N00421-17-Q-0334-0001.docx
DOCX document 42 KB Posted
- Attached to
- Digital Image Correlation Federal contract opportunity
- Solicitation number
- N00421-17-Q-0334
About this file
The purpose of this amendment is to revise solicitation from competitive to sole source with Correlated Solutions, Inc (CSI) for the procurement of VIC-3D Digital Image Correlation System IAW the SOW. This is a 100% brand name mandatory as the data from CSI system can integrate with an identical unit that the Air Force and NASA uses, which makes cross agency integration possible. Due to this mandatory requirement, no other brand will be considered.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N00421-17-Q-0334.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N0042117Q0334
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION A - SOLICITATION/CONTRACT FORM
The required response date/time has changed from 14-Aug-2017 05:00 PM to 06-Sep-2017 05:00 PM.
The following have been modified:
SOLICITATION/CONTRACT FORM
Solicitation N00421-17-Q-0334-0001 is issued as sole source procurement. The Government intends to purchase on a firm fixed-price basis, and to solicit and negotiate the proposed purchase order on a sole source with Correlated Solutions, Incorporated (CSI) for the procurement of Digital Image Correlation (DIC) System in accordance with the Statement of Work, under the authority implemented by Federal Acquisition Regulation (FAR) by FAR Part 12 and 13. This is a 100% brand name mandatory as the data from CSI system can integrate with an identical unit that the Air Force and NASA uses, which makes cross agency integration possible. Due to this mandatory requirement, no other brand will be considered.
This is a total set-aside for small business under the authority of FAR Part 52.219-6.
ONLY New Equipment, NO Remanufactured, and all items must be covered under the manufacturer’s warranty and MUST BE TAA COMPLIANT.
Interested parties must be registered in System for Award Management (SAM) Database prior to submission of an offer to be considered for award of any Department of Defense contract. This can be accomplished electronically at http://www.sam.gov/vendor.cfm. The Government will not pay for any information received
Government Point of Contact:
Bernie Cortez Naval Air Warfare Center AD (PAX)
2.5.1 RAC, 21983 Bundy Road, BLDG 441
Patuxent River, MD 20670-1127 Email: bernie.cortez@navy.mil (preferred method)
SECTION B - SUPPLIES OR SERVICES AND PRICES
CLIN 0001
The CLIN description has changed from Digital Image Correlation to VIC-3D.
The CLIN extended description has changed from:
Digital Image Correlation (DIC) System per SOW.
To:
VIC-3D Digital Image Correlation System-Vic-3D v7.0 Digital Image Correlation Analysis Software-Vic-3D Fulcrum Software Module (for vibration or fatiguesynchronization)-Vic-2D Digital Image Correlation Analysis Software (included atno additional cost)-Vic-Snap FC Image Acquisition Software-One VIC-Snap Remote Control Tablet with case-One CSI Aluminum Cart Workstation with rackmout Quad-corePC, 64GB RAM, Win 10 64 bit, 1TB SSD, 8TB HD, dual 24" LCDmonitors, UPS, rear access panel, and four locking drawers-Two 16 Megapixel ((4864x3232 @ 5fps) Class 1 Sensor DigitalCameras-Two Nikon 50mm Lenses-Two Nikon Nikkor 85mm Telephoto Lenses-Two Tokina 100mm 1:1 Macro Lenses-One 8-Channel USB analog data acquisition system for Fulcrum(8-channel @ 1.25 MS/s)-One 6000 Lumen High-Speed LED lighting System with Flood &Strobe Controller-Two CSI LED Lighting Systems with Positioning Arms-One Aluminum Channel Stereo Mounting System-One Carbon Fiber Tripod-One Super Pro Tripod Head-One Professional Tripod Bag-Two-piece Glass Grid set with positioning arm (FOV < 1")-Six-piece coded aluminum composite calibration grid set (FOV 1''to 8'') with case-One hard-sided carrying case for cameras, lenses, and accessories-VIC Speckle Pattern Application Kit (Includes Four stamp rollers.with self-inking inserts, four interchangeable stamps with oneacrylic rocker, three perforated stencils with one stencil frame, oneink pad with an extra bottle of ink, and a carrying case)-Includes one post-processing license on USB dongle-Includes technical support and software upgrades for 1 yr.-Two year warranty on all non-consumables.
CLIN 0002
This CLIN has been renumbered to CLIN 0003.
CLIN 0003
This CLIN has been renumbered to CLIN 0002.
The CLIN description has changed from Training to 3D Install.
The CLIN extended description has changed from:
Two-day Training Seminar and install (Patuxent River, MD. 20670).
VIC-3D delivery and two-day training seminar.
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been modified:
STATEMENT OF WORK
Background:
Strain in components is typically measured using strain gages. Unfortunately, application of strain gages is expensive, can cause damage to the aircraft component, and only results in a single point measurement. Further strain gauges cannot measure steep strain/stress gradients in highly stresses components. To adequately validate finite element models (FEM) a full field non-contacting strain measurement system is required. A Digital Image Correlation (DIC) System will provide full-field, 3-Dimensional measurements of shape, displacement and strain, based on the principle of Digital Image Correlation. Using this method, actual object movement is measured and the Lagrangian strain tensor is computed at every point on the specimen’s surface. In order to make the system useable in a laboratory environment to support fielded hardware issues, a turn-key system for measuring the shape, displacement and strain of surfaces in three dimensions is needed. USN needs an all-in-one system that includes all necessary hardware and software to handle the current needs.
The required system needs to comply with the following minimum general requirements:
- Measure arbitrary displacements and strains from 50 micro-strain to 2,000% strain and above.
- Measurements should be possible on component surfaces ranging from <0.5mm^2 to >10m^2.
- Setup should be simple, requiring only a quick, flexible calibration procedure, using an applied random speckle pattern.
- Must not require any special illumination from lasers or specimen contact during testing.
- Camera Resolution of 11 MP, at 5 fps
- Minimum Strain measurement range from 0.005% to >2,000%
- System must be able to provide full field measurements of a part vibrating at up to 3000 Hz with resolution down to 50 micro-strain at 0.5mm X 0.5mm.
- Must be able to acquire full resolution data at component surfaces up to 45° from normal to the camera.
- Portability and Convenience: The system should be extremely portable and data can be collected in a wide range of settings with ease. Results can be processed on-the-spot, or data can be exported for off-line processing. Processing can be done on any Windows PC with flexible floating licenses. Data files should be compatible with CSI DIC systems currently in use at the AFRL TEFF (Turbine Engine Fatigue Facility) and NASA. This necessity is due to tests that will be executed at different Govt. agencies and the data merged to generate the system level results.
- Performance and Accuracy: The system and the correlation algorithms must be able to execute real-time processing and can be achieve it without a need for super computers or processing hardware, while ensuring fast and reliable results. Accuracy should be +/- 1% on a smooth metal surface.
The desired DIC equipment features, should meet the following Requirements:
A full-field real-time module, that would allow 3D test data to be displayed from streaming images while running the test. Live data must be displayable in any number of desired “user-defined” 3D plots, 2D contour image overlays.
Unlimited technical support access (via phone or email) based in the Continental U.S.A.
The system should come with permanent licenses for both the acquisition and the analysis software packages. System should have a flexible/portable post-processing license, which would allow data analysis and report preparation on any other authorized PC.
Operating system compatibility: the system should smoothly interface with common word processing, presentation, and spreadsheet software packages. Complete image acquisition and analysis should be compatible with Windows 7 & up. The system must directly interface with all office suite products. Data exporting tools should allow users to generate reports with common programs such as MS Office and OpenOffice. Data plots, full-field displays, and video animations must be exportable into a number of standard formats to create quick custom reports and presentations.
The DIC system must be able to conduct High-speed Vibration measurements. The system should allow full-field 3D viewing, measurement, and analysis of full-field operational deflection shapes that would occur from Steady State, and/or Transient vibration events.
The Image acquisition Software features, should meet the following minimum requirements:
Real-Time Calibration: The system must allow that calibration images are immediately analyzed and the overall calibration score shown in real-time. This would greatly increase the speed and efficiency of the calibration procedure. The user must receive real-time feedback of calibration target marker extractions and the final calibration score.
Image Saturation Feedback: The system must be able to detect if/when the speckle pattern becomes overexposed due to a reflective surface, a change in lighting conditions, or deformations of the sample. The system’s software must alert the user that light saturation is occurring on the image, so that necessary adjustments can be made accordingly.
Adjustable Image Capture Rate: The DIC data acquisition software must allow the user to define and/or pre-program the number of images taken at pre-defined periods of the test. This required feature, would allow fine-tuning (increasing/decreasing) the image capture rate at critical times during a test (e.g. crack initiation & propagation period).
User-defined Software and Hardware Trigger Options: The system should provide the option for the user to define image acquisition rate and start-time via several types of trigger modes, such as:
o User should be able to pre-define image acquisition rate and start-time intervals for a set duration of time.
o Alternately, a hardware signal (e.g., a TTL signal 0 - 5V pulse) can be used to trigger cameras at regular intervals, or initiate the acquisition at a predefined rate
SECTION F - DELIVERIES OR PERFORMANCE
The following Delivery Schedule item for CLIN 0001 has been changed from:
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| DODAAC / CAGE |
| 30-SEP-2017 |
| 1 |
| N/A |
FOB: Origin (Shipping Point)
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| DODAAC / CAGE |
| 31-OCT-2017 |
| 1 |
| N/A |
The following Delivery Schedule Item has been deleted from CLIN 0002:
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| DODAAC / CAGE |
| 30-SEP-2017 |
| 1 |
| N/A |
The following Delivery Schedule Item has been deleted from CLIN 0003:
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| DODAAC / CAGE |
| 30-SEP-2017 |
| 1 |
| N/A |
The following Delivery Schedule item for CLIN 0004 has been changed from:
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| DODAAC / CAGE |
| 30-SEP-2017 |
| 1 |
| N/A |
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| DODAAC / CAGE |
| 31-OCT-2017 |
| 1 |
| N/A |
(End of Summary of Changes) image1.wmf