P01-3. VA Brockton Mental Health Off 21Nov SATInstall R0 (1).pdf

PDF 9 MB Posted

Attached to
7110-- Amendment 1 to extend the Due date to 31 March 2023-Demountable Wall System Federal contract opportunity
Solicitation number
36C24123Q0460
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1

View the file

Other files for this federal contract opportunity

Other files attached to 7110-- Amendment 1 to extend the Due date to 31 March 2023-Demountable Wall System, newest first.
File Type Posted
36C24123Q0460 0001.docx DOCX document
P07-WD WAGE DET DEMOUNTABLE WALL.pdf PDF
P01 1. VABHS Brockton Bldg 3 SOW Modular Walls MH Service.pdf PDF
P01-2. Outpatient MH Services Layout 3 Phase 2.pdf PDF
36C24123Q0460.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GROUP

ROOM

A-404A

CONSULT

ROOM

B-401A

MULTI-PURPOSE

ROOM

B-429

CONSULT

ROOM

B-430

CONSULT

ROOM

B-431

CONSULT

ROOM

B-401B

CONSULT

ROOM

B-428

CLOSET

B-426

MEN'S

RESTROOM

B-425

WOMEN'S

RESTROOM

B-424

CONSULT

ROOM

B-422D

CONSULT

ROOM

B-422?

CONSULT

ROOM

B-422?

CONSULT

ROOM

B-422A

CONSULT

ROOM

B-421A

CONSULT

ROOM

B-420A

CONSULT

ROOM

B-416

CONSULT

ROOM

B-405

CONSULT

ROOM

B-406

CONSULT

ROOM

B-407

CONSULT

ROOM

B-408

CONSULT

ROOM

B-409

CONSULT

ROOM

B-410

CONSULT

ROOM

B-411

CONSULT

ROOM

B-412

CONSULT

ROOM

B-413

CONSULT

ROOM

B-414

CONSULT

ROOM

B-415

CORRIDOR

CRB402

B-412A B-409A

B-407AB-414A

B-406AB-415A

B-405AB-416A

B-417

B-418

B-418A

B-419

B-404

B-403

EMS

CLOSET

B-402

CORRIDOR

CRB401

ST2B401

FCB401

WHOLE

HEALTH

OFFICE

A-405

CONSULT

ROOM

B-420B

CONSULT

ROOM

B-421B

TEL/DATA

B-428A

CONSULT

ROOM

B-422B

CONSULT

ROOM

B-422?

C1C1

C2

C

C

C2

F1 F1

F1

F4

BH

F1

HD

BH

F1

F5F5

F4

BH

F2

HD

BH

F2

C2

C1C1

C

C

C2

F1

F7

BH

F1

HD

BH

F1

F4

F8 F8

BH

F2

HD

BH

F2

F9

C2

C1C1

C

C

C2

C

C

C2 C2

C1C1

C

C

C2

C1C1C1C1

C2C2 C2

C

C

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F4

BH

F1

HD

BH

F1

F2

BH

F2

HD

BH

F2

C

F21F21

F4

BH

F2

HD

BH

F2

F4

BH

F1

HD

BH

F1

F22F22

F4

BH

F2

HD

BH

F2

F23 F24

BHF1

HD

BHF1

F4

BHF2

HD

BHF2

F25

F26F26

F2

BH

F1

HD

BH

F1

L2 S

G

L2S G

L2S G

L2 S

G

L2 S

G

L2S G

L2 S

G

L2S G

L2 S

G

L2S G

L2 S

G

L2S G

DRAWING INDEX

GENERAL

DG-001 TITLE PAGE

DG-002 LEGEND

POWER

DP-101 DIRTT POWER OVERALL PLAN

DP-301 ELEVATIONS

POWER 500-SERIES

DP-501 JUNCTION BOX COMPONENT DRAWING - CEILING

DP-503 JUNCTION BOX TYPICAL MOUNT DETAIL - CEILING

DP-505 MODULAR POWER PARTS AND PIECES

DP-506 WALL BOX DETAILS - STANDARD OUTLETS

DP-508 JUNCTION BOX TYPICAL DETAILS - CEILING

This drawing represents DIRTT Environmental Solution Ltd.'s ("DIRTT") interpretation of the design intent and serves as DIRTT's shop drawings for manufacturing purposes. The details and scope of these shop drawings represent the product that will be produced by DIRTT and delivered to site. Any additions or changes to, or deletions or deviations from, these drawings will be regarded as a change order and processed accordingly. Manufacturing will not commence without approval of these shop drawings.

You agree to immediately notify DIRTT of any discrepancies between the on-site dimensions and ceiling heights and those contained in the approved drawings. Upon notification, DIRTT shall take all reasonable steps to make the necessary changes, but shall not be responsible for any additional costs or schedule delays associated with such changes.

You agree to provide a sample of all contractor-supplied hardware to DIRTT within one week of approval of shop drawings. Wherever possible, actual samples of hardware are to be provided to DIRTT.

DIRTT shall not be responsible for any additional costs or schedule delays associated with changes in hardware specifications.

THESE DRAWINGS ARE THE CONFIDENTIAL AND

PROPRIETARY INFORMATION OF DIRTT ENVIRONMENTAL

SOLUTIONS LTD. ANY REPRODUCTION, ALTERATION,

DISCLOSURE OR USE OF THIS DRAWING OTHER THAN AS

AGREED TO BY DIRTT ENVIRONMENTAL SOLUTIONS LTD. IS

EXPRESSLY PROHIBITED.

DISCLAIMER

0 29 Nov 22 DRAWN

CLIENT APPROVAL

APPROVED DRAWING PACKAGE

APPROVED, AS NOTED

REVISED, RESUBMIT

Authorized Signing Officer Date

This drawing represents DIRTT Environmental Solutions (DIRTT)'s interpretation of the design intent and severs as our shop drawings for manufacturing purposes. The details and scope in these drawings represent the product that will be produced by DIRTT and delivered to site. All additions, changes, or deviations from this approval drawing package will be regarded as a change order and processed accordingly. Approval of this drawing package is one of the conditions precedent to commencement of manufacturing.

DIRTT Environmental Solutions

Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D

IR

TT

E nv iro nm en ta l S ol ut io ns L td

DI

RT

T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y

DI

RT

T is ex pr es sly p ro hi bi te d.

D o no t u se d ra w in gs fo r s ca le p ur po se s.

A ll sit e di m en sio ns , d ra w in gs

, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to

D

IR

TT

in w rit in g be fo re p ro ce ed in g w ith w or k.

S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\___F_SIGNED off JOB\VA Brockton Mental Health Off 21Nov SATInstall R0.dwg 2022-11-29 3:07:42 PM

Project:

Drawn by:

Scale:

Date: 2022/11/29

DG-001

T.LUN

Project Address:

Project Name:

VA BROCKTON

MENTAL HEALTH OFF

Project Manager:

PM Phone #:

Date Revision Initial

FINAL

Rev

AS NOTED

TITLE PAGE

DG-001

KEY PLAN1

Scale: 1/16" = 1'-0" / 1:191.999997

PROJECT

AREA

VA BROCKTON - MENTAL HEALTH OFF

DIRTT POWER SHOP DRAWINGS

THIS DOCUMENT CONTAINS CONFIDENTIAL AND OR LEGALLY PRIVILEGED INFORMATION

INTENDED FOR A SPECIFIC PURPOSE AND IS PROTECTED BY LAW. ANY UNAUTHORIZED

DISCLOSURE, COPYING, OR DISTRIBUTING OF THIS MATERIAL IS STRICTLY PROHIBITED.

Project North True North

0 29 Nov 22 DRAWN

Electrical Assembly Schedule Tag SKU Abbreviated Description MFT1 FW10-38W Female Whip (8 Wire) (10 feet)

MFT2 FW09-38W Female Whip (8 Wire) (9 feet)

MFT3 FW11-38W Female Whip (8 Wire) (11 feet)

MFT37 FW08-38W Female Whip (8 Wire) (8 feet)

WB1 WSCS13R22B111FTF8WSS

1 Gang Wall Box (Top Fed Wiring,1 Gang Standard Narrow Stainless Steel Trim,Standard 20 amp receptacle,White,Female Whip (8 wire) 332,11 feet)

WB2 WSCS23R22B1R22B111FTF8WSS

2 Gang Wall Box (Top Fed Wiring,2 Gang Standard Narrow Stainless Steel Trim,Standard 20 amp receptacle,White,Female Whip (8 wire) 332,11 feet)

WB3 WSCS13R22A111FTF8WSS

1 Gang Wall Box (Top Fed Wiring,1 Gang Standard Narrow Stainless Steel Trim,Standard 20 amp receptacle,White,Female Whip (8 wire) 332,11 feet)

WB4 WSCS23R22A1R22A111FTF8WSS

2 Gang Wall Box (Top Fed Wiring,2 Gang Standard Narrow Stainless Steel Trim,Standard 20 amp receptacle,White,Female Whip (8 wire) 332,11 feet)

RED

BLACK

RED

BLACK

RED

BLACK

Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D

IR

TT

E nv iro nm en ta l S ol ut io ns L td

DI

RT

T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y

DI

RT

T is ex pr es sly p ro hi bi te d.

D o no t u se d ra w in gs fo r s ca le p ur po se s.

A ll sit e di m en sio ns , d ra w in gs

, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to

D

IR

TT

in w rit in g be fo re p ro ce ed in g w ith w or k.

S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\___F_SIGNED off JOB\VA Brockton Mental Health Off 21Nov SATInstall R0.dwg 2022-11-29 3:07:45 PM

Project:

Drawn by:

Scale:

Date: 2022/11/29

DG-002

T.LUN

Project Address:

Project Name:

VA BROCKTON

MENTAL HEALTH OFF

Project Manager:

PM Phone #:

Date Revision Initial

FINAL

Rev

AS NOTED

LEGEND

ELECTRICAL LEGEND

F

CP

RAISED FLOOR LEGEND

DIRTT POWER ACCESS FLOOR BOX

ZB01

FLOOR POWER DISTRIBUTION BOX w/

ZONE BOX NUMBER AFTER INSTALLED

LOW PROFILE CONSOLIDATION POINT

X - Floor Level XX - CP Number

RAISE FLOOR - TILES 24" x 24"

XX

XX

XX

Y

XX

Y Y Y

X

XX

CP X-XX

GENERAL NOTES

WALL LEGEND

WALL BOX ID (ELEVATION ONLY) WHERE...

XX - ACTUAL WALL BOX LOCATION FROM

ELEVATION 'XX' OR 'X'

# - BOX NUMBER IDENTIFIER

WB??

WALL BOX ID (PLAN ONLY) WHERE...

?? - WALL BOX TAG #,

REFER TO ELECTRICAL ASSEMBLY SCHEDULE

EXPRESS LINE CABLE 332

(?? - CABLE TAG, SEE KEYNOTE P1)

EXTENDER CABLE 332

(?? - CABLE TAG, SEE KEYNOTE P1)

EXPRESS LINE CABLE 422

(?? - CABLE TAG, SEE KEYNOTE P1)

EXTENDER CABLE 422

(?? - CABLE TAG, SEE KEYNOTE P1)

PATIENT CARE CEILING POWER DISTRIBUTION

BOX

ZB?? - WHERE ?? IS THE ZONE BOX

NUMBER AFTER BEING INSTALLED ON SITE

XXX - CIRCUIT NO. (IN ITALIC)

XXX

NOTES TAG, REFER TO NOTES TABLE FOR

COMMENTS

? - ITEM NUMBER

? DIRTT POWER ROUND ACCESS FLOOR BOX

REFER TO ELECTRICAL SCHEDULE

DIRTT POWER ACCESS FLOOR BOX

REFER TO ELECTRICAL SCHEDULE

PANEL MANAGER

REFER TO DIRTT POWER ELECTRICAL

ASSEMBLY SCHEDULE FOR MORE INFO

FEMALE TO MALE POWER EXTENDER

CONNECTION EITHER IN CEILING OR IN FLOOR

- NO SPLITTER REQUIRED

WHERE ? : C = CEILING OR F = FLOOR

C

XXX XXX - CIRCUIT NO. (IN ITALIC)

HCZB??

FB

FB

POWER CHASSIS - INSTALL ARRANGEMENT

EITHER MOUNTED HORIZONTALLY OR

VERTICALLY TO A SUPPORTING STRUCTURE

BY OTHERS U.N.O.

EXTENDER CABLE 332 - 8 OR 4 WIRES

PATIENT CARE GRADE

(?? - CABLE TAG, SEE KEYNOTE P1)

FEMALE TO MALE POWER EXTENDER

CONNECTION IN INSIDE OF WALL SYSTEM -

NO SPLITTER REQUIRED

CEILING POWER DISTRIBUTION BOX

ZB?? - WHERE ?? IS THE ZONE BOX

NUMBER AFTER BEING INSTALLED ON SITE

XXX - CIRCUIT NO. (IN ITALIC)

XXX C

ZB??

FLOOR POWER DISTRIBUTION BOX

ZB?? - WHERE ?? IS THE ZONE BOX

NUMBER AFTER BEING INSTALLED ON SITE

XXX - CIRCUIT NO. (IN ITALIC)

XXX

ZB??

PATIENT CARE SPLITTER

CEILING MOUNTED

PATIENT CARE SPLITTER

INSIDE WALL MOUNTED

C

EXISTING PANEL MANAGER

- Designates Controlled Receptacle, see Controlled Receptacle legend for info.*

F

4 / 6 OUTLET POWER STRIP

INSTALL ARRANGEMENT EITHER MOUNTED

HORIZONTALLY OR VERTICALLY

EXTENDER CABLE 422

HORIZONTALLY WIRED IN DIRTT WALL

(?? - CABLE TAG, SEE KEYNOTE P1)

EXTENDER CABLE 332

HORIZONTALLY WIRED IN DIRTT WALL

(?? - CABLE TAG, SEE KEYNOTE P1)

SPLITTER

All splitters are in the ceiling unless otherwise specified W = Wall F = Floor E = Existing

DIRTT POWER MODULAR WHIP

?? : Whip TAG, See Electrical Schedule

XXX - CIRCUIT NO. (IN ITALIC)

All whips are in the ceiling unless otherwise specified ? : W = Wall OR F = Floor

XXX

MFT??

DIRTT POWER MODULAR WHIP

MALE TO FEMALE CONNECTION

?? : Whip TAG, See Electrical Schedule

XXX - CIRCUIT NO. (IN ITALIC)

All whips are in the ceiling unless otherwise specified ? : W = Wall OR F = Floor

XXX

MFT??

JUNCTION BOX WITH

DIRTT POWER MODULAR WHIP

XXX - CIRCUIT NO. (IN ITALIC)

All modular junction boxes are in the ceiling unless otherwise specified ?? : W = Wall OR F = Floor

XXX

JB

XXX

JB

JUNCTION BOX WITH

TWO DIRTT POWER MODULAR WHIPS

XXX - CIRCUIT NO. (IN ITALIC)

All modular junction boxes are in the ceiling unless otherwise specified ?? : W = Wall OR F = Floor

DIRTT WALL WITH CLERESTORY

DIRTT GLASSWALL WITH DOOR

DRYWALL

DIRTT POWER ACCESS MINI LOW PROFILE

FLOOR BOX

CAT# AFB202 (? - DEVICE OR DEVICES IN BOX)

FB ? ?

Cable Type E=Extender EL=Express line EHC=Patient care extender

P1: LABELING KEYNOTE

E 05 - 3 8W

Length (ft)

Wire Fill

3A = BLACK WIRE

3B = RED WIRE

3C = BLUE WIRE

4W = 4 wire 5W = 5 wire 8W = 8 wire *see wiring schematic

Wiring Configuration 3 = 332 independent neutral 4 = 422 shared neutral *see wiring shcematic

A. INSTALLATION STANDARDS: CABLE AND EQUIPMENT INSTALLATION COMPLY WITH THE

FOLLOWING STANDARDS:

2. CANADIAN ELECTRICAL CODE, 2018 (OR AS OBSERVED BY LOCAL)

REFERENCE CODES AND STANDARDS

1. NATIONAL ELECTRICAL CODE, 2018 (OR AS OBSERVED BY LOCAL)

DIRTT UL LISTING REPORTS

UL183 File Manufactured Wiring systems FILE # - E210896

UL514A File Metallic Outlet Box FILE # - E212646 QQYZ Wiring Assemblies FILE # - E328144

QQXX Sections and Units FILE # - E468975

UL507 Fans FILE # - E496838

UL KEZR Prefabricated Medical Headwalls FILE # - E499706

UL STANDARDS

UL 183 Standard for Safety for Manufactured Wiring Systems

UL 514A Standard for Safety for Metallic Outlet Boxes

UL 514C Standard for Nonmetallic Boxes and Covers UL 514D Standard for Cover Plates for Flush-Mounted Wiring Devices

UL QQXX Sections and Units ANSI/NFPA 70, “National Electrical Code” (NEC), 2008 Edition

ANSI/UL Standard 1286 - Office Furnishings

DIRTT CSA LISTING REPORTS

2117966 Class 6242 05/Class 6242 85 Power Harnesses, Power/conduit Whips, Power Extenders and Pre-wired Distribution Box & Junction Box Assemblies (level 3 & 4)

2563936 Class 4411 01/4411 81 Outlet Boxes and Fittings - Boxes

1514152 Class 4413 02/4413 82 Outlet Box and Fittings - Plates and cover Plates

1014788 Class 4612 01/4612 81 Boxes Miscellaneous

1039557 Class 6242 03/6242 83 Wiring Systems and Accessories - Modular

CSA STANDARDS

CAN/CSA C22.2 No. 0 General Requirements - Canadian Electrical Code Part CSA Standard C22.2 No. 203.1-94 - Manufactured Wiring Products

CAN/CSA Standard C22.2 No. 18.1-04 Metallic Outlet Boxes

CSA Standard C22.2 No. 42-1999 General Use Receptacles, Attachment Plugs and Similar Wiring Devices CSA Standard

C22.2 No. 42.1-2000 Cover Plates for Flush Mounted Wiring Devices

CSA Standard C22.2 No 203-M91 Modular Wiring Systems for Office Furniture

CSA C22.2 No. 0.4-04 Bonding and Bonding of Electrical Equipment (Protective Bonding)

3-3-2 SYSTEM 8 WIRE CONFIGURATION SCHEMATIC

8 WIRE CONFIGURATION

1. ALL FIRE RATED PLYWOOD BACK BOARDS ARE FURNISHED INSTALLED AND PAINTED BY OTHERS.

2. ALL CONDUIT PATHWAYS, BACK BOXES, CONDUIT PENETRATIONS AND SLEEVES OUTSIDE OF DIRTT WALLS ARE FURNISHED AND

INSTALLED BY OTHERS.

3. ALL HOUSE/BUILDING GROUND WIRING ARE TO BE FURNISHED AND INSTALLED BY OTHERS.

4. ALL ELECTRICAL ROUTING PATHS ARE FOR REPRESENTATION ONLY, THE ACTUAL ROUTING TO BE DETERMINED ON SITE BY OTHERS

5. ALL NETWORKING ROUTING PATH SHOWN IN OUR INSTALL DRAWING IS FOR CLARIFICATION PURPOSES ONLY. THE ROUTE TAKE DOES

NOT REPRESENT THE ACTUAL PATH TO BE USED FOR INSTALL

6. ALL COMPONENTS IN PLAN ARE CEILING/WALL COMPONENTS

AutoCAD SHX Text

XX#

AutoCAD SHX Text

AutoCAD SHX Text

SHC3

AutoCAD SHX Text

SCH3

AutoCAD SHX Text

SCH3

AutoCAD SHX Text

SCH3

AutoCAD SHX Text

BLUE

AutoCAD SHX Text

GREEN/YELLOW

AutoCAD SHX Text

WHITE/RED

AutoCAD SHX Text

WHITE/BLACK

AutoCAD SHX Text

BARE

AutoCAD SHX Text

BLACK

AutoCAD SHX Text

RED

AutoCAD SHX Text

L1 N1 G1 CIRCUIT "A"

AutoCAD SHX Text

L2 N2 G1 CIRCUIT "B"

AutoCAD SHX Text

L3 N3 IG CIRCUIT "C"

AutoCAD SHX Text L3

AutoCAD SHX Text L2

AutoCAD SHX Text L1

AutoCAD SHX Text CONNECTIONS TO A GROUNDED THREE-PHASE SYSTEM RATING: 120/208V, 3 PHASE WYE 60HZ, 20 AMP, WHITE RATED AT 20 AMP MULTIWIRE BRANCH CIRCUIT

AutoCAD SHX Text

RECPTACLE CONNECTIONS (LOAD)

AutoCAD SHX Text

WHITE/BLUE

GROUP

ROOM

A-404A

CONSULT

ROOM

B-401A

MULTI-PURPOSE

ROOM

B-429

CONSULT

ROOM

B-430

CONSULT

ROOM

B-431

CONSULT

ROOM

B-401B

CONSULT

ROOM

B-428

CLOSET

B-426

MEN'S

RESTROOM

B-425

WOMEN'S

RESTROOM

B-424

CONSULT

ROOM

B-422D

CONSULT

ROOM

B-422?

CONSULT

ROOM

B-422?

CONSULT

ROOM

B-422A

CONSULT

ROOM

B-421A

CONSULT

ROOM

B-420A

CONSULT

ROOM

B-416

CONSULT

ROOM

B-405

CONSULT

ROOM

B-406

CONSULT

ROOM

B-407

CONSULT

ROOM

B-408

CONSULT

ROOM

B-409

CONSULT

ROOM

B-410

CONSULT

ROOM

B-411

CONSULT

ROOM

B-412

CONSULT

ROOM

B-413

CONSULT

ROOM

B-414

CONSULT

ROOM

B-415

CORRIDOR

CRB402

B-412A B-409A

B-407AB-414A

B-406AB-415A

B-405AB-416A

B-417

B-418

B-418A

B-419

B-404

B-403

EMS

CLOSET

B-402

CORRIDOR

CRB401

ST2B401

FCB401

WHOLE

HEALTH

OFFICE

A-405

CONSULT

ROOM

B-420B

CONSULT

ROOM

B-421B

TEL/DATA

B-428A

CONSULT

ROOM

B-422B

CONSULT

ROOM

B-422?

C1C1

C2

C

C

C2

F1 F1

F1

F4

BH

F1

HD

BH

F1

F5F5

F4

BH

F2

HD

BH

F2

C2

C1C1

C

C

C2

F1

F7

BH

F1

HD

BH

F1

F4

F8 F8

BH

F2

HD

BH

F2

F9

C2

C1C1

C

C

C2

C

C

C2 C2

C1C1

C

C

C2

C1C1C1C1

C2C2 C2

C

C

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F4

BH

F1

HD

BH

F1

F2

BH

F2

HD

BH

F2

C

F21F21

F4

BH

F2

HD

BH

F2

F4

BH

F1

HD

BH

F1

F22F22

F4

BH

F2

HD

BH

F2

F23 F24

BHF1

HD

BHF1

F4

BHF2

HD

BHF2

F25

F26F26

F2

BH

F1

HD

BH

F1

L2 S

G

L2S G

L2S G

L2 S

G

L2 S

G

L2S G

L2 S

G

L2S G

L2 S

G

L2S G

L2 S

G

L2S G

E05-38W

E05-38W

MFT2

MFT37 MFT1 MFT1 MFT1MFT3

WB1

WB2

WB3

WB4

WB2

WB4

WB3

WB1

WB1

WB2

WB3

WB4

WB1

WB2

WB3

WB4

WB1

WB2

WB3

WB4

WB3

WB4

WB2

WB1

2 Circuits Phased A,B

2 Circuits Phased A,B

2 Circuits Phased A,B

2 Circuits Phased A,B

2 Circuits Phased A,B

E05-38WE05-38WE05-38W E05-38W

A S

A T

KL

A K

A L

A E

A F

WXIJ

0 29 Nov 22 DRAWN

Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D

IR

TT

E nv iro nm en ta l S ol ut io ns L td

DI

RT

T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y

DI

RT

T is ex pr es sly p ro hi bi te d.

D o no t u se d ra w in gs fo r s ca le p ur po se s.

A ll sit e di m en sio ns , d ra w in gs

, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to

D

IR

TT

in w rit in g be fo re p ro ce ed in g w ith w or k.

S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\___F_SIGNED off JOB\VA Brockton Mental Health Off 21Nov SATInstall R0.dwg 2022-11-29 3:07:52 PM

Project:

Drawn by:

Scale:

Date: 2022/11/29

DP-101

T.LUN

Project Address:

Project Name:

VA BROCKTON

MENTAL HEALTH OFF

Project Manager:

PM Phone #:

Date Revision Initial

FINAL

Rev

AS NOTED

DIRTT POWER

OVERALL PLAN

DP-101

FLOOR PLAN1

1/4" = 1'-0" / 1:48

F1 F1290F1292 F1F1292F1290

BHF1

HD1

BHF1

F4

BHF1

HD1

BHF1

F4F5F5 F5F5F4

BHF2

HD2

BHF2

F4

BHF2

HD2

BHF2

F1289 F7 F7 F1289

BHF1

HD1

BHF1

F4

BHF1

HD1

BHF1

F4

F8F8 F8 F8

BHF2

HD2

BHF2

F9 F9

BHF2

HD2

BHF2

F10 F12F11 F10F12 F11F14 F15F13 F15 F14 F13

F17F16 F16F17

F1285 F1288 F1285F1288

BHF1

HD1

BHF1

F4 F4

BHF1

HD1

BHF1

BHF2

HD2

BHF2

F20 C35 C35 F20

BHF2

HD2

BHF2

F21 F21 F21 F21

F4

BHF2

HD2

BHF2

BHF2

HD2

BHF2

F4 F4

BHF1

HD1

BHF1

F4

BHF1

HD1

BHF1

F22 F22 F22 F22

BHF2

HD2

BHF2

F4 F4

BHF2

HD2

BHF2

F23 F24 F24 F23

BHF1

HD1

BHF1

F4 F4

BHF1

HD1

BHF1

F25

BHF2

HD2

BHF2

BHF2

HD2

BHF2

F25 F26 F26 F26 F26

BHF1

HD1

BHF1

F27 F27

BHF1

HD1

BHF1

Elevation AS Elevation AT Elevation AU Elevation AVElevation AQ Elevation ARElevation AO Elevation AP

Elevation K Elevation L

Elevation G Elevation H

Elevation M Elevation N Elevation O Elevation P

Elevation AK Elevation ALElevation AE Elevation AF

Elevation W Elevation X

Elevation I Elevation J

Elevation AM Elevation AN

Elevation AG Elevation AH Elevation AI Elevation AJ

Elevation Y Elevation Z Elevation AC Elevation ADElevation AA Elevation AB

Elevation Q Elevation R Elevation S Elevation T

Elevation C Elevation DElevation A Elevation B Elevation E Elevation F

Elevation U Elevation V

Side A Side B Side A Side BSide A Side BSide A Side B

Side A Side B

Side A Side B

Side A Side B Side A Side B

Side A Side BSide A Side B

Side A Side B

Side A Side B

Side A Side B

Side A Side B Side A Side B

Side A Side B Side A Side BSide A Side B

Side A Side B Side A Side B

Side A Side BSide A Side B Side A Side B

Side A Side B

0 29 Nov 22 DRAWN

Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D

IR

TT

E nv iro nm en ta l S ol ut io ns L td

DI

RT

T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y

DI

RT

T is ex pr es sly p ro hi bi te d.

D o no t u se d ra w in gs fo r s ca le p ur po se s.

A ll sit e di m en sio ns , d ra w in gs

, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to

D

IR

TT

in w rit in g be fo re p ro ce ed in g w ith w or k.

S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\___F_SIGNED off JOB\VA Brockton Mental Health Off 21Nov SATInstall R0.dwg 2022-11-29 3:07:55 PM

Project:

Drawn by:

Scale:

Date: 2022/11/29

DP-301

T.LUN

Project Address:

Project Name:

VA BROCKTON

MENTAL HEALTH OFF

Project Manager:

PM Phone #:

Date Revision Initial

FINAL

Rev

AS NOTED

ELEVATION VIEWS

DP-301

ELEVATION VIEWS1

3/8" = 1'-0" / 1:32

DEVICES (WALL BOX)ELECTRICAL PANEL

EMT CONDUIT

THRU DRYWALL

WALL CLAMP

ELECTRICAL

PANEL

(BY OTHERS)

DIRTT POWER WHIP SPLITTER

WALL BOX WHIP

WALL BOX WHIP

EXTENDER

HOMERUN CONDUIT FROM

ELECTRICAL PANEL

POWER WHIP SPLITTER

EXTENDER WALL BOX WHIP

CONTRACTOR SUPPLIED &

INSTALLED

EXTENDER

DIRTT POWER COMPONENT DRAWING

CEILING

DIRTT SUPPLIED, SEE SCOPE OF

WORK DOCUMENT

HOMERUN CONDUIT FROM

ELECTRICAL PANEL

JUNCTION BOX

Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D

IR

TT

E nv iro nm en ta l S ol ut io ns L td

DI

RT

T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y

DI

RT

T is ex pr es sly p ro hi bi te d.

D o no t u se d ra w in gs fo r s ca le p ur po se s.

A ll sit e di m en sio ns , d ra w in gs

, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to

D

IR

TT

in w rit in g be fo re p ro ce ed in g w ith w or k.

S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg 2021-9-27 1:22:56 PM

Project:

Drawn by:

Scale:

Date: 2021/09/27

DP-502

Project Address:

Project Name:

DIRTT POWER 500 SERIES

Project Manager:

PM Phone #:

Date Revision Initial

Rev

AS NOTED

POWER WHIP COMPONENT

DRAWING - CEILING

DP-502

POWER WHIP COMPONENT DRAWING - CEILING1

1/4" = 1'-0" / 1:48.0008

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg, 9/27/2021 1:22:56 PM, DWG To PDF.pc3

TYPICAL POWER WHIP MOUNTING DETAIL

ABOVE DROP CEILING

CEILING TILE

THREAD ROD *

CONCRETE SLAB

UNISTRUT *

JUNCTION BOX PROVIDED BY

OTHERS

PIGTAIL WHIP PROVIDED BY DIRTT

CIEILING CONCRETE SLAB

TYPICAL POWER WHIP MOUNTING DETAIL

DECK MOUNTED

JUNCTION BOX (JB)

SCREWED TO SLAB *

JUNCTION BOX PROVIDED BY

OTHERS

PIGTAIL WHIP PROVIDED BY DIRTT

* MOUNTING HARDWARE AND

SUPPORT IS PROVIDED BY

OTHERS

CONCRETE SLAB

CONCRETE SLAB

THREAD ROD *

J-HOOKS *

TYPICAL SPLITTER MOUNTING DETAIL

ABOVE DROP CEILING WITH J-HOOKS

ELECTRICAL CLIP

SECURED TO DECK*

TYPICAL SPLITTER MOUNTING DETAIL

ABOVE DROP CEILING WITH CLIPS

CEILING TILE

Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D

IR

TT

E nv iro nm en ta l S ol ut io ns L td

DI

RT

T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y

DI

RT

T is ex pr es sly p ro hi bi te d.

D o no t u se d ra w in gs fo r s ca le p ur po se s.

A ll sit e di m en sio ns , d ra w in gs

, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to

D

IR

TT

in w rit in g be fo re p ro ce ed in g w ith w or k.

S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg 2021-9-27 1:22:58 PM

Project:

Drawn by:

Scale:

Date: 2021/09/27

DP-504

Project Address:

Project Name:

DIRTT POWER 500 SERIES

Project Manager:

PM Phone #:

Date Revision Initial

Rev

AS NOTED

POWER WHIP TYPICAL

MOUNT DETAIL - CEILING

DP-504

POWER WHIP TYPICAL MOUNT DETAIL - CEILING1

1/4" = 1'-0" / 1:48.0022

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg, 9/27/2021 1:22:58 PM, DWG To PDF.pc3

EXTENDER (3/3/2 OR 4/2/2)

SPLITTER (3/3/2 OR 4/2/2)

PIGTAIL MODULAR POWER WHIP (3/3/2 OR 4/2/2)

1 WHIP MODULAR JUNCTION BOX (3/3/2 OR 4/2/2)

2 WHIP MODULAR JUNCTION BOX

CONTROLLED CIRCUIT APPLICATIONS (3/3/2 OR 4/2/2)

4 OR 6 OUTLET POWER STRIP (3/3/2 OR 4/2/2)

3 GANG POWER CHASSIS (3/3/2 OR 4/2/2)

BLANK FACEPLATE

DATA/AV OPTIONS

-- N

OT USED ---

-- N

OT USED ---

Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D

IR

TT

E nv iro nm en ta l S ol ut io ns L td

DI

RT

T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y

DI

RT

T is ex pr es sly p ro hi bi te d.

D o no t u se d ra w in gs fo r s ca le p ur po se s.

A ll sit e di m en sio ns , d ra w in gs

, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to

D

IR

TT

in w rit in g be fo re p ro ce ed in g w ith w or k.

S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg 2021-9-27 1:23:00 PM

Project:

Drawn by:

Scale:

Date: 2021/09/27

DP-505

Project Address:

Project Name:

DIRTT POWER 500 SERIES

Project Manager:

PM Phone #:

Date Revision Initial

Rev

AS NOTED

MODULAR POWER

PARTS AND PIECES

DP-505

MODULAR POWER PARTS AND PIECES1

1/4" = 1'-0" / 1:48.0009

Project North True North

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg, 9/27/2021 1:22:59 PM, DWG To PDF.pc3

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

SCALE: NTS

-- N

OT USED ---

2" X 4.50" X 2.25" DEEP

OUTLET BOX (BY DIRTT)

WB##

4" X 4" X 2.25" DEEP

OUTLET BOX (BY DIRTT)

4" X 4.50" OUTLET COVER

PLATE (BY DIRTT)

WB##

BLANK COVER PLATE

CAN BE DATA

6" X 4.50" OUTLET COVER

PLATE (BY DIRTT)

6" X 4" X 2.25" DEEP

OUTLET BOX (BY DIRTT)

BLANK COVER PLATE

CAN BE POWER/DATA

WB##

WB##

8" X 4" X 2.25" DEEP

OUTLET BOX (BY DIRTT)

8" X 4.50" OUTLET COVER

PLATE (BY DIRTT)

BLANK COVER PLATE

CAN BE DATA

WB##

BLANK COVER PLATE

CAN BE DATA

TYPICAL 1 GANG MODULAR POWER WALL BOX

WITH STANDARD OUTLET (15A OR 20A)

TYPICAL 2 GANG MODULAR POWER WALL BOX

WITH STANDARD OUTLET (15A OR 20A)

TYPICAL 3 GANG MODULAR POWER WALL BOX

WITH STANDARD OUTLET (15A OR 20A)

TYPICAL 4 GANG MODULAR POWER WALL BOX

WITH STANDARD OUTLET (15A OR 20A)

TYPICAL 6 GANG MODULAR POWER WALL BOX

WITH STANDARD OUTLET (15A OR 20A)

5 XXX x

Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D

IR

TT

E nv iro nm en ta l S ol ut io ns L td

DI

RT

T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y

DI

RT

T is ex pr es sly p ro hi bi te d.

D o no t u se d ra w in gs fo r s ca le p ur po se s.

A ll sit e di m en sio ns , d ra w in gs

, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to

D

IR

TT

in w rit in g be fo re p ro ce ed in g w ith w or k.

S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg 2021-9-27 1:23:03 PM

Project:

Drawn by:

Scale:

Date: 2021/09/27

DP-506

Project Address:

Project Name:

DIRTT POWER 500 SERIES

Project Manager:

PM Phone #:

Date Revision Initial

Rev

AS NOTED

WALL BOX DETAILS

STANDARD OUTLETS

DP-506

WALL BOX DETAILS - STANDARD OUTLETS1

CUSTOM / 1:48.0024

Project North True North

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg, 9/27/2021 1:23:02 PM, DWG To PDF.pc3

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

EXTENDER CABLE RUN HORIZONTALTHRU

EXTRUSION CUTOUT

WALL BOX

WALL MOUNTED SPLITTER

WALL BOX WHIP

EXTENDER

CEILING MOUNTED

SPLITTER

EXTENDER

POWER WHIP

DIRTT WALL PANELS

NOT SHOWN

WALL BOX

WALL BOX WHIP

EXTENDER

CEILING MOUNTED

SPLITTER

EXTENDER

DIRTT WALL PANELS

NOT SHOWN

CEILING MOUNTED

SPLITTER

EXTENDER

DIRTT WALL PANELS

NOT SHOWN

POWER STRIP WHIP

EXTENDER

POWER STRIP

CEILING MOUNTED

SPLITTER

EXTENDER

DIRTT WALL PANELS

NOT SHOWN

EXTENDER

POWER CHASSIS

POWER WHIP

POWER WHIP

POWER WHIP

TYPICAL POWER WHIP CEILING DISTRIBUTION

WITH CLERESTORY WALLS - HORIZONTAL WIRING

TYPICAL POWER WHIP CEILING DISTRIBUTION

WITH SOLID WALLS SPLITERS IN CEILING

TYPICAL POWER WHIP CEILING DISTRIBUTION

WITH POWER CHASSIS (IF APPLICABLE)

TYPICAL POWER WHIP CEILING DISTRIBUTION

WITH POWER STRIP (IF APPLICABLE)

TYPICAL POWER WHIP CEILING DISTRIBUTION

WITH 2 WHIP JUNCTION FOR PLUG LOAD CONTROLLER WIRING

WALL BOX WHIP

EXTENDER

CEILING MOUNTED

SPLITTER

EXTENDER

POWER WHIP

DIRTT WALL PANELS

NOT SHOWN

CEILING MOUNTED

2 WHIP JUNCTION BOX

WALL BOX

PLUG LOAD CONTROLLER

(GC SCOPE)

PLUG LOAD CONTROLLER

WIRING (GC SCOPE)

EXTENDER CABLE RUN HORIZONTALTHRU

EXTRUSION CUTOUT

WALL BOX

WALL MOUNTED SPLITTER

WALL BOX WHIP

EXTENDER

IN-WALL MOUNTED

POWER WHIP

DIRTT WALL PANELS

NOT SHOWN

TYPICAL POWER WHIP MOUNTED IN WALL

WITH CLERESTORY WALLS - HORIZONTAL WIRING

Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D

IR

TT

E nv iro nm en ta l S ol ut io ns L td

DI

RT

T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y

DI

RT

T is ex pr es sly p ro hi bi te d.

D o no t u se d ra w in gs fo r s ca le p ur po se s.

A ll sit e di m en sio ns , d ra w in gs

, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to

D

IR

TT

in w rit in g be fo re p ro ce ed in g w ith w or k.

S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg 2021-9-27 1:23:06 PM

Project:

Drawn by:

Scale:

Date: 2021/09/27

DP-509

Project Address:

Project Name:

DIRTT POWER 500 SERIES

Project Manager:

PM Phone #:

Date Revision Initial

Rev

AS NOTED

POWER WHIP TYPICAL

DETAILS - CEILING

DP-509

POWER WHIP TYPICAL DETAILS - CEILING1

1/4" = 1'-0" / 1:47.998

Project North True North

C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg, 9/27/2021 1:23:05 PM, DWG To PDF.pc3

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

SCALE: NTS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VA Brockton Mental Health Off 21Nov SATInstall R0
Sheets and Views
VA Brockton Mental Health Off 21Nov SATInstall R0-DG-001
VA Brockton Mental Health Off 21Nov SATInstall R0-DG-002
VA Brockton Mental Health Off 21Nov SATInstall R0-DP-101
VA Brockton Mental Health Off 21Nov SATInstall R0-DP-301
VA Brockton Mental Health Off - DNP Power TZ500 - PW R0
Sheets and Views
DNP Power TZ500 - PW R0 - Std-DP-502
DNP Power TZ500 - PW R0 - Std-DP-504
DNP Power TZ500 - PW R0 - Std-DP-505
DNP Power TZ500 - PW R0 - Std-DP-506
DNP Power TZ500 - PW R0 - Std-DP-509

File details come from the government source that posted it. Updated .