Statement of Work RF Control Hardware 02/23/2017

1.0 Scope/Background

In order to meet current and future requirements of Naval Air Warfare Center Weapons Division, China Lake (NAWCWD), the RF Systems and Development branch (Code 472200D) is upgrading the Ka-Band Instrumentation Radar (KBIR). The Government intends to procure two (2) waveform generators. The components shall be used for signature collection or radar cross section of UAVs and are necessary to support the waveform that will be used in the upgraded KBIR.

2.0 Applicable Documents

None

3.0 Requirements/Specifications

The following describes the specifications for the two (2) waveform generators to be procured, which will consist of two (2) Arbitrary Waveform Generators. Each device shall be capable of meeting the requirements of upgrading an existing Ka-Band instrumentation radar. All specifications are the minimum requirements unless otherwise stated.

3.1 The Arbitrary Waveform Generator Shall Meet the Following Specifications:

3.1.1 General characteristics:

· Primary use: Waveform generator for instrumentation radar

· Compatible with industry standard RF equipment

· Spurious Free Dynamic Range

· Operable as a stand-alone unit

3.1.2 The Contractor shall meet the following detailed specifications: The products listed in the tables below represent the required capabilities for the delivered units. The delivered units shall include all of the listed options.

Table 1. Arbitrary Waveform Generator Requirements

2 Units

Memory depth
2 Giga-Samples/channel
Nominal Sample Rate
5 Giga-Samples Per Second (GSPS)

4 Channels/unit

DC Output

Range
1.5 Volts peak to peak (Vp-p)
Offset
+/- 2.25 Volts (V)
Max Freq. Output (-3dB)
2 Gigahertz (GHz)
Accuracy
+/- 1 milivolt (mV)

Amp. AC Output

Range
-60 decibel miliwatts (dBm) to +10 dBm
Offset
+/- 8 V @ 200 milliamps (mA)
Frequency Output
10 MHz – 4 GHz

Output flatness

±1.5 dB 10 megahertz (MHz) to 1 GHz, ±2.5 dB 10 MHz to 2 GHz

±0.1 dB 10 MHz to 3 GHz (w/pre-emphasis and calibration)

Maximum sequencing steps
16,383

Spurious Free Dynamic Range (SFDR) characteristics

Frequency output of AWG measured in frequency range fout = 10 MHz to 1 GHz

10 MHz to 1 GHz
<-65 decibels relative to the carrier (dBc)
10 MHz to 2 GHz
<-65 dBc
10 MHz to 3 GHz
<-65 dBc
10 MHz to 4 GHz
<-65 dBc

measured in frequency range fout = 10 MHz to 2 GHz

10 MHz to 1 GHz
<-60 dBc
10 MHz to 2 GHz
<-60 dBc
10 MHz to 3 GHz
<-60 dBc
10 MHz to 4 GHz
<-60 dBc

measured in frequency range fout = 10 MHz to 3 GHz

10 MHz to 1 GHz
<-55 dBc
10 MHz to 2 GHz
<-55 dBc
10 MHz to 3 GHz
<-55 dBc
10 MHz to 4 GHz
<-55 dBc

measured in frequency range fout = 10 MHz to 4 GHz

10 MHz to 1 GHz
<-50 dBc
10 MHz to 2 GHz
<-50 dBc
10 MHz to 3 GHz
<-50 dBc
10 MHz to 4 GHz
<-50 dBc

Two-tone IMD

1 GHz+/-1 MHz
-60 dBc
2 GHz+/-1 MHz
-55 dBc
3 GHz+/-1 MHz
-50 dBc

Jitter

Random jitter (estimate)
250 femto seconds (fs) Root Mean Square (RMS)
Total jitter (estimate)
10 picoseconds (ps) (peak to peak)

Hardware characteristics

Number of analog outputs
4 channels
Output connector
SubMiniature A (SMA)
Output impedance
50 Ω
Waveform length
2 GigiSamples

Waveform granularity

Continuous run mode
1 point
Triggered run modes
1 point

Run modes

Continuous
Waveform is continuously repeated
Triggered
Waveform is output only once after a trigger is received
Triggered Continuous
Waveform is continuously repeated after a trigger is received
Computer characteristics
Download waveform via Universal Serial Bus (USB) or Ethernet

Utility outputs

Markers
Total of 16 (4 per channel)

Synchronization clock output

Frequency
fclock/32
Amplitude
0 dbm
Connector
SMA (rear panel)
Impedance
50 Ω, AC coupled

External clock output

Connector
SMA on rear-panel
Output impedance
50 Ω AC Coupled
Frequency range
2.5 GHz to 5.1 GHz
Output amplitude
+5 dBm to +10 dBm

Inputs

Trigger to output uncertainty
Asynchronous ±200 ps at maximum sample rate

Reference in

Input amplitude
-5 dBm to +5 dBm
Fixed frequency range
10 MHz, ±10 ppm
Variable frequency range
35 MHz to 250 MHz
Connector
SMA (rear panel)
Impedance
50 Ω, AC coupled

External Clock in

Connector
SMA (rear panel)
Input impedance
50 Ω, AC coupled
Frequency range
2.5 GHz to 5.1 GHz
Input amplitude
0 dBm to +10 dBm

3.2 Delivery/Acceptance:

3.2.1 All components shall be delivered within 360 calendar days of contract award. The components will be inspected by a Government representative at the Government’s facility.

3.2.2 Acceptance of the components is contingent upon delivery of the components to the Government’s facility and successful determination and demonstration of all specifications identified in Sec. 3.1 above. The Government will determine acceptance of the units within 30 days of receipt.

3.3 The contractor shall provide a standard, commercial warranty.

4.0 Deliverables

4.1 Waveform Generators: Quantity two (2) AWG5200 units, fully adhering to the specifications/requirements in Sec. 3.1 Table 1.