RFC 1.docx
DOCX document 17 KB Posted
- Attached to
- USNS APACHE (T-ATF 172) Deactivation Federal contract opportunity
- Solicitation number
- N3220522R0003
About this file
This document contains three requests for clarification relating to a solicitation for the deactivation of the USNS APACHE (T-ATF 172).
The clarification requests relate to physical security requirements at a private contractor facility, pricing for towing the vessel 207 nautical miles from a shipyard facility in Baltimore to the inactive reserve fleet in Philadelphia over five days, and arrangements for the contractor to provide and subsequently return two P-100 pumps used in towing preparations. The Navy seeks confirmation that the contractor will be responsible for establishing and maintaining increased force protection conditions at its facility and transporting the vessel as specified, clarifying that the pumps must be returned after use.
The solicitation is being conducted by the Department of the Navy's Military Sealift Command for deactivation of the USNS APACHE. No further details are provided on response dates, pricing terms, set-asides or other requirements.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N3220522R0003-0006.pdf | ||
| N3220522R0003-0005.docx | DOCX document | |
| N3220522R0003-0004.docx | DOCX document | |
| N3220522R0003-0003.docx | DOCX document | |
| RFC 3.docx | DOCX document | |
| N3220522R0003-0002.docx | DOCX document | |
| RFC 2.docx | DOCX document | |
| N3220522R0003-0001.docx | DOCX document | |
| J-7 MSC Ship Repair Facility Survey.docx | DOCX document | |
| J-8 Request for Spec Clarification.docx | DOCX document | |
| J-12 Past Performance Data.docx | DOCX document | |
| J-9 Disclosure of Lobbying Activities SF-LLL.docx | DOCX document | |
| J-2 Category A Items.xlsx | XLSX spreadsheet | |
| J-10 Interport Differential.docx | DOCX document | |
| J-13 Past Performance Questionnaire.docx | DOCX document | |
| N3220522R0003 Solicitation.pdf | ||
| J-14 Technical Data Non-Disclosure.docx | DOCX document | |
| J-3 Category B Item.xlsx | XLSX spreadsheet | |
| Exhibit A - CDRLS.pdf |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USNS APACHE (T-ATF 172) Deactivation N3220522R0003
REQUEST FOR SPECIFICATION CLARIFICATION #1
SPECIFICATION ITEM NO.: 0025
PARAGRAPH / SECTION NO:____________________
TITLE: Physical Security at Private Contractor Facility
QUESTION: Work item is Category B continuation of service but there is no Category A item for Physical Security. Please clarify.
ANSWER: Category B WI 0025 is not for continuation of services, it is for establishing and maintaining the shipyard’s force protection (FP) posture from BRAVO to CHARLIE and CHARLIE to DELTA. Additionally, the contractor shall provide a per-day rate to maintain FP Conditions above Condition BRAVO.
REQUEST FOR SPECIFICATION CLARIFICATION #2
SPECIFICATION ITEM NO.: 0050, 0051
PARAGRAPH / SECTION NO:____________________
TITLE: ___________________________
QUESTION: Please clarify if it should be priced for 207 (KN) miles or for milage from shipyard
| 3.1 | Location |
| 3.1.1 | Departure – Shipyard facility |
| 3.1.2 | Destination – INACTSHIPS Philadelphia |
| 3.2 | Quantity |
| 3.2.1 | Approximate distance: 207 (KN) miles |
| 3.2.2 | Approximate duration: Five (5) Days |
ANSWER: See revised WI 0050 and 0051.
REQUEST FOR SPECIFICATION CLARIFICATION #3
SPECIFICATION ITEM NO.: 050
PARAGRAPH / SECTION NO: Paragraph 7.4.19 TITLE: Towing Preparations
QUESTION: Will the two P-100 pumps be returned after the tow is completed or does the government want to keep the pumps, like the towing bridles?
ANSWER: The contractor is to provide the pumps for the tow and arrange for their return to the contractor.