Attachment 1 P17PS01856
1 CRLA Building 1 (Sager) Zone Location Manufacturer Device Type Installed/Replaced
Zone 1: 1st Floor Bldg 1: First Floor FACP Fire-Lite Sensiscan Additional Panel batteries
1-1 Rear Exit Fire-Lite BG-10 Pull Station 1-2 Hall by Rear Exit (113) Fire-Lite CPD 7021 Ionization 1-3 Hall by Break Room (113) Fire-Lite CPD 7051 Ionization August, 2003 1-4 Hall by Bottom of West Stairs (113) Fire-Lite CPD 7021 Photoelectric 1-5 Hall 111 Fire-Lite CPD 7021 Ionization 1-6 Front Entry West Wall (101) Fire-Lite CPD 7051 Ionization August, 2003 1-7 Front Entry (101) Fire-Lite BG-10 Pull Station 1-8 Office 109 West Fire-Lite CPD 7021 Ionization 1-9 Office 109 East Fire-Lite CPD 7051 Ionization August, 2003
1-10 Front Entry East Wall (101) Fire-Lite CPD 7051 Ionization August, 2003 1-11 Hall 105 West Fire-Lite CPD 7051 Ionization August, 2003 1-12 Hall 105 South/East Fire-Lite CPD 7051 Ionization August, 2003
Zone 2: 2nd Floor Bldg 1: Second Floor
2-1 Top of West Stairs Fire-Lite BG-10 Pull Station 2-2 Top of West Stairs Fire-Lite CPD 7051 Ionization August, 2003 2-3 Hall 201 West Fire-Lite CPD 7051 Ionization August, 2003 2-4 Hall 201 East Fire-Lite CPD 7051 Ionization August, 2003 2-5 Top of East Stairs Fire-Lite BG-10 Pull Station 2-6 Top of East Stairs Fire-Lite CPD 7051 Ionization August, 2003 2-7 Room 214 Fire-Lite CPD 7051 Ionization August, 2003
Zone 3: Basement 3-1 Tamper - OS&Y Federal OS&Y Supervisory 3-2 Tamper - OS&Y Federal OS&Y Supervisory 3-3 Pressure Switch - AIR United Electric Low air Supervisory 3-4 Pressure Switch - WATER Auto. Sprinkler Water Flow Supervisory
Crater Lake National Park Fire Alarm System Inventory & Locations
2 CRLA Building 2 (Steel) Zone Location Manufacturer Device Type Installed/Replaced
Zone 1 Bldg 2: First Floor FACP Notifier SFP-2404 Additional Panel December, 2007 batteries 1-1 Projection Room FCI 601 ROR Heat 1-2 Storage Alcove FCI CPD 7021 Ionization 1-3 Furnace Room (basement) FCI 601 ROR Heat June, 2005 1-4 Visitor Center West FCI CPD 7021 Ionization 1-5 Visitor Center East FCI 2400 Photoelectric 1-6 Front Entry FCI MS-2 Pull Station 1-7 North Hall South End FCI CPD 7051 Ionization August, 2003 1-8 North Hall North End FCI CPD 7021 Ionization 1-9 North Entrance FCI MS-2 Pull Station 1-10 Northeast Office FCI 601 ROR Heat June, 2005 1-11 Post Office FCI CPD 7021 Ionization 1-12 Janitor Closet by Post Office FCI 601 ROR Heat June, 2005 1-13 Theater North End FCI CPD 7021 Ionization 1-14 Theater East Exit FCI MS-2 Pull Station 1-15 Theater South End FCI CPD 7021 Ionization 1-16 Theater South Exit FCI MS-2 Pull Station
Bldg 2: Second Floor 1-17 Top of South Stairs FCI CPD 7021 Ionization August, 2003 1-18 AV Storage Closet FCI 601? ROR Heat June, 2005 1-19 Workroom South End FCI CPD 7021 Ionization August, 2003 1-20 Attic South End FCI 601? ROR Heat 1-21 Workroom North End FCI CPD 7021 Ionization August, 2003 1-22 Upstairs Hall Middle FCI CPD 7021 Ionization 1-23 Middle Office FCI CPD 7021 Ionization 1-24 Attic FCI 601? ROR Heat 1-25 East Office FCI CPD 7021 Ionization 1-26 Top of Main Stairs FCI MS-2 Pull Station 1-27 Top of Main Stairs FCI CPD 7021 Ionization August, 2003 1-28 Attic FCI 601? ROR Heat 1-29 Elec Room FCI 601? ROR Heat 1-30 NW Office FCI 601? ROR Heat June, 2005 1-31 Upstairs Hall North FCI CPD 7021 Ionization 1-32 Library FCI CPD 7021 Ionization August, 2003 1-33 Attic FCI 601? ROR Heat June, 2005 1-34 Museum FCI CPD 7021 Ionization 1-35 Crawl Space FCI 601? ROR Heat
3 CRLA Building 3 (Canfield)
Zone 1: Bldg 3: First Floor In Communications Center (Dispatch) FCI-72 BMFC-6 FACP batteries Across from Comm Center (Storage) unknown Additional Panel In Communications Center (Dispatch) Silent Knight 5230 Annunciator batteries
1-1 Front Door Fire Contr Instr MS-6 Pull Station 1-2 Front Entry FCI CPD 7051 Ionization August, 2003 1-3 Dispatch FCI CPD 7021 Ionization 1-4 Hall by 114 FCI CPD 7021 Ionization 1-5 Hall by back door FCI CPD 7021 Ionization 1-6 By back door FCI MS-6 Pull Station 1-7 Hall by 109 FCI CPD 7021 Ionization 1-8 Hall by 107 FCI CPD 7021 Ionization 1-9 End of Hall East end FCI MS-6 Pull Station
Bldg 3: Second Floor 1-10 Room 201 East FCI CPD 7051 Ionization August, 2003 1-11 By West Stairs FCI MS-6 Pull Station 1-12 Room 201 West FCI CPD 7021 Ionization 1-13 Room 202 FCI CPD 7021 Ionization 1-14 Top of East Stairs FCI MS-6 Pull Station 1-15 Room 206 FCI CPD 7021 Ionization
Bldg 3: Third Floor (Attic) 1-16 West end FCI 601 ROR Heat 1-17 West end FCI 601 ROR Heat 1-18 Top of West Stairs FCI 601 ROR Heat 1-19 Room 301 (attic) FCI 601 ROR Heat 1-20 Room 301 (attic) FCI 601 ROR Heat 1-21 Room 301 (attic) FCI 601 ROR Heat 1-22 Room 301 (attic) FCI 601 ROR Heat 1-23 Room 301 (attic) FCI 601 ROR Heat 1-24 Top of East Stairs FCI 601 ROR Heat 1-25 East end FCI 601 ROR Heat 1-26 East end FCI 601 ROR Heat
Zone 2: Sprinklers Zone 2: Sprinklers 2-1 Pressure Switch
Tamper Switch
4 CRLA Building 4 (Warehouse) Location Manufacturer Device Type Installed/Replaced
FACP Silent Knight SK-4 SK-5208 2010 batteries
Zone 1 S & R Cache FCI 601 ROR Heat 2010 Zone 2 S & R Cache Viking VSR-F Pressure Switch 2010 Zone 2 S & R Cache Potter OSYU-A Tamper Switch 2010 Zone 3 S & R Cache FCI MS-2 Pull Station 2010 Zone 3 Storage area FCI MS-2 Pull Station 2010 Zone 3 Fire Cache FCI MS-2 Pull Station 2010 Zone 4 S & R Cache FCI Simplex Audible/visible alarm 2010 Zone 4 Storage area FCI Simplex Audible/visible alarm 2010 Zone 4 Fire Cache FCI Simplex Audible/visible alarm 2010
5 CRLA Building 5 (Rat Hall) Location Manufacturer Device Type Installed/Replaced
Bldg 5: Garage Bay FACP Right of Entry Door Silent Knight SK-4 SK-5208 2013 Batteries
Zone 1 Sprinkler System Potter PS-10 Water Flow 2013 Zone 2 Sprinkler Valve Victaulic Firelock 702 Valve Tamper 2013 Zone 3 Sprinkler Valve Potter PS-40-2 Air Pressure Supervisor 2013
Right of entry door Fire-Lite BG-12 Pull Station 2013 Zone 5 Between Bay 1 & 2 Gentex GCC/GCS Audible/visible Alarm 2013
Bay 4 Gentex GCC/GCS Audible/visible Alarm 2013 System Sensor SSM Bell 2013
Bldg 5: Second Floor Zone 6 Right of entry door Fire-Lite BG-12 Pull Station 2013 Zone 6 End of hallway Gentex GES3 Audible/visible Alarm 2013 Zone 6 Bldg 5 Attic Zone 6 Ceiling left of stairs Gentex GCC/GCS Audible/visible Alarm 2013 Zone 6 Ceiling right of stairs Gentex GCC/GCS Audible/visible Alarm 2014
CRLA Building 14 (Maintenance)
Zone 2 Bldg 14: First Floor FCI batteries Bay 1 FCI FCI 72 Additional panel
2-1 By Used Oil FCI MS-2 Pull Station 2-2 Boiler Room FCI MS-2 Pull Station
Zone 3 Carpentry & Plumbing FCI 3-1 Carpentry Shop FCI MS-2 Pull Station 3-2 Bottom of Stairs FCI MS-2 Pull Station
Zone 4 Zone 4 Flammable Storage Cutoff RooFCI 4-1 Flammable Storage FCI 302EPM? Heat June, 2005 4-2 Flammable Storage FCI EXP Pull Station
Zone 5 Zone 5 Second Floor Offices etc FCI 5-1 Top of South Stairs FCI MS-2 Pull Station 5-2 Top of North Stairs FCI MS-2 Pull Station 5-3 Top of North Stairs FCI FCI 301P Photoelectric 5-4 Bldgs Foreman Office FCI FCI 301P Photoelectric 5-5 Office 201 FCI FCI 301P Photoelectric 5-6 Hall outside Office 201 FCI FCI 301P Photoelectric 5-7 Office 204 FCI FCI 301P Photoelectric 5-8 Hall by Bell FCI FCI 301P Photoelectric 5-9 Women's Restroom FCI 601? Heat June, 2005 5-10 Hall outside Men's Restroom FCI FCI 301P Photoelectric 5-11 Men's Restroom FCI 601? Heat June, 2005 5-12 Lunchroom North FCI FCI 301P Photoelectric 5-13 Lunchroom South FCI 601? Heat June, 2005 5-14 Top of Elevator Shaft FCI FCI 301P Photoelectric
Zone 6 Zone 6 Sprinkler System 6-1 Carp Shop Sprinkler System Viking VSR-F Waterflow 6-2 Carp Shop Sprinkler Valve Potter OSYU-A Tamper
Zone 7 Zone 7 Duct Detector in Attic 7-1 Duct Detector FCI DH3011 7-1
Annunciator in Ambulance Bay Silent Knight 5230 Annunciator
7 CRLA Building 36 (old Phone)
Other Panel Fire Lite Miniscan 424A Additional Panel Batteries Front Entrance Photoelectric Back of Building Photoelectric By Front Door Pull Station Back of Building Pull Station
8 CRLA Building 66 (Kiser) Zone Location Manufacturer Device Type Installed/Replaced
Bldg 66 First Floor Storage Room Silent Knight IFP-50 FACP batteries
1-1 Front Door Simplex? 4099-9001 Pull Station 1-2 Back Door Simplex? 4099-9001 Pull Station 1-3 Storage Silent Knight SD505APS Photoelectric 1-4 Staff Restroom Silent Knight SD505APS Photoelectric 1-5 Visitor Center Silent Knight SD505APS Photoelectric 1-6 Visitor Center? Silent Knight SD505APS Photoelectric 1-7 Visitor Center? Silent Knight SD505APS Photoelectric 1-8 Attic? Silent Knight BD-505-AHS Heat
Sprinkler Waterflow Potter PS10A Water Flow Air Pressure Pressure Switch Sprinkler Tamper
9 CRLA Building 67 (Sinnott) Zone Location Manufacturer Device Type Installed/Replaced
Building 67 First Floor 1-1 Basement Workroom (103) Silent Knight SD505APS Photoelectric 2002 1-2 Main Display Room (102) Silent Knight SD505APS Photoelectric 2002 1-3 Main Display Room (102) Silent Knight SD505APS Photoelectric 2002 1-4 Main Display Room (102) Silent Knight SD505APS Photoelectric 2002 1-5 Front Door Simplex? 4099-9001 Pull Station 2002 1-6 Basement Door Simplex? 4099-9001 Pull Station 2002 10 CRLA Building 68 (Comfort Station)
Zone Location Manufacturer Device Type Installed/Replaced Building 68
1-1 Janitor's Closet Simplex 4098-9757 Photoelectric 1-2 Men's Restroom Simplex 4098-9757 Photoelectric 2002 1-3 Women's Restroom Simplex 4098-9757 Photoelectric 2002 note - the alarm components in Bldg 67 report to the FACP in Bldg 66 note - the alarm components in Bldg 68 report to the FACP in Bldg 116
Building 116 (Community House)First Floor
Base of Stairs Simplex 4010-9101 FACP 2002 batteries
1-1 Front Door Simplex 4099-9001 Pull Station 2002 1-2 Back Door Simplex 4099-9001 Pull Station 2002 1-3 Main Floor North Simplex 4098-9757 Photoelectric 2002 1-4 Janitor's Closet Simplex 4098-9757 Photoelectric 2002 1-5 Main Hall South Simplex 4098-9757 Photoelectric 2002 1-6 Equipment Room Simplex 4098-9757 Photoelectric 2002 1-7 Storage Simplex 4098-9757 Photoelectric 2002 1-8 Hall West Simplex 4098-9757 Photoelectric 2002 1-9 Hall West Simplex 4098-9757 Photoelectric 2002 1-10 Waterflow Potter VSR-F
OS&Y Tamper
Zone Location Manufacturer Device Type Installed/Replaced
1st floor Panel A Johnson Control 21326030A Fire Panel 2009 1st floor 2 ea East & West entrtance doors Johnson Control Pull stations 2009
1st floor 7ea random sites Johnson Control Audible/visible alarm 2009 1st floor 8ea random sites FCI FCI 301P Photoelectric 2009 1st floor Mechanical room Potter PS10A Pressure Switch 2009 1st floor Mechanical room Potter PS10A Water Flow 2009 1st floor Mechanical room Victaulic Tamper 2009 1st floor West entrance Defibrillator cabinet 2009 2nd floor 2 ea East & West entertance doors Johnson Control Pull stations 2009 2nd floor 6ea random sites Johnson Control Audible/visible alarm 2009 2nd floor 9ea random sites FCI FCI 301P Photoelectric 2009 2nd floor 2ea Johnson Control Magnetic door release 2009
CRLA Building 116 (Community House)
CRLA Building 222 (Community Ctr)
13 CRLA Building 19 (Science & Learning Center) Location Manufacturer Device Type Installed/Replaced
Bldg. 19: Basement Mechanical room Silent Knight IFP-50 Fire Panel 2006
Batteries Garage Gentex 710CS Photoelectric 2006
Bldg.19 First Floor Office Rm 101 Gentex 710CS Photoelectric 2006 local only Foyer Rm 107 Gentex 710CS Photoelectric 2006 don't report Living Rm 102 Gentex 710CS Photoelectric 2006 to FACP Dinning Rm 103 Gentex 710CS Photoelectric 2006
Rear entry RM109 Gentex Strobe GES3 2006 Rear entry RM109 Silent Knight SD500-PS Pull Station 2006 only sprinklers Bldg. 19 Second Floor and pull stns South office Rm 201 Gentex 710CS Photoelectric 2006
East office Rm 207 Gentex 710CS Photoelectric 2006 North office RM 212 Gentex 710CS Photoelectric 2006 West office Rm 206 Gentex 710CS Photoelectric 2006 Hallway Rm 205 Gentex 710CS Photoelectric 2006
Bldg 19 Sprinkler Supervisory Valve Tamper 2006 Basement Garage Waterflow Switch 2006
Air Pressure Switch 2006 Alarm Bell 2006
Location Manufacturer Device Type Installed/Replaced
Bldg.20 First Floor Bedroom closet Rm 107 Silent Knight IFP-50 Fire Panel 2006
Batteries Bedroom Rm 106 Gentex 710CS Photoelectric 2006 Living Rm 103 Gentex 710CS Photoelectric 2006 Dining Rm 102 Gentex 710CS Photoelectric 2006 local only Kitchen Rm 101 Gentex 710CS Photoelectric 2006 don't report to FACP Bldg. 20 Second Floor Storage room Rm 207 Gentex 710CS Photoelectric 2006 East bedroom Rm 205 Gentex 710CS Photoelectric 2006 West bedroom Rm 203 Gentex 710CS Photoelectric 2006 only sprinklers Bldg 20 Fire Sprinkler Supervisory and pull stns Kitchen Rm 101 Valve Tamper 2006
Kitchen Rm 101 Waterflow 2006 Kitchen Rm 101 Pressure Switch 2006 Kitchen Rm 101 Alarm Bell 2006
Gentex Strobe GES3 2006 Silent Knight Pull Station SD500-PS 2006