SOW_RFI_Posting.pdf
PDF 226 KB Posted
- Attached to
- Weapons Impact Scoring Set Portable Retractable Tower RFI Federal contract opportunity
- Solicitation number
- N64267-16-T-0247
About this file
Attachment 1 DRAFT - SOW
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFI_for_Portable_Tower_Trailer.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Rev 3/31/16
STATEMENT OF WORK
RS32 - Weapons Impact Scoring Set Portable Retractable Tower
Purchase Request Number: TBD
1. INTRODUCTION
The Naval Surface Warfare Center Corona Division (NSWC CODIV), Range Systems Department, Code 32
(RS32) requires and IDIQ contract for the portable towers in support of RS32 SR-D-SAI WISS v5.
2. BACKGROUND
The SR-D-SAI WISS v5 has a requirement to support the scoring systems and training aids/devices at
Royal Saudi Air Force (RSAF) Saudi Arabia ranges with spare parts and technical assistance. In order to meet these requirements, RS32 requires the portable towers listed in this SOW.
3. SCOPE
Request for an IDIQ contract for the portable towers listed in this SOW.
4. APPLICABLE DOCUMENTS
N/A
5. REQUIREMENTS
ANTICIPATED 5 YEAR ORDERING PERIOD:
CLIN MIN QTY MAX QTY PART NUMBER PART
DESCRIPTION
0001 2 20 TBD Portable Tower
Trailer
Trailer Salient Characteristics
1. Trailer assembly should be constructed of galvanized steel .
2. Trailer shall have incorporated trailer braking system(s) with emergency breakaway brakes.
3. Trailer shall be equipped with a wheel and spare tire of the same type as mounted on trailer.
4. Trailer shall have 1/8 inch diamond plate decking.
5. Trailer shall be equipped with and aluminum storage box for cables etc.
6. Trailer shall have both a standard ball and “Pintle” hitch mount for tower.
7. Trailer hitch height shall be able to be adjusted via motorized electrical height adjusting mechanisms.
8. Trailer shall have retractable outrigger type leveling jacks mounted on all four corners of the trailer.
9. Trailer shall have all DOT necessary obstruction and warning lights and cabling to attach to tow vehicle.
10. Tower assembly shall be constructed of heavy duty aluminum material to reduce weight and provide protection from harsh desert environments.
11. Tower height when erected shall be approximately 60 feet above ground level (AGL) +/ -
5 feet.
12. Tower shall have no more than TWO total sections.
13. Tower shall be able to be fully erected and stabilized without the need of supporting guy wires.
14. Trailer/Tower shall be C-130 aircraft transportable when retracted and stowed.
15. Tower shall be able to be erected using DC power from a tow vehicle and or from self -contained on board battery power.
16. Tower/Trailer shall have an on board battery system and battery system charger capable of erecting and retracting the tower without aid of outside power.
17. Tower erection shall be cable of using 12 Volts or 24 Volts DC power directly from the tow vehicle without the aid of an additional source of power.
18. Tower shall be able to support a payload of up to 300+ pounds at the top of the tower when erected.
19. Tower shall have radial pressure slide bar system that would eliminate the use of guy wires for tower stability.
Required Modifications
20. Trailer shall be equipped with a wheel and spare tire of the same type as mounted on axles. Spare tire shall be mounted at the nose of the trailer close to the hitch structure.
21. Trailer shall have a 6’ ladder mounted securely on the right rear outrigger.
22. Tower and trailer shall be painted and/or powder coated “Desert Tan” matte finish, use color matching system RAL #33446. This includes all galvanized steel and aluminum surfaces.
23. Tower shall have top-mount support base plate and beam to account for three WISS scoring camera adjustment rotors.
24. Trailer shall have copper ground point mounted on the top toward the rear of deck to provide grounding of trailer and tower to earth ground during operation.
25. Trailer shall have a second empty aluminum box without cutouts mounted on the opposite (left) side of the battery box.
26. Trailer shall have quantity of 2ea 7000-pound rated drive axles.
27. Tower shall have two mounting brackets for microwave radio assembly welded at the top of the lower section.
28. Tower shall have two Quick Detach Microwave Mount for the microwave brackets.
29. Trailer shall have added deck structural support that is perpendicular to the long edge of the deck to accommodate three solar pedestals (450 pounds each).
30. Tower shall have electrical and mechanical support to extend 10 feet from nested state in the horizontal position.
31. Tower shall have two mounting brackets for cable track that is capable of supporting the weight of the track and the internal cables at the minimum 50 pounds total. Each bracket is to be welded at the top of each tower section.
32. Trailer shall have all winches’ power and control connectors in an enclosure at the tower support structure on the right accessible by the operator while standing on the ground.
All wiring must be permanent accept for the handheld controllers.
33. Trailer shall accept two alternate power sources to run both tower winches. External power sources from tow truck can be either 12 Volt Deep Cycle (VDC) or 24VDC. All wiring must be permanent so that it requires minimal set-up time.
34. Trailer shall have three actuator sets bolted on the deck at designated locations.
Actuator and bracket shall have the following part numbers from Progressive
Automations: PA-17-18-2000 and BRK-17.
35. Trailer shall have +12VDC deep-cycle gel type batteries and are capable of operating in
60 degree Celsius ambient temperature. These batteries shall be capable of delivering at the minimum 105 Amp Hours at 20 hour rate and Cold Cranking Amp of 680.
36. Tower shall have a strap mounted on the lower section to secure a cable track. Cable track will be on top side of tower during stow position. This strap shall be mounted 12’ below the top of the lower tower section.
37. Tower shall have two 2” aluminum bars welded on the left side of the lower tower section for junction box (JB) mount.
38. Trailer solar panel for the winches shall have sand-blasted collective surface to diffuse laser reflection.
39. Tower shall have an aluminum pipe that is 2” diameter and 4” in length welded to the right side of the lower tower section as the cable track guide.
6. GOVERNMENT FURNISHED PROPERTY
N/A
6.1 Government Furnished Material
N/A
6.2 Government Furnished Equipment
N/A
6.3 Government Furnished Information
N/A
7. DELIVERABLES
N/A
8. ACRONYM LIST
ACRONYM DENOTATION
NSWC CODIV Naval Surface Warfare Center Corona Division
RS32 Range Systems Department, Code 32
RSAF Royal Saudi Air Force
RAL Color Matching System Standard
JB Junction box
WISS Weapons Impact Scoring Set
THIS PAGE CONTAINS NECESSARY INFORMATION FOR THE PROCUREMENT ACTION
A. REQUIRED INITIAL DELIVERY DATE FOR 2 UNITS:
31/DEC/2016
B. SHIPPING ADDRESS
Naval Surface Warfare Center, Corona Division
Attn: TBD
1999 Fourth St
Norco, CA 92860-1915
File details come from the government source that posted it. Updated .