SOW_for_USNS_CHARLES_DREW.docx
DOCX document 42 KB Posted
- Attached to
- MHE Service Federal contract opportunity
- Solicitation number
- N3220518Q4754
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Technical_Exhibit_1.__Safety_Certification_Requirements;_MHE.docx | DOCX document | |
| Technical_Exhibit_4.__Maintenance_Service_Requirements;_AWP.docx | DOCX document | |
| Technical_Exhibit_3.__Maintenance_Service_Requirements;_Diesel_Forklift.docx | DOCX document | |
| Limited_Source_CHARLES_DREW-REDACTED_Redacted.pdf | ||
| COMBINED_SYNOPSIS_SOLICITATION.CHARLES_DREW.docx | DOCX document | |
| Aerial_Work_Platform_(AWP)_Safety_Certification_Form..doc | DOC document | |
| Technical_Exhibit_2.__Maintenance_Service_Requirements;_Electric_Forklift.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Reference: (a). NAVSEA SW0-23-AH-WHM-10 Eight Revision, “Handling Ammunition and Explosives with industrial Material Handling Equipment (MHE) (b). NAVSUP Publication 538 Sixth Revision, “Management of Material Handling Equipment (MHE) and Shipboard Mobile Support Equipment (SMSE)
| Attachments: | (1). Technical Exhibit 1. Safety Certification Requirements | |
| (2). Technical Exhibit 2. Maintenance Service Requirements; Electric Forklift | ||
| (3). Technical Exhibit 3. Maintenance Service Requirements; Diesel Forklift |
(4). Technical Exhibit 4. Maintenance Service Requirements; AWP (5). Aerial Work Platform (AWP) Safety Certification Form.
1. Purpose: In accordance with ref (a) and (b), a quote is requested to provide Materials Handling Equipment (MHE) service and support to include an open/inspection, repairs, services, and/or materials. The following information and requirements are hereby provided for planning and pricing purposes. Submission of “Price & Availability Feedback” does not constitute a guarantee of purchase, service contract, or delivery order.
2. Vessel: USNS CHARLES DREW
3. Location of Equipment/Services: VIGOR ISLAND SHIPYARD - PORTLAND, OR
4. Period of Performance: 28 MAR 2018 to 13 MAY 2018
5. Statement of Work (SOW): The following work items shall be accomplished by the selected service provider (contractor) in conjunction with this repair and maintenance requirement. The Government intends to award a Fixed Price Contract to the selected service provider:
a. Services to MHE identified in Tables 1 and 2, below, will be performed at the Contractor’s maintenance facility. The Contractor’s quote shall specify the proposed location of the service and provide a summary of the proposed process for maintenance, repairs, and safety recertification.
b. If the service provider is capable of arranging transportation of the MHE assets to/from the service provider’s facility, the quote may include a separate line entry for transportation of the assets. If the service provider is unable to arrange transportation, the quote shall specify this and request the Government arrange transportation
c. Contractor shall perform a periodic maintenance service on all units identified in Table 1.
The maintenance shall be completed in accordance with the requirements Identified in Technical Exhibits 2 and 3.
d. Contractor shall perform an operational evaluation and weight test on the ordnance-handling manual pallet trucks identified in Table 2.
e. Contractor shall complete a safety certification on all units identified in Table 1 and 2. The safety certification shall be completed in accordance with the requirements set forth in NAVSEA Manual SW023-AH-WHM-010 reference (a) and Technical Exhibit 1.
f. Contractor shall complete a fork inspection on all units identified in Table 1 in accordance with the Fork Maintenance Inspection Procedures listed in NAVSUP Pub 538 reference (b).
g. Contractor shall perform a periodic maintenance service on the aerial work platform (AWP) identified in Table 2 in accordance with manufacturer recommendations.
h. Contractor shall complete a safety certification and weight test on the aerial work platform (AWP) listed in Table 2 in accordance with the requirements set forth in reference (b). Refer to NAVSUP P-538, 6th edition, para 8-7.6 and figure 8-16.
i. Contractor shall perform an operational inspection and a periodic maintenance service on the ordnance handling trailers identified in Table 2 in accordance with manufacture recommendations.
j. Contractor shall remove, and inspect the counterweight, mounting bolt, and the base plate threads for wear on all shipboard diesel forklifts to include removing the bolt, and counter weights for inspection of rust, corrosion, and worn threads on the bolts, and threaded base plate surface. Contractor shall reinstall the counterweight, and mounting bolts that are within SAE standards, and re-torque the counterweight bolts to 410 foot pounds, or replace the bolts, and rethread the base plates that fail the visual inspection, as required.
k. Contractor shall provide a condition report on each unit identified in Table 1 through 2. All condition reports shall contain, at the minimum, the ship's name, the MSC MHE serial number, manufacture identification number, make and model, a complete list of recommended repairs and services, and all associated pricing information.
6. Equipment to be serviced:
USNS CHARLES DREW - TABLE 1
| MANUFACTURER |
| MODEL |
| MSC NUMBER |
| SERIAL NUMBER |
| TYPE/SAFETY |
| HYSTER |
| E40XM |
| 2302083 |
| G108N09515F |
| STD ELEC |
| HYSTER |
| E40XM |
| 2302507 |
| G108N11986G |
| STD ELEC |
| HYSTER |
| E40XM |
| 2302508 |
| G108N11191G |
| STD ELEC |
| HYSTER |
| E40XM |
| 2302509 |
| G108N11200G |
| STD ELEC |
| HYSTER |
| E40XM |
| 2302510 |
| G108N11193G |
| STD ELEC |
| HYSTER |
| E60XM |
| 2302511 |
| G108N11362G |
| STD ELEC |
| HYSTER |
| E60XM |
| 2302512 |
| G108N11400G |
| STD ELEC |
| HYSTER |
| E60XM |
| 2302513 |
| G108N11401G |
| STD ELEC |
| HYSTER |
| E60XM |
| 2302514 |
| G108N11398G |
| STD ELEC |
| HYSTER |
| E60XM |
| 2302515 |
| G108N11342G |
| STD ELEC |
| HYSTER |
| E60XM |
| 2302516 |
| G108N11469G |
| STD ELEC |
| HYSTER |
| E100Z |
| 2302517 |
| E098N02381G |
| STD ELEC |
| HYSTER |
| E100Z |
| 2302518 |
| E098N02368G |
| STD ELEC |
| HYSTER |
| E100Z |
| 2302519 |
| E098N02369G |
| STD ELEC |
| HYSTER |
| E100Z |
| 2302520 |
| E098N02380G |
| STD ELEC |
| HYSTER |
| S60FTG |
| 2302175 |
| F187G12052F |
| STD DIES |
| HYSTER |
| S60FTG |
| 2302521 |
| F187G15367G |
| STD DIES |
| HYSTER |
| S60FTG |
| 2302522 |
| F187G15368G |
| STD DIES |
| HYSTER |
| S60FTG |
| 2302523 |
| F187G15369G |
| STD DIES |
| HYSTER |
| S60FTG |
| 2302524 |
| F187G15376G |
| STD DIES |
| HYSTER |
| S60FTG |
| 2302525 |
| F187G15399G |
| STD DIES |
| HYSTER |
| S60FTG |
| 2302526 |
| F187G15405G |
| STD DIES |
| HYSTER |
| S60FTG |
| 2302527 |
| F187G15502G |
| STD DIES |
| HYSTER |
| S60FTG |
| 2302528 |
| F187G15476G |
| STD DIES |
| HUBTEX |
| VQ 45/4 |
| 2900095 |
| 62063 |
| MSL |
| HUBTEX |
| VQ 45/4 |
| 2900096 |
| 62064 |
| MSL |
| HUBTEX |
| VQ 45/4 |
| 2900097 |
| 62065 |
| MSL |
USNS CHARLES DREW - TABLE 2
| MANUFACTURER |
| MODEL |
| MSC NUMBER |
| SERIAL NUMBER |
| TYPE |
| WESLEY INT'L |
| 42-27-60XTSB |
| 28-00065 |
| 05Y10251 |
| PALLET TRUCK |
| WESLEY INT'L |
| 42-27-60XTSB |
| 28-00066 |
| 05Y10252 |
| PALLET TRUCK |
| WESLEY INT'L |
| 42-27-60XTSB |
| 28-00067 |
| 05Y10253 |
| PALLET TRUCK |
| WESLEY INT'L |
| 42-27-60XTSB |
| 28-00068 |
| 05Y10254 |
| PALLET TRUCK |
| WESLEY INT'L |
| 42-27-60XTSB |
| 28-00069 |
| 09Y9216 |
| PALLET TRUCK |
| WESLEY INT'L |
| 42-27-60XTSB |
| 28-00070 |
| 09Y9217 |
| PALLET TRUCK |
| WESLEY INT'L |
| 42-27-60XTSB |
| 28-00071 |
| 09Y9218 |
| PALLET TRUCK |
| GENIE |
| Z-45/25J IC |
25-00011
Z452509A-39104
BOOM, ARM LIFT
| ENTWISTLE |
| EJ-42338 |
| 2903043 |
| 62202-50 |
| 10K |
| ENTWISTLE |
| EJ-42338 |
| 2903044 |
| 62202-53 |
| 10K |
| ENTWISTLE |
| EJ-42338 |
| 2903045 |
| 62292-72 |
| 10K |
| ENTWISTLE |
| EJ-42338 |
| 2903046 |
| 62292-73 |
| 10K |
7. Deliverables:
The contractor shall provide:
(1). A Condition Report for each unit listed in Table 1 through 3. The condition reports will be provided to the MHE Program Manager at MSC Norfolk (N48) within 5 days of receipt of MHE. A copy of the condition reports will be provided to the ship’s Master or his designated representative upon request.
(2). A complete and signed MHE Safety Certification Form for each unit listed in table 1 and 2. The original signed forms shall be provided to the ship's Master or his designated representative. A copy of the signed forms shall be provided to the MSC Norfolk MHE Program Management office.
(3). A complete and signed Fork Inspection Form for each unit listed in Table 1. The original signed forms shall be provided to the ship's Master or his designated representative. A copy of the signed forms shall be provided to the MSC Norfolk MHE Program Management office.
(4). A complete and signed safety certification form for the aerial work platform (AWP) listed in Table 2. The original signed forms shall be provided to the ship's Master or his designated representative. A copy of the signed forms shall be provided to the MSC Norfolk MHE Program Management office.
(5). A completed MHE or AWP (as appropriate) Safety Certification Marking stenciled or affixed to each unit listed in Tables 1 through 2 (in accordance with the requirements listed in the NAVSUP P-538).
(6). A condition report on all batteries removed from the electric forklifts listed in Table 1.
(7). A completion report on all battery cables installed.
8. Qualifications. The selected service provider/contractor must meet the following qualifications:
a. All management and technical personnel performing above listed services must be able to demonstrate the following:
- Experience performing safety certifications on shipboard-approved MHE in accordance with the requirements set forth in the NAVSEA SW023-AH-WHM-010, NAVSUP PUB 538, and equipment technical manuals.
- Experience interpreting, trouble-shooting, and resetting HYSTER on-board dash displays.
b. Contractor personnel performing repairs and maintenance onboard MSC vessels shall abide by all DOD, Navy, and MSC security requirements and clearance procedures required to access U.S. Government facilities and MSC vessels.
c. Proof of U.S. citizenship shall be provided in order to enter a U.S. military facility, if requested by the Government. When accessing US Government installation, proposed contractor personnel shall be vetted by the Government through the Government's El Paso Intelligence Center (EPIC) before accessing the Government installation
d. The contractor must be able to perform the required services within the period of performance identified in the Statement of Work.
9. Technical Points of Contact (POCs):
- POC: Tangya Ragin – tangya.ragin.ctr@navy.mil
- Alternate POC: Robert Hall - Robert.m.hall1.ctr@navy.mil
10. Shipboard Points of Contact (POC):
| CHARLES DREW Chief Engineer: | |
| Clayton Koshmerl | |
| Email: clayton.c.koshmerl.civ@ake10.navy.mil (and/or) | |
| cheng@ake10.navy.mil | |
| Ship phone: 619-533-7273 / 619-533-7274/ Radio: 619-744-1283 |
| CHARLES DREW Principal Port Engineer: | ||
| Joe Martin | ||
| Email: | joseph.s.martin@navy.mil | |
| Office: | 757-777-6780 |
| CHARLES DREW Supply Officer: | |
| Christopher Jenkins | |
| Email: christopher.l.jenkins.civ@ake10.navy.mil |
File details come from the government source that posted it.