PRINTED 1015/2016

· 4710 ALTN9A1

ITEM NO.

'·· ~~JU ....................... ···-······

SECTION B

STOCK NUMBER

4710-01-128-3500

CONTRACT

~· .. '~"~••••• • •••••• """""""""'"V __ _

ATTACHMENT J

ITEM NAME PIPE, CRES. 304, SEAMLESS, CLASS IV PIPE

SPECIAL CHARACTERISTICS

DIMENSIONS: CLASS IV

NPS: 8" SCHEDULE 120

C DESCRIPTION/SPECIFICATIONS

C.1 MANUFACTURE PER MIL..SPEC MIL-OTL-23226, PARAGRAPH

6.2 (ORDERING DATA):

PAGE L<>r3

(A) ''TUBE AND PIPE, CORROSION RESISTANT STEEL, SEAMLESS (UNS S30400, $30403, S34700, AND

S34800)", MIL-DTL-23226G OF 5 FEBRUARY 2008.

(B).COMPOSITION 304, TYPE 2 OR 3 UNLESS OTHERWISE SPECIFIED, CLASS, SIZE, SCHEDULE, ALLOWANCE FOR TYPE 1 AND QUANTITY SHALL BE AS SPECIFIED IN SECTION B OF THIS

SCHEDUU;.

(C) NITROGEN SHALL BE 0.10% MAXIMUM.

(D) FINISH (A), (B), (C), OR (E)

(E) NOT APPLICABLE.

(F) NOT APPLICABLE

(G} FOR CLASS IV PIPE WITH CLASS 1 DIMENSIONS, SEE SECTION B OF

THIS SCHEDULE. ADD SCHEDULE 140 COLUMN TO TABLE VI OF

MIL-DTL-23226 FOR 8" NPS AS FOLLOWS: 7.001" 1.D., .812" WALL

THICKNESS.

(H) INSIDE DIAMETER TOLERANCES APPLY FOR NOMINAL PIPE SIZES 1/2"

THRU 2'' IN LIEU OF OUTSIDE DIAMETER TOLERANCES.

(I) NOT APPLICABLE. ,

{J) CLASS IV LENGTHS PER PARAGRAPH 3.3.2.5(B) OF MIL-DTL-23226

EXCEPT MAXIMUM LENGTHS OF 20 FEET IN LIEU OF 24 FEET ARE PREFERABLE.

(K) NOT APPLICABLE.

{L) TRANSVERSE PROPERTIES ARE REQUIRED ON PIPE 8 INCHES AND LARGER IN DIAMETER.

(M) NOT APPLICABLE.

(N) MICROCLEANLINESS IS REQUIRED FOR TYPE 2 OR 3 PIPE.

(0) MATERIAL MARKING REQUIREMENTS OF SECTION 3.8 OF MIL-DTL-23226 AND THE

REQUIREMENTS OF C.4 BELOW.

(P) NOT APPLICABLE.

(Q) MIL-STD-2132D WITH NOTICE 1 IS THE REQUIRED REVISION FOR PERFORMANCE OF NON

DESTRUCTIVE TESTING.

C.2 THE CONTRACTOR SHALL NOTIFY PORTSMOUTH NAVAL SHIPYARD FOUR (4) WEEKS

IN ADVANCE QF ULTRASONIC TESTING TO ALLOW PARTICIPATION BY SHIP-

YARD PERSONNEL IN WITHNESSING UT TESTS. NOTIFY

CODE l\ \ 0 Tf;LEPHONE {207)438-....... )....,.'\_& _1 __

CONTRACT

PRINTED 1~/612016 ATIACHMENT

4710 ALTN9A1

C.3 DATA REQUIREMENTS:

C.3.1 MATERIAL CERTIFICATION, SEE EXHIBIT A, SEQUENCE A001

C.3.2 PROCEDURES (U.T.), SEE EXHIBIT A, SEQUENCEA002

C.3.3 PROCEDURES (ALLOY IDENT.), SEE EXHIBIT A, SEQUENCE A003

C.3.4 PROCEDURES (HEAT TREATMENT). SEE EXHIBIT A, SEQUENCE A004

C.3.5 PROCEDURES (LIQUID PENETRANT), SEE EXHIBIT A, SEQUENCE A005

C.4 MATERIAL MARKING .

1. EACH PIECE OF MATERIAL SHALL BE PERMANENTLY MARKED AT EACH

END WITH THE INFORMATION OF (A), (B), (C), AND (0) BELOW USING

THE PERMANENT MARKING METHODS OF MIL-STD-792F

OR THE PERMANENT MARKING METHOD SPECIFIED IN THE MATERIAL

SPECIFICATION.

(A) "SAE".

(B) VENDOR TRACEABILITY NUMBER TRACEABLE TO ALL MANUFACTURE

TEST AND INSPECTION INFORMATION AND TO A UNIQUE SET OF

. PHYSICAL, MECHANICAL, AND CHEMICAL TEST RESULTS WHICH REPRESENT

THE MATERIAL USED l'O MAKE THE PIECE.

(C) THE MANUFACTURER'S NAME, TRADE-MARK OR SYMBOL.

(D} THE NATIONAL STOCK NUMBER (1H 4710-01-128-3500 X2}. INFORMATION REQUIRED BY THE SPECIFICATION IN ADDITION TO THAT REQUIRED BY (A), (B), (C}, AND (D) ABOVE SHALL BE

MARKED EITHER PER THE SPECIFICATION OR PER PERMANENT MARKING METHODS OF

MIL-ST0-792F. MATERIAL DESIGNATOR LISTED IN THE SPECIFICATION NEED NOT BE MARKED ON

MATERIAL IF IT IS DIFFERENT FROM THAT SPECIFIED BY (A) ABOVE.

2. IF ANY MARKING SPECIFIED ABOVE CANNOT BE APPLIED DUE TO

SPACE LIMITATION, A WAIVER REQUEST SHALL BE SUBMITTED.

C.5 C528 SPECIFICATION CHANGES

C.6 C500 MERCURY CONTROL

D PRESERVATION/PACKAGING/PACKING

D.1 PACKING REQUIREMENTS: PARAGRAPH 5.2 OF MIL-DTL-23226G

APPLIES. IN ADDITION, MATERIAL SHALL BE SHIPPED IN WOODEN BOXES.

E INSPECTION ACCEPTANCE

E.1 ES INSPECTION AND ACCEPTANCE (SPECIAL QC ITEMS)

E.2 E506 HIGHER-LEVEL CONTRACT QUALITY REQUIREMENTS

(MIL-1-45208 OR MIL-Q-9858 OR 1$0 900119002 WITH STR-ISO 9000 SUPPLEMENT A OR B OR C}

· E.3 G504 DCMC APPROVAL OF NONCONFORMING MATERIAL -WITHHELD

E.4 G505 VENDOR DISPOSITION OF NONCONFORMING MATERIAL

E.5 FAR 52.246-2 INSPECTION OF SUPPLIES-FIXED-PRICE (AUG 1996)

H SPECIAL PROVISIONS

SEE BASIC PART OF CONTRACT FOR APPLICABILITY

K Section

CONTRACT

•••••••••••••""""""'-'"'''~'"no•••••••

''PRINTED 10/5/2016 ATTACHMENT J

4710 ALTN9A1

t Section

SEE BASIC PART OF CONTRACT FOR APPLICABILITY

M Section

SEE BASIC PART OF CONTRACT FOR APPLICABILITY

j