Kineticor Motion Correction Technologies Generation II Quad camera prospective motion correction system and associated accessories Federal contract opportunity
Solicitation number
NIHDA201800536
Issued by
Department of Health and Human Services National Institutes of Health

About this file

Purchase Description

View the file

Other files for this federal contract opportunity

Other files attached to Kineticor Motion Correction Technologies Generation II Quad camera prospective motion correction system and associated accessories, newest first.
File Type Posted
NIHDA201800536_Combined_Synopsis_Solicitation.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PURCHASE DESCRIPTION

1. Statement of Need and Purpose:

The motion correction system is an add-on accessory to be used with a human MRI system and is manufactured by KinetiCor Motion Correction Technologies. This Quad Camera Prospective

Motion Correction System is an investigational device intended for use in providing head pose information for the purpose of correcting MRI images in real-time. The system adjusts the scanner measurements in real-time to produce clean images without artifacts due to motion. The motion correction system will allow state of the art high quality MRI studies that are performed of patients with compromised movement disorders such as MS, Epilepsy and compromised pediatric disorders.

2. Background Information and Objective:

The Functional and Molecular Imaging Section has two major research interests. One is to develop novel functional and molecular imaging techniques to study brain structure and function.

Emphasis is on MRI but some optical imaging is performed as well. Current areas of interest are to extend spatial resolution and understand the relation of functional MRI to neuronal architecture. Images with greater spatial resolution require more time to collect and are more prone to motion artifacts. Therefore, in order to further extend spatial resolution in human MRI, the issue of subject motion needs to be addressed. The Prospective Motion Correction System is essential to NINDS as it will be used in conjunction with the new 7T MRI system and allow for high-resolution Neurological case studies at the National Institutes of Health.

3. Generic Name of Product: Generation II Quad camera prospective motion Correction System

4. Purchase Description: Brand-name Specific

Kineticor Motion Correction Technologies Generation II Quad camera prospective motion correction system MRC-7T MR, compatible quad camera unit for patient viewing, ACC-PKG associated cabling & accessories package.

5. Salient characteristics:

In summary, the system consists of the following components:

• Camera insert with four HD cameras

• Processing Unit

• Fiduciary Markers

• Video Monitor, keyboard and Ethernet switch

More specifically, the contractor shall provide a system that consists of the following:

Product

Code Product Product Description Quantity

MRC-7T

A-1 MR Compatible

Quad Camera Patient

Viewing Wing Unit 7T

Retrofit quad camera unit (wing) and mounting brackets

1.00

MOCO-SW

A-2 Kineticor

Motion Correction

Software License

Software license for motion correction application to be used in conjunction with patient viewing wing and accessories

ACC-PKG A-3 Associated Cabling

& Accessories Package

System Accessories (cables, network switch, filter plate, filters, monitor, keyboard/mouse)

1.00

SE-PKG A-3 Systems Electronic

Package

Processing Unit 1.00

BB B-1 Bite Bar 25.00

CP-HDW B-1 Calibration Phantom 1.00

FP-PKG

B-2 Package for Xpace Motion correction sequences with custom sequence development tool kit

6. Installation and Training:

The Contractor shall provide on-site installation and calibrations services and training to the

NINDS MRI specialty staff.

7. Warranty/maintenance:

In addition to the one year standard warranty coverage; the contractor shall provide 1 year for

Kineticor Motion Tracking Software for updates, upgrades or developments after installation.

Additionally, contractor shall provide up to 40 hours over a two-year period for custom sequence libraries. The custom sequence libraries run in conjunction with the motion tracking software to keep the image free of motion artifacts. The 40 hour support will allow NINDS scientists to request a custom sequence (not-pre-designed); the Government will have the ability to contact the contractor to add the sequence to the software. Not to exceed 40 hours over two year period.

8. Quantity:

Item Number Description Manufacture Quantity

0001 Kineticor Motion Correction

Technologies Generation II Quad camera prospective motion correction system and associated accessories as specified in the purchase description.

Kineticor, Inc. 1

9. Delivery Date:

Delivery of all items shall be within 180 days after receipt of order to the following address:

9000 Rockville Pike, Building 10 , Room B1D69, Bethesda, MD 20892

Attn: Margie Reyes

All deliverables shall be packaged and shipped in accordance with Government specifications. At a minimum, all deliverables shall be marked with the contract number and Contractor name.