STATEMENT OF WORK/SPECIFICATIONS

(FCC)

TRASH COMPACTORS

I. SPECIFICATIONS:

A. INTRODUCTION

The Federal Bureau of Prisons (FBOP), Federal Correctional Institution located at 3901 Klein Blvd in Lompoc CA intends to make a single award to a responsible entity that will provide all necessary equipment, materials, and incidentals to replace and upgrade current Wastequip trash Compactors and Guardian Control System. The contractor is responsible for pre-programming the Control system replacement/upgrade. All manufacturers’ recommendations will be required to be implemented. All equipment must include all of the required equipment and specifications.

B. SCOPE OF WORK

1. TRASH COMPACTORS FOR FOOD SERVICE- QUANTITY OF 2

265XP-30-F-West Self-Contained Precision Series 265XP Model includes a 10HP Tri-volt T.E.F.C. motor, UL/CUL Listed, 6' remote power unit with weather cover, NEMA 4 rated control panel, controls in panel face, precision guided ram, full Gasket sealed Door, A.N.S.I Z.245.2 compliant, WASTEC rated and structural warranty. 208 VAC, 3-phase electrical. Containers will be placed on existing steel channel tracks. Width of wheels are to be 6”. Color is to be Grey.

THE FOLLOWING WILL EACH BE REQUIRED FOR EACH OF THE TWO COMPACTORS:

Compaction – CO245-265IP-265XP-West Hopper / Doghouse - Double door doghouse flared to rear - 45-degree cellar doors. Dock height is 50.5”.

Compaction –CO109-145-245IP-265XP-345IP Hopper / Doghouse - Magnetic door interlock switch – mounted.

Compaction - CO912-West Quick Disconnects - both sides, includes harting connector.

THE FOLLOWING WILL REQUIRE ONLY A QUANTITY OF 0NE PER ITEM:

Compaction - CO166-West Pressure gauge - color coded and numeric - on 15' hose-mounted.

Compactor - CO122 – West Factory Options - Controls on remote pendant in lieu of mounting in panel face on 15' cord

Compaction - CO190-West Power unit on 265IP/265XP. Only one compactor will be in operation at a time and pricing must reflect that only one power unit is required

Compaction - CO SON330-West 8-30 cubic yards - 330A - Includes (1) Flange, (4) clamps & hoses (8' hose for Accu-pak and 20' hose for all other Stationary and Self Contained models).

Compaction - CO SONTHOSE-West "T" Hose into Hopper & Container - for ALL models.

Compaction - CO SONCOVER-West Weather Proof - Installed. Must be ordered with Unit. Cannot be added later - for ALL models.

Compaction - CO SON 1-West Wired into Wastquip Panel - Models 115A & 330A

2. Trash Compactors for North Camp / South Camp /CMS Medium / FCI- QUANTITY OF 6

265XP-30-F-West Self-Contained Precision Series 265XP Model includes a 10HP Tri-volt T.E.F.C. motor, UL/CUL Listed, 6' remote power unit with weather cover, NEMA 4 rated control panel, controls in panel face, precision guided ram, full Gasket sealed Door, A.N.S.I Z.245.2 compliant, WASTEC rated and structural warranty. 208 VAC, 3-phase electrical. Containers will be placed on existing steel channel tracks. Width of wheels are to be 6”. Left side hydraulic disconnect. Color is to be Grey.

THE FOLLOWING WILL EACH BE REQUIRED FOR EACH OF THE SIX COMPACTORS:

Compaction - CO204 -145-245IP-265XP-345IP-West Hopper / Doghouse - Doghouse fully enclosed, single door, frame & locking hasp. Right side door feed.

Compaction - CO109 -145-245IP-265XP-345IP-West Hopper / Doghouse - Magnetic door interlock switch – mounted.

THE FOLLOWING WILL REQUIRE ONLY A QUANTITY OF FOUR PER ITEM:

Compaction - CO166-West Pressure gauge - color coded and numeric - on 15' hose-mounted.

Compaction - CO190-West Power unit on 265IP/265XP. North Camp, South Camp, FCI and CMS Medium will each require (1) power unit for only a total of (4) being required and pricing must reflect that only four power units are required.

Compaction - CO SON330-West 8-30 cubic yards - 330A - Includes (1) Flange, (4) clamps & hoses (8' hose for Accu-pak and 20' hose for all other Stationary and Self Contained models).

Compaction - CO SON THOSE-West "T" Hose into Hopper & Container - for ALL models.

Compaction - CO SON COVER-West Weather Proof - Installed. Must be ordered with Unit. Cannot be added later - for ALL models.

THE FOLLOWING ONLY REQUIRES A QUANTITY OF ONE:

Compaction - CO SON 1-West Wired into Wastquip Panel - Models 115A & 330A.

3. ADDITIONAL ITEMS FOR EACH OF THE TRASH COMPACTORS- QUANTITY OF EIGHT EACH:

Compaction - VAF-SC-1-West Guardian Control System.

Compaction - VAF-SC-2-West

(AMS) Automatic Maintenance Scheduler.

Compaction - VAF-SC-3-West 100% Full Light.

Compaction - VAF-SC-4-West Multicycle Timer – factory set for 2 cycles.

Compaction - VAF-SC-5-West Low temperature oil.

Compaction - VAF-SC-6-West Structural, Parts and Labor warranty required.

Shipping Fees All equipment must be delivered to Lompoc FCC. Transportation cost are required.

C. QUALITY ASSURANCE

Services and materials provided by the contractor will adhere to and shall be consistent with the most current industry standards, the Underwriters Laboratories (UL) and the General and the National Electric Code (NEC).