Item DESCRIPTION QUANTITY UNIT

UNIT

COST

TOTAL

COST NOTES

SUBMITTAL

REQUIRED

FOUNDATION / FLOOR

4 x 12 x 12' Pressure Treated Wood Timbers for foundation, American Wood Protection Association (AWPA) Category UC4B (ground contact, heavy duty), wood to be treated with waterborne preservative ACQ, ACZA, or CA-C 24 EA large timbers to be used as cabin foundation blocks cutsheet

6 x 6 x 8' SPF, No. 2 and better (Hem-Fir also acceptable, Douglas-fir may be acceptable with approval of the Contracting Officer) 4 EA porch framing, minimum 8' lengths

3-1/2 x 12 x 26' Engineered Microlam Beam, VersaLam or approved equal 4 EA foundation longitudinal rim beam cutsheet

3-1/2 x 12 x 18' Engineered Microlam Beam, VersaLam or approved equal 4 EA foundation transverse rim beam

2-5/16 x 11-7/8 x 18' Engineered Wood I-Joists, TJI 360, BCI 60, or approved equal. 40 EA floor joists, note requirement for joists with large top and bottom flange width and thickness cutsheet

2-5/16 x 11-7/8 Top Flange Joist Hanger for wood I-joists above, Simpson or approved equal 78 EA top flange hangers cutsheet

7 3/4" x 4 x 8 Tongue & Groove ACX Plywood 32 EA floor diaphragm

8 1/2" x 4 x 8 CDX Plywood 32 EA bottom of joist, insulation block, see also item 15 under "Exterior Walls" for additional 1/2" CDX plywood

2 x 6 x 16' Pressure Treated Lumber, not incised; American Wood Protection Association (AWPA) Category UC3B (exterior deck), wood to be treated with waterborne preservative ACQ, ACZA, or CA-B (CCA and DOT not acceptable) 12 EA front porch deck cutsheet

Sub-Floor Adhesive, 28 oz. tube, Loctite, Titebond, Liquid Nails, or equal 12 EA

R-38 Fiberglas Batt Insulation, unfaced, for floor joists spaced 16" o.c. 1000 SF floor, 21 bags if 1 bag = 48 SF

BUILDING MATERIAL LIST WORKSHEET

SUPPLY BUILDING MATERIALS FOR TWO CABINS AT DENALI NATIONAL PARK

2015 - 2016 SCHOOL-TO-WORK CABINS

Quantities Below Represent Materials Needed for Construction of Two Cabins

COST

TOTAL

COST NOTES

SUBMITTAL

REQUIRED

EXTERIOR WALLS

General Specifications for dimensioned lumber: provide SPF No. 2 and better; Stud and Utility Grades are not acceptable (lumber is used for Building Trades student project, and building will be moved by truck to its final location). Good quality straight-grained Hem-Fir is acceptable; Douglas-fir can be accepted with approval of the Contracting Officer.

2 x 6 x 92-5/8" Precut Wall Stud, SPF or Hem-Fir No. 2 and better, kiln-dried 200 EA exterior wall studs

13 2 x 6 x 16' SPF or Hem-Fir No. 2 and better, kiln dried 100 EA top and bottom plates, bracing, etc.

14 2 x 8 x 16' SPF or Hem-Fir No. 2 and better, kiln dried 11 EA headers for doors and windows

15 1/2" x 4 x 8 CDX Plywood 60 EA wall sheathing, see also item 8 under "Foundation / Floor" for additional 1/2" CDX plywood

1/2" x 4 x 8 Textured Rough-Sawn No-Groove Douglas-Fir Plywood (Rough-Tex) 13 EA soffit cutsheet

17 House Wrap, 9' wide, 100' long, Tyvek or equal 2 ROLL building wrap, 100 ft roll 18 House Wrap Tape, 2" x 165' roll, Tyvek or equal 3 ROLL tape for building wrap

2" x 2' x 8' Rigid Foam Insulation Board, extruded polystyrene (XPS), minimum 25 psi compressive strength, Dow Styrofoam Blue Board, Owens Corning Formular Pink Board, or equal 10 EA

Insulation for door and window headers, etc.

INTERIOR WALLS

2 x 4 x 92-5/8" Precut Wall Stud, SPF or Hem-Fir No. 2 and better, kiln-dried 55 EA interior wall studs

21 2 x 4 x 16' SPF or Hem-Fir No.2 or better, kiln-dried 100 EA top and bottom plates, bracing, etc.

COST

TOTAL

COST NOTES

SUBMITTAL

REQUIRED

ROOF FRAMING

General specifications for Engineered Wood Trusses:

Truss to be 5/12 pitch, 18' span (outside face of stud to outside face of stud), 18" rafter tail (outside face of wall to end of rafter tail), rafter tail to be plumb cut, top and bottom chords to be 2x6.

All trusses to have 11 1/4" energy heel.

Design trusses for 100 psf top chord live load and 120 mph wind load. See attached Drawing A-1.

Note: 4 Common Trusses are placed above bedrooms, on 2' centers, and 2' from first scissor truss.

Note: 8 Scissor Trusses are placed above living/kitchen area, on 2' centers, and 2' from last common truss.

Note: Gable End Trusses are placed at both end walls, and at wall separating bedrooms from living area - intermediate gable end truss is not on 2' centers.

Verify length of Top Chord, from peak to plumb-cut rafter tail, along top of Top Chord is 11' - 4 1/2".

See attached Truss Layout Sketch, SK-1, and Truss Types Sketches, SK-2 and SK-3.

provide standard truss shop drawings

22 Energy Heel Scissors Truss 16 EA scissors truss for living / dining / kitchen area, and for porch

23 Energy Heel Common Truss 8 EA common truss for bedroom areas

Gable End Truss with no king post for end walls with gable end vent 4 EA gable end truss for 2 exterior walls, each cabin

Gable End Truss with king post for interior partition wall at vaulted ceiling 2 EA gable end truss for interior wall, each cabin

26 5/8" x 4 x 8 CDX Plywood 50 EA roof sheathing 27 Hurricane Ties for trusses; Simpson H1 or equal. 54 EA connect truss to top of wall

COST

TOTAL

COST NOTES

SUBMITTAL

REQUIRED

ROOFING MATERIALS

Self adhering rubberized asphaltic water proofing membrane for roofing, 40 mil thick, 3' wide rolls 75' length, Grace Ice & Water Shield or equal. 9 ROLL roof waterproofing cutsheet General specifications for metal roofing materials:

Metal roofing, 26 gauge, direct fastened, integral rib roof panel, with 16" wide pan and 1" high standing seams. Color is ASC Everglade Green. All flashing and exposed screws shall be from one manufacturer and shall match in color. ASC Skyline Roofing, or Metal Sales Image 2 Roofing, or approved equal. All metal roofing products to be crated for proper shipping to site.

cutsheet or brochure indicating mfr and color

Metal Roofing Panels, 26 gauge, 16" wide; length to match top chord of truss. Panels should be 11' - 4 1/2" long. Crated. 95 EA roof panels; Vendor is responsible for coordinating with truss manufacturer and metal supplier.

Metal Ridge Cap, manufacturer's standard profile, minimum 5 1/2" legs, 135° ridge angle, 10' lengths. ASC R16, Metal Sales 10" Ridge Cover, or equal. Crated. 8 EA ridge cap

Gable End Flashing, manufacturer's standard profile, minimum 4" vertical leg, 10' lengths. ASC G17, Metal Sales "Image II Step Rake", or equal. Crated. 10 EA rake flashing

Eave Flashing, "snow eave" with overhang brake, 5" extension up roof and bent for plumb cut rafter tails on 5/12 roof, 113° eave angle, 10' lengths. ASC E18, Metal Sales "Extended Eave", or equal. Crated. 14 EA eave flashing

Metal Roof Fastener, No. 10 x 1" Pancake Head Screw, 250 screws/bag. 5 BAG for attaching panels to plywood sheathing

Metal Roof Fastener, No. 14 x 1" Hex-head Wood Screw, with ASC Everglade Green head, 250 screws/bag. 4 BAG for exposed fasteners attaching panels to plywood sheathing

Metal Roof Fastener, No. 12 x 3/4" Stitch Screw, with ASC Everglade Green head, 250 screws/bag. 2 BAG for attaching metal to metal

36 12" X 12" Gable End Vent, metal, standard brown finish. 4 EA gable end vent 37 1/4" Mesh Screen for Soffit Vent, wire mesh, 4" wide, 100 ft roll. 1 ROLL soffit vent screen

COST

TOTAL

COST NOTES

SUBMITTAL

REQUIRED

EXTERIOR SIDING & INTERIOR PANELS

1 x 6 x 16' Tight Knot Pine Siding, beveled shiplap, WWPA Standard Profile No. WP-11, unfinished 280 EA for exterior siding on walls cutsheet

1 x 8 x 12' Tight Knot Pine, no profile, S4S, do not ease edges, unfinished 52 EA for board and batt on gable ends

1/2" x 4 x 8 MDO Plywood (Medium Density Overlay), overlay one side only 100 EA interior wall sheathing / finished wall surface; see also closet shelf materials below cutsheet

41 1/4" x 1-1/2" x 8' Pine Batten, Grade C and better 40 EA batten strip for interior walls

INTERIOR CEILING AND TRIM

1 x 6 x 16' T&G Tight Knot Pine, V-groove ceiling (WWPA Standard Profile No. E & CV Ceiling), unfinished 100 EA interior ceiling, 16' lengths cutsheet

1 x 6 x 10' T&G Tight Knot Pine, V-groove ceiling (WWPA Standard Profile No. E & CV Ceiling), unfinished 100 EA interior ceiling, 10' lengths

44 1 x 8 x 12' Pine, Grade C and better, S4S 8 EA misc 45 1 x 6 x 16' Pine, Grade C and better, S4S 20 EA wood base 46 1 x 6 x 12' Pine, Grade C and better, S4S 15 EA 47 1 x 4 x 16' Pine, Grade C and better, S4S 64 EA door and window casing 48 1 x 4 x 12' Pine, Grade C and better, S4S 44 EA

EXTERIOR CEDAR TRIM

2 x 12 x 16' Cedar, A Grade or better, random lengths acceptable, 256 LF total required 16 EA belly band

2 x 4 x 16' Cedar, A Grade or better, random lengths acceptable, 320 LF total required 20 EA drip edge above belly band

1 x 8 x 14' Cedar, A Grade or better, random lengths acceptable, 280 LF total required 20 EA eave, barge trim, gable

1 x 4 x 16' Cedar, A Grade or better, random lengths acceptable, 8' length minimum, 896 LF total required 56 EA exterior trim (window, door, etc.)

1 x 4 x 10' Cedar, A Grade or better, random lengths acceptable, 8' length minimum, 220 LF total required 22 EA corner trim

COST

TOTAL

COST NOTES

SUBMITTAL

REQUIRED

INSULATION

cutsheet

R-21 Fiberglass Batt Insulation, unfaced, for 2x6 wood studs spaced at 16" o.c. 1760 SF exterior walls, 26 bags if 1 bag = 67.8 SF

R-11 Fiberglass Batt Insulation, kraft faced, for 2x4 wood studs spaced 16" o.c. 450 SF interior walls, 3 bags if 1 bag = 155 SF

R-38 Fiberglass Batt Insulation, kraft faced, for wood trusses spaced 24" o.c. 1150 SF ceiling, 16 bags if 1 bag = 72 SF

57 Clear Polyethylene Sheeting, 10' X 100' X 6 MIL 4 ROLL vapor barrier 58 2 1/2" Red Polypropylene Vapor Barrier Tape, 72 yard roll 4 ROLL vapor barrier tape

DOORS

Exterior Fiberglass Door, 3'-0" x 6-'8", pre-hung on 5/4" pine frame, 6-9/16" jamb. Smooth (no grain), two panel door with half light. Solid polyurethane core, double pane, tempered lite; LEFT HAND door. With single bore for cylindrical lockset (no deadbolt), 2 3/4" backset; with ball bearing hinges, satin chrome finish; with threshold and full complete gasketing and weatherstripping.

Primed, paint grade frame. Crated. 1 EA cutsheet

Exterior Fiberglass Door, 3'-0" x 6-'8", pre-hung on 5/4" pine frame, 6-9/16" jamb. Smooth (no grain), two panel door with half light. Solid polyurethane core, double pane, tempered lite;

RIGHT HAND door. With single bore for cylindrical lockset (no deadbolt), 2 3/4" backset; with ball bearing hinges, satin chrome finish; with threshold and full complete gasketing and weatherstripping. Primed, paint grade frame. Crated. 1 EA

Interior Wood Door, 3'-0" x 6'-8", pre-hung on 5/4" pine frame, 4-9/16 jamb. Flush panel birch veneer door with solid wood fiber core. Door slab 1 3/4" thick with Grade A select white birch veneer. LEFT HAND door. With single bore for cylindrical lockset, 2 3/4" backset; with steel hinges, brass finish. Stain grade door and frame. Crated. 2 EA cutsheet

Interior Wood Door, 3'-0" x 6'-8", pre-hung on 5/4" pine frame, 4-9/16 jamb. Flush panel birch veneer door with solid wood fiber core. Door slab 1 3/4" thick with Grade A select white birch veneer. RIGHT HAND door. With single bore for cylindrical lockset, 2 3/4" backset; with steel hinges, brass finish. Stain grade door and frame. Crated. 2 EA

COST

TOTAL

COST NOTES

SUBMITTAL

REQUIRED

VINYL WINDOWS

General specifications for windows: vinyl frame windows, 3 3/8" thick frame, double pane glazing, minimum 1/8" thick glass each lite ("double strength glass"), low E glazing, argon filled, warm edge spacers. Maximum whole window U-value of 0.34. With fiberglass screens. Color "Almond". No muntins. Atrium Windows Series 9050. Alpine Windows Series 80, or approved equal. Crated.

Double strength (1/8" thick) glass is essential for durability in cold climate.

provide standard mfr's data

(Window Type 1) 56" X 42" Mulled Combination Window (Casement/Casement), 28"x42" left hand plus 28"x42" right hand casement units 4 EA

R.O. should be 56" x 42", please advise if different.

(Window Type 2) 56" X 32" Mulled Combination Window (Fixed/Fixed), 28"x32" fixed unit plus 28"x32" fixed unit, joined together to make one window unit 2 EA window is fixed because it is above direct vent heater exhaust R.O. should be 56" x 32", please advise if different.

(Window Type 3 - Egress Window) 36" x 42" Casement Egress Window, LEFT HAND 2 EA

R.O. should be 36" x 42", please advise if different.

(Window Type 3 - Egress Window) 36" x 42" Casement Egress Window, RIGHT HAND 2 EA

(Window Type 4) 28" X 32" Casement Window LEFT HAND 2 EA

R.O. should be 28" x 32", please advise if different.

(Window Type 4) 28" X 32" Casement Window RIGHT HAND 2 EA

FLOORING

Laminate Flooring, Snap-Fit / No-Glue planks with attached underlayment, planks minimum 7mm thick, underlayment minimum 2 mm thick. Nominal 8"x4' planks with 3-strip pattern, and square edge. With high-density fiberboard core and transparent overlay with 5 year warranty. Butterscotch Oak other pattern as selected by the Contracting Officer. QuickStep Homesound, or approved equal. 1082 SF cutsheet

Floor Transition Strip (for doorways), 8' length (other lengths acceptable - 16 LF required) 2 EA

COST

TOTAL

COST NOTES

SUBMITTAL

REQUIRED

CABINETS

General specifications for cabinets: Wood cabinet, with Solid Wood door rails and drawer fronts. Back panel, bottom panel, end panels and shelves to be minimum 48 pcf density engineered wood with wood laminate (not vinyl laminate).

Drawer guides rated for minimum 75 pounds. With adjustable, self closing, concealed hinges. All cabinets and accessories to be from one manufacturer. Base Cabinets 24" deep and 34.5" high; Wall Cabinets 12" deep. Color to be Natural Oak. Merillat Classic cabinets, Spring Valley line, or approved equal.

See Cabinet Sketches SK-5 and

SK-6

provide mfr's brochure and cabinet details

71 Base cabinet, 12" wide, with 4 drawers 2 EA

Base cabinet, 12" wide, top drawer, 1 full depth adjustable shelf, hinge on right 1 EA

Base cabinet, 12" wide, top drawer, 1 full depth adjustable shelf, hinge on left 1 EA

Corner Sink base cabinet, corner diagonal unit, 36" wide (at rear of both sides), sides not finished, hinge on left; full box construction required ("diagonal sink base"). Front only ("diagonal sink front") is not acceptable. 1 EA

Corner Sink base cabinet, corner diagonal unit, 36" wide (at rear of both sides), sides not finished, hinge on right; full box construction required ("diagonal sink base"). Front only ("diagonal sink front") is not acceptable. 1 EA

Base cabinet, 18" wide, top drawer, 1 full depth adjustable shelf, hinge on right 2 EA

Base cabinet, 18" wide, top drawer, 1 full depth adjustable shelf, hinge on left 2 EA

Base cabinet, corner unit with lazy susan, 36" wide (at rear of both sides), "Super Susan" style unit with fixed shelves and turntable on bearings, hinged bi-fold door, sides not finished, hinge on left 1 EA

Base cabinet, corner unit with lazy susan, 36" wide (at rear of both sides), "Super Susan" style unit with fixed shelves and turntable on bearings, hinged bi-fold door, sides not finished, hinge on right 1 EA

Wall cabinet, 18" wide, 30" high, with 2 adjustable shelves, hinge on left 1 EA

COST

TOTAL

COST NOTES

SUBMITTAL

REQUIRED

Wall cabinet, 18" wide, 30" high, with 2 adjustable shelves, hinge on right 1 EA

Wall cabinet, 21" wide, 30" high, with 2 adjustable shelves, hinge on left 1 EA

Wall cabinet, 21" wide, 30" high, with 2 adjustable shelves, hinge on right 1 EA

84 Wall cabinet, 30" wide, 15" high, sides not finished, double door 2 EA place above oven/range 85 Toe kick to match cabinets, 8' length. 4 EA 86 Outside corner molding to match cabinets, 8' length. 2 EA

CLOSET SHELF AND ROD

87 1/2" x 4 x 8 MDO Plywood (Medium Density Overlay) 8 EA 88 Closet Rod, wood, 8' 4 EA 89 Closet Rod End Support 8 EA

ELECTRICAL

Square D Combination Service Entrance / Meter Base with 125A main disconnect, Part No. C125RB - all one unit. 2 EA

All 32 C Camp Cabins to date use Square D, QO series equipment cutsheet

Square D Flush Mount Panel, QO Series, 125A main lug, 12 space. 2 EA cutsheet

92 Square D Cover for above panel, flush mount. 2 EA 93 Square D 125A breaker, QO Series. 2 EA cutsheet 94 Square D 20A single pole breaker, QO Series. 10 EA 95 Square D 20A single pole GFI breaker, QO Series. 4 EA 96 Square D 20A single pole arc fault breaker, QO Series. 4 EA

Nail-on electrical box, fiberglass, single gang, with vapor barrier gasket. 40 EA

Vapor Barrier must be cemented to exterior of box opening

Nail-on electrical box, fiberglass, double gang, with vapor barrier gasket. 6 EA

Vapor Barrier must be cemented to exterior of box opening

Nail-on electrical box, fiberglass, 4" round, with vapor barrier gasket. 20 EA

Vapor Barrier must be cemented to exterior of box opening

100 20A Duplex Receptacles, ivory. 46 EA 101 20A GFI Duplex Receptacle, ivory. 2 EA 102 20A Single Pole Switch, ivory. 12 EA 103 #12-2 Romex with Ground Wire, 1000 ft rolls 2 ROLL must be in 1000 ft rolls 104 Ground Rod, 5/8" x 8' 2 EA 105 Ground Clamp for above 2 EA

COST

TOTAL

COST NOTES

SUBMITTAL

REQUIRED

Ceiling mount light fixture, 3 bulb, flush mount, round light, contemporary, compatible with compact fluorescent bulbs;

Kichler Lytham 42275NI, or approved equal 4 EA 2 flush mount light fixtures for main room cutsheet

Ceiling mount light fixture, 3 bulb, pendant mount, round light, contemporary, compatible with compact fluorescent bulbs;

Kichler Lytham 42245NI, or approved equal 2 EA pendant fixture over breakfast bar cutsheet

Ceiling mount light fixture, 2 bulb, round pan fixture, color white, Progress #P4609-30, or approved equal 4 EA bedroom light fixtures cutsheet

Ceiling mount porch light; 1 bulb, Acclaim Builders Choice 4901BK, or approved equal 2 EA porch light cutsheet

END OF LIST