Tate-ConCore 1250-HPL-Stone Grafix.pdf

PDF 306 KB Posted

Attached to
Construction - B1302 R207 Renovation Federal contract opportunity
Solicitation number
N6660423Q0011
Issued by
Department of the Navy Naval Sea Systems Command

View the file

Other files for this federal contract opportunity

Other files attached to Construction - B1302 R207 Renovation, newest first.
File Type Posted
RFI _2 _and _3_.pdf PDF
RFI _1_ B1302 Rm207.pdf PDF
N6660423Q0011Amendment0002.pdf PDF
N6660423Q0011Amendment 0001.pdf PDF
II. H. Attachment 5_Covid Questionnaire.pdf PDF
N6660423Q0011.pdf PDF
II. H. Attachment 4 RI WD 09-09-2022.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ConCore 1250-24"

With HPL

CORNER DETAIL

Welded assembly at domes and perimeter

Cementitious core material

TOP VIEW

Full hard cold rolled steel top sheet

Painted finish

Draw quality steel bottom pan with structural dome design

UNDERSTRUCTURE OPTIONS

Protected from corrosion by an epoxy paint finish.

All steel welded construction filled internally with a

Non-combustible material.

Class A flame spread rating.

cementitious core material.

Panel weight : 8.6 lbs./ft² (with tile).

General information

SPECIFICATIONS

System Performance Criteria (Tested on Actual Understructure)

Panel Understructure

SYSTEM

WEIGHT

System Type

Design

Loads

STATIC LOADS

10 Passes 10,000 Passes

ROLLING LOADS

IMPACT

LOADS

Tate Access Floors, Inc.

7510 Montevideo Road

Jessup, MD 20794

Tel (410) 799-4200 Fax (410) 799-4207

1/16" Conductive HPL__________(Color)____________

1/16" HPL_______________(Color)________________

Tile factory laminated with integral trim edge

4' Bolted Stringer

COVERING OPTIONS

© 2008 Tate Access Floors, Inc.

R 8/30/21

Laminated Panel With Integral Trim

1-3/8" deep at corners

1-5/8" deep

Ultimate Loads Safety Factor

1. System Design Load is based on permanent set ≤ 0.010" and is verified by loading panels in accordance with the CISCA concentrated load method but with panels installed on actual understructure instead of steel blocks. (Testing on blocks does not represent performance of an actual installation.) Ultimate, Rolling, and Impact Load tests are performed using CISCA test procedures.

2. Safety Factor is Ultimate Load divided by Design Load.

Bolted Stringer

49.3 kg / m²

10.1 lbs / ft²

567 kg

1250 lbs

68 kg

150 lbs

454 kg

1000 lbs 800 lbs

363 kg

Min. 2

Min. 2500lbs

Min. 1134kg

ConCore 1250 Panel-24" With