24Q0243 Amendment 1.docx

DOCX document 31 KB Posted

Attached to
Fluorimeter System Federal contract opportunity
Solicitation number
N6893624Q0243
Issued by
Department of the Navy Naval Air Systems Command Naval Air Warfare Center

About this file

This document is an amendment to a solicitation for a Fluorimeter System by the Naval Air Warfare Center, Weapons Division, China Lake, CA. The amendment changes the procurement from a sole source to a full and open competition Request for Quote (RFQ). The solicitation outlines the system requirements, which include an excitation source, laser source, emission detector, monochromators, polarizers, capability for absolute quantum yield measurements, lifetime analysis, time-resolved emission spectra, and data processing software. The system must operate within a 200-900 nm wavelength range, have a sensitivity of S:N >10,000:1, and resolution of 0.5 nm. The solicitation also specifies requirements for the sample holder, installation, training, and computer system. The RFQ will be posted on the Contract Opportunities website on or around August 26, 2024, and all responsible sources may submit a quote.

View the file

Other files for this federal contract opportunity

Other files attached to Fluorimeter System, newest first.
File Type Posted
Commercial Solicitation N6893624Q0243.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N6893624Q0243

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION C - DESCRIPTIONS AND SPECIFICATIONS

The following have been modified:

STATEMENT OF REQUIREMENTS

The system shall include:

· An excitation source:

· Xenon arc lamp

· Laser source for TCSPC

· 375-405 nm (±5 nm) picosecond pulsed diode laser

· Wavelength range: 200 nm – 900 nm

· Adjustable bandwidth from 1-30 nm

· Emission detector

· PMT

· Wavelength range: 250 – 900 nm

· Sensitivity of S:N >10,000:1

· Resolution of ±0.5 nm

· Monochromators

· Czerny Turner excitation and emission monochromators

· Double-grating with 1200 grove/mm

· Polarizers

· Glan-thompson polarizers and analyzers

· Can be moved into and out of beam and at angles from 0 to 90°

· Absolute Quantum Yield Measurements

· Internal integration sphere of at least 120 mm and directly integrated into the sample compartment and no fiber optics or software calculations required

· Ranges from 0 – 100%

· Accuracy to ±1%

· Lifetime Analysis (TCSPC)

· Lifetime range of 100 ps to 10 µs

· Time resolved to 10 ps

· Repetition rate of 5 KHz to 100 MHz

· Time Resolved Emission Spectra (TRES) acquisition

· Software

· Windows OS

· Capable of real-time data acquisition, quantum yield calculations, lifetime analysis, peak fitting, control of lamps and monochromators and detectors, kinetic data processing

· Data export into CSV, TXT, PDF, ASCII

· Decay curve analysis

· Anisotropy

· Polarization studies/experiments

· 120V Power Requirement

· Sample Holder

· Standard cuvette holder

· Filter set with several long-pass filters

· Solid sample holder

· Installation and Training

· On-site training

· Computer system

· Computer with preloaded software

· Monitor

· Keyboard and mouse

SECTION L - INSTRUCTIONS, CONDITIONS AND NOTICES TO BIDDERS

The following have been added by full text:

52.252-3ALTERATIONS IN SOLICITATION (APR 1984)
Portions of this solicitation are altered as follows:

Included the below additional SPECS details in Section C, Specification Requirements:

Laser source for TCSPC

· 375-405 nm (±5 nm) picosecond pulsed diode laser