NB686050-24-02858 Statement of Work.pdf
PDF 147 KB Posted
- Attached to
- Sources Sought: Dilution Refrigerator Wiring Federal contract opportunity
- Solicitation number
- NB686050-24-02858
About this file
This document is a Statement of Work (SOW) for the procurement of dilution refrigerator wiring. The Advanced Microwave Photonics Group at the National Institute of Standards and Technology (NIST) recently ordered two dilution refrigerators and requires the installation of microwave coaxial lines to connect the low-temperature stages to room temperature, rated up to 18GHz. Each fridge requires two input lines for parametric amplifier biasing and two output lines that are superconducting below 4 Kelvin.
The SOW details the specific items and services required, including two Bluefors RF installation sets, four semi-rigid coaxial lines, and associated thermalization and attenuation requirements. The delivery timeframe is 8 months after award, with phased delivery acceptable. Installation and testing are estimated to take 3 weeks. No government-furnished material or equipment is identified. This SOW is related to a Sources Sought notice for dilution refrigerator wiring, with a NAICS code of 334516 (Analytical Laboratory Instrument Manufacturing) and a small business size standard of 1,000 employees. Interested vendors are requested to submit capability statements by July 22, 2024.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work: Dilution Fridge Wiring 1 Last Saved: 7/11/2024 2:54 PM Double-click on for further assistance.
Use this Statement of Work document to purchase an item and/or item-related services.
TITLE: Dilution Fridge Wiring Requesting Lab/Division/Group: PML, Applied Physics Division, Advanced Microwave Photonics Requisition Number: NB686050-24-02858
Statement of Need The Advanced Microwave Photonics Group recently placed an order for two dilution refrigerators. To perform high speed, low noise microwave measurement of superconducting qubits, these refrigirators need to be outfitted with microwave coaxial lines connecting the low temperature stages to room temperature, rated up to 18GHz. Each fridge will require two input lines for parametric amplifier biasing and two output lines that are superconducting below 4 Kelvin. The coaxial lines need to be properly attenuated and thermalized at the different temperature stage to ensure proper operation of the dilution fridge.
Items and/or item-related services Section Requirements Related Information Items/Service (required)
- Two Bluefors RF installation Set KF40 4x SMA, RT-4K
- Two Bluefors RF installation Set KF40 4x SMA, 4K-MXC
- 4 Semi-rigid Coaxial lines (18GHz), 2.19mm SCuNi-CuNi from RT to 4K and 0.86mm NbTi- NbTi from 4K to MXC
- 4 Semi-rigid Coaxial lines (18GHz), 2.19mm SCuNi-CuNi from RT to 4K and 0.86mm SCuNi- CuNi from 4K to MXC ☐ See attached document for detailed specifications
Standard options from manufacturer
Shipping & Delivery ☐ N/A
8 Months ARO ☐ Phased delivery is acceptable ☐ Software on USB / disk required ☐ Software electronic delivery acceptable Email address for software delivery
Needs to be installed when refrigerators are commissioned.
Installation ☒ N/A
Installation requirements ☐ Site visit recommended
Enter related information here
Inspection and Acceptance ☐ N/A
Inspection requirements ☒ Government acceptance expected to take longer than 7 days
Installation and testing will require an estimated duration of 3 weeks.
Warranty ☐ N/A
Base Manufacturer Warranty is acceptable If you require an Extended Manufacturer Warranty, describe the warranty
Statement of Work: Dilution Fridge Wiring 2 Last Saved: 7/11/2024 2:54 PM Double-click on for further assistance.
requirements.
Period Length:24 month ☐ Option Period 1 ☐ Option Period 2 ☐ Option Period 3 ☐ Option Period 4
Training ☒ N/A
Training requirements Enter related information here
Maintenance
☒ N/A
Describe your maintenance requirements.
☐See attached document for detailed maintenance specifications Period Length: Ex. month, 6 month, year etc.
Enter related information here
☐ Option Period 1 ☐ Option Period 2 ☐ Option Period 3 ☐ Option Period 4
Repair ☒ N/A
Choose an item.
Describe your repair requirements.
Period Length: Ex. month, 6 month, year etc.
Enter related information here
☐ Option Period 1 ☐ Option Period 2 ☐ Option Period 3 ☐ Option Period 4
Government Furnished Material / Equipment ☒ N/A
List any government furnished material/equipment here
Enter related information here
Travel ☒ N/A
Describe any travel requirements Vendor: To the maximum extent possible, include as part of appropriate sections above (maintenance, repair, etc.).
Otherwise, it will be a separate line item, reimbursable per the Federal Travel Regulation.
| Use this Statement of Work document to purchase an item and/or item-related services. |
| TITLE: Dilution Fridge Wiring |
| Requesting Lab/Division/Group: PML, Applied Physics Division, Advanced Microwave Photonics |
| Requisition Number: NB686050-24-02858 |
Statement of Need
File details come from the government source that posted it. Updated .