RFC_19-20.docx

DOCX document 27 KB Posted

Attached to
USNS COMFORT (T-AH 20) Mid-Term Availability Federal contract opportunity
Solicitation number
N3220518R4554
Issued by
Department of the Navy Military Sealift Command

About this file

RFC 19 and 20

View the file

Other files for this federal contract opportunity

Other files attached to USNS COMFORT (T-AH 20) Mid-Term Availability, newest first.
File Type Posted
N3220518R4554-0005.docx DOCX document
N3220518R4554-0004.docx DOCX document
N3220518R4554-0003.docx DOCX document
RFC_18.docx DOCX document
N3220518R4554-0002.docx DOCX document
RFC_17_Answered.docx DOCX document
RFC_1-16_-_Answered.docx DOCX document
N3220518R4554-0001.docx DOCX document
J-3_Category_B_Items.xlsx XLSX spreadsheet
J-Attachments.zip ZIP file
Justification_and_Approval_N104-18-R-4554_Redacted.pdf PDF
N3220518R4554.docx DOCX document
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N3220518R4554

USNS COMFORT (T-AH 20) MTA

REQUEST FOR SPECIFICATION CLARIFICATION

SPECIFICATION ITEM NO.: ____707_________________

PARAGRAPH / SECTION NO:__7.6.1.1, 7.7.2__________________

TITLE: ___Preservation of Laundry Space__________

QUESTION:

Paragraph 7.6.1.1 is to PTC SP-3 two (2) square feet Paragraph 7.7.2 for coating is for 4,000 square feet How much PTC-SP-3 are we to accomplish?

ANSWER:

4,000 sq feet is to be prepared to SSPC SP3 and coated and 4,000 sq feet is to be prepared to SSPC SP1 and coated. 8,000 sq feet total. Work item has been revised to reflect same.

Photos of laundry have been added to paragraph 8 of the work item to assist with scoping.

REQUEST FOR SPECIFICATION CLARIFICATION

SPECIFICATION ITEM NO.: _____602________________

PARAGRAPH / SECTION NO:_____7.1.1_______________

TITLE: ___Lifeboat Davits Falls Replacement__________

QUESTION:

This questions was asked once before & we were given the answer “OEM, Lake Shore, can provide the details of the falls per their part numbers specificed in the davit technical manual which was provided as reference 2.1.1 of this work item”. We looked in the technical manual, as directed by the item (per reference 2.1.1, Table 2-1 Reference Data) and did not find the information that was originally requested, nor was there a part number listed. All Table 2-1 tells us is 7/8” diameter, 6x19, preformed, regular lay, prelubricated, IWRC with a mimimum breaking point and the lengths of the forward & after fall. None of this information answers our original question. Also, please note, that the OEM, Lake Shore has taken exception to providing the falls.

ORIGINAL QUESTION

The note in this paragraph recommends purchasing the falls pre-assembled with spelter socket. Is the socket open or closed? One end or both ends of the falls?

ANSWER:

Reference 2.1.1 of the work item states “2-2.4 BOAT FALLS. The boat falls are made up of 7/8 inch diamter, (6x19), preformed, regular lay, pre-lubricated, I.W. R.C. wire rope with a breaking strength of 69,200 pounds. An 1-1/4 inch by 12 inch turnbuckle with a closed spelter socket is attached to the inboard end of the trackway for taking up slack. The forward fall is 265 feet long and the aft fall is 300 feet long.”

ATTACHMENT J - 8