Attachment_3_-_Lodging_Requirement_Checklist.docx
DOCX document 17 KB Posted
- Attached to
- USNS APACHE CIVMAR Lodging in Charleston, SC Federal contract opportunity
- Solicitation number
- N32205-18-Q-0170
About this file
Attachment 3 Lodging Requirement Checklist
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| COMBINED_SYNOPSIS_SOLICITATION_APACHE.doc | DOC document | |
| Attachment_1_-_Quote_Cover_Letter.doc | DOC document | |
| Attachment_4_-_PWS_USNS_APACHE_CIVMAR_LODGING_REQUIREMENTS.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 3: Lodging Requirement Checklist Directions: Advise how the PWS requirement will be met in the column provided. If you are unable to meet a requirement in the solicitation, please provide reason in the bottom section. Failure to provide the information as to how the requirement will be met will result in the technical package being found unacceptable. Any requirement that cannot be met will find the technical package unacceptable.
| PWS Requirement |
| Advise how the requirement will be met |
Hotel is a AAA 3 Diamond or higher rated extended stay hotel (provide a copy of the AAA rating)
Studio room must have at least one queen size (or larger) bed, with nightstand/lamp
Studio room must have distinguishable living and sleeping areas
Studio room must have a seating area
Studio room must have a minimum of a four drawer dresser
Studio room must have a full size closet space
Kitchenette must be complete with cooking utensils (cookware, dish service for 4, silverware for 4, basic cooking utensils (can opener, toaster, coffee maker, etc.)
Kitchenette must have dish cleaning supplies (i.e. drain rack, dish soap, sponge, paper towels), with cabinetry for storage of dishware, as well as dry food storage
Kitchenette must have a mounted microwave with exhaust fan
Kitchenette must have a full size refrigerator/freezer with separate freezer compartment (minimum 14 cu. ft.)
Kitchenette must have a built in stove top, with at least 2 burners (not a plug in appliance) (a full size stove/oven with at least 2 burners is also acceptable)
Kitchenette must have a table in eating area, with at least two (2) chairs
Multiple functional onsite washers and dryers must be available (2 or more of each)
Room must include occupant controllable thermostat
Complimentary hotel internet access must be available in each room, and hotel guests must have access to an on-site Business Center
Hotel shall provide free local calls.
Hotel shall incorporate the cost of parking in the room rate
Hotel rooms shall include daily cleaning, changing of linens, and replenishment of toiletries.
Facility shall not be under construction or major renovation during the performance period.
Facility must be listed on the current Hotel-Motel National Master List as required by PL101-391, Must provide a copy of the listing
Travel to/from hotel to shipyard location should not include travel via tunnel
Security cameras must be positioned at hotel entry/exit points and lobby area.
Facility must have emergency battery lighting on stairwells, lobby areas, common areas, and hallways.
Facility must be within a 20 mile driving distance of Detyens shipyards, 1670 Drydock Ave, North Charleston, SC 29405using www.mapquest.com website (provide copy of route showing distance)
Exceptions - If you are unable to meet any requirement in the solicitation, please provide reason:
File details come from the government source that posted it.