DWG_0356_Locking Pellet Installation Torque Testing Procedure for Non-DoD Entities.pdf
PDF 89 KB Posted
- Attached to
- CLB Inconel 718 Fasteners Procurement Federal contract opportunity
- Solicitation number
- N6449820R4051
About this file
This document provides a procedure for installing locking pellets and conducting torque testing of threaded fasteners for non-Department of Defense entities. The procedure outlines requirements for pellet sizing, installation, cutting flush with the fastener thread, diameter measurement and verification by quality assurance inspectors. Fasteners must also undergo torque testing to specified minimum breakaway torque values in the presence of inspectors. Tests must be re-done if unsatisfactory, with one retest allowed before part disqualification. Threads and pellet holes will be inspected for damage as part of the process.
The related federal contract opportunity is a solicitation from the Department of the Navy Naval Sea Systems Command for procurement of Inconel 718 fasteners. The contractor will be responsible for producing various threaded fasteners per the applicable drawings on a firm-fixed-price basis, with additional optional items. Data deliverables are required.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N6449820R4051 Amend 0001.pdf | ||
| CDRL A001 - Material Testing Results_200318_NFPC Signed_approved.pdf | ||
| CDRL A002 - Certification Package_200318_NFPC Signed_approved.pdf | ||
| RFQ_N6449820R4051_Inconel Fasteners.pdf | ||
| CDRL A003 - Contract Status Report_200318_NFPC Signed_approved.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NO. TITLE IDENT
REFERENCES
DISTRIBUTION STATEMENT A
APPROVED FOR PUBLIC RELEASE
DISTRIBUTION IS UNLIMITED
UNITS AND TOLERANCES DEPARTMENT OF THE NAVY
NORFOLK NAVAL SHIPYARD DETACHMENT
NAVAL FOUNDRY AND PROPELLER CENTER
PHILADELPHIA, PA
Locking Pellet Installation & Torque Testing Procedure for Non-DoD
Entities
PREPARED
Brett Pierce
DATE
11/4/19 SIZE CODE IDENT: NFPC DRAWING NO. REV
CHECKED
Chris Clark
11/4/19 A CODE
1420 0356 - PROJECT ENG
Chris Clark
11/4/19
APPROVED
Nate Bird
See Digital
Signature
SCALE: None SHEET 1 OF 2
N/A
REVISIONS
REV ZONE DESCRIPTION DATE APPROVED
- N/A INITIAL RELEASE See Digital Signature
Purpose:
This drawing provides instructions for installation of self-locking pellet and torque testing of threaded fasteners by Non-DoD Entities. Instructions per this drawing are in accordance with requirements of UIPI 5050-904B
Pellet Installation & Torque Testing Procedure:
1. The vendor shall manufacture a locking pellet in accordance with the applicable drawing or contract.
Pellet must be sized to create a light interference fit with the pellet hole.
2. The vendor shall install a pellet in each fastener.
3. The vendor shall use a sharp knife to cleanly cut the locking pellet approximately flush with the fastener thread major diameter.
4. The vendor shall measure the fastener diameter at the pellet. This diameter must be of the size and within the tolerance given in the applicable drawing or contract. Quality Assurance Inspectors from the Naval Foundry and Propeller Center must be on-site at the vendor’s location to verify the results.
5. The vendor shall perform a torque test on all pelletized fasteners as follows:
a) Insert the fastener into an appropriate nut or test fixture until the pellet is fully engaged. The threads of the nut/test fixture shall be of the same nominal size and thread class as the fastener being tested.
b) Using a calibrated torque wrench, measure the breakaway torque required to remove the fastener.
The required minimum breakaway torque value will be given in in the applicable drawing or contract.
Quality Assurance Inspectors from the Naval Foundry and Propeller Center must be on-site at the vendor’s location to witness the tests.
Note: If a test proves unsatisfactory for these requirements, remove the pellet, inspect the part for damage, install a new pellet in accordance with this procedure and retest the fastener. This retest may be performed once before disqualifying the part.
6. Inspect the fastener threads for any damage. Noticeable distortion or scratches deep enough to reduce the efficiency of the threads, or any elongation of the pellet hole, shall be considered a failure of the self– locking element.
SIZE CODE IDENT CODE 1420 DRAWING NO. REV
A
CODE 1420
0356 - SCALE: None SHEET 2 OF 2