ORDERING DATA SHEET - GENERAL

PUMP SPECIFICATION

TECHNICAL REQUIREMENTS: (PER DRAWING 2301-3649, NOTE M5)

- CENTRIFUGAL IMPELLER

- CANNED ROTOR

- DRY STATOR CAVITY

- HERMETICALLY SEALED

- 300 SERIES STAINLESS STEEL PUMP CASE AND ROTOR

- DESIGN TEMPERATURE: 220°F

- DESIGN PRESSURE: 150 PSIG

- NPSH REQUIRED: <20 FEET

- HEAD PRESSURE: >75 FEET @ 30 GPM

- DISCHARGE CONNECTION: 1-1/2”, ASME B16.5, CLASS 150, RAISED FACE FLANGE

- SUCTION CONNECTION: 2”, ASME B16.5, CLASS 150, RAISED FACE FLANGE

- DIMENSIONAL ENVELOPE: 15-3/4” LONG X 9-3/4” WIDE X 21” HIGH

- VOLTAGE: 460 VAC, 3-PHASE

ADDITIONAL OPTIONS THAT MUST BE SPECIFIED TO THE VENDOR:

- INSTALLED PUMP ROTATION INDICATOR

- RUBBER PUMP CASING GASKET SUITABLE FOR THE DESIGN TEMPERATURE AND

PRESSURE INSTALLED

- CAPTIVATE IMPELLER NUT WITH TACK WELD ON IMPELLER SHAFT

- NPT THREADS ON CASING DRAIN PLUG ARE NOT REQUIRED TO BE SEALED BECAUSE THE

SHIPYARD PROVIDED DRAIN EQUIPMENT WILL BE INSTALLED.

- REQUEST THE RECIRCULATION TUBE NPT THREADS BE SEALED WITH ANAEROBIC THREAD

SEALANT VICE TEFLON TAPE TO PREVENT TEFLON TAPE FLAKES INTERNAL TO THE

PUMPS

- VENDOR PROVIDE CERTIFICATE OF COMPLIANCE VERIFYING PUMP INTERNALS BE FREE

OF GREASE, OIL, FLUX, AND LOOSE FOREIGN MATERIAL (E.G. SHAVINGS, METAL BEADS,

TEFLON TAPE FLAKES, ETC.

- VENDOR PROVIDE CERTIFICATE OF COMPLIANCE VERIFYING THAT THE SUCTION AND

DISCHARGE FLANGE SEATING SURFACES COMPLY WITH THE FOLLOWING REQUIREMENTS

FOR JOINTS USING SPIRAL WOUND 150 PSI CLASS, MIL-G-24716A, TYPE 2, CLASS A

GASKETS:

1) GASKET SEALING AREA SHALL BE FREE OF NICKS, GOUGES, BURRS, DIRT, STEAM

CUTS, OR OTHER DEFECTS

2) SCRATCHES OF MEASUREABLE DEPTH IN THE GASKET SEALING AREA ARE

UNACCEPTABLE

3) ALL RAISED SURFACE DEFECTS ON THE FLANGE SEATING SURFACES ARE

UNACCEPTABLE

MFG / MFG P/N: CHEMPUMP G-SERIES PART NUMBER GC-3K-1S

QUANTITY: 7 EA

- CERTIFICATE OF COMPLIANCE REQUIRED -

Changes to specification or other technical requirements are not allowed without Shipyard approval via the Administrative Contracting Officer (ACO).

JOB ORDER

88MSM00001

KEY OP

KO ITEM

REV

IDN

8120-7208

IDN REV

PAGE OF

1 1