2.1.1 22R0026 Amend 0001.pdf

PDF 369 KB Posted

Attached to
SCBA Trailers Federal contract opportunity
Solicitation number
N0040622R0026
Issued by
Department of the Navy Naval Supply Systems Command

About this file

This solicitation seeks three self-contained breathing apparatus (SCBA) trailers. Interested parties may submit proposals prior to the offer due date of May 5, 2022. The Navy intends to award a firm-fixed price contract utilizing FAR Part 12 and Subpart 13.5 procedures. This acquisition has been set aside for small businesses. The SCBA trailers must meet specifications in the solicitation and be delivered to Navy Region Northwest in Keyport, Washington. Offerors are responsible for downloading the solicitation from SAM.gov and monitoring the site for amendments. Questions should be directed to the point of contact via email.

View the file

Other files for this federal contract opportunity

Other files attached to SCBA Trailers, newest first.
File Type Posted
2.1.1 22R0026 Amend 0003.pdf PDF
2.1.1 22R0026 Amend 0002.pdf PDF
2.1.2 22R0026 Solicitation.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N6874222RC00J2C

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

This amendment is issued to provide Questions and Answ ers.

Admin POC: Melanie Johnson melanie.r.johnson16.civ@us.navy.mil

1. CONTRACT ID CODE PAGE OF PAGES

J 1 3

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 11-May-2022

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X N0040622R0026

X 9B. DATED (SEE ITEM 11)

05-May-2022

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

11-May-2022

CODE

NAVSUP FLC PUGET SOUND

467 W STREET, 2ND FLOOR

ATTN: M.JOHNSON

BREMERTON WA 98314

N00406 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

N0040622R0026

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SECTION SF30 - CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION A - SOLICITATION/CONTRACT FORM

The following have been added by full text:

QUESTIONS AND ANSWERS

1. QUESTION: Trailer enclosed or open?

ANSWER: Enclosed

2. QUESTION: if enclosed, what color?

ANSWER: Red

3. QUESTION: 15-HP 3-phase electric motor, what voltage 208/230/460?

ANSWER: 208/230 volt

4. QUESTION: 19-KW genset direct drive, gas or diesel?

ANSWER: Diesel

5. QUESTION: 4.5 auto storage refill circuit more details are required.

ANSWER: A cascade control system shall be included for the number of banks specified to permit drawing down each air storage cylinder independently of each other for while filling SCBA cylinders. The system shall include an automatic refill system designed to feed air from the breathing air compressor and air storage system to the SCBA fill station. When SCBA fill operation ceases, air from the compressor will be diverted to top-off the air storage system before shutting off. Anytime that the operator resumes the SCBA fill process, the compressor will flow to the fill station as the priority. This automatic refill system requires no operator action to perform these functions.

6. QUESTION: Auxiliary electrical outlets, how many?

ANSWER: The unit shall include an auxiliary electric outlet box located within the enclosure that shall include four, 15-amp outlets with two for 110V and two for 220V source.

7. QUESTION: Elevated scene lighting need details/ what do you require?

ANSWER: This is a non-rotating light tower that shall be capable of rising from 0 to 120 degrees and includes a 4x500 watt light bank. Actuation of the light tower shall be accomplished electrically, via a 12vdc motor, and not require system air or hydraulic power for operation to eliminate leaks. The actuation of the light shall be through a hand-held remote-control unit, including a 6' cable, mounted on the operating and air control operations center located at the rear of the breathing air trailer. The approximate extended height of the light tower is 10-ft. from ground level.

8. QUESTION: Max weight 6,400 lbs this is borderline too much for a single axle trailer. Is this limit a hard limit or a target?

ANSWER: Weight should be less than 6,400 lbs so it’s a hard limit.

N0040622R0026

9. QUESTION: Bolt-on hitch for either electric or surge brakes will need to know surge or electric?

ANSWER: Electric

(End of Summary of Changes)