RIR_QAP_W05069.pdf
PDF 205 KB Posted
- Attached to
- Locking Cylinder Federal contract opportunity
- Solicitation number
- N6660425Q0379
About this file
This document is a Receipt Inspection Report (RIR) for a TAHE Facility quality provisions document related to a locking cylinder part (OK-276 CDU). The report specifies detailed quality requirements for manufacturing 2 units of part number 8-52T-151, including mandatory documentation such as a Certificate of Compliance, Mercury Free Statement, and Certificate of Analysis. Specific requirements include using Monel K-500, Class A material that is hot finished and age hardened, sourcing materials domestically, and marking the part with "53711/8-52T-151" in a specified location. The document is associated with a Naval Undersea Warfare Center Division, Newport solicitation (N6660425Q0379) for locking cylinders, to be awarded on a Firm Fixed Price basis.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| CDRLs Redacted.pdf | ||
| Drawing 8-52T-151_32386_FN_B.pdf | ||
| VIR_W05069.pdf | ||
| SAM posting.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TAHEF-Form-No. 008 Rev B
10/3/2023
TAHE FACILITY
NUWC, BLDG. 6
NEWPORT, RI 02841
TAHE FACILITY QUALITY PROVISIONS
RECEIPT INSPECTION REPORT
PART NUMBER
8-52T-151
PART NOMENCLATURE
OK-276 CDU / LOCKING CYLINDER
DRAWING NUMBER
8-52T-151_32386_FN_
REV
B
SOURCE:
S/N:
PURCHASE ORDER:
PURCHASE REQUEST:
WORK ORDER:
N/A
STATEMENT OF WORK:
N/A
SALES ORDER:
Future Builds
QTY RECEIVED:
UNIT THE ORDER IS FOR:
OK-276 CDU
ORDER IS FOR INVENTORY:
PURCHASE
New Manufacture
OUTSIDE SERVICE
CHARACTERISTIC MEASURED / VERIFIED DISPOSITION-REMARKS
THE FOLLOWING QUALITY DOCUMENTATION /
INFORMATION / INSTRUCTIONS MUST BE
PROVIDED / ADHERED TO:
QTY: 2
Certificate of Compliance: that items were manufactured in accordance with all applicable instructions and specifications.
Required (A001)
Mercury Free Statement: A signed document from the supplying vendor certifying that mercury and mercury containing compounds were not intentionally added to nor came in contact with hardware or supplies furnished under this work order. ROHS is not an acceptable substitute.
Required
(A002)
Certificate of Analysis of raw material stating that it meets the specifications identified.
Required – Monel K-500, Class A, Hot Finished and Age hardened per QQ-N-286 (A003)
Domestically Sourced Material: all raw material must be sourced domestically or from a qualified country per DFARS Part 225: Foreign Acquisition.
Required
(A004)
Product Identification: identification must appear on external surfaces of items or packages. (Military specifications will be provided upon request).
Required – Mark “53711/8-52T-151” in location shown by Note 5
Process Certification: that items were manufactured in accordance with special processes identified.
Not Required
Special Packaging Requirements: protect parts to prevent damage during handling and transportation.
Required
GFI: DOCUMENTATION PROVIDED
8-52T-
151_32386_FN_B
QQ-N-286G_2000-
12-07
RIR_QAP_W05069 VIR_W05069
VENDOR DO NOT WRITE BELOW. FOR TAHEF QA ONLY.
TOTAL ACCEPTED
TOTAL REJECTED
INSPECTOR
DATE