RFQ_16-T-0232_Vac_Recovery_Units.doc
DOC document 49 KB Posted
- Attached to
- Vacuum Recovery Unit Rental Federal contract opportunity
- Solicitation number
- N39040-16-T-0232
About this file
This is the RFQ form
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFQ Form
N3904016T0232
THIS IS NOT AN ORDER
PLEASE PROVIDE DELIVERED PRICES, AVAILABILITY, AND PRICE SOURCE WITH QUOTE
REFERENCE # N39040-16-T-0232
DUE DATE: 7/8/2016 2:00 pm EST From: PORTSMOUTH NAVAL SHIPYARD
Your company info:
Christina.Allaire@navy.mil
TO:
CONTRACTING, CODE 410
ATTN:
PORTSMOUTH, NH 03801-2590
(P)
PHONE: 207-438-2189
Email:
FAX: (207) 438-4193
Cage Code:
BUSINESS SIZE: SMALL LARGE
PAYMENT TERMS ______%______DAYS
DELIVERY TIME: ____________ARO
PRICES DERIVED FROM (CHECK ONE)
F.O.B. DESTINATION, Y____N____
___COMMERCIAL PRICE LIST DATED
IF NO, SHIPPING COST__________.
___INTERNAL PRICE LIST DATED
___OTHER (PLEASE EXPLAIN)
Please indicate your preferred payment method by checking one of the options below. Payment options available are WAWF and GCPC: Government Commercial Purchase Card (up to $100,000). Please ensure that you register for WAWF (www.wawftraining.com)
GCPC_____ WAWF (Wide Area Workflow) _____ *Please note that purchase card orders are not paid up front. Once material is received, a Government cardholder may be contacted for purchase card information.
__X_ If checked, to be awarded on an “All or None” basis, PPIRS evaluation procedures apply.
YOUR SIGNATURE___________________________________DATE_____________
| ITEM |
| DESCRIPTION |
| QTY |
| Unit |
| Unit Price |
| Total |
| 0001 |
| Rental of one (1) Vacuum Recovery Unit |
IAW Specifications on Page 2
| 40.5 |
| Weeks |
Period Of Performance is: 07/11/2016 to 04/20/2017
DELIVERY TO: Portsmouth Naval Shipyard (PNS), Kittery, Maine Specifications:
· 200 HP Vacuum Recovery Unit
· Minimum 4,600 CFM blower size
· Greater than 27 Static rating
· 8” Vacuum Inlet
· Maximum dimensions of 15’ X 7’ X 10”
· Max weight 11,000 LBS
· 460V 3-Phase 400 AMP 60 Hz
· Secondary filtration
· Less than 85 dpa during operation
· Include phase monitor to protect power
· All electric motors shall be totally enclosed
· Skid mount with forklift pockets
· Lifting eyes with lifting/handling diagrams
· Automatic dust discharge
· HEPA Filters
· Any additional requirements listed on the attached Inspection Checklist
File details come from the government source that posted it. Updated .