ORDERING DATA SHEET - GENERAL
PUMP SPECIFICATION
TECHNICAL REQUIREMENTS: (PER DRAWING 2301-3649, NOTE M5)
- CENTRIFUGAL IMPELLER
- CANNED ROTOR
- DRY STATOR CAVITY
- HERMETICALLY SEALED
- 300 SERIES STAINLESS STEEL PUMP CASE AND ROTOR
- DESIGN TEMPERATURE: 220°F
- DESIGN PRESSURE: 150 PSIG
- NPSH REQUIRED: <20 FEET
- HEAD PRESSURE: >75 FEET @ 30 GPM
- DISCHARGE CONNECTION: 1-1/2”, ASME B16.5, CLASS 150, RAISED FACE FLANGE
- SUCTION CONNECTION: 2”, ASME B16.5, CLASS 150, RAISED FACE FLANGE
- DIMENSIONAL ENVELOPE: 15-3/4” LONG X 9-3/4” WIDE X 21” HIGH
- VOLTAGE: 460 VAC, 3-PHASE
ADDITIONAL OPTIONS THAT MUST BE SPECIFIED TO THE VENDOR:
- INSTALLED PUMP ROTATION INDICATOR
- RUBBER PUMP CASING GASKET SUITABLE FOR THE DESIGN TEMPERATURE AND
PRESSURE INSTALLED
- CAPTIVATE IMPELLER NUT WITH TACK WELD ON IMPELLER SHAFT
- NPT THREADS ON CASING DRAIN PLUG ARE NOT REQUIRED TO BE SEALED BECAUSE THE
SHIPYARD PROVIDED DRAIN EQUIPMENT WILL BE INSTALLED.
- REQUEST THE RECIRCULATION TUBE NPT THREADS BE SEALED WITH ANAEROBIC THREAD
SEALANT VICE TEFLON TAPE TO PREVENT TEFLON TAPE FLAKES INTERNAL TO THE
PUMPS
- VENDOR PROVIDE CERTIFICATE OF COMPLIANCE VERIFYING PUMP INTERNALS BE FREE
OF GREASE, OIL, FLUX, AND LOOSE FOREIGN MATERIAL (E.G. SHAVINGS, METAL BEADS,
TEFLON TAPE FLAKES, ETC.
- VENDOR PROVIDE CERTIFICATE OF COMPLIANCE VERIFYING THAT THE SUCTION AND
DISCHARGE FLANGE SEATING SURFACES COMPLY WITH THE FOLLOWING REQUIREMENTS
FOR JOINTS USING SPIRAL WOUND 150 PSI CLASS, MIL-G-24716A, TYPE 2, CLASS A
GASKETS:
1) GASKET SEALING AREA SHALL BE FREE OF NICKS, GOUGES, BURRS, DIRT, STEAM
CUTS, OR OTHER DEFECTS
2) SCRATCHES OF MEASUREABLE DEPTH IN THE GASKET SEALING AREA ARE
UNACCEPTABLE
3) ALL RAISED SURFACE DEFECTS ON THE FLANGE SEATING SURFACES ARE
UNACCEPTABLE
MFG / MFG P/N: CHEMPUMP G-SERIES PART NUMBER GC-3K-1S
QUANTITY: 7 EA
- CERTIFICATE OF COMPLIANCE REQUIRED -
Changes to specification or other technical requirements are not allowed without Shipyard approval via the Administrative Contracting Officer (ACO).
JOB ORDER
88MSM00001
KEY OP
KO ITEM
REV
IDN
8120-7208
IDN REV
PAGE OF
1 1