This sources sought notice from the Department of the Navy Naval Sea Systems Command seeks capability statements from suppliers for USC components to be used on a telemetry system. The Naval Warfare Center Corona Division intends to sole source USC components to Universal Switch Corporation as the original equipment manufacturer. Interested parties are requested to respond with capability statements including company information, business size, estimated unit pricing and lead times for the components, as well as any industry commentary on the attached statement of work, by 10:00 AM PDT on November 7th, 2022 via email to the specified contracting officer. The information will help determine the appropriate acquisition approach and availability of qualified suppliers that meet the technical requirements.

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 | 7

PURCHASE DESCRIPTION

Universal Switch Corp (USC)

1. INTRODUCTION

The Naval Surface Warfare Center (NSWC), Corona Division, Performance Assessment Department, requires USC components/equipment listed in section 3 to be used on the TELEMETRY SYSTEM - CLASSIFIED/UNCLASSIFIED (ATS-C/U). This equipment is an integral component of our shipboard portable and range ATS-C/U.

2. BACKGROUND

The NSWC Telemetry Systems Branch facility at Corona has a requirement to provide multiple telemetry systems. In order to meet this requirement, Naval Surface Warfare Center (NSWC), Corona Division, Performance Assessment Department, Code requires the USC equipment as listed in the Requirements. The specifications listed are a hard requirement in order to successfully execute the missions on the schedule for this project at the level of excellence expected of us by our customers.

3. REQUIREMENTS

CLIN P/N DESCRIPTION

MCU1-D8NRAR-

13187

System-Multicoupler-Wideband:

1RU rack mounted unit with dual 1x8 multicoupler with 200- 5200 MHz frequency range, unity gain, N-type-f input connectors (rear facing) and SMA-f output connectors (rear facing), +0dB to +6dB manually adjustable input gain (each input port), front panel power switch, in a 1RU 19" rackmount unit supporting international AC power input (90-264VAC, 47-63Hz).

>Preliminary Specifications Configuration: 2x8 (dual 1:8) System Type: Multicoupler Elements: Solid-state Signal Path: AC coupled analog Frequency Range: 200-5200 MHz Gain: Manually adjustable +0 to + 6dB (min) for each input port Flatness: +/- 2.5 dB Output isolation: >50dB (typ) VSWR (input): <2.0 : 1 (goal) VSWR (output): <2.0 : 1 (goal) Noise figure: <10dB @ max gain -1dB compression point (input): -6dBm (min) Input impedance: 50 ohms Output impedance: 50 ohms Signal connectors: N-type (input) SMA (output) female

2 | 7

MCU1-Q4NRAR-

13191

Signal connector location: Rear panel AC power requirements: 90-264VAC, 47-63Hz, <100 watts AC power switch: front panel Operating temperature: 0 to +55C System Height: 1RU Unit depth: 7" Mounting: Standard 19" rack mount panel size Flex rack mounting: rear, front, or extended Estimated Weight: 12 lbs Gain control: Individual manual adjust at front panel

System-Multicoupler-Wideband: 1RU rack mounted unit with quad 1x4 multicoupler with 200-5200 MHz frequency range, unity gain, N-type-f input connectors (rear facing) and SMA-f output connectors (rear facing), +0dB to +6dB manually adjustable input gain (each input port), front panel power switch, in a 1RU 19" rackmount unit supporting international AC power input (90-264VAC, 47-63Hz).

>Preliminary Specifications Configuration: 4x4 (quad 1:4) System Type: Multicoupler Elements: Solid-state Signal Path: AC coupled analog Frequency Range: 200-5200 MHz Gain: Manually adjustable +0 to + 6dB (min) for each input port Flatness: +/- 2.5 dB Output isolation: >50dB (typ) VSWR (input): <2.0 : 1 (goal) VSWR (output): <2.0 : 1 (goal) Noise figure: <10dB @ max gain -1dB compression point (input): -6dBm (min) Input impedance: 50 ohms Output impedance: 50 ohms Signal connectors: N-type (input) SMA (output) female Signal connector location: Rear panel AC power requirements: 90-264VAC, 47-63Hz, <100 watts AC power switch: front panel Operating temperature: 0 to +55C System Height: 1RU Unit depth: 7" Mounting: Standard 19" rack mount panel size Flex rack mounting: rear, front, or extended Estimated Weight: 12 lbs Gain control: Individual manual adjust at front panel

3 | 7

AP32BI-S5-10

AP32BO-S5-10

Input signal adapter panel (Passive), 32 BNC connectors and expansion port, two 10-foot interconnect cables, two multi-pin termination plugs, and 50 ohm input impedance (512x512 maximum use)

Output signal adapter panel (Active), 32 BNC connectors and expansion port, two 10-foot interconnect cables, two multipin termination plugs, and 50 Ohm output impedance (512x512 maximum use), 90-64VAC power input, non-redundant supply section

4 | 7

S5120FX-36-2

AP256-32BI-700

AP256-32BO-700

CA134-002

CA124-006

MAC4-512X-2

System-Switch-Digital-Differential "422" Digital (35Mbps): 192-inout 384-output non-blocking full-fanout tri-stage digital switching array with 100 Ohm 100 position SCSI signal connectors, dual hot-swap CPUs (provides dual 10/100/1G Ethernet control ports, dual multi-serial [232/422/485] control ports), dual hot-swappable power supplies, hinged front panel with 10-inch advanced control touchscreen display, dual international AC inputs (90-264VAC, 47-63Hz) in a 5RU rack mount enclosure, expandable to 512x512

Panel-Input-Adaptive-Signal-Active: Digital (TTL to 422): 32 input channels with individual LED status indicators, BNC input connectors, TTL receivers, 75 ohm input impedance, dual 90-264VAC power inputs, dual 6-foot AC power cords, redundant power supply sections with monitoring plus audiable/visual alert, 10/100/1G Ethernet health monitoring with SNMP (v1/v2C/v3), SNTP, hard contact alarm port, compatible with S2560F(X) with 50 position SCSI, or S5120F(X) [with separate "Y" adapters] digital switching systems.

Has two 50 position SCSI connectors with 16 pairs per connector. For use in configurations up to 256x256 (S2560x), or 512x512 (S5120x) with "Y" adapters.

Cables not included.

Panel-Output-Adaptive-Signal-Active: Digital (422 to TTL): 32 output channels with individual LED status indicators, BNC output connectors with low-Z TTL outputs, dual 90-264VAC power inputs, dual 6-foot AC power cords, redundant power supply sections with monitoring plus audiable/visual alert, 10/100/1G Ethernet health monitoring with SNMP (v1/v2C/v3), SNTP, hard contact alarm port, compatible with S2560F(X) with 50 position SCSI, or S5120F(X) [with separate "Y" adapters] digital switching systems. Has two 50 position SCSI connectors with 16 pairs per connector. For use in configurations up to 256x256 (S2560x), or 512x512 (S5120x) with "Y" adapters.

Cables not included.

Assembly-Connector: 100-pin SCSI2 to Dual 50-pin SCSI2 Y-adapter including a 2-foot 100-pin SCSI2 cable.

CABLE ASSY: SCSI II TO SCSI II 10 FEET

MALE/MALE

Master Array Control Unit - 4RU rack mount mainframe with integrated remote control CPU, redundant and monitored power supplies, and a front panel 10.1" touchscreen LCD control.

5 | 7

RWP 5.0

This unit is programmed for control of a system comprised of S512x series tri-stage switching units

User License (Version 5.0).

NOTE: If software activation (which requires email or telephone access) is not preferred, a USB key version which does not require any activation is available.

6 | 7

LS16A-13196

LS16A-0000020

LS16-D09

LS16-A30

Handling

Shipping

System-Distribution Amplifier-Solid State-Analog (DC- 40MHz) and Digital (TTL) (DC-50Mbps): Distribution system with Four 1:6 analog video distribution sections and Twenty-Four 1:2 digital distribution sections with front panel monitoring port per card, LED status, jumper selectable BNC input impedance (analog module is 75 Ohm), with redundant hot-swappable power supplies.

This system is comprised of the following elements in their listed quantities:

Mainframe-LS Series: 16 slot, 3RU mainframe for use with LS16 series application modules. This unit includes dual redundant hot-swappable power supplies.

Module-Distribution Amplifier-Solid State-Digital: Dual 1x2 digital distribution amplifier for synchronous TTL level unbalanced digital signals with configurable input impedance, BNC outputs, front panel status LED's, and front panel test point for use in an LS16 mainframe

Module-Distribution Amplifier-Solid State-Analog (DC- 40MHz): 1x6 analog video distribution amplifier with BNC connectors, field configurable input impedance (50/75 Ohm), front panel test port, all digital control (local and remote) for adjusting individual output DC Offsets, signal gain adjustment, over voltage detection with set-point adjustment, and signal presence detection for use in an LS16 mainframe.

Handling costs for all items on this quotation to the

NTE shipping costs for all items

7 | 7

ADDITIONAL INFORMATION

A. PERIOD OF PERFORMANCE / REQUIRED DELIVERY DATES

B. PLACE OF PERFORMANCE

C. SHIPPING ADDRESS

D. INSPECTION AND ACCEPTANCE

E. TECHNICAL POINT OF CONTACT

RDD: 4 months ARO

TBD

DODAAC: N64267

NSWC Corona Division 1999 4th Street, Bldg. 503 Norco, CA 92860

Inspection will be conducted by PA personnel

TBD

File details come from the government source that posted it. Updated .