENABLED
SWITCHED GLASS
GS
CEILING MOUNTED MICROPHONE PROVIDED BY
AVC
M1
CEILING MOUNTED SPEAKER, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
S1
CEILING MOUNTED CAMERA, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
C1
CEILING MOUNTED WIRELESS GATEWAY, REFER TO
DETAIL FOR EXACT MOUNTING SPECIFICATION
W1
SCREEN LOW VOLTAGE INTERFACE WITH,
MOTOR AND INTERFACE MOUNTS ABOVE
FINISHED CEILING.
PULL AREA AT CEILING RACK LOCATIONER1
PULL AREA AT CEILING FOR SOUND MASKING EMITTERE1
AV FLOOR BOX @ FLOOR
AV POKE THRU @ FLOOR
CONDUIT STUB UP @ FLOOR
WALL BOX @WALL
CABLE TV @WALL
AV FLOOR TRACK @ FLOOR
AV FLOOR CORE @ FLOOR
PULL AREA AT ANTENNA LOCATIONA1
LVC1
WB
JX
AV4
JX
AV3
JX
AV2
JX
AV1
JX
AUDIO VISUAL ELECTRICAL NOTES
3/4" CONDUIT TO ACCESSIBLE CEILING
1" CONDUIT TO ACCESSIBLE CEILING
1 1/4" CONDUIT TO ACCESSIBLE CEILING
1 1/2" CONDUIT TO ACCESSIBLE CEILING
3" CONDUIT TO ACCESSIBLE CEILING
CLEAR CABLE PATH AND STRING TO ACCESSIBLE
CEILING
1/2" CONDUIT TO ACCESSIBLE CEILINGA
B
C
D
E
F
G
INSTALL NOTES
CR
CONFERENCE
ROOM 2
TV
5 1 /2"
AV.EL.02
C
6 9
CR
CONFERENCE
ROOM 2
TV
5 1 /2"
X2
AV2 D
J112
AV.EL.02
D
AV2 D
J114 D
FB5
X2AV1 D
J113
(X2)
AUDIO VISUAL EQUIPMENT LEGEND
CONFERENCE ROOM 2
VIEWSONIC / CDE6520-W / 65" DISPLAY
CHIEF / LTM1U / DISPLAY WALL MOUNT
SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
QSC / AD-C6T-WH / CEILING SPEAKER
LOGITECH / TAP / TOUCH PANEL WITH LOGITECH / SWYTCH
/ VIDEO CONFERENCING DEVICE
SHURE / MXA920W-S / MICROPHONE
QSC / NC-12X80 / CAMERA
QSC / NV-21-HU / VIDEO SWITCHER
RDL / DD-BN22 / WALL PLATE
EXTRON / DTP R HWP 4K 231 D / DTP RECEIVER
EXTRON / DTP T HWP 4K 231 D / DTP TRANSMITTER
10 LOGITECH / ROOMMATE / VIDEO CONFERENCING DEVICE
ACT 2x2 9' - 6"
GB
9' - 0"
CONFERENCE
ROOM 2
2'- 6"
2'-6"
2'-
7/1 6"
4'-6 3/4"
2'-3 5/8" 1'-0"
1'- 3"1'-
7/1
6"
EQ EQ
EQ
EQ
1'-3"
1'-0 5/8"
S25
ZONE 5
TAP @ 15W
TO RACK
S26
ZONE 5
TAP @ 15W
S27
ZONE 5
TAP @ 15W
S30
ZONE 5
TAP @ 15W
S29
ZONE 5
TAP @ 15W
S28
ZONE 5
TAP @ 15W
M1
TO RACK
ACT 2x2 9' - 6"
GB
9' - 0"
CONFERENCE
ROOM 2
2'- 6"
2'-6"
2'-
7/1 6"
4'-6 3/4"
2'-3 5/8" 1'-0"
1'- 3"1'-
7/1
6"
EQ EQ
EQ
EQ
1'-3"
1'-0 5/8"
12 12 12
CR
CONFERENCE
ROOM 1
TV
6" CHASE
8"
AV.EL.02
A
CR
CONFERENCE
ROOM 1
TV
6" CHASE
8"
AV.EL.02
B
AV2 D
J101
X2
D
FB1
X2
(X2)
AUDIO VISUAL EQUIPMENT LEGEND
CONFERENCE ROOM 1
VIEWSONIC / CDE6520-W / 65" DISPLAY
CHIEF / LTM1U / DISPLAY WALL MOUNT
SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
7 QSC / AD-C6T-WH / CEILING SPEAKER
6 QSC / SPA4-60 / POWER AMPLIFIER
3 EXTRON / HDMI 4K 230 / DTP TRANSMITTER
4 EXTRON / HDMI 4K 230 / DTP RECEIVER
ACT 2x2 9' - 6"
GB
9' - 0"
CONFERENCE
ROOM 1 2'-3 5/8"
2'- 8 7
/16
2'- 6"
4'-6 1/8"
EQ
EQ
1'-0"
1'-0"
1'-3"
1'- 3"1'-
7/1
6"
1'-3" 1'-0 5/8"
S1
ZONE 1
TAP @ 30W
TO DISPLAY
S2
ZONE 1
TAP @ 30W
ACT 2x2 9' - 6"
GB
9' - 0"
CONFERENCE
ROOM 1 2'-3 5/8"
2'- 8 7
/16
2'- 6"
4'-6 1/8"
EQ
EQ
1'-0"
1'-0"
1'-3"
1'- 3"1'-
7/1
6"
1'-3" 1'-0 5/8"
7 7
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
ES
AV
-W
O R
X.
C
O M
AV - EQUIPMENT &
ELECTRICAL FLOOR &
CEILING PLAN - CONF.
ROOM 1, CONF. ROOM 2
A. ANDERSEN
ANALYTIX
A. ANDERSEN
RESCUE
AV.FP.103
RIVIERA BEACH, FL
33404
600W BLUE HERON
BLVD,
SCALE:
E AV - EQUIPMENT FLOOR PLAN - CONFERENCE ROOM 2
1/4" = 1'-0" SCALE:
F AV - ELECTRICAL FLOOR PLAN - CONFERENCE ROOM 2
1/4" = 1'-0"
SCALE:
G AV - EQUIPMENT CEILING PLAN - CONFERENCE ROOM 2
1/4" = 1'-0" SCALE:
H AV - ELECTRICAL CEILING PLAN - CONFERENCE ROOM 2
1/4" = 1'-0"
SCALE:
A AV - EQUIPMENT FLOOR PLAN - CONFERENCE ROOM 1
1/4" = 1'-0" SCALE:
B AV - ELECTRICAL FLOOR PLAN - CONFERENCE ROOM 1
1/4" = 1'-0"
SCALE:
C AV - EQUIPMENT CEILING PLAN - CONFERENCE ROOM 1
1/4" = 1'-0" SCALE:
D AV - ELECTRICAL CEILING PLAN - CONFERENCE ROOM 1
SB1
CATV
JX
AVT1
FC1
VOICE/DATA PORT @ FLOOR
VOICE/DATA PORT @ WALL
POWER RECEPTACLE @ WALL,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ WALL,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ WALL,
SINGLE RECESSED, 120V/20A
VOICE/DATA PORT @ CEILING
POWER RECEPTACLE @ CEILING,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ CEILING,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ FLOOR,
DUPLEX, 120V/20A
POWER RECEPTACLE @ FLOOR,
QUAD, 120V/20A.
A/V ELECTRICAL SYMBOLS
1-GANG JUNCTION BOX OR MUD RING @WALL
2-GANG JUNCTION BOX OR MUD RING @WALL
3-GANG JUNCTION BOX OR MUD RING @WALL
4-GANG JUNCTION BOX OR MUD RING @WALL
PULL AREA AT PROJECTOR LOCATIONP1
PULL AREA AT CEILING FOR TOUCH-ENABLED
SWITCHED GLASS
GS
CEILING MOUNTED MICROPHONE PROVIDED BY
AVC
M1
CEILING MOUNTED SPEAKER, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
S1
CEILING MOUNTED CAMERA, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
C1
CEILING MOUNTED WIRELESS GATEWAY, REFER TO
DETAIL FOR EXACT MOUNTING SPECIFICATION
W1
SCREEN LOW VOLTAGE INTERFACE WITH,
MOTOR AND INTERFACE MOUNTS ABOVE
FINISHED CEILING.
PULL AREA AT CEILING RACK LOCATIONER1
PULL AREA AT CEILING FOR SOUND MASKING EMITTERE1
AV FLOOR BOX @ FLOOR
AV POKE THRU @ FLOOR
CONDUIT STUB UP @ FLOOR
WALL BOX @WALL
CABLE TV @WALL
AV FLOOR TRACK @ FLOOR
AV FLOOR CORE @ FLOOR
PULL AREA AT ANTENNA LOCATIONA1
LVC1
WB
JX
AV4
JX
AV3
JX
AV2
JX
AV1
JX
AUDIO VISUAL ELECTRICAL NOTES
3/4" CONDUIT TO ACCESSIBLE CEILING
1" CONDUIT TO ACCESSIBLE CEILING
1 1/4" CONDUIT TO ACCESSIBLE CEILING
1 1/2" CONDUIT TO ACCESSIBLE CEILING
3" CONDUIT TO ACCESSIBLE CEILING
CLEAR CABLE PATH AND STRING TO ACCESSIBLE
CEILING
1/2" CONDUIT TO ACCESSIBLE CEILINGA
B
C
D
E
F
G
INSTALL NOTES
FEC
CR
CR
BULLPEN
CONFERENCE
TV
TV
TV
TV
TV
TV
BDA CLOSET
OFFICE 1STORAGE
TV
TV
OFFICE 2
TV
TVTV
12" HIGH PLATFORM
LOW
WALL
(2) 6"
RISERS
ADA RAMP 1:12UP
6" GAS FLU CHASE.
COORDINATE WITH
MEP TYPICAL.
10" CHASE.
COORDINATE WITH
MEP TYPICAL.
HANDRAIL
13' - 4"
AV.EL.01
A
AV.EL.01
A
AV.EL.03
A
AV.EL.03
A
AV.EL.03
A
AV.EL.03
C
AV.EL.03
C
AV.EL.04
C
10 10
10 10
AV.EL.02
E
4 AV.EL.02
E
AV.EL.04
A
AV.EL.04
C
3 3 3
AV.EL.03
A
AV.EL.03
A
AUDIO VISUAL EQUIPMENT LEGEND
BULLPEN
4 VIEWSONIC / CDE8620-W / 86" DISPLAY
5 CHIEF / XTM1U / DISPLAY WALL MOUNT
8 CHIEF / LTM1U / DISPLAY WALL MOUNT
7 VIEWSONIC / CDE7520-W / 75" DISPLAY
13 QSC / NC-12X80 / CAMERA (WITH PTZ-CMB1 CEILING MOUNT)
11 QSC / TSC-101-G3 / TOUCH PANEL
3 QSC / NV-21-HU / VIDEO SWITCHER
10 EXTRON / DTP T HWP 4K 231 D / DTP TRANSMITTER (IN
FLOOR BOX)
15 SHURE / MXA920W-S / MICROPHONE
9 RDL / DD-BN22 / WALL PLATE (IN FLOOR BOX)
QSC / AD-C6T-WH / CEILING SPEAKER
12 MIDDLE ATLANTIC / SR-46-28 / EQUIPMENT RACK
6 SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
1 BARCO / R9867700B / VIDEO WALL DISPLAY
2 BARCO / R9867601 / VIDEO WALL DISPLAY MOUNT
WORK AREA
7" CHASE. COORDINATE
WITH MEP TYPICAL.
AV.EL.01
E
1'
AUDIO VISUAL EQUIPMENT LEGEND
WORK AREA
VIEWSONIC / CDE6520-W / 65" DISPLAY
4 LIBERTY AV / PC-G1790-E-P-C / WALL PLATE
CHIEF / LTM1U / DISPLAY WALL MOUNT
SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
WORK AREA
7" CHASE. COORDINATE
WITH MEP TYPICAL. AV1D
J103
AV2D
J101
X2
AV.EL.01
F
AV1D
J104
AV2D
J102
X2
FEC
CR
CR
BULLPEN
CONFERENCE
TV
TV
TV
TV
TV
TV
BDA CLOSET
OFFICE 1STORAGE
TV
TV
OFFICE 2
TV
TVTV
12" HIGH PLATFORM
LOW
WALL
(2) 6"
RISERS
ADA RAMP 1:12UP
6" GAS FLU CHASE.
COORDINATE WITH
MEP TYPICAL.
10" CHASE.
COORDINATE WITH
MEP TYPICAL.
HANDRAIL
13' - 4"
AV2D
J101
X2
AV.EL.01
B
X2
AV2D
J101
AV.EL.01
B
AV2D
J106
X2
AV.EL.03
B
AV2D
J105
X2
AV.EL.03
B
AV2D
J104
X2
AV.EL.03
B
X2
AV2 D
J110
AV.EL.03
D
X2
AV2 D
J109
AV.EL.03
D
X2
AV2D
ER01
AV.EL.04
D
D
FB1
X2
D
FB2
X2
D
FB4
X2
D
FB3
X2
18'
8'8' 18'
14' 14'
AV.EL.02
F
AV1D
J102
AV.EL.02
F
AV1D
J102
AV2 D
J101
AV.EL.04
B
AV.EL.04
D
AV2 D
J102
AV2 D
J103
X2
AV
D
J1
AV.EL.03
B
X2
AV
D
J1
AV.EL.03
B
(X2) (X2)
(X2) (X2)
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
ES
AV
-W
O R
X.
C
O M
AV - EQUIPMENT &
ELECTRICAL FLOOR PLAN
- WORK ROOM, BULLPEN
A. ANDERSEN
ANALYTIX
A. ANDERSEN
RESCUE
AV.FP.104
RIVIERA BEACH, FL
33404
600W BLUE HERON
BLVD,
SCALE:
C AV - EQUIPMENT FLOOR PLAN - BULLPEN
1/4" = 1'-0"
SCALE:
A AV - EQUIPMENT FLOOR PLAN - WORK ROOM
1/4" = 1'-0" SCALE:
B AV - ELECTRICAL FLOOR PLAN - WORK AREA
1/4" = 1'-0"
SCALE:
D AV - ELECTRICAL FLOOR PLAN - BULLPEN
SB1
CATV
JX
AVT1
FC1
VOICE/DATA PORT @ FLOOR
VOICE/DATA PORT @ WALL
POWER RECEPTACLE @ WALL,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ WALL,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ WALL,
SINGLE RECESSED, 120V/20A
VOICE/DATA PORT @ CEILING
POWER RECEPTACLE @ CEILING,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ CEILING,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ FLOOR,
DUPLEX, 120V/20A
POWER RECEPTACLE @ FLOOR,
QUAD, 120V/20A.
A/V ELECTRICAL SYMBOLS
1-GANG JUNCTION BOX OR MUD RING @WALL
2-GANG JUNCTION BOX OR MUD RING @WALL
3-GANG JUNCTION BOX OR MUD RING @WALL
4-GANG JUNCTION BOX OR MUD RING @WALL
PULL AREA AT PROJECTOR LOCATIONP1
PULL AREA AT CEILING FOR TOUCH-ENABLED
SWITCHED GLASS
GS
CEILING MOUNTED MICROPHONE PROVIDED BY
AVC
M1
CEILING MOUNTED SPEAKER, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
S1
CEILING MOUNTED CAMERA, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
C1
CEILING MOUNTED WIRELESS GATEWAY, REFER TO
DETAIL FOR EXACT MOUNTING SPECIFICATION
W1
SCREEN LOW VOLTAGE INTERFACE WITH,
MOTOR AND INTERFACE MOUNTS ABOVE
FINISHED CEILING.
PULL AREA AT CEILING RACK LOCATIONER1
PULL AREA AT CEILING FOR SOUND MASKING EMITTERE1
AV FLOOR BOX @ FLOOR
AV POKE THRU @ FLOOR
CONDUIT STUB UP @ FLOOR
WALL BOX @WALL
CABLE TV @WALL
AV FLOOR TRACK @ FLOOR
AV FLOOR CORE @ FLOOR
PULL AREA AT ANTENNA LOCATIONA1
LVC1
WB
JX
AV4
JX
AV3
JX
AV2
JX
AV1
JX
AUDIO VISUAL ELECTRICAL NOTES
3/4" CONDUIT TO ACCESSIBLE CEILING
1" CONDUIT TO ACCESSIBLE CEILING
1 1/4" CONDUIT TO ACCESSIBLE CEILING
1 1/2" CONDUIT TO ACCESSIBLE CEILING
3" CONDUIT TO ACCESSIBLE CEILING
CLEAR CABLE PATH AND STRING TO ACCESSIBLE
CEILING
1/2" CONDUIT TO ACCESSIBLE CEILINGA
B
C
D
E
F
G
INSTALL NOTES
CORRIDOR
STORAGE OFFICE 1 OFFICE 2
ACT 2x2 9' - 0"
ACT 2x2 9' - 0"
ACT 2x2 9' - 0"
BULLPEN
ACT 2x2 14' - 0"
1'-11 5/16" 2'-
0"
2'-0"
10'-0" 10'-0" 10'-0"
7'-
/16
8'-
0" 8'-
0" 8'-
0"
2'- 8 7
/16
1'-
7/1 6"
1'-
7/1 6"
BDA CLOSET
6" CHASE
MRGB
9' - 0"
3'- 9 9
/16
2'- 0"
MRGB
13' - 0"
AV.EL.05
A
AUDIO VISUAL EQUIPMENT LEGEND
BULLPEN
4 VIEWSONIC / CDE8620-W / 86" DISPLAY
5 CHIEF / XTM1U / DISPLAY WALL MOUNT
8 CHIEF / LTM1U / DISPLAY WALL MOUNT
7 VIEWSONIC / CDE7520-W / 75" DISPLAY
13 QSC / NC-12X80 / CAMERA (WITH PTZ-CMB1 CEILING MOUNT)
11 QSC / TSC-101-G3 / TOUCH PANEL
3 QSC / NV-21-HU / VIDEO SWITCHER
10 EXTRON / DTP T HWP 4K 231 D / DTP TRANSMITTER (IN
FLOOR BOX)
15 SHURE / MXA920W-S / MICROPHONE
9 RDL / DD-BN22 / WALL PLATE (IN FLOOR BOX)
QSC / AD-C6T-WH / CEILING SPEAKER
12 MIDDLE ATLANTIC / SR-46-28 / EQUIPMENT RACK
6 SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
1 BARCO / R9867700B / VIDEO WALL DISPLAY
2 BARCO / R9867601 / VIDEO WALL DISPLAY MOUNT
CORRIDOR
STORAGE OFFICE 1 OFFICE 2
ACT 2x2 9' - 0"
ACT 2x2 9' - 0"
ACT 2x2 9' - 0"
BULLPEN
ACT 2x2 14' - 0"
1'-11 5/16"
2'- 0"
2'-0"
10'-0" 10'-0" 10'-0"
7'-
/16
8'-
0" 8'-
0" 8'-
0"
2'- 8 7
/16
1'-
7/1 6"
1'-
7/1 6"
BDA CLOSET
6" CHASE
MRGB
9' - 0"
3'- 9 9
/16
2'- 0"
MRGB
13' - 0"
CAM
TO RACK
M1
TO RACK
S1
ZONE 1
TAP @ 30W
TO RACK
S5
ZONE 2
TAP @ 30W
S9
ZONE 3
TAP @ 15W
S16
ZONE 3
TAP @ 15W
S17
ZONE 4
TAP @ 15W
S24
ZONE 4
TAP @ 15W
S2
ZONE 1
TAP @ 30W
S6
ZONE 2
TAP @ 30W
S10
ZONE 3
TAP @ 15W
S15
ZONE 3
TAP @ 15W
S18
ZONE 4
TAP @ 15W
S23
ZONE 4
TAP @ 15W
S3
ZONE 1
TAP @ 30W
S7
ZONE 2
TAP @ 30W
S11
ZONE 3
TAP @ 15W
S14
ZONE 3
TAP @ 15W
S19
ZONE 4
TAP @ 15W
S22
ZONE 4
TAP @ 15W
S4
ZONE 1
TAP @ 30W
S8
ZONE 2
TAP @ 30W
S12
ZONE 3
TAP @ 15W
S13
ZONE 3
TAP @ 15W
S20
ZONE 4
TAP @ 15W
S21
ZONE 4
TAP @ 15W
AV.EL.05
B
TO RACK
TO RACK
TO RACK
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
ES
AV
-W
O R
X.
C
O M
AV - EQUIPMENT &
ELECTRICAL CEILING
PLAN - BULLPEN
A. ANDERSEN
ANALYTIX
A. ANDERSEN
RESCUE
AV.FP.105
RIVIERA BEACH, FL
33404
600W BLUE HERON
BLVD,
SCALE:
A AV - EQUIPMENT CEILING PLAN - BULLPEN
1/4" = 1'-0" SCALE:
B AV - ELECTRICAL CEILING PLAN - BULLPEN
SB1
CATV
JX
AVT1
FC1
VOICE/DATA PORT @ FLOOR
VOICE/DATA PORT @ WALL
POWER RECEPTACLE @ WALL,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ WALL,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ WALL,
SINGLE RECESSED, 120V/20A
VOICE/DATA PORT @ CEILING
POWER RECEPTACLE @ CEILING,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ CEILING,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ FLOOR,
DUPLEX, 120V/20A
POWER RECEPTACLE @ FLOOR,
QUAD, 120V/20A.
A/V ELECTRICAL SYMBOLS
1-GANG JUNCTION BOX OR MUD RING @WALL
2-GANG JUNCTION BOX OR MUD RING @WALL
3-GANG JUNCTION BOX OR MUD RING @WALL
4-GANG JUNCTION BOX OR MUD RING @WALL
PULL AREA AT PROJECTOR LOCATIONP1
PULL AREA AT CEILING FOR TOUCH-ENABLED
SWITCHED GLASS
GS
CEILING MOUNTED MICROPHONE PROVIDED BY
AVC
M1
CEILING MOUNTED SPEAKER, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
S1
CEILING MOUNTED CAMERA, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
C1
CEILING MOUNTED WIRELESS GATEWAY, REFER TO
DETAIL FOR EXACT MOUNTING SPECIFICATION
W1
SCREEN LOW VOLTAGE INTERFACE WITH,
MOTOR AND INTERFACE MOUNTS ABOVE
FINISHED CEILING.
PULL AREA AT CEILING RACK LOCATIONER1
PULL AREA AT CEILING FOR SOUND MASKING EMITTERE1
AV FLOOR BOX @ FLOOR
AV POKE THRU @ FLOOR
CONDUIT STUB UP @ FLOOR
WALL BOX @WALL
CABLE TV @WALL
AV FLOOR TRACK @ FLOOR
AV FLOOR CORE @ FLOOR
PULL AREA AT ANTENNA LOCATIONA1
LVC1
WB
JX
AV4
JX
AV3
JX
AV2
JX
AV1
JX
INSTALL NOTES
AUDIO VISUAL ELECTRICAL NOTES
3/4" CONDUIT TO ACCESSIBLE CEILING
1" CONDUIT TO ACCESSIBLE CEILING
1 1/4" CONDUIT TO ACCESSIBLE CEILING
1 1/2" CONDUIT TO ACCESSIBLE CEILING
3" CONDUIT TO ACCESSIBLE CEILING
CLEAR CABLE PATH AND STRING TO ACCESSIBLE
CEILING
1/2" CONDUIT TO ACCESSIBLE CEILINGA
B
C
D
E
F
G
AUDIO VISUAL EQUIPMENT LEGEND
BREAK ROOM
VIEWSONIC / CDE6520-W / 65" DISPLAY
4 TBD / TBD / OFE CATV
CHIEF / LTM1U / DISPLAY WALL MOUNT
SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
5 QSC / NV-21-HU / VIDEO SWITCHER
4'
5'-11 8"
5'-43 8"
6'-87 8"
A.F.F.
0'-0" A.F.F.
9'-0"
℄ OF
DISPLAY
1 2
4'-11 8"
6'-25 8"
A.F.F.
0'-0" A.F.F.
9'-0"
℄ OF
DISPLAY
X2AV2
J101
2'-4"
3'-2"
PLYWOOD BLOCKING
3'-2" X 2'-4" X 3/4" SIZE
D
AUDIO VISUAL EQUIPMENT LEGEND
OFFICES 1-6
VIEWSONIC / CDE6520-W / 65" DISPLAY
4 LIBERTY AV / PC-G1790-E-P-C / WALL PLATE
CHIEF / LTM1U / DISPLAY WALL MOUNT
SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
AUDIO VISUAL EQUIPMENT LEGEND
WORK AREA
VIEWSONIC / CDE6520-W / 65" DISPLAY
4 LIBERTY AV / PC-G1790-E-P-C / WALL PLATE
CHIEF / LTM1U / DISPLAY WALL MOUNT
SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
4'
5'-11 8"
5'-4 7 16"
6'-87 8"
A.F.F.
0'-0" A.F.F.
9'-0"
℄ OF
DISPLAY
1 2
4'-11 8"
6'-25 8"
A.F.F.
0'-0" A.F.F.
9'-0"
℄ OF
DISPLAY
X2AV2
J115
PLYWOOD BLOCKING
4'-2" X 2'-4" X 3/4" SIZE
D
4'-2"
2'-4"
1'-6"
4'
5'-11 8"
5'-43 8"
6'-87 8"
A.F.F.
0'-0" A.F.F.
9'-0"
℄ OF
DISPLAY
1 2
1'-6"
℄ OF
DISPLAY
1 2
1'
4'-11 8" 4'-11
8"
1'-6"
6'-25 8"
A.F.F.
0'-0" A.F.F.
9'-0"
℄ OF
DISPLAY
X2AV2
J102
AV1
J104
2'-4"
3'-2"
PLYWOOD BLOCKING
3'-2" X 2'-4"X 3/4" SIZE
D
1'-6"
℄ OF
DISPLAY
X2AV2
J101
AV1
J103
PLYWOOD BLOCKING
3'-2" X 2'-4" X 3/4" SIZE
D
3'-2"
2'-4"
AV - EQUIPMENT &
ELECTRICAL DISPLAY
ELEVATION - OFFICES
(1-6), BREAK ROOM,
WORK AREA
A. ANDERSEN
ANALYTIX
A. ANDERSEN
RESCUE
AV.EL.01
RIVIERA BEACH, FL
33404
600W BLUE HERON
BLVD,
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
ES
AV
-W
O R
X.
C
O M
SCALE:
A AV EQUIPMENT DISPLAY ELEVATION - OFFICES (1-6)
1/2" = 1'-0" SCALE:
B AV ELECTRICAL DISPLAY ELEVATION - OFFICES (1-6)
1/2" = 1'-0"
SCALE:
C AV EQUIPMENT DISPLAY ELEVATION - BREAK ROOM
1/2" = 1'-0" SCALE:
D AV ELECTRICAL DISPLAY ELEVATION - BREAK ROOM
1/2" = 1'-0"
SCALE:
E AV EQUIPMENT DISPLAY ELEVATION - WORK AREA
1/2" = 1'-0" SCALE:
F AV ELECTRICAL DISPLAY ELEVATION - WORK AREA
1/2" = 1'-0"
SB1
CATV
JX
AVT1
FC1
VOICE/DATA PORT @ FLOOR
VOICE/DATA PORT @ WALL
POWER RECEPTACLE @ WALL,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ WALL,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ WALL,
SINGLE RECESSED, 120V/20A
VOICE/DATA PORT @ CEILING
POWER RECEPTACLE @ CEILING,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ CEILING,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ FLOOR,
DUPLEX, 120V/20A
POWER RECEPTACLE @ FLOOR,
QUAD, 120V/20A.
A/V ELECTRICAL SYMBOLS
1-GANG JUNCTION BOX OR MUD RING @WALL
2-GANG JUNCTION BOX OR MUD RING @WALL
3-GANG JUNCTION BOX OR MUD RING @WALL
4-GANG JUNCTION BOX OR MUD RING @WALL
PULL AREA AT PROJECTOR LOCATIONP1
PULL AREA AT CEILING FOR TOUCH-ENABLED
SWITCHED GLASS
GS
CEILING MOUNTED MICROPHONE PROVIDED BY
AVC
M1
CEILING MOUNTED SPEAKER, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
S1
CEILING MOUNTED CAMERA, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
C1
CEILING MOUNTED WIRELESS GATEWAY, REFER TO
DETAIL FOR EXACT MOUNTING SPECIFICATION
W1
SCREEN LOW VOLTAGE INTERFACE WITH,
MOTOR AND INTERFACE MOUNTS ABOVE
FINISHED CEILING.
PULL AREA AT CEILING RACK LOCATIONER1
PULL AREA AT CEILING FOR SOUND MASKING EMITTERE1
AV FLOOR BOX @ FLOOR
AV POKE THRU @ FLOOR
CONDUIT STUB UP @ FLOOR
WALL BOX @WALL
CABLE TV @WALL
AV FLOOR TRACK @ FLOOR
AV FLOOR CORE @ FLOOR
PULL AREA AT ANTENNA LOCATIONA1
LVC1
WB
JX
AV4
JX
AV3
JX
AV2
JX
AV1
JX
INSTALL NOTES
AUDIO VISUAL ELECTRICAL NOTES
3/4" CONDUIT TO ACCESSIBLE CEILING
1" CONDUIT TO ACCESSIBLE CEILING
1 1/4" CONDUIT TO ACCESSIBLE CEILING
1 1/2" CONDUIT TO ACCESSIBLE CEILING
3" CONDUIT TO ACCESSIBLE CEILING
CLEAR CABLE PATH AND STRING TO ACCESSIBLE
CEILING
1/2" CONDUIT TO ACCESSIBLE CEILINGA
B
C
D
E
F
G
AUDIO VISUAL EQUIPMENT LEGEND
CONFERENCE ROOM 2
VIEWSONIC / CDE6520-W / 65" DISPLAY
CHIEF / LTM1U / DISPLAY WALL MOUNT
SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
QSC / AD-C6T-WH / CEILING SPEAKER
LOGITECH / TAP / TOUCH PANEL WITH LOGITECH / SWYTCH
/ VIDEO CONFERENCING DEVICE
SHURE / MXA920W-S / MICROPHONE
QSC / NC-12X80 / CAMERA
QSC / NV-21-HU / VIDEO SWITCHER
RDL / DD-BN22 / WALL PLATE
EXTRON / DTP R HWP 4K 231 D / DTP RECEIVER
EXTRON / DTP T HWP 4K 231 D / DTP TRANSMITTER
10 LOGITECH / ROOMMATE / VIDEO CONFERENCING DEVICE
4'
5'-11 8"
5'-43 8"
6'-87 8"
A.F.F.
0'-0" A.F.F.
9'-0"
℄ OF
DISPLAY
1 2
45 6
AUDIO VISUAL EQUIPMENT LEGEND
CONFERENCE ROOM 1
VIEWSONIC / CDE6520-W / 65" DISPLAY
CHIEF / LTM1U / DISPLAY WALL MOUNT
SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
7 QSC / AD-C6T-WH / CEILING SPEAKER
6 QSC / SPA4-60 / POWER AMPLIFIER
3 EXTRON / HDMI 4K 230 / DTP TRANSMITTER
4 EXTRON / HDMI 4K 230 / DTP RECEIVER
1'-6"
5'-51 2"
4'-43 8"
5'-87 8"
7'-11 4"
4'-2"
A.F.F.
0'-0" A.F.F.
9'-0"
℄ OF
DISPLAY
1"
1 2 e
HDMI OUT
IR
R
S-232
Tx R x Tx
R x
G
4'-01 8"
6'-25 8"
A.F.F.
0'-0" A.F.F.
9'-0"
℄ OF
DISPLAY
X2AV2
J101
D
PLYWOOD BLOCKING
3'-6" X 2'-5" X 3/4" SIZE
3'-6"
2'-5"
1'-6"
6'-67 8"
4'-01 8"
A.F.F.
0'-0" A.F.F.
9'-0"
℄ OF
DISPLAY
X2AV2
J112
D
3'-9"
2'-3"
4'-61
2" AV2
J114
PLYWOOD BLOCKING
3'-9" X 2'-3" X 3/4" SIZE
AV1
J113
2'-10"
A.F.F.
0'-0" A.F.F.
9'-0"
℄ OF
WALL PLATE
2'-10"
A.F.F.
0'-0" A.F.F.
9'-0"
℄ OF
WALL PLATE
AV1
J10X
D
PLEASE, SEE THE ARCHITECTURE FOR THE EXACT J.BOX NUMBER
AV - EQUIPMENT &
ELECTRICAL DISPLAY &
W.P. ELEVATION -
CONF.RM 1, CONF.RM 2,
OFFICES(1-6)
A. ANDERSEN
ANALYTIX
A. ANDERSEN
RESCUE
AV.EL.02
RIVIERA BEACH, FL
33404
600W BLUE HERON
BLVD,
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
ES
AV
-W
O R
X.
C
O M
SCALE:
A AV EQUIPMENT DISPLAY ELEVATION - CONFERENCE ROOM 1
1/2" = 1'-0" SCALE:
B AV ELECTRICAL DISPLAY ELEVATION - CONFERENCE ROOM 1
1/2" = 1'-0"
SCALE:
C AV EQUIPMENT DISPLAY ELEVATION - CONFERENCE ROOM 2
1/2" = 1'-0" SCALE:
D AV ELECTRICAL DISPLAY ELEVATION - CONFERENCE ROOM 2
1/2" = 1'-0"
SCALE:
E AV EQUIPMENT WALL PLATE ELEVATION - OFFICES (1-6)
1/2" = 1'-0" SCALE:
F AV ELECTRICAL WALL PLATE ELEVATION - OFFICES (1-6)
SB1
CATV
JX
AVT1
FC1
VOICE/DATA PORT @ FLOOR
VOICE/DATA PORT @ WALL
POWER RECEPTACLE @ WALL,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ WALL,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ WALL,
SINGLE RECESSED, 120V/20A
VOICE/DATA PORT @ CEILING
POWER RECEPTACLE @ CEILING,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ CEILING,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ FLOOR,
DUPLEX, 120V/20A
POWER RECEPTACLE @ FLOOR,
QUAD, 120V/20A.
A/V ELECTRICAL SYMBOLS
1-GANG JUNCTION BOX OR MUD RING @WALL
2-GANG JUNCTION BOX OR MUD RING @WALL
3-GANG JUNCTION BOX OR MUD RING @WALL
4-GANG JUNCTION BOX OR MUD RING @WALL
PULL AREA AT PROJECTOR LOCATIONP1
PULL AREA AT CEILING FOR TOUCH-ENABLED
SWITCHED GLASS
GS
CEILING MOUNTED MICROPHONE PROVIDED BY
AVC
M1
CEILING MOUNTED SPEAKER, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
S1
CEILING MOUNTED CAMERA, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
C1
CEILING MOUNTED WIRELESS GATEWAY, REFER TO
DETAIL FOR EXACT MOUNTING SPECIFICATION
W1
SCREEN LOW VOLTAGE INTERFACE WITH,
MOTOR AND INTERFACE MOUNTS ABOVE
FINISHED CEILING.
PULL AREA AT CEILING RACK LOCATIONER1
PULL AREA AT CEILING FOR SOUND MASKING EMITTERE1
AV FLOOR BOX @ FLOOR
AV POKE THRU @ FLOOR
CONDUIT STUB UP @ FLOOR
WALL BOX @WALL
CABLE TV @WALL
AV FLOOR TRACK @ FLOOR
AV FLOOR CORE @ FLOOR
PULL AREA AT ANTENNA LOCATIONA1
LVC1
WB
JX
AV4
JX
AV3
JX
AV2
JX
AV1
JX
INSTALL NOTES
AUDIO VISUAL ELECTRICAL NOTES
3/4" CONDUIT TO ACCESSIBLE CEILING
1" CONDUIT TO ACCESSIBLE CEILING
1 1/4" CONDUIT TO ACCESSIBLE CEILING
1 1/2" CONDUIT TO ACCESSIBLE CEILING
3" CONDUIT TO ACCESSIBLE CEILING
CLEAR CABLE PATH AND STRING TO ACCESSIBLE
CEILING
1/2" CONDUIT TO ACCESSIBLE CEILINGA
B
C
D
E
F
G
5'
6'-25 8"
6'-97 8"
8'-75 8"
A.F.F.
0'-0" A.F.F.
13'-0"
℄ OF
DISPLAY
4 5
6 3
AUDIO VISUAL EQUIPMENT LEGEND
BULLPEN
4 VIEWSONIC / CDE8620-W / 86" DISPLAY
5 CHIEF / XTM1U / DISPLAY WALL MOUNT
8 CHIEF / LTM1U / DISPLAY WALL MOUNT
7 VIEWSONIC / CDE7520-W / 75" DISPLAY
13 QSC / NC-12X80 / CAMERA (WITH PTZ-CMB1 CEILING MOUNT)
11 QSC / TSC-101-G3 / TOUCH PANEL
3 QSC / NV-21-HU / VIDEO SWITCHER
10 EXTRON / DTP T HWP 4K 231 D / DTP TRANSMITTER (IN
FLOOR BOX)
15 SHURE / MXA920W-S / MICROPHONE
9 RDL / DD-BN22 / WALL PLATE (IN FLOOR BOX)
QSC / AD-C6T-WH / CEILING SPEAKER
12 MIDDLE ATLANTIC / SR-46-28 / EQUIPMENT RACK
6 SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
1 BARCO / R9867700B / VIDEO WALL DISPLAY
2 BARCO / R9867601 / VIDEO WALL DISPLAY MOUNT
8'-13 8"
D
A.F.F.
0'-0" A.F.F.
13'-0"
℄ OF
DISPLAY
X2AV2
J10X
PLYWOOD BLOCKING
3'10" X 3'-4" X 3/4" SIZE
3'-10"
3'-4"
5'-15 8"
PLEASE, SEE THE ARCHITECTURE FOR THE EXACT J.BOX NUMBER
5'
6'-41 4"
6'-67 8"
8'-17 8"
A.F.F.
0'-0" A.F.F.
13'-0"
℄ OF
DISPLAY
6 3
5'-31 4"
7'-75 8"
D
A.F.F.
0'-0" A.F.F.
13'-0"
℄ OF
DISPLAY
X2AV2
J10X
PLYWOOD BLOCKING
3'-8" X 2'-7" X 3/4" SIZE
3'-8"
2'-7"
PLEASE, SEE THE ARCHITECTURE FOR THE EXACT J.BOX NUMBER
AV - EQUIPMENT &
ELECTRICAL DISPLAY
ELEVATION - BULLPEN
A. ANDERSEN
ANALYTIX
A. ANDERSEN
RESCUE
AV.EL.03
RIVIERA BEACH, FL
33404
600W BLUE HERON
BLVD,
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
ES
AV
-W
O R
X.
C
O M
SCALE:
A AV EQUIPMENT 86" DISPLAY ELEVATION - BULLPEN(TYPICAL OF 5)
1/2" = 1'-0" SCALE:
B AV ELECTRICAL 86" DISPLAY ELEVATION - BULLPEN(TYPICAL OF 5)
1/2" = 1'-0"
SCALE:
C AV EQUIPMENT 75" DISPLAY ELEVATION - BULLPEN(TYPICAL OF 2)
1/2" = 1'-0" SCALE:
D AV ELECTRICAL 75" DISPLAY ELEVATION - BULLPEN(TYPICAL OF 2)
SB1
CATV
JX
AVT1
FC1
VOICE/DATA PORT @ FLOOR
VOICE/DATA PORT @ WALL
POWER RECEPTACLE @ WALL,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ WALL,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ WALL,
SINGLE RECESSED, 120V/20A
VOICE/DATA PORT @ CEILING
POWER RECEPTACLE @ CEILING,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ CEILING,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ FLOOR,
DUPLEX, 120V/20A
POWER RECEPTACLE @ FLOOR,
QUAD, 120V/20A.
A/V ELECTRICAL SYMBOLS
1-GANG JUNCTION BOX OR MUD RING @WALL
2-GANG JUNCTION BOX OR MUD RING @WALL
3-GANG JUNCTION BOX OR MUD RING @WALL
4-GANG JUNCTION BOX OR MUD RING @WALL
PULL AREA AT PROJECTOR LOCATIONP1
PULL AREA AT CEILING FOR TOUCH-ENABLED
SWITCHED GLASS
GS
CEILING MOUNTED MICROPHONE PROVIDED BY
AVC
M1
CEILING MOUNTED SPEAKER, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
S1
CEILING MOUNTED CAMERA, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
C1
CEILING MOUNTED WIRELESS GATEWAY, REFER TO
DETAIL FOR EXACT MOUNTING SPECIFICATION
W1
SCREEN LOW VOLTAGE INTERFACE WITH,
MOTOR AND INTERFACE MOUNTS ABOVE
FINISHED CEILING.
PULL AREA AT CEILING RACK LOCATIONER1
PULL AREA AT CEILING FOR SOUND MASKING EMITTERE1
AV FLOOR BOX @ FLOOR
AV POKE THRU @ FLOOR
CONDUIT STUB UP @ FLOOR
WALL BOX @WALL
CABLE TV @WALL
AV FLOOR TRACK @ FLOOR
AV FLOOR CORE @ FLOOR
PULL AREA AT ANTENNA LOCATIONA1
LVC1
WB
JX
AV4
JX
AV3
JX
AV2
JX
AV1
JX
INSTALL NOTES
AUDIO VISUAL ELECTRICAL NOTES
3/4" CONDUIT TO ACCESSIBLE CEILING
1" CONDUIT TO ACCESSIBLE CEILING
1 1/4" CONDUIT TO ACCESSIBLE CEILING
1 1/2" CONDUIT TO ACCESSIBLE CEILING
3" CONDUIT TO ACCESSIBLE CEILING
CLEAR CABLE PATH AND STRING TO ACCESSIBLE
CEILING
1/2" CONDUIT TO ACCESSIBLE CEILINGA
B
C
D
E
F
G
5'
A.F.F.
0'-0" A.F.F.
13'-0"
℄ OF
VIDEO WALL
2 1 2 1 2 1 2 1 2 1
2 1 2 1 2 1 2 1 2 1
4'-53 4"
3 3
AUDIO VISUAL EQUIPMENT LEGEND
BULLPEN
4 VIEWSONIC / CDE8620-W / 86" DISPLAY
5 CHIEF / XTM1U / DISPLAY WALL MOUNT
8 CHIEF / LTM1U / DISPLAY WALL MOUNT
7 VIEWSONIC / CDE7520-W / 75" DISPLAY
13 QSC / NC-12X80 / CAMERA (WITH PTZ-CMB1 CEILING MOUNT)
11 QSC / TSC-101-G3 / TOUCH PANEL
3 QSC / NV-21-HU / VIDEO SWITCHER
10 EXTRON / DTP T HWP 4K 231 D / DTP TRANSMITTER (IN
FLOOR BOX)
15 SHURE / MXA920W-S / MICROPHONE
9 RDL / DD-BN22 / WALL PLATE (IN FLOOR BOX)
QSC / AD-C6T-WH / CEILING SPEAKER
12 MIDDLE ATLANTIC / SR-46-28 / EQUIPMENT RACK
6 SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
1 BARCO / R9867700B / VIDEO WALL DISPLAY
2 BARCO / R9867601 / VIDEO WALL DISPLAY MOUNT
5'-1"9'-5" 5'
7'-3"
0'-0" A.F.F.
A.F.F.
13'-0"
8'-13 4"
0'-0" A.F.F.
A.F.F.
13'-0"
PLEASE, SEE THE ELEVATION FOR EXACT J.BOX NUMBER.
5'-2"
D
AV2
J10X
4'-81 8"
8'-13 4"
A.F.F.
0'-0" A.F.F.
13'-0"
℄ OF
VIDEO WALL
D
AV2
J101
PLYWOOD BLOCKING
24'-8" X 5'-2" X 3/4" SIZE
24'-8"
5'-2"
D D D D D
3'-113 4"3'-113
4"3'-61 4"3'-113
4" 103 8"3'-111
8"
AV2
J102
AV2
J103
3'-113 4"
2"
AV - EQUIPMENT &
ELECTRICAL VIDEO WALL
ELEVATION & SIDE
ELEVATION - BULLPEN
A. ANDERSEN
ANALYTIX
A. ANDERSEN
RESCUE
AV.EL.04
RIVIERA BEACH, FL
33404
600W BLUE HERON
BLVD,
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
ES
AV
-W
O R
X.
C
O M
SCALE:
A AV EQUIPMENT VIDEO WALL ELEVATION - BULLPEN
1/2" = 1'-0" SCALE:
C AV EQUIPMENT VIDEO WALL SIDE ELEVATION - BULLPEN
1/2" = 1'-0"
SCALE:
B AV ELECTRICAL VIDEO WALL ELEVATION - BULLPEN
1/2" = 1'-0" SCALE:
D AV ELECTRICAL VIDEO WALL SIDE ELEVATION - BULLPEN
SB1
CATV
JX
AVT1
FC1
VOICE/DATA PORT @ FLOOR
VOICE/DATA PORT @ WALL
POWER RECEPTACLE @ WALL,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ WALL,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ WALL,
SINGLE RECESSED, 120V/20A
VOICE/DATA PORT @ CEILING
POWER RECEPTACLE @ CEILING,
DEDICATED DUPLEX, 120V/20A
POWER RECEPTACLE @ CEILING,
DEDICATED QUAD, 120V/20A
POWER RECEPTACLE @ FLOOR,
DUPLEX, 120V/20A
POWER RECEPTACLE @ FLOOR,
QUAD, 120V/20A.
A/V ELECTRICAL SYMBOLS
1-GANG JUNCTION BOX OR MUD RING @WALL
2-GANG JUNCTION BOX OR MUD RING @WALL
3-GANG JUNCTION BOX OR MUD RING @WALL
4-GANG JUNCTION BOX OR MUD RING @WALL
PULL AREA AT PROJECTOR LOCATIONP1
PULL AREA AT CEILING FOR TOUCH-ENABLED
SWITCHED GLASS
GS
CEILING MOUNTED MICROPHONE PROVIDED BY
AVC
M1
CEILING MOUNTED SPEAKER, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
S1
CEILING MOUNTED CAMERA, REFER TO DETAIL
FOR EXACT MOUNTING SPECIFICATION
C1
CEILING MOUNTED WIRELESS GATEWAY, REFER TO
DETAIL FOR EXACT MOUNTING SPECIFICATION
W1
SCREEN LOW VOLTAGE INTERFACE WITH,
MOTOR AND INTERFACE MOUNTS ABOVE
FINISHED CEILING.
PULL AREA AT CEILING RACK LOCATIONER1
PULL AREA AT CEILING FOR SOUND MASKING EMITTERE1
AV FLOOR BOX @ FLOOR
AV POKE THRU @ FLOOR
CONDUIT STUB UP @ FLOOR
WALL BOX @WALL
CABLE TV @WALL
AV FLOOR TRACK @ FLOOR
AV FLOOR CORE @ FLOOR
PULL AREA AT ANTENNA LOCATIONA1
LVC1
WB
JX
AV4
JX
AV3
JX
AV2
JX
AV1
JX
INSTALL NOTES
AUDIO VISUAL ELECTRICAL NOTES
3/4" CONDUIT TO ACCESSIBLE CEILING
1" CONDUIT TO ACCESSIBLE CEILING
1 1/4" CONDUIT TO ACCESSIBLE CEILING
1 1/2" CONDUIT TO ACCESSIBLE CEILING
3" CONDUIT TO ACCESSIBLE CEILING
CLEAR CABLE PATH AND STRING TO ACCESSIBLE
CEILING
1/2" CONDUIT TO ACCESSIBLE CEILINGA
B
C
D
E
F
G
8'-51 4"
A.F.F.
0'-0" A.F.F.
13'-0"
℄ OF
EQUIPMENT RACK
AUDIO VISUAL EQUIPMENT LEGEND
BULLPEN
4 VIEWSONIC / CDE8620-W / 86" DISPLAY
5 CHIEF / XTM1U / DISPLAY WALL MOUNT
8 CHIEF / LTM1U / DISPLAY WALL MOUNT
7 VIEWSONIC / CDE7520-W / 75" DISPLAY
13 QSC / NC-12X80 / CAMERA (WITH PTZ-CMB1 CEILING MOUNT)
11 QSC / TSC-101-G3 / TOUCH PANEL
3 QSC / NV-21-HU / VIDEO SWITCHER
10 EXTRON / DTP T HWP 4K 231 D / DTP TRANSMITTER (IN
FLOOR BOX)
15 SHURE / MXA920W-S / MICROPHONE
9 RDL / DD-BN22 / WALL PLATE (IN FLOOR BOX)
QSC / AD-C6T-WH / CEILING SPEAKER
12 MIDDLE ATLANTIC / SR-46-28 / EQUIPMENT RACK
6 SCHNEIDER ELECTRIC / PH8W / POWER SUPPLY UNIT
1 BARCO / R9867700B / VIDEO WALL DISPLAY
2 BARCO / R9867601 / VIDEO WALL DISPLAY MOUNT
1'-6"
A.F.F.
0'-0" A.F.F.
13'-0"
℄ OF
EQUIPMENT RACK
X2AV4
ER01
E
12'-7"
A.F.F.
0'-0" A.F.F.
13'-0"
℄ OF
CAMERA
A.F.F.
0'-0" A.F.F.
13'-0"
℄ OF
CAMERA
CAM
AV - EQUIPMENT &
ELECTRICAL CEILING
CAMERA & RACK
ELEVATION - BULLPEN
A. ANDERSEN
ANALYTIX
A. ANDERSEN
RESCUE
AV.EL.05
RIVIERA BEACH, FL
33404
600W BLUE HERON
BLVD,
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
ES
AV
-W
O R
X.
C
O M
SCALE:
C AV EQUIPMENT RACK ELEVATION - BULLPEN
1/2" = 1'-0" SCALE:
D AV ELECTRICAL RACK ELEVATION - BULLPEN
1/2" = 1'-0"
SCALE:
A AV EQUIPMENT CEILING CAMERA ELEVATION - BULLPEN
1/2" = 1'-0" SCALE:
B AV ELECTRICAL CEILING CAMERA ELEVATION - BULLPEN
AUDIO
C-VID
CONTROL
TWISTED PAIR
AV CABLES LEGEND
RGBHV
SPEAKER(4/8Ω)
MIC
POWER
HDMI/DP
DVI
USB
DANTE
DM CABLE
SPEAKER(70V)
CRESNET
BNC CABLE
AVB
OPTIC FIBER
R-101
V-101
A-101
S-101
C-101
TP-101
M-101
P-101
HD-101
DVI-101
U-101
DAN-101
DM-101
SC-101
D-101
RF-101
AVB-101
F-101
CABLE SCHEDULE
CODE PARAGRAPH TITLE DESCRIPTION MANF. / PART NO.
R 5SHCOND/26GA/PL/75OHM/BLACK COMPUTER VIDEO WC 9RGB5STRPLN
V PRECISION VIDEO LINES RG-59U WEST PENN 819
HD PRE-MADE HDMI OR DISPLAY PORT CABLE HD DIGITAL SIGNAL PER CABLE
M MICROPHONE AND LINE LEVEL CABLE 22/2 AWG STP WEST PENN 291
A LINE LEVEL CABLE 20/2 AWG STP WEST PENN 292
SC LOUDSPEAKER CABLES 18/2 AWG UTP WEST PENN 224
S LOUDSPEAKER CABLES 14/2 AWG UTP WEST PENN 226
SW LOUDSPEAKER CABLES - SUBWOOFER 10/2 AWG UTP WEST PENN HA210
C RS232, IR 22/2 AWG STP WEST PENN 291
TP CAT6A DATA CABLE CAT6A WEST PENN 4246A
DM CRESTRON DIGITALMEDIA 4 PR 24 AWG STP (SHIELDED) DM-CBL-8G-NP
U PRE-MADE USB CABLE HID PER CABLE
P EQUPMENT SPECIFIC POWER LINE POWER TO DEVICE PER CABLE
D 4COND(2P/SH)/18GA/DR/PL/TEAL&YELLOW CRESNET CRESTRON CRESNET-NP
RF ANTENNA RG-8U WEST PENN 810
F OPTICAL FIBER TBD TBD
CABLE SCHEDULE
CODE PARAGRAPH TITLE DESCRIPTION MANF. / PART NO.
R 5SHCOND/26GA/PL/75OHM/BLACK COMPUTER VIDEO WC 9RGB5STRPLN
V PRECISION VIDEO LINES RG-59U WEST PENN 819
HD PRE-MADE HDMI OR DISPLAY PORT CABLE HD DIGITAL SIGNAL PER CABLE
M MICROPHONE AND LINE LEVEL CABLE 22/2 AWG STP WEST PENN 291
A LINE LEVEL CABLE 20/2 AWG STP WEST PENN 292
SC LOUDSPEAKER CABLES 18/2 AWG UTP WEST PENN 224
S LOUDSPEAKER CABLES 14/2 AWG UTP WEST PENN 226
SW LOUDSPEAKER CABLES - SUBWOOFER 10/2 AWG UTP WEST PENN HA210
C RS232, IR 22/2 AWG STP WEST PENN 291
TP CAT6A DATA CABLE CAT6A WEST PENN 4246A
DM CRESTRON DIGITALMEDIA 4 PR 24 AWG STP (SHIELDED) DM-CBL-8G-NP
U PRE-MADE USB CABLE HID PER CABLE
P EQUPMENT SPECIFIC POWER LINE POWER TO DEVICE PER CABLE
D 4COND(2P/SH)/18GA/DR/PL/TEAL&YELLOW CRESNET CRESTRON CRESNET-NP
RF ANTENNA RG-8U WEST PENN 810
F OPTICAL FIBER TBD TBD
CLIENT
THIS DRAWING IS THE PROPERTY OF
AV-WORX AND MAY NOT BE
REPRODUCED OR DISTRIBUTED
WITHOUT WRITTEN AUTHORIZATION.
PROJECT
ADDRESS
SYSTEMS INTEGRATION
ISSUED FOR:
REVIEW COORDINATION
CONSTRUCTION AS-BUILT
DESCRIPTION
DRAWING NUMBER:
DESCRIPTIONDATEREV.
ORIGINAL
ACCT. MANAGER:
ENGINEER:
DRAFTER:
REVIEWER:
NATIVE SIZE:
PROJECT NUMBER:
PROJECT MANAGER:
O
LD
O
KE
EC
H
O
BE
E R
D
W
ES
T
PA
LM
B
EA
C
H , F
L
E- M
AI
L:
S
AL
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .