RFQ-OH-15-00165

Attachment A: Specifications Autoanalyzer and associated equipment

The contractor shall provide an autoanalyzer and associated equipment as specified below:

· Flow injection autoanalyzer and integrated ion chromatograph capable of analyzing fresh, brackish and saltwater samples

· Block sample digester (holding up to at least 40 samples at a time)

· Computer with Windows 7 operating system, monitor and associated software to interface with auto analyzer and accessories

· Heater apparatus required for analysis of certain analytes below

· Detector assembly

· Auto sampler capable of holding up to 360 samples at once

· At least five (5) sample channels

· At least a sixteen (16) channel reagent pump

· Integrated sample-dilution system

· Equipment/Manifolds to enable the analysis of the following:

Analyte:Detection range:
· Alkalinityat least 10 – 200 mg CaCO3/L or better
· Ammoniaat least 0.03 – 3 mg N/L as NH3 or better
· Total hardnessat least 10 – 200 mg CaCO3/L or better
· Total Kjeldahl nitrogenat least 0.25 – 5 mg N/L or better
· Total Kjeldahl phosphorusat least 0.25 – 5 mg P/L or better
· Nitrate + nitriteat least 0.005 – 0.1 mg N/L or better
· Orthophosphateat least 2 – 80 µg P/L as PO42- or better
· Reducing sugarsat least 20 – 200 mg glucose/L or better
· Silicateat least 10 – 80 µg SiO2/L or better
· Ureaat least 0.2 – 20 mg N/L as Urea or better

· Anions:

Anion:Lower Detection Limit:
· Bromideat least 0.020 mg Br-/L or better
· Chlorideat least 0.008 mg Cl-/L or better
· Fluorideat least 0.008 mg F-/L or better
· Nitrateat least 0.008 mg NO3-/L – N/L or better
· Nitriteat least 0.008 mg NO2-/L – N/L or better
· Phosphorusat least 0.015 mg HPO42- – P/L or better
· Sulfateat least 0.015 mg SO42-/L or better

· On-site equipment installation and demonstrated proof of performance

· Training of equipment and software setup and use

· The computer equipment supplied by the contractor shall be able to accept the EPA image for Windows

· The equipment supplied by the contractor shall be UL (Underwriters Labs) listed or a recognized 3rd party listed. If not normally listed, the contractor shall ensure field listing be done at the manufacturer's location and paid for by the manufacturer.

Delivery: FOB Destination, 60 days ARO