This is a Material Ordering Data document for a specific electrical connector (Receptacle Assembly) for deep submergence submarine applications, detailed under MIL-C-24217 specification. The document provides comprehensive technical specifications for various connector configurations, including part numbers M24217/1-001 MOD through M24217/1-050, with precise dimensional details across multiple tables (Tables I, II, and III). Key technical requirements include packaging per MIL-E-17555 Level A, hydraulic shock testing per MIL-STD-202H, and no first article inspection or material certification requirements. The document references drawing BF2-1A08436 revision C, DETAIL PC 501, and was prepared by Broox Daniel with code 244.5, indicating a specific military/naval procurement context for electrical connectors with detailed manufacturing specifications.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SOLICITATION SPMYM2-25-Q-1241.pdf | ||
| ORDERING DATA for CLIN 0001.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MATERIAL ORDERING DATA
MIL-C-24217
IDN: N4523A 4330-1255
ICN: 38swd63303 KO: s01 KOI: 002
Paragraph 6.2 Ordering data
A. MIL-C-24217A, STANDARD SPECIFICATION FOR CONNECTORS,
ELECTRICAL, DEEP SUBMERGENCE, SUBMARINE, dated 5 Sep 1984. MIL-C- 24217A Supplement 1, dated 5 Sep 1984. MIL-C-24217A Amendment 1, dated 17 Jan 1989.
MIL-C-24217/1, Receptacle Assembly (Welded Type): The complete requirements for acquiring the receptacle assembly described herein shall consist of this document and the latest issue of MIL-C-24217.
B. Type of connector required (see 1.2): M24217/1-001 MOD
C. MIL-C-24217/1, STANDARD SPECIFICATION FOR RECEPTACLE ASSEMBLY
(WELDED TYPE), dated 5 Sep 1984. Notice 1 dated 3 Oct 1989. Complete part number: M24217/1-001 MOD
D. First article inspection is not required (see 3.2).
E. Material certification (see 3.3.2.1 and 4.6.1): NA
F. Hydraulic shock requirement (see 3.5.9): MIL-STD-202H
G. Test conditions if other than specified (see 4.3): N/A
H. Hydrostatic pressure quality conformance test requirements if intended working pressure is to exceed 6500 lb/in2 (see 4.7.5.2) N/A
I. Level of preservation and packing, packing and marking if other than specified in
5.1 (see 5.2) Packaged and marked for delivery in accordance with MIL-E-17555, Level A.
J. Polarization requirements if other than specified on the applicable specification sheet (see figure 2) NONE
Additional Data Requirements:
Requirements of DWG BF2-1A08436 / rev C DETAIL PC 501
REFERENCE PART# BF2-1A08436-501 CAGE 43689
Prepared By: BROOX DANIEL
Code: 244.5