SOW_CHAMBERS-KANAWHA_V003.docx

DOCX document 33 KB Posted

Attached to
Forklift Safety Certification and Preventive Maintenance Federal contract opportunity
Solicitation number
N32205-17-Q-7062
Issued by
Department of the Navy Military Sealift Command

About this file

Statement of work

View the file

Other files for this federal contract opportunity

Other files attached to Forklift Safety Certification and Preventive Maintenance, newest first.
File Type Posted
WASHINGTON_CHAMBERS_TECHNICALEXHIBIT1_SafetyCertification.docx DOCX document
WASHINGTON_CHAMBERS_TECHNICALEXHIBIT2_ElectricForklift.docx DOCX document
WASHINGTON_CHAMBERS_TECHNICALEXHIBIT3_DieselForklift.docx DOCX document
SOW_WASHINGTON_CHAMBERS_V003.docx DOCX document
SOLE_SOURCE_CHAMBERS-KANAWHA_V003_MOD_1.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work (SOW): The following work items shall be accomplished by the selected service provider (contractor) in conjunction with this repair and maintenance requirement. The Government intends to award a Fixed Price Contract to the selected service provider:

a. Contractor shall conduct training and instruction for up to three (3) crewmembers in the procedures required to test and certify all onboard Material Handling Equipment (MHE) – and associated equipment – in accordance with the procedures and requirements set forth in references (a) and (b).

b. Contractor shall conduct training and instruction for up to three (3) crewmembers in the maintenance and repair procedures associated with the successful completion of periodic maintenance, repairs, and safety certifications of all equipment listed in Tables 1 through 2, below.

c. Contractor shall perform all certification, maintenance and repair actions to MHE identified in Table 1 - in accordance with the requirements set forth in attachments 1 through 3 and 5 (technical exhibits) – that are beyond the skill level/manpower availability of the ship’s crew members but within the scope of repairs that can be adequately accomplished onboard the vessel (i.e. without removing the MHE from the ship). Contractor shall staff and equip the service with the capability to perform all actions without assistance from ship’s personnel.

d. Contractor shall perform all certification, maintenance and repair actions to Aerial Work Platforms (AWP)/10K Trailer/Pallet Jack identified in Table 2 - in accordance with the requirements set forth in NAVSUP P-538 and associated vehicle Technical Manuals – that are beyond the skill level/manpower availability of the ship’s crew members but within the scope of repairs that can be adequately accomplished onboard the vessel (i.e. without removing the AWP from the ship). Contractor shall staff and equip the service with the capability to perform all actions without assistance from ship’s personnel.

e. Contractor shall conduct training for up to three (3) crewmembers in the use and maintenance of installed electric forklift battery chargers. Contractor shall oversee or perform an operational check on all battery chargers listed in table 3 to ensure proper operation, voltage, and amperage settings. Contractor shall reset battery chargers, as required.

f. Contractor shall guide ship’s crew in the performance of basic corrosion control on all MHE utilizing appropriate wire brush and spot painting techniques. Contractor shall perform corrosion control that is beyond the capability/available manpower of ship’s personnel. Approved spot paint includes “Rust-Oleum brand” Enamel Gray Primer (V2182838), Black Rust Reformer (215634), Equipment Yellow Paint (V2148838), and Gloss Black paint (V2179838).

7. Equipment to be serviced:

USNS WASHINGTON CHAMBERS - TABLE 1

MANUFACTURER
MODEL
MSC NUMBER
SERIAL NUMBER
TYPE/SAFETY
HYSTER
E40ZG
2302082
G108N09514F
STD ELEC
HYSTER
E60ZG
2302130
G108N09176F
STD ELEC
HYSTER
E40ZG
2302529
G108N11329G
STD ELEC
HYSTER
E40ZG
2302530
G108N11331G
STD ELEC
HYSTER
E40ZG
2302531
G108N11321G
STD ELEC
HYSTER
E60ZG
2302532
G108N11336G
STD ELEC
HYSTER
E60ZG
2302533
G108N11471G
STD ELEC
HYSTER
E60ZG
2302534
G108N11474G
STD ELEC
HYSTER
E60ZG
2302535
G108N11480G
STD ELEC
HYSTER
E60ZG
2302536
G108N11399G
STD ELEC
HYSTER
E60ZG
2302537
G108N11436G
STD ELEC
HYSTER
E60ZG
2302538
G108N11465G
STD ELEC
HYSTER
E100Z
2302539
E098N02444G
STD ELEC
HYSTER
E100Z
2302540
E098N02445G
STD ELEC
HYSTER
E100Z
2302541
E098N02450G
STD ELEC
HYSTER
E100Z
2302542
E098N02451G
STD ELEC
HYSTER
S60FTG
2302543
F187G15960H
STD ELEC
HYSTER
S60FTG
2302544
F187G15961H
STD ELEC
HYSTER
S60FTG
2302545
F187G15962H
STD ELEC
HYSTER
S60FTG
2302546
F187G15965H
STD ELEC
HYSTER
S60FTG
2302547
F187G15971H
STD ELEC
HYSTER
S60FTG
2302548
F187G15976H
STD ELEC
HYSTER
S60FTG
2302549
F187G15979H
STD ELEC
HYSTER
S60FTG
2302550
F187G15980H
STD ELEC
HUBTEX
VQ 45/4
2900098
62071
ELEC SIDELDR
HUBTEX
VQ 45/4
2900099
62072
ELEC SIDELDR
HUBTEX
VQ 45/4
2900100
62073
ELEC SIDELDR

USNS WASHINGTON CHAMBERS - TABLE 2

MANUFACTURER
MODEL
MSC NUMBER
SERIAL NUMBER
TYPE
WESLEY INT'L
42-27-60XTSB
28-00073
05Y10256
PALLET TRUCK
WESLEY INT'L
42-27-60XTSB
28-00074
05Y10255
PALLET TRUCK
WESLEY INT'L
42-27-60XTSB
28-00075
05Y10257
PALLET TRUCK
WESLEY INT'L
42-27-60XTSB
28-00076
05Y10258
PALLET TRUCK
WESLEY INT'L
42-27-60XTSB
28-00077
06Y10327
PALLET TRUCK

WESLEY INT'L

42-27-60XTSB

28-00078
06Y10328

PALLET TRUCK

WESLEY INT'L
42-27-60XTSB
28-00079
06Y10326
PALLET TRUCK
WESLEY INT'L
42-27-60XTSB
28-00080
06Y10325
PALLET TRUCK
GENIE
Z-45/25J IC

25-00012

Z452511A-40650
BOOM, ARM LIFT
ENTWISTLE
EJ-42338
29-03058
62202-54
10K
ENTWISTLE
EJ-42338
29-03059
62202-55
10K
ENTWISTLE
EJ-42338
29-03060
62202-56
10K
ENTWISTLE
EJ-42338
29-03061
62202-57
10K

USNS WASHINGTON CHAMBERS - TABLE 3

MANUFACTURER
SERIAL NO.
MODEL
NOMINAL OUTPUT CHARACTERISTICS
YUASA-EXIDE
IB59406
SES3C-18-1050BNL20
36V DC 1000 A/HR
YUASA-EXIDE
IB59408
SES3C-18-1050BNL20
36V DC 1000 A/HR
YUASA-EXIDE
IB59400
SES3C-18-1050BNL20
36V DC 1000 A/HR
YUASA-EXIDE
IB59407
SES3C-18-1050BNL20
36V DC 1000 A/HR
YUASA-EXIDE
IB59404
SES3C-18-1050BNL20
36V DC 1000 A/HR
YUASA-EXIDE
IB59403
SES3C-18-1050BNL20
36V DC 1000 A/HR
YUASA-EXIDE
IB59402
SES3C-18-1050BNL20
36V DC 1000 A/HR
YUASA-EXIDE
IB59405
SES3C-18-1050BNL20
36V DC 1000 A/HR
YUASA-EXIDE
IB59390
SES3C-18-1050BNL20
36V DC 1000 A/HR
YUASA-EXIDE
IB59411
SES3C-18-1050BNL20
36V DC 1000 A/HR
YUASA-EXIDE
IB59410
SES3C-18-1050BNL20
36V DC 1000 A/HR
YUASA-EXIDE
IB59401
SES3C-18-1050BNL20
36V DC 1000 A/HR
YUASA-EXIDE
IB59598
SES3C-36-1050BNL20
72 V DC
YUASA-EXIDE
IB59596
SES3C-36-1050BNL20
72 V DC
YUASA-EXIDE
IB59601
SES3C-36-1050BNL20
72 V DC

USS KANAWHA - TABLE 1

MANUFACTURER
MODEL
MSC NUMBER
SERIAL NUMBER
TYPE/SAFETY
HYSTER
E40ZG
2302317
G108N10774F
STD ELEC
HYSTER
E40ZG
2302318
G108N10862F
STD ELEC
HYSTER
E40ZG
2302319
G108N10871F
STD ELEC
HYSTER
SG0FTG
2302136
F187F11814F
STD DIESEL
HYSTER
S60FTG
2302177
F187G12089F
STD DIESEL
HYSTER
S60FTG
2302178
F187G12291F
STD DIESEL

USS KANAWHA - TABLE 3

MANUFACTURER
SERIAL NO.
MODEL
LOCATION
B F Systems Inc
SNA097
8826
42.3 VDC AT 200 AMPS MAX
B F Systems Inc
SNA098
8826
42.3 VDC AT 200 AMPS MAX
B F Systems Inc
SNA099
8826
42.3 VDC AT 200 AMPS MAX
B F Systems Inc
SNA100
8826
42.3 VDC AT 200 AMPS MAX

8. Deliverables:

a. Contractor shall provide a condition report for each unit that identifies the current operational condition of onboard MHE, status of safety devices (e.g. backup-alarms), and all repairs completed. The condition reports shall be provided to the ship’s Chief Engineer and a copy provided to the MHE Program Manager at MSC Norfolk (N48).

b. Contractor shall complete and sign an MHE Safety Certification Form for each forklift listed in Table 1 in accordance with NAVSEA Instruction SW023-AH-WHM-010 [reference (a)]. The crew member performing/assisting in the certification shall also sign each document. Contractor shall provide the original signed forms to the Ships Master or his designated representative, and a copy shall be provided to the MHE Program Management Office at MSC Norfolk (N48).

c. Contractor shall complete and sign a Fork Inspection Form for each unit listed in Table 1 in accordance with NAVSUP P-538. The original signed forms shall be provided to the ship's Master or his designated representative. A copy of the signed forms shall be provided to the MSC Norfolk MHE Program Management office.

d. Contractor shall complete and sign a safety certification form on all Aerial Work Platforms (AWP’s)/Pallet Jack/10K Trailer listed in Table 2 in accordance with the vehicle technical manual and the procedures set forth in NAVSUP P-538.

e. Contractor shall out-brief the ship’s Master and Chief Engineer on the completed project prior to departing the vessel. A written report shall accompany this out-brief. The written report shall be provided to the Ships Master or his designated representative, and a copy shall be provided to the MHE Program Management Office at MSC Norfolk (N48).

9. Qualifications. The selected service provider/contractor must meet the following qualifications:

a. All management and technical personnel performing above listed services must be able to demonstrate, in the form of written documentation, the following experience and skills:

- Three years’ experience performing safety certifications on shipboard-approved electric forklifts, diesel forklifts, and aerial work platforms in accordance with the requirements set forth in the NAVSEA SW023-AH-WHM-010, NAVSUP PUB 538, and equipment technical manuals.

- Experience performing independent services to Shipboard MHE while the equipment is located onboard a vessel. This shall include the maintenance, repair, and safety certification of all MHE onboard multiple vessels configured with electric forklifts, diesel forklifts, manual pallet jacks, Aerial Work Platforms, and 36V battery chargers.

- Independent services shall be defined as performing the service without direct supervision from shipboard personnel. Services performed with the "assistance" of junior personnel, or personnel in training, qualify as independent.

- Three years’ experience interpreting, trouble-shooting, and resetting Hyster MHE on-board dash displays

b. Contractor personnel performing repairs and maintenance onboard MSC vessels shall abide by all DOD, Navy, and MSC security requirements and clearance procedures required to access U.S. Government facilities and MSC vessels.

c. Proof of U.S. citizenship shall be provided in order to enter a U.S. military facility, if requested by the Government. When accessing US Government installation, proposed contractor personnel shall be vetted by the Government through the Government's El Paso Intelligence Center (EPIC) before accessing the Government installation

d. The contractor shall complete a security form for each employee that will be servicing MHE onboard government installations and submit the information (including, but not limited to name, social security number, and birth date) to the MSC/MSC security officer, as requested. The Government will provide approval for personnel to access installations for a pre-determined timeframe (up to one year), as appropriate.

e. The contractor must be able to perform the required services within the period of performance identified in the Statement of Work. If additional work is identified, and approved by the Government, the Contractor must have the ability to ride the vessel underway to complete this additional work.

10. Technical Points of Contact (POCs):

- POC: Tangya Ragin – tangya.ragin.ctr@navy.mil

- Alternate POC: Robert Hall - Robert.m.hall1.ctr@navy.mil

11. Shipboard Points of Contact (POC):

WASHINGTON CHAMBERS Chief Engineer:
Timothy Nesbitt
Email: timothy.nesbitt.civ@ake11.navy.mil (and/or)
cheng@ake11.navy.mill
Ship phone: 619-545-6963 / 619-544-7137
WASHINGTON CHAMBERS Principal Port Engineer:
Ornie McCoy
Email:orni.mccoy@navy.mil
Office:757-443-0881 757-434-2832
WASHINGTON CHAMBERS Supply Officer:
David Aquiningoc
Email: david.aquiningoc.civ@ake11.navy.mil

BAHRAIN Port Engineer:

Scott Finocchiaro
Email: Scott.Finocchiaro@me.navy.mil
Office: 011-973-1785-9491
Mobile: 011-973-3941-8415

KANAWHA Chief Engineer:

Christopher Mudry
Email: christopher.t.mudry.civ@msc.navy.mil (and/or)
cheng.kanawha@msc.navy.mil
Ship phone: 619-544-7171/7170
KANAWHA Supply Officer:
Edward Owens
Email: edward.t.owens.civ@msc.navy.mil, (and/or)
SUPPO.laramie@msc.navy.mil

KANAWHA Principal Port Engineer:

John Mosholder
Email:john.mosholder@ navy.mil
Office:757-443-2288
Cell: 757-373-9897

12. Travel:

a. Access paperwork: Will be provided by the Ship Support Unit (SSU).

b. Travel expenses: Will be in accordance with Department of Defense JOINT TRAVEL REGULATIONS, (JTR) VOL. 2 Change 561 dated 1 JULY 2012.

13. RFQ Submittal: In response to the above information and statement of work or work item, the contractor is afforded the opportunity to submit a quote (consistent with applicable contract rates) and total pricing to provide the aforementioned service(s) or materials.

a. Contractor shall ensure their designated representatives can access the specified Government Activity, Shipyard, and vessel prior to submitting a quotation.

b. Quotes shall be provided on company letterhead and reference the applicable RFQ number (provided above)

c. Quotes shall be provided to the following contracting officer, via email:

Melvin Frazier Military Sealift Command Simplified Acquisition Program Branch, N102 471 "C" Street Bldg. SP-64 Norfolk, VA 23511 Phone: 757.443.5906 Fax: 757.443.5979 E-mail: melvin.frazier@navy.mil

File details come from the government source that posted it. Updated .