RFC_19-20.docx
DOCX document 27 KB Posted
- Attached to
- USNS COMFORT (T-AH 20) Mid-Term Availability Federal contract opportunity
- Solicitation number
- N3220518R4554
About this file
RFC 19 and 20
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N3220518R4554-0005.docx | DOCX document | |
| N3220518R4554-0004.docx | DOCX document | |
| N3220518R4554-0003.docx | DOCX document | |
| RFC_18.docx | DOCX document | |
| N3220518R4554-0002.docx | DOCX document | |
| RFC_17_Answered.docx | DOCX document | |
| RFC_1-16_-_Answered.docx | DOCX document | |
| N3220518R4554-0001.docx | DOCX document | |
| J-3_Category_B_Items.xlsx | XLSX spreadsheet | |
| J-Attachments.zip | ZIP file | |
| Justification_and_Approval_N104-18-R-4554_Redacted.pdf | ||
| N3220518R4554.docx | DOCX document |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N3220518R4554
USNS COMFORT (T-AH 20) MTA
REQUEST FOR SPECIFICATION CLARIFICATION
SPECIFICATION ITEM NO.: ____707_________________
PARAGRAPH / SECTION NO:__7.6.1.1, 7.7.2__________________
TITLE: ___Preservation of Laundry Space__________
QUESTION:
Paragraph 7.6.1.1 is to PTC SP-3 two (2) square feet Paragraph 7.7.2 for coating is for 4,000 square feet How much PTC-SP-3 are we to accomplish?
ANSWER:
4,000 sq feet is to be prepared to SSPC SP3 and coated and 4,000 sq feet is to be prepared to SSPC SP1 and coated. 8,000 sq feet total. Work item has been revised to reflect same.
Photos of laundry have been added to paragraph 8 of the work item to assist with scoping.
REQUEST FOR SPECIFICATION CLARIFICATION
SPECIFICATION ITEM NO.: _____602________________
PARAGRAPH / SECTION NO:_____7.1.1_______________
TITLE: ___Lifeboat Davits Falls Replacement__________
QUESTION:
This questions was asked once before & we were given the answer “OEM, Lake Shore, can provide the details of the falls per their part numbers specificed in the davit technical manual which was provided as reference 2.1.1 of this work item”. We looked in the technical manual, as directed by the item (per reference 2.1.1, Table 2-1 Reference Data) and did not find the information that was originally requested, nor was there a part number listed. All Table 2-1 tells us is 7/8” diameter, 6x19, preformed, regular lay, prelubricated, IWRC with a mimimum breaking point and the lengths of the forward & after fall. None of this information answers our original question. Also, please note, that the OEM, Lake Shore has taken exception to providing the falls.
ORIGINAL QUESTION
The note in this paragraph recommends purchasing the falls pre-assembled with spelter socket. Is the socket open or closed? One end or both ends of the falls?
ANSWER:
Reference 2.1.1 of the work item states “2-2.4 BOAT FALLS. The boat falls are made up of 7/8 inch diamter, (6x19), preformed, regular lay, pre-lubricated, I.W. R.C. wire rope with a breaking strength of 69,200 pounds. An 1-1/4 inch by 12 inch turnbuckle with a closed spelter socket is attached to the inboard end of the trackway for taking up slack. The forward fall is 265 feet long and the aft fall is 300 feet long.”
ATTACHMENT J - 8