Replace POL Ground Storage Tanks - Catwalk Drawing.pdf
PDF 5 MB Posted
- Attached to
- Replace Ground Fuel Tanks Federal contract opportunity
- Solicitation number
- W50S8V-22-B-0004
- Issued by
- Department of the Army National Guard
About this file
This document includes a drawing file and related federal contract opportunity. The drawing file depicts catwalk designs for replacing ground storage tanks, showing railings, stairs, and platforms.
The related federal contract opportunity is a solicitation to replace ground fuel tanks. It is set aside as a total small business opportunity under NAICS code 237120 with a size standard of $39.5 million. The disclosure estimates the contract value between $500,000 and $1 million. Davis Bacon wage rates apply. The bid opening was changed to May 12, 2022 by amendment 0001, which bidders must acknowledge. The soliciting agency is the Department of the Army National Guard. Award will be made based solely on price to the responsible bidder providing a conforming bid most advantageous to the government.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W50S8V22B0004 OF 1419A.pdf | ||
| W50S8V22B0004 OF 1419.pdf | ||
| W50S8V22B0004-0002.pdf | ||
| QA - Replace POL Ground Storage Tanks.pdf | ||
| W50S8V22B0004 Site Visit Attendance Sheet.pdf | ||
| Site Visit PP - Replace POL Ground Storage Tanks.pptx | PPTX presentation | |
| W50S8V-22-B-0004-0001 Amendment Document.pdf | ||
| Statement of Work (SOW) Replace POL Ground Storage Tanks dated 5 April 2022.pdf | ||
| 167 Background Check Form - Replace Ground Fuel Tanks.doc | DOC document | |
| W50S8V-22-B-0004-0001 Conformed Document.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1256380591N Stamp
1256380591N Callout install railing and toe kick along perimeter of each tank.
1256380591N Callout Install new stairs approx 36" wide
1256380591N Callout Platforms (2ea) shall have open mesh tread to prevent winter precipitation build up. Install handrail and toe kick on both ends
1388435220N Line
1388435220N Rectangle
1388435220N Rectangle
1388435220N Polygonal Line
1388435220N Line
1388435220N Polygonal Line
1388435220N Polygonal Line
1388435220N Polygonal Line
1388435220N Polygonal Line
1388435220N Polygonal Line
1388435220N Polygonal Line
1388435220N Polygonal Line
1388435220N Line
1388435220N Polygonal Line
1388435220N Polygonal Line
File details come from the government source that posted it. Updated .