1.0 General
The Bureau of Land Management (BLM), National Interagency Fire Center (NIFC), is has a requirement to replace the existing fence mounted fiber optic Perimeter Intrusion Detection System (PIDs). The system in place is an Optellios branded FiberPatrol FP1000 system which was installed and commissioned in 2006 with portions refreshed in 2013 (server hardware, client hardware, software) the FiberPatrol system controller and fiber are original install. The PIDs currently protects our perimeter of approximately 6300 feet with approximately 6693 feet of deployed fiber optic cable (including maintenance loops). The updated system will be extended approximately 300 feet due to changes in our perimeter fencing. Cable length distances to be confirmed by contractor. A full system replacement of all components to include the fiber optic cable is needed. Newly installed PIDs system will meet or exceed the performance and specifications of the currently installed system.
2.0 Scope
The existing system consists of the FiberPatrol fence mounted perimeter intrusion detection system and FPRAMS Security Management System located in the NIFC data center, and a remote client running FPRAMS software located at the NIFC guard station. The current operating system is Windows 7 Professional. This update shall be a complete replacement of the fiber optic cable, hardware, operating system, and application to include the FiberPatrol system controller, server hardware/software, and client hardware/software. The updated system shall be compatible with NIFC’s current Microsoft OS, Windows 10 Enterprise. The current system allows for field configurable schedules to disable alarm sectors to minimize nuisance alarms due to gate use during duty hours. This functionality will be required of the new system. Upon installation of the new PIDs system a full calibration and inspection to certify the system shall be completed. The end result being a fully updated PIDs that maintains or improves the functionality of the current system. The newly installed system, hardware and software, and overall system functionality shall be covered by parts and labor warranty for a minimum of 2 years.
It is expected the work shall include:
Delivery and installation of controller, server, and client hardware to include associated connectors/cards/any and all components to affect a full replacement of existing system. Delivery, installation and configuration of updated software/firmware/any and all components to provide a fully operation system. The contractor shall be responsible for removal and disposal of all replaced materials and cleanup of the site.
Integration of all components to ensure fully operational system. This includes Closed Circuit Television (CCTV) integration of Pan Tilt Zoom (PTZ) cameras presets to activate upon alarm where CCTV coverage is available and initial input of schedules to disable selected alarm sectors of frequent gate use to minimize nuisance alarms during selected hours. Installer shall coordinate with NIFC Security Manager for specific zones and times for initial input of this scheduling.
New system shall meet the following minimum requirements:
Detect and locate intruders attempting to breach the perimeter fence by cutting, climbing, or lifting the fence fabric.
Be a cut-immune deployment configuration that enables the system’s detection and locating capabilities to remain fully operational in the event of a sensor cable cut.
Sensor unit equipment:
The system shall not require any active devices or processor modules to be installed outdoors.
All active components shall be rack-mountable in an indoor, equipment room environment The indoor system components shall be designed for a standard 19-inch wide rack.
The system shall provide a slide-out monitor and keyboard that enables local console access to the system.
Reliability and Maintenance Requirements Sensor unit:
The sensor unit modules shall have a predicted mean time between failures (MTBF) of greater than 87,000 hours.
System mass storage will be implemented with a minimum of two field-replaceable solid-state drives in a RAID1 configuration that are installed inside the sensor unit.
The sensor unit shall incorporate two redundant field-replaceable power supplies.
The sensor unit shall be capable of performing internal self-diagnostic tests of the internal circuitry, cable continuity, and detection processing.
The sensor unit software shall be field-upgradeable.
Electrical Requirements Each sensor unit shall meet the following electrical requirements:
Input power: 100 to 240 VAC, 50/60 Hz Power consumption: Less than 200W Backup power: The sensor unit shall be capable of being powered from a third-party Uninterruptable Power Supply (UPS) or standby generator.
The system shall not require any outdoor power or grounding connections.
Detection Capabilities The sensor shall consist of fiber optic cable that is attached to the fence along the full length to be protected.
The system shall provide two independent sensing channels.
The system shall be able to detect and locate intrusions over the entire NIFC perimeter deployed cable distance of approximately 7000 feet when the two sensing channels are used independently.
The system shall be able to detect and locate intrusions over the entire NIFC perimeter deployed cable distance of approximately 7000 feet when the system is deployed in the cut-immune configuration.
The sensor unit shall have the following detection capabilities:
Process the signal from the sensor cable to detect intruders attempting to breach the perimeter fence by cutting, climbing, or lifting the fence fabric Locate the position of a detected intrusion within 4.0 m (13 feet) or less with a minimum accuracy of 95%.
Detect multiple simultaneous intrusions, when each intrusion attempt is separated by a sensor cable distance greater than 45 m (150 feet).
Support up to 1440 virtual detection zones.
Be capable of being calibrated to function on different types of metal fencing.
Utilize adaptive algorithms in the detection process to optimally discriminate between actual intrusions and environmental activity.
Intrusion detection performance:
The probability of detection (Pd) of an intruder cutting the fence, lifting the fence fabric, or climbing unaided over the fence shall be 95% with a 95% confidence factor, when the system is installed in accordance with the manufacturer’s directions on a high-quality fence.
False alarm rate: The maximum rate for alarms generated by the internal electronic processes of the processors (cables excluded) shall be less than one per zone per year, averaged over the total number of zones in the system.
Nuisance (environmental) alarms:
The system when calibrated according to manufacturer’s guidelines shall not suffer nuisance alarms from any of the following sources:
Temperature changes Motion of nearby objects or vegetation that are not striking the fence Motion of surface or ground water Sunrise/sunset Acoustic or magnetic effects Snow Fog Seismic vibration caused by nearby vehicular traffic The system shall utilize advanced processing and ambient compensation to minimize the probability of nuisance alarms from the following sources:
Wind Rain and hail Sandstorms Time to detection:
The system shall be capable of generating an alarm within one second from the onset of an attempted breach that involves aggressive contact with the fence, such as attempting to climb or cut the fence.
Fence compatibility:
The system shall support installation on the following types of metal fencing:
Chain-link It shall be possible to use multiple passes of sensor cable to obtain the specified detection performance for fences of any height.
The manufacturer shall provide installation guidelines regarding the type and height of fences that can be protected with one, two, and multiple passes of sensor cable.
Gate compatibility: The sensor cable shall be capable of being installed on lift gates.
Cable cut response The system shall support a closed-loop cut-immune configuration that enables the system’s detection and locating capabilities to remain fully operational in the event of a sensor cable cut.
The system shall be capable of detecting and locating a sensor cable cut.
The cut location shall be determined and reported with an absolute accuracy of equal to or less than 30 m (100 feet).
In the event of a sensor cable cut, the system shall retain detection and locating capabilities in the portion(s) of the sensor cable that remain connected to the system sensor unit.
Installation and Configuration Capabilities The system shall have the following characteristics, as a minimum:
The sensor cable shall be capable of being attached directly to the fence without needing to be put in a conduit. The deployed cable shall include maintenance loops according to industry standard for use in the event of future cable damage.
The sensor cable shall be attached to the fence with standard stainless steel cable ties.
The system shall support the use of non-sensing, “lead in” cable as long as the total length of cable does not exceed 5 km (3.1 miles) per sensor channel.
The system shall support the following configuration and calibration features:
A Windows-based graphical user interface (GUI). GUI shall not time out during periods of non-use and will remain viewable 24 hours per day and 7 days per week.
Configuration and calibration settings shall be capable of being stored in a computer file for record keeping purposes and available for reuse when configuring additional or replacement processors.
Networking Capabilities Network manager tools: The system’s network management software shall provide the following tools to facilitate system commissioning and trouble-shooting:
System status tool that provides a visual display of the status of all processors in the system System event log tool that provides a searchable log of system events.
The system shall support two Ethernet RJ-45 connectors.
Network management:
The system shall include network management software to manage the communications over the sensor network. The network management software shall be capable of running on a standard Windows PC as well as on the sensor unit itself and be accessible via Windows Remote Desktop.
The system’s network management software shall provide a TCP/IP-based interface for communicating alarm and status data to and from security management systems. The system supplier shall furnish complete documentation of this interface to facilitate integration with security management systems.
Event Management The system shall provide a local PC-based operator interface with graphical alarm annunciation at the sensor unit.
The system shall provide access to the following information and functionality when in a local or networked configuration:
A user-configurable image depicting the protected site with a perimeter overlay of the site.
Hardware monitoring and control Event detection and alarm generation (including flashing notification message, location marker, and audible alert) depicted on site map of perimeter Basic alarm management Event and alarm logging Detection zone definition and configuration Adjustment of detection parameters The system shall support the following alarm management functions:
Maintain complete information on all alarms until the alarm is cleared. All alarm data to be archived.
Alarms shall be cleared by local or remote operator. If an alarm is not cleared within 24 hours after alarm generation the system shall clear and archive the alarm as not acknowledged.
Archived alarm information shall be compiled in a scrollable multi- column table.
The maintained information shall include:
Unique alarm ID number Time label Event duration Event status Event strength Event location Disabled alarm records
The operator shall be able to:
Select any of the alarms from the list.
Enter text notes regarding the cause of the alarm and the mitigation measures.
Clear the alarm.
Operator notes as well as the alarm clearing event shall be recorded in the event log.
Alarm location:
The system shall report the down-cable distance of the alarm location It shall be possible to report the alarm location in either meters or feet The system shall report the zone number in which an alarm occurs It shall be possible to configure the system to report the latitude and longitude (GPS coordinate) of the alarm location Event logging:
The system shall maintain and display an event log, including alarms, system notifications, and user actions.
The logs shall be saved to the hard drive upon each alarm event.
A new set of log files shall be generated every 24 hours at midnight Access Control The system shall require the entry of a valid password at start-up.
The system shall divide user access into three security levels:
Operator level for routine operation Supervisor level for advanced system monitoring, configuration, and troubleshooting Installer level for advanced configuration and troubleshooting Inspection and validation of fiber cable.
| Full operation and assurance testing to verify/validate/certify proper system operation. |
| Updated system overview for system administrators. |
| End user training to familiarize with changes in look/feel/operation of the new system. |
3.0 Qualifications
Vendors and technicians shall be factory trained and certified integrators or partners or direct representatives of proposed alarm system manufacturer.
Factory trained and certified technician shall be available within a 30 miles radius of the National Interagency Fire Center for warranty and service as needed.
4.0 Work Location, Schedule and Period of Performance
All work shall be performed at NIFC, 3833 South Development Avenue, Boise Idaho 83705. The anticipated Period of Performance shall be December 14, 2020 through February 12, 2021, however, if the existing system shall be decommissioned during the installation period the contractor shall expediate the installation to minimize system down time. Work shall be performed Monday through Friday, 8:00 AM MST to 5:00 PM MST. Arrangements are possible if work outside normal hours is required.
Contract workers will be required to present official government issued photo identification to gain access to the NIFC. Examples of acceptable identification include valid state issued driver’s license, federal government issued passport, etc.
The contractor shall supply all tools required to complete the installation and any required testing. The government shall not be responsible for the security of the contractor’s tools.
All work shall be performed following Federal, State and local OSHA safety regulations.