Amendment 1-Copy of Question Submittal Form_with responses.xlsx

XLSX spreadsheet 13 KB Posted

Attached to
DRY DILUTION REFRIGERATOR Federal contract opportunity
Solicitation number
NB686050-20-02311
Issued by
Department of Commerce National Institute of Standards and Technology

About this file

This document contains questions submitted and responses provided regarding Amendment 1 of Request for Quotation NB686050-20-02311 from the Department of Commerce National Institute of Standards and Technology for a dry dilution refrigerator. The questions and answers clarify pricing requirements, with optional items to be quoted separately from the total system price. Technical documentation needs only be provided if a contract is awarded. Input microwave cables should be quoted for either 12 or 24 coaxial lines, with 4 output microwave lines. Impedance values referred to are for the main impedance of the dilution unit.

View the file

Other files for this federal contract opportunity

Other files attached to DRY DILUTION REFRIGERATOR, newest first.
File Type Posted
Detailed Specifications for Item 1.pdf PDF
Combined Synopsis Solicitation.docx DOCX document
SOW_2020_Dilution_Refrigerator (002).pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

RFQ Question Submittal Form
Question No.RFP Amendment No.QUESTIONGOVERNMENT RESPONSE
111. Do you want to me to include the required Helium-3 with the system quotation or will you purchase that separately?Please quote the Helium-3 as an optional line item.
212. In Detailed specifications there are number of different technical documentations required. Should we include the documentation together with our bid/proposal or only after the contract/award (if we win)?These technical documents would only need to be provided if the contract is awarded.
313. In the SOW there are number of different options mentioned: A:Vibration isolation (not mentioned in the specifications), B & C: wiring, D: magnet shielding. Do you want me to include all those options into the total price of the price quotation or as an optional items that shows the pricing but is not included to the total price of the system?Please quote each of these as optional items (with pricing). They do not need to be included in the price of the total price of the system.
414.For the wiring option B and C, what is the required amount for input and output microwave cables?Please quote for 4 microwave output lines and either 12 or 24 coaxial input lines.
515. There was additional requirement under documentation section: “2. The values of all dilution refrigerator circuit impedances as well as the user/operator procedures for measuring their room temperature and low temperature values.” Do you mean the main impedance of the dilution unit or just electrical impedances of different resistors inside the cryostat?This refers to the main impedance of the dilution unit. If possible, providing the impedance value at the time of commision allows for comparison if the cryostat behavior changes over time.

File details come from the government source that posted it. Updated .