P01-3. VA Brockton Mental Health Off 21Nov SATInstall R0 (1).pdf
PDF 9 MB Posted
- Attached to
- 7110-- Amendment 1 to extend the Due date to 31 March 2023-Demountable Wall System Federal contract opportunity
- Solicitation number
- 36C24123Q0460
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24123Q0460 0001.docx | DOCX document | |
| P07-WD WAGE DET DEMOUNTABLE WALL.pdf | ||
| P01 1. VABHS Brockton Bldg 3 SOW Modular Walls MH Service.pdf | ||
| P01-2. Outpatient MH Services Layout 3 Phase 2.pdf | ||
| 36C24123Q0460.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GROUP
ROOM
A-404A
CONSULT
ROOM
B-401A
MULTI-PURPOSE
ROOM
B-429
CONSULT
ROOM
B-430
CONSULT
ROOM
B-431
CONSULT
ROOM
B-401B
CONSULT
ROOM
B-428
CLOSET
B-426
MEN'S
RESTROOM
B-425
WOMEN'S
RESTROOM
B-424
CONSULT
ROOM
B-422D
CONSULT
ROOM
B-422?
CONSULT
ROOM
B-422?
CONSULT
ROOM
B-422A
CONSULT
ROOM
B-421A
CONSULT
ROOM
B-420A
CONSULT
ROOM
B-416
CONSULT
ROOM
B-405
CONSULT
ROOM
B-406
CONSULT
ROOM
B-407
CONSULT
ROOM
B-408
CONSULT
ROOM
B-409
CONSULT
ROOM
B-410
CONSULT
ROOM
B-411
CONSULT
ROOM
B-412
CONSULT
ROOM
B-413
CONSULT
ROOM
B-414
CONSULT
ROOM
B-415
CORRIDOR
CRB402
B-412A B-409A
B-407AB-414A
B-406AB-415A
B-405AB-416A
B-417
B-418
B-418A
B-419
B-404
B-403
EMS
CLOSET
B-402
CORRIDOR
CRB401
ST2B401
FCB401
WHOLE
HEALTH
OFFICE
A-405
CONSULT
ROOM
B-420B
CONSULT
ROOM
B-421B
TEL/DATA
B-428A
CONSULT
ROOM
B-422B
CONSULT
ROOM
B-422?
C1C1
C2
C
C
C2
F1 F1
F1
F4
BH
F1
HD
BH
F1
F5F5
F4
BH
F2
HD
BH
F2
C2
C1C1
C
C
C2
F1
F7
BH
F1
HD
BH
F1
F4
F8 F8
BH
F2
HD
BH
F2
F9
C2
C1C1
C
C
C2
C
C
C2 C2
C1C1
C
C
C2
C1C1C1C1
C2C2 C2
C
C
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F4
BH
F1
HD
BH
F1
F2
BH
F2
HD
BH
F2
C
F21F21
F4
BH
F2
HD
BH
F2
F4
BH
F1
HD
BH
F1
F22F22
F4
BH
F2
HD
BH
F2
F23 F24
BHF1
HD
BHF1
F4
BHF2
HD
BHF2
F25
F26F26
F2
BH
F1
HD
BH
F1
L2 S
G
L2S G
L2S G
L2 S
G
L2 S
G
L2S G
L2 S
G
L2S G
L2 S
G
L2S G
L2 S
G
L2S G
DRAWING INDEX
GENERAL
DG-001 TITLE PAGE
DG-002 LEGEND
POWER
DP-101 DIRTT POWER OVERALL PLAN
DP-301 ELEVATIONS
POWER 500-SERIES
DP-501 JUNCTION BOX COMPONENT DRAWING - CEILING
DP-503 JUNCTION BOX TYPICAL MOUNT DETAIL - CEILING
DP-505 MODULAR POWER PARTS AND PIECES
DP-506 WALL BOX DETAILS - STANDARD OUTLETS
DP-508 JUNCTION BOX TYPICAL DETAILS - CEILING
This drawing represents DIRTT Environmental Solution Ltd.'s ("DIRTT") interpretation of the design intent and serves as DIRTT's shop drawings for manufacturing purposes. The details and scope of these shop drawings represent the product that will be produced by DIRTT and delivered to site. Any additions or changes to, or deletions or deviations from, these drawings will be regarded as a change order and processed accordingly. Manufacturing will not commence without approval of these shop drawings.
You agree to immediately notify DIRTT of any discrepancies between the on-site dimensions and ceiling heights and those contained in the approved drawings. Upon notification, DIRTT shall take all reasonable steps to make the necessary changes, but shall not be responsible for any additional costs or schedule delays associated with such changes.
You agree to provide a sample of all contractor-supplied hardware to DIRTT within one week of approval of shop drawings. Wherever possible, actual samples of hardware are to be provided to DIRTT.
DIRTT shall not be responsible for any additional costs or schedule delays associated with changes in hardware specifications.
THESE DRAWINGS ARE THE CONFIDENTIAL AND
PROPRIETARY INFORMATION OF DIRTT ENVIRONMENTAL
SOLUTIONS LTD. ANY REPRODUCTION, ALTERATION,
DISCLOSURE OR USE OF THIS DRAWING OTHER THAN AS
AGREED TO BY DIRTT ENVIRONMENTAL SOLUTIONS LTD. IS
EXPRESSLY PROHIBITED.
DISCLAIMER
0 29 Nov 22 DRAWN
CLIENT APPROVAL
APPROVED DRAWING PACKAGE
APPROVED, AS NOTED
REVISED, RESUBMIT
Authorized Signing Officer Date
This drawing represents DIRTT Environmental Solutions (DIRTT)'s interpretation of the design intent and severs as our shop drawings for manufacturing purposes. The details and scope in these drawings represent the product that will be produced by DIRTT and delivered to site. All additions, changes, or deviations from this approval drawing package will be regarded as a change order and processed accordingly. Approval of this drawing package is one of the conditions precedent to commencement of manufacturing.
DIRTT Environmental Solutions
Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D
IR
TT
E nv iro nm en ta l S ol ut io ns L td
DI
RT
T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y
DI
RT
T is ex pr es sly p ro hi bi te d.
D o no t u se d ra w in gs fo r s ca le p ur po se s.
A ll sit e di m en sio ns , d ra w in gs
, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to
D
IR
TT
in w rit in g be fo re p ro ce ed in g w ith w or k.
S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\___F_SIGNED off JOB\VA Brockton Mental Health Off 21Nov SATInstall R0.dwg 2022-11-29 3:07:42 PM
Project:
Drawn by:
Scale:
Date: 2022/11/29
DG-001
T.LUN
Project Address:
Project Name:
VA BROCKTON
MENTAL HEALTH OFF
Project Manager:
PM Phone #:
Date Revision Initial
FINAL
Rev
AS NOTED
TITLE PAGE
DG-001
KEY PLAN1
Scale: 1/16" = 1'-0" / 1:191.999997
PROJECT
AREA
VA BROCKTON - MENTAL HEALTH OFF
DIRTT POWER SHOP DRAWINGS
THIS DOCUMENT CONTAINS CONFIDENTIAL AND OR LEGALLY PRIVILEGED INFORMATION
INTENDED FOR A SPECIFIC PURPOSE AND IS PROTECTED BY LAW. ANY UNAUTHORIZED
DISCLOSURE, COPYING, OR DISTRIBUTING OF THIS MATERIAL IS STRICTLY PROHIBITED.
Project North True North
0 29 Nov 22 DRAWN
Electrical Assembly Schedule Tag SKU Abbreviated Description MFT1 FW10-38W Female Whip (8 Wire) (10 feet)
MFT2 FW09-38W Female Whip (8 Wire) (9 feet)
MFT3 FW11-38W Female Whip (8 Wire) (11 feet)
MFT37 FW08-38W Female Whip (8 Wire) (8 feet)
WB1 WSCS13R22B111FTF8WSS
1 Gang Wall Box (Top Fed Wiring,1 Gang Standard Narrow Stainless Steel Trim,Standard 20 amp receptacle,White,Female Whip (8 wire) 332,11 feet)
WB2 WSCS23R22B1R22B111FTF8WSS
2 Gang Wall Box (Top Fed Wiring,2 Gang Standard Narrow Stainless Steel Trim,Standard 20 amp receptacle,White,Female Whip (8 wire) 332,11 feet)
WB3 WSCS13R22A111FTF8WSS
1 Gang Wall Box (Top Fed Wiring,1 Gang Standard Narrow Stainless Steel Trim,Standard 20 amp receptacle,White,Female Whip (8 wire) 332,11 feet)
WB4 WSCS23R22A1R22A111FTF8WSS
2 Gang Wall Box (Top Fed Wiring,2 Gang Standard Narrow Stainless Steel Trim,Standard 20 amp receptacle,White,Female Whip (8 wire) 332,11 feet)
RED
BLACK
RED
BLACK
RED
BLACK
Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D
IR
TT
E nv iro nm en ta l S ol ut io ns L td
DI
RT
T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y
DI
RT
T is ex pr es sly p ro hi bi te d.
D o no t u se d ra w in gs fo r s ca le p ur po se s.
A ll sit e di m en sio ns , d ra w in gs
, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to
D
IR
TT
in w rit in g be fo re p ro ce ed in g w ith w or k.
S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\___F_SIGNED off JOB\VA Brockton Mental Health Off 21Nov SATInstall R0.dwg 2022-11-29 3:07:45 PM
Project:
Drawn by:
Scale:
Date: 2022/11/29
DG-002
T.LUN
Project Address:
Project Name:
VA BROCKTON
MENTAL HEALTH OFF
Project Manager:
PM Phone #:
Date Revision Initial
FINAL
Rev
AS NOTED
LEGEND
ELECTRICAL LEGEND
F
CP
RAISED FLOOR LEGEND
DIRTT POWER ACCESS FLOOR BOX
ZB01
FLOOR POWER DISTRIBUTION BOX w/
ZONE BOX NUMBER AFTER INSTALLED
LOW PROFILE CONSOLIDATION POINT
X - Floor Level XX - CP Number
RAISE FLOOR - TILES 24" x 24"
XX
XX
XX
Y
XX
Y Y Y
X
XX
CP X-XX
GENERAL NOTES
WALL LEGEND
WALL BOX ID (ELEVATION ONLY) WHERE...
XX - ACTUAL WALL BOX LOCATION FROM
ELEVATION 'XX' OR 'X'
# - BOX NUMBER IDENTIFIER
WB??
WALL BOX ID (PLAN ONLY) WHERE...
?? - WALL BOX TAG #,
REFER TO ELECTRICAL ASSEMBLY SCHEDULE
EXPRESS LINE CABLE 332
(?? - CABLE TAG, SEE KEYNOTE P1)
EXTENDER CABLE 332
(?? - CABLE TAG, SEE KEYNOTE P1)
EXPRESS LINE CABLE 422
(?? - CABLE TAG, SEE KEYNOTE P1)
EXTENDER CABLE 422
(?? - CABLE TAG, SEE KEYNOTE P1)
PATIENT CARE CEILING POWER DISTRIBUTION
BOX
ZB?? - WHERE ?? IS THE ZONE BOX
NUMBER AFTER BEING INSTALLED ON SITE
XXX - CIRCUIT NO. (IN ITALIC)
XXX
NOTES TAG, REFER TO NOTES TABLE FOR
COMMENTS
? - ITEM NUMBER
? DIRTT POWER ROUND ACCESS FLOOR BOX
REFER TO ELECTRICAL SCHEDULE
DIRTT POWER ACCESS FLOOR BOX
REFER TO ELECTRICAL SCHEDULE
PANEL MANAGER
REFER TO DIRTT POWER ELECTRICAL
ASSEMBLY SCHEDULE FOR MORE INFO
FEMALE TO MALE POWER EXTENDER
CONNECTION EITHER IN CEILING OR IN FLOOR
- NO SPLITTER REQUIRED
WHERE ? : C = CEILING OR F = FLOOR
C
XXX XXX - CIRCUIT NO. (IN ITALIC)
HCZB??
FB
FB
POWER CHASSIS - INSTALL ARRANGEMENT
EITHER MOUNTED HORIZONTALLY OR
VERTICALLY TO A SUPPORTING STRUCTURE
BY OTHERS U.N.O.
EXTENDER CABLE 332 - 8 OR 4 WIRES
PATIENT CARE GRADE
(?? - CABLE TAG, SEE KEYNOTE P1)
FEMALE TO MALE POWER EXTENDER
CONNECTION IN INSIDE OF WALL SYSTEM -
NO SPLITTER REQUIRED
CEILING POWER DISTRIBUTION BOX
ZB?? - WHERE ?? IS THE ZONE BOX
NUMBER AFTER BEING INSTALLED ON SITE
XXX - CIRCUIT NO. (IN ITALIC)
XXX C
ZB??
FLOOR POWER DISTRIBUTION BOX
ZB?? - WHERE ?? IS THE ZONE BOX
NUMBER AFTER BEING INSTALLED ON SITE
XXX - CIRCUIT NO. (IN ITALIC)
XXX
ZB??
PATIENT CARE SPLITTER
CEILING MOUNTED
PATIENT CARE SPLITTER
INSIDE WALL MOUNTED
C
EXISTING PANEL MANAGER
- Designates Controlled Receptacle, see Controlled Receptacle legend for info.*
F
4 / 6 OUTLET POWER STRIP
INSTALL ARRANGEMENT EITHER MOUNTED
HORIZONTALLY OR VERTICALLY
EXTENDER CABLE 422
HORIZONTALLY WIRED IN DIRTT WALL
(?? - CABLE TAG, SEE KEYNOTE P1)
EXTENDER CABLE 332
HORIZONTALLY WIRED IN DIRTT WALL
(?? - CABLE TAG, SEE KEYNOTE P1)
SPLITTER
All splitters are in the ceiling unless otherwise specified W = Wall F = Floor E = Existing
DIRTT POWER MODULAR WHIP
?? : Whip TAG, See Electrical Schedule
XXX - CIRCUIT NO. (IN ITALIC)
All whips are in the ceiling unless otherwise specified ? : W = Wall OR F = Floor
XXX
MFT??
DIRTT POWER MODULAR WHIP
MALE TO FEMALE CONNECTION
?? : Whip TAG, See Electrical Schedule
XXX - CIRCUIT NO. (IN ITALIC)
All whips are in the ceiling unless otherwise specified ? : W = Wall OR F = Floor
XXX
MFT??
JUNCTION BOX WITH
DIRTT POWER MODULAR WHIP
XXX - CIRCUIT NO. (IN ITALIC)
All modular junction boxes are in the ceiling unless otherwise specified ?? : W = Wall OR F = Floor
XXX
JB
XXX
JB
JUNCTION BOX WITH
TWO DIRTT POWER MODULAR WHIPS
XXX - CIRCUIT NO. (IN ITALIC)
All modular junction boxes are in the ceiling unless otherwise specified ?? : W = Wall OR F = Floor
DIRTT WALL WITH CLERESTORY
DIRTT GLASSWALL WITH DOOR
DRYWALL
DIRTT POWER ACCESS MINI LOW PROFILE
FLOOR BOX
CAT# AFB202 (? - DEVICE OR DEVICES IN BOX)
FB ? ?
Cable Type E=Extender EL=Express line EHC=Patient care extender
P1: LABELING KEYNOTE
E 05 - 3 8W
Length (ft)
Wire Fill
3A = BLACK WIRE
3B = RED WIRE
3C = BLUE WIRE
4W = 4 wire 5W = 5 wire 8W = 8 wire *see wiring schematic
Wiring Configuration 3 = 332 independent neutral 4 = 422 shared neutral *see wiring shcematic
A. INSTALLATION STANDARDS: CABLE AND EQUIPMENT INSTALLATION COMPLY WITH THE
FOLLOWING STANDARDS:
2. CANADIAN ELECTRICAL CODE, 2018 (OR AS OBSERVED BY LOCAL)
REFERENCE CODES AND STANDARDS
1. NATIONAL ELECTRICAL CODE, 2018 (OR AS OBSERVED BY LOCAL)
DIRTT UL LISTING REPORTS
UL183 File Manufactured Wiring systems FILE # - E210896
UL514A File Metallic Outlet Box FILE # - E212646 QQYZ Wiring Assemblies FILE # - E328144
QQXX Sections and Units FILE # - E468975
UL507 Fans FILE # - E496838
UL KEZR Prefabricated Medical Headwalls FILE # - E499706
UL STANDARDS
UL 183 Standard for Safety for Manufactured Wiring Systems
UL 514A Standard for Safety for Metallic Outlet Boxes
UL 514C Standard for Nonmetallic Boxes and Covers UL 514D Standard for Cover Plates for Flush-Mounted Wiring Devices
UL QQXX Sections and Units ANSI/NFPA 70, “National Electrical Code” (NEC), 2008 Edition
ANSI/UL Standard 1286 - Office Furnishings
DIRTT CSA LISTING REPORTS
2117966 Class 6242 05/Class 6242 85 Power Harnesses, Power/conduit Whips, Power Extenders and Pre-wired Distribution Box & Junction Box Assemblies (level 3 & 4)
2563936 Class 4411 01/4411 81 Outlet Boxes and Fittings - Boxes
1514152 Class 4413 02/4413 82 Outlet Box and Fittings - Plates and cover Plates
1014788 Class 4612 01/4612 81 Boxes Miscellaneous
1039557 Class 6242 03/6242 83 Wiring Systems and Accessories - Modular
CSA STANDARDS
CAN/CSA C22.2 No. 0 General Requirements - Canadian Electrical Code Part CSA Standard C22.2 No. 203.1-94 - Manufactured Wiring Products
CAN/CSA Standard C22.2 No. 18.1-04 Metallic Outlet Boxes
CSA Standard C22.2 No. 42-1999 General Use Receptacles, Attachment Plugs and Similar Wiring Devices CSA Standard
C22.2 No. 42.1-2000 Cover Plates for Flush Mounted Wiring Devices
CSA Standard C22.2 No 203-M91 Modular Wiring Systems for Office Furniture
CSA C22.2 No. 0.4-04 Bonding and Bonding of Electrical Equipment (Protective Bonding)
3-3-2 SYSTEM 8 WIRE CONFIGURATION SCHEMATIC
8 WIRE CONFIGURATION
1. ALL FIRE RATED PLYWOOD BACK BOARDS ARE FURNISHED INSTALLED AND PAINTED BY OTHERS.
2. ALL CONDUIT PATHWAYS, BACK BOXES, CONDUIT PENETRATIONS AND SLEEVES OUTSIDE OF DIRTT WALLS ARE FURNISHED AND
INSTALLED BY OTHERS.
3. ALL HOUSE/BUILDING GROUND WIRING ARE TO BE FURNISHED AND INSTALLED BY OTHERS.
4. ALL ELECTRICAL ROUTING PATHS ARE FOR REPRESENTATION ONLY, THE ACTUAL ROUTING TO BE DETERMINED ON SITE BY OTHERS
5. ALL NETWORKING ROUTING PATH SHOWN IN OUR INSTALL DRAWING IS FOR CLARIFICATION PURPOSES ONLY. THE ROUTE TAKE DOES
NOT REPRESENT THE ACTUAL PATH TO BE USED FOR INSTALL
6. ALL COMPONENTS IN PLAN ARE CEILING/WALL COMPONENTS
AutoCAD SHX Text
XX#
AutoCAD SHX Text
AutoCAD SHX Text
SHC3
AutoCAD SHX Text
SCH3
AutoCAD SHX Text
SCH3
AutoCAD SHX Text
SCH3
AutoCAD SHX Text
BLUE
AutoCAD SHX Text
GREEN/YELLOW
AutoCAD SHX Text
WHITE/RED
AutoCAD SHX Text
WHITE/BLACK
AutoCAD SHX Text
BARE
AutoCAD SHX Text
BLACK
AutoCAD SHX Text
RED
AutoCAD SHX Text
L1 N1 G1 CIRCUIT "A"
AutoCAD SHX Text
L2 N2 G1 CIRCUIT "B"
AutoCAD SHX Text
L3 N3 IG CIRCUIT "C"
AutoCAD SHX Text L3
AutoCAD SHX Text L2
AutoCAD SHX Text L1
AutoCAD SHX Text CONNECTIONS TO A GROUNDED THREE-PHASE SYSTEM RATING: 120/208V, 3 PHASE WYE 60HZ, 20 AMP, WHITE RATED AT 20 AMP MULTIWIRE BRANCH CIRCUIT
AutoCAD SHX Text
RECPTACLE CONNECTIONS (LOAD)
AutoCAD SHX Text
WHITE/BLUE
GROUP
ROOM
A-404A
CONSULT
ROOM
B-401A
MULTI-PURPOSE
ROOM
B-429
CONSULT
ROOM
B-430
CONSULT
ROOM
B-431
CONSULT
ROOM
B-401B
CONSULT
ROOM
B-428
CLOSET
B-426
MEN'S
RESTROOM
B-425
WOMEN'S
RESTROOM
B-424
CONSULT
ROOM
B-422D
CONSULT
ROOM
B-422?
CONSULT
ROOM
B-422?
CONSULT
ROOM
B-422A
CONSULT
ROOM
B-421A
CONSULT
ROOM
B-420A
CONSULT
ROOM
B-416
CONSULT
ROOM
B-405
CONSULT
ROOM
B-406
CONSULT
ROOM
B-407
CONSULT
ROOM
B-408
CONSULT
ROOM
B-409
CONSULT
ROOM
B-410
CONSULT
ROOM
B-411
CONSULT
ROOM
B-412
CONSULT
ROOM
B-413
CONSULT
ROOM
B-414
CONSULT
ROOM
B-415
CORRIDOR
CRB402
B-412A B-409A
B-407AB-414A
B-406AB-415A
B-405AB-416A
B-417
B-418
B-418A
B-419
B-404
B-403
EMS
CLOSET
B-402
CORRIDOR
CRB401
ST2B401
FCB401
WHOLE
HEALTH
OFFICE
A-405
CONSULT
ROOM
B-420B
CONSULT
ROOM
B-421B
TEL/DATA
B-428A
CONSULT
ROOM
B-422B
CONSULT
ROOM
B-422?
C1C1
C2
C
C
C2
F1 F1
F1
F4
BH
F1
HD
BH
F1
F5F5
F4
BH
F2
HD
BH
F2
C2
C1C1
C
C
C2
F1
F7
BH
F1
HD
BH
F1
F4
F8 F8
BH
F2
HD
BH
F2
F9
C2
C1C1
C
C
C2
C
C
C2 C2
C1C1
C
C
C2
C1C1C1C1
C2C2 C2
C
C
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F4
BH
F1
HD
BH
F1
F2
BH
F2
HD
BH
F2
C
F21F21
F4
BH
F2
HD
BH
F2
F4
BH
F1
HD
BH
F1
F22F22
F4
BH
F2
HD
BH
F2
F23 F24
BHF1
HD
BHF1
F4
BHF2
HD
BHF2
F25
F26F26
F2
BH
F1
HD
BH
F1
L2 S
G
L2S G
L2S G
L2 S
G
L2 S
G
L2S G
L2 S
G
L2S G
L2 S
G
L2S G
L2 S
G
L2S G
E05-38W
E05-38W
MFT2
MFT37 MFT1 MFT1 MFT1MFT3
WB1
WB2
WB3
WB4
WB2
WB4
WB3
WB1
WB1
WB2
WB3
WB4
WB1
WB2
WB3
WB4
WB1
WB2
WB3
WB4
WB3
WB4
WB2
WB1
2 Circuits Phased A,B
2 Circuits Phased A,B
2 Circuits Phased A,B
2 Circuits Phased A,B
2 Circuits Phased A,B
E05-38WE05-38WE05-38W E05-38W
A S
A T
KL
A K
A L
A E
A F
WXIJ
0 29 Nov 22 DRAWN
Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D
IR
TT
E nv iro nm en ta l S ol ut io ns L td
DI
RT
T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y
DI
RT
T is ex pr es sly p ro hi bi te d.
D o no t u se d ra w in gs fo r s ca le p ur po se s.
A ll sit e di m en sio ns , d ra w in gs
, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to
D
IR
TT
in w rit in g be fo re p ro ce ed in g w ith w or k.
S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\___F_SIGNED off JOB\VA Brockton Mental Health Off 21Nov SATInstall R0.dwg 2022-11-29 3:07:52 PM
Project:
Drawn by:
Scale:
Date: 2022/11/29
DP-101
T.LUN
Project Address:
Project Name:
VA BROCKTON
MENTAL HEALTH OFF
Project Manager:
PM Phone #:
Date Revision Initial
FINAL
Rev
AS NOTED
DIRTT POWER
OVERALL PLAN
DP-101
FLOOR PLAN1
1/4" = 1'-0" / 1:48
F1 F1290F1292 F1F1292F1290
BHF1
HD1
BHF1
F4
BHF1
HD1
BHF1
F4F5F5 F5F5F4
BHF2
HD2
BHF2
F4
BHF2
HD2
BHF2
F1289 F7 F7 F1289
BHF1
HD1
BHF1
F4
BHF1
HD1
BHF1
F4
F8F8 F8 F8
BHF2
HD2
BHF2
F9 F9
BHF2
HD2
BHF2
F10 F12F11 F10F12 F11F14 F15F13 F15 F14 F13
F17F16 F16F17
F1285 F1288 F1285F1288
BHF1
HD1
BHF1
F4 F4
BHF1
HD1
BHF1
BHF2
HD2
BHF2
F20 C35 C35 F20
BHF2
HD2
BHF2
F21 F21 F21 F21
F4
BHF2
HD2
BHF2
BHF2
HD2
BHF2
F4 F4
BHF1
HD1
BHF1
F4
BHF1
HD1
BHF1
F22 F22 F22 F22
BHF2
HD2
BHF2
F4 F4
BHF2
HD2
BHF2
F23 F24 F24 F23
BHF1
HD1
BHF1
F4 F4
BHF1
HD1
BHF1
F25
BHF2
HD2
BHF2
BHF2
HD2
BHF2
F25 F26 F26 F26 F26
BHF1
HD1
BHF1
F27 F27
BHF1
HD1
BHF1
Elevation AS Elevation AT Elevation AU Elevation AVElevation AQ Elevation ARElevation AO Elevation AP
Elevation K Elevation L
Elevation G Elevation H
Elevation M Elevation N Elevation O Elevation P
Elevation AK Elevation ALElevation AE Elevation AF
Elevation W Elevation X
Elevation I Elevation J
Elevation AM Elevation AN
Elevation AG Elevation AH Elevation AI Elevation AJ
Elevation Y Elevation Z Elevation AC Elevation ADElevation AA Elevation AB
Elevation Q Elevation R Elevation S Elevation T
Elevation C Elevation DElevation A Elevation B Elevation E Elevation F
Elevation U Elevation V
Side A Side B Side A Side BSide A Side BSide A Side B
Side A Side B
Side A Side B
Side A Side B Side A Side B
Side A Side BSide A Side B
Side A Side B
Side A Side B
Side A Side B
Side A Side B Side A Side B
Side A Side B Side A Side BSide A Side B
Side A Side B Side A Side B
Side A Side BSide A Side B Side A Side B
Side A Side B
0 29 Nov 22 DRAWN
Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D
IR
TT
E nv iro nm en ta l S ol ut io ns L td
DI
RT
T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y
DI
RT
T is ex pr es sly p ro hi bi te d.
D o no t u se d ra w in gs fo r s ca le p ur po se s.
A ll sit e di m en sio ns , d ra w in gs
, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to
D
IR
TT
in w rit in g be fo re p ro ce ed in g w ith w or k.
S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\___F_SIGNED off JOB\VA Brockton Mental Health Off 21Nov SATInstall R0.dwg 2022-11-29 3:07:55 PM
Project:
Drawn by:
Scale:
Date: 2022/11/29
DP-301
T.LUN
Project Address:
Project Name:
VA BROCKTON
MENTAL HEALTH OFF
Project Manager:
PM Phone #:
Date Revision Initial
FINAL
Rev
AS NOTED
ELEVATION VIEWS
DP-301
ELEVATION VIEWS1
3/8" = 1'-0" / 1:32
DEVICES (WALL BOX)ELECTRICAL PANEL
EMT CONDUIT
THRU DRYWALL
WALL CLAMP
ELECTRICAL
PANEL
(BY OTHERS)
DIRTT POWER WHIP SPLITTER
WALL BOX WHIP
WALL BOX WHIP
EXTENDER
HOMERUN CONDUIT FROM
ELECTRICAL PANEL
POWER WHIP SPLITTER
EXTENDER WALL BOX WHIP
CONTRACTOR SUPPLIED &
INSTALLED
EXTENDER
DIRTT POWER COMPONENT DRAWING
CEILING
DIRTT SUPPLIED, SEE SCOPE OF
WORK DOCUMENT
HOMERUN CONDUIT FROM
ELECTRICAL PANEL
JUNCTION BOX
Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D
IR
TT
E nv iro nm en ta l S ol ut io ns L td
DI
RT
T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y
DI
RT
T is ex pr es sly p ro hi bi te d.
D o no t u se d ra w in gs fo r s ca le p ur po se s.
A ll sit e di m en sio ns , d ra w in gs
, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to
D
IR
TT
in w rit in g be fo re p ro ce ed in g w ith w or k.
S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg 2021-9-27 1:22:56 PM
Project:
Drawn by:
Scale:
Date: 2021/09/27
DP-502
Project Address:
Project Name:
DIRTT POWER 500 SERIES
Project Manager:
PM Phone #:
Date Revision Initial
Rev
AS NOTED
POWER WHIP COMPONENT
DRAWING - CEILING
DP-502
POWER WHIP COMPONENT DRAWING - CEILING1
1/4" = 1'-0" / 1:48.0008
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg, 9/27/2021 1:22:56 PM, DWG To PDF.pc3
TYPICAL POWER WHIP MOUNTING DETAIL
ABOVE DROP CEILING
CEILING TILE
THREAD ROD *
CONCRETE SLAB
UNISTRUT *
JUNCTION BOX PROVIDED BY
OTHERS
PIGTAIL WHIP PROVIDED BY DIRTT
CIEILING CONCRETE SLAB
TYPICAL POWER WHIP MOUNTING DETAIL
DECK MOUNTED
JUNCTION BOX (JB)
SCREWED TO SLAB *
JUNCTION BOX PROVIDED BY
OTHERS
PIGTAIL WHIP PROVIDED BY DIRTT
* MOUNTING HARDWARE AND
SUPPORT IS PROVIDED BY
OTHERS
CONCRETE SLAB
CONCRETE SLAB
THREAD ROD *
J-HOOKS *
TYPICAL SPLITTER MOUNTING DETAIL
ABOVE DROP CEILING WITH J-HOOKS
ELECTRICAL CLIP
SECURED TO DECK*
TYPICAL SPLITTER MOUNTING DETAIL
ABOVE DROP CEILING WITH CLIPS
CEILING TILE
Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D
IR
TT
E nv iro nm en ta l S ol ut io ns L td
DI
RT
T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y
DI
RT
T is ex pr es sly p ro hi bi te d.
D o no t u se d ra w in gs fo r s ca le p ur po se s.
A ll sit e di m en sio ns , d ra w in gs
, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to
D
IR
TT
in w rit in g be fo re p ro ce ed in g w ith w or k.
S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg 2021-9-27 1:22:58 PM
Project:
Drawn by:
Scale:
Date: 2021/09/27
DP-504
Project Address:
Project Name:
DIRTT POWER 500 SERIES
Project Manager:
PM Phone #:
Date Revision Initial
Rev
AS NOTED
POWER WHIP TYPICAL
MOUNT DETAIL - CEILING
DP-504
POWER WHIP TYPICAL MOUNT DETAIL - CEILING1
1/4" = 1'-0" / 1:48.0022
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg, 9/27/2021 1:22:58 PM, DWG To PDF.pc3
EXTENDER (3/3/2 OR 4/2/2)
SPLITTER (3/3/2 OR 4/2/2)
PIGTAIL MODULAR POWER WHIP (3/3/2 OR 4/2/2)
1 WHIP MODULAR JUNCTION BOX (3/3/2 OR 4/2/2)
2 WHIP MODULAR JUNCTION BOX
CONTROLLED CIRCUIT APPLICATIONS (3/3/2 OR 4/2/2)
4 OR 6 OUTLET POWER STRIP (3/3/2 OR 4/2/2)
3 GANG POWER CHASSIS (3/3/2 OR 4/2/2)
BLANK FACEPLATE
DATA/AV OPTIONS
-- N
OT USED ---
-- N
OT USED ---
Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D
IR
TT
E nv iro nm en ta l S ol ut io ns L td
DI
RT
T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y
DI
RT
T is ex pr es sly p ro hi bi te d.
D o no t u se d ra w in gs fo r s ca le p ur po se s.
A ll sit e di m en sio ns , d ra w in gs
, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to
D
IR
TT
in w rit in g be fo re p ro ce ed in g w ith w or k.
S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg 2021-9-27 1:23:00 PM
Project:
Drawn by:
Scale:
Date: 2021/09/27
DP-505
Project Address:
Project Name:
DIRTT POWER 500 SERIES
Project Manager:
PM Phone #:
Date Revision Initial
Rev
AS NOTED
MODULAR POWER
PARTS AND PIECES
DP-505
MODULAR POWER PARTS AND PIECES1
1/4" = 1'-0" / 1:48.0009
Project North True North
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg, 9/27/2021 1:22:59 PM, DWG To PDF.pc3
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
SCALE: NTS
-- N
OT USED ---
2" X 4.50" X 2.25" DEEP
OUTLET BOX (BY DIRTT)
WB##
4" X 4" X 2.25" DEEP
OUTLET BOX (BY DIRTT)
4" X 4.50" OUTLET COVER
PLATE (BY DIRTT)
WB##
BLANK COVER PLATE
CAN BE DATA
6" X 4.50" OUTLET COVER
PLATE (BY DIRTT)
6" X 4" X 2.25" DEEP
OUTLET BOX (BY DIRTT)
BLANK COVER PLATE
CAN BE POWER/DATA
WB##
WB##
8" X 4" X 2.25" DEEP
OUTLET BOX (BY DIRTT)
8" X 4.50" OUTLET COVER
PLATE (BY DIRTT)
BLANK COVER PLATE
CAN BE DATA
WB##
BLANK COVER PLATE
CAN BE DATA
TYPICAL 1 GANG MODULAR POWER WALL BOX
WITH STANDARD OUTLET (15A OR 20A)
TYPICAL 2 GANG MODULAR POWER WALL BOX
WITH STANDARD OUTLET (15A OR 20A)
TYPICAL 3 GANG MODULAR POWER WALL BOX
WITH STANDARD OUTLET (15A OR 20A)
TYPICAL 4 GANG MODULAR POWER WALL BOX
WITH STANDARD OUTLET (15A OR 20A)
TYPICAL 6 GANG MODULAR POWER WALL BOX
WITH STANDARD OUTLET (15A OR 20A)
5 XXX x
Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D
IR
TT
E nv iro nm en ta l S ol ut io ns L td
DI
RT
T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y
DI
RT
T is ex pr es sly p ro hi bi te d.
D o no t u se d ra w in gs fo r s ca le p ur po se s.
A ll sit e di m en sio ns , d ra w in gs
, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to
D
IR
TT
in w rit in g be fo re p ro ce ed in g w ith w or k.
S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg 2021-9-27 1:23:03 PM
Project:
Drawn by:
Scale:
Date: 2021/09/27
DP-506
Project Address:
Project Name:
DIRTT POWER 500 SERIES
Project Manager:
PM Phone #:
Date Revision Initial
Rev
AS NOTED
WALL BOX DETAILS
STANDARD OUTLETS
DP-506
WALL BOX DETAILS - STANDARD OUTLETS1
CUSTOM / 1:48.0024
Project North True North
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg, 9/27/2021 1:23:02 PM, DWG To PDF.pc3
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
EXTENDER CABLE RUN HORIZONTALTHRU
EXTRUSION CUTOUT
WALL BOX
WALL MOUNTED SPLITTER
WALL BOX WHIP
EXTENDER
CEILING MOUNTED
SPLITTER
EXTENDER
POWER WHIP
DIRTT WALL PANELS
NOT SHOWN
WALL BOX
WALL BOX WHIP
EXTENDER
CEILING MOUNTED
SPLITTER
EXTENDER
DIRTT WALL PANELS
NOT SHOWN
CEILING MOUNTED
SPLITTER
EXTENDER
DIRTT WALL PANELS
NOT SHOWN
POWER STRIP WHIP
EXTENDER
POWER STRIP
CEILING MOUNTED
SPLITTER
EXTENDER
DIRTT WALL PANELS
NOT SHOWN
EXTENDER
POWER CHASSIS
POWER WHIP
POWER WHIP
POWER WHIP
TYPICAL POWER WHIP CEILING DISTRIBUTION
WITH CLERESTORY WALLS - HORIZONTAL WIRING
TYPICAL POWER WHIP CEILING DISTRIBUTION
WITH SOLID WALLS SPLITERS IN CEILING
TYPICAL POWER WHIP CEILING DISTRIBUTION
WITH POWER CHASSIS (IF APPLICABLE)
TYPICAL POWER WHIP CEILING DISTRIBUTION
WITH POWER STRIP (IF APPLICABLE)
TYPICAL POWER WHIP CEILING DISTRIBUTION
WITH 2 WHIP JUNCTION FOR PLUG LOAD CONTROLLER WIRING
WALL BOX WHIP
EXTENDER
CEILING MOUNTED
SPLITTER
EXTENDER
POWER WHIP
DIRTT WALL PANELS
NOT SHOWN
CEILING MOUNTED
2 WHIP JUNCTION BOX
WALL BOX
PLUG LOAD CONTROLLER
(GC SCOPE)
PLUG LOAD CONTROLLER
WIRING (GC SCOPE)
EXTENDER CABLE RUN HORIZONTALTHRU
EXTRUSION CUTOUT
WALL BOX
WALL MOUNTED SPLITTER
WALL BOX WHIP
EXTENDER
IN-WALL MOUNTED
POWER WHIP
DIRTT WALL PANELS
NOT SHOWN
TYPICAL POWER WHIP MOUNTED IN WALL
WITH CLERESTORY WALLS - HORIZONTAL WIRING
Th is dr aw in g is th e co nf id en tia l a nd p ro pr ie ta ry in fo rm at io n of D
IR
TT
E nv iro nm en ta l S ol ut io ns L td
DI
RT
T) . A ny re pr od uc tio n, a lte ra tio n, d isc lo su re o r u se o f t hi s d ra w in g ot he r t ha n as a gr ee d to b y
DI
RT
T is ex pr es sly p ro hi bi te d.
D o no t u se d ra w in gs fo r s ca le p ur po se s.
A ll sit e di m en sio ns , d ra w in gs
, d et ai ls, a nd sp ec ifi ca tio ns c on ta in ed h er ei n m us t b e ve rif ie d by su b-co nt ra ct or s a nd a ny d isc re pa nc ie s m us t b e re po rt ed to
D
IR
TT
in w rit in g be fo re p ro ce ed in g w ith w or k.
S ee c ov er p ag e of d ra w in g pa ck ag e fo r f ul l d isc la im er
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg 2021-9-27 1:23:06 PM
Project:
Drawn by:
Scale:
Date: 2021/09/27
DP-509
Project Address:
Project Name:
DIRTT POWER 500 SERIES
Project Manager:
PM Phone #:
Date Revision Initial
Rev
AS NOTED
POWER WHIP TYPICAL
DETAILS - CEILING
DP-509
POWER WHIP TYPICAL DETAILS - CEILING1
1/4" = 1'-0" / 1:47.998
Project North True North
C:\Users\tlun\OneDrive - DIRTT Environmental Solutions\Drawings\____temp\New folder\DNP Power TZ500 - PW R0 - Std.dwg, 9/27/2021 1:23:05 PM, DWG To PDF.pc3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| VA Brockton Mental Health Off 21Nov SATInstall R0 |
| Sheets and Views |
| VA Brockton Mental Health Off 21Nov SATInstall R0-DG-001 |
| VA Brockton Mental Health Off 21Nov SATInstall R0-DG-002 |
| VA Brockton Mental Health Off 21Nov SATInstall R0-DP-101 |
| VA Brockton Mental Health Off 21Nov SATInstall R0-DP-301 |
| VA Brockton Mental Health Off - DNP Power TZ500 - PW R0 |
| Sheets and Views |
| DNP Power TZ500 - PW R0 - Std-DP-502 |
| DNP Power TZ500 - PW R0 - Std-DP-504 |
| DNP Power TZ500 - PW R0 - Std-DP-505 |
| DNP Power TZ500 - PW R0 - Std-DP-506 |
| DNP Power TZ500 - PW R0 - Std-DP-509 |
File details come from the government source that posted it. Updated .