STATEMENT OF WORK
CX4 to Unity refresh
1.0 BACKGROUND
Naval Undersea Warfare Center Division, Newport (NUWCDIVNPT), Code 1041, is required to upgrade the EMC CX4 Storage Area Network (SAN). The EMC CX4 SAN has reached its end of life and end of service life. In the very near future spare parts for the current EMC CX4 SAN will not be available. Code 1041 must refresh the EMC CX4 to a UNITY 400 SAN in order to keep the SAN up-to-date and technically viable. A certified EMC field engineer is required onsite to install and configure the new EMC UNITY 400 SAN, bring the new UNITY 400 SAN online, and migrate all the data from the EMC CX4 SAN to the EMC Unity 400.
2.0 SCOPE
In collaboration with the NUWC Technical Point of Contact (TPOC), the contractor shall configure, implement, test, and migrate the new EMC Unity 400 SAN in NUWCDIVNPT Building 104, Room 101 datacenter.
| 3.0 | APPLICABLE DOCUMENTS |
| 3.1 | |
| Dell EMC Unity Best Practices Guide |
| 3.2 |
| EMC Unity Hybrid and Unity All Flash Installation Guide |
| 3.3 |
| Hardware Information Guide - EMC Corporation |
| 3.4 |
| EMC Unity Setup Guide | ESXsi |
| 3.5 |
| EMC Unity™ Quick Start - EMC Corporation |
4.0 REQUIREMENTS
In accordance with applicable documents the contractor shall:
| 4.1 | Implement and configure an EMC Unity 400 SAN turnkey solution utilizing a certified EMC engineer. |
| 4.2 | Create configuration documentation that can be used as a reference guide for implementation and configuration expansion. |
| 4.2.1 | The contractor shall provide configuration documentation of the Unity 400 solution in accordance with CDRL A001. |
| 4.3 | Migrate data from the current EMC CX4 SAN to the new EMC Unity SAN. |
| 4.4 | Install new system in rack space identified utilizing existing infrastructure in NUWCDIVNPT Building 104, Room 101 datacenter. |
| 4.5 | Cutover to the new Unity 400 SAN and turn down the old EMC CX4 SAN. |
| 4.6 | Provide the Government with the necessary rights, privileges, and credentials required to self-maintain the Unity 400 SAN. |
| 4.7 | Provide all existing administrator privileges and credentials identified within the new SAN application and activate prior to acceptance of the system by the Government. |
| 4.8 | Provide basic maintenance training to the NUWCDIVNPT code 1041 SAN administrators. |
4.9 Provide daily updates of the progress on the installation and migration of the SANs in accordance with CDRL A002.