N00253-15-T-0463.pdf
PDF 243 KB Posted
- Attached to
- ISO CONTAINER Federal contract opportunity
- Solicitation number
- N00253-15-T-0463
About this file
N00253-15-T-0463 ISO CONTAINER
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NAVAL UNDERSEA WARFARE CENTER
ATTN: LINDY CARLSON
MELINDA.CARLSON@NAVY.MIL
610 DOWELL ST
KEYPORT WA
360-315-5851
UNDER DPAS (15 CFR 700)
11. DELIVERY FOR FOB
RFQ
SEE SCHEDULE
X
DO-C9
14. METHOD OF SOLICITATION
IFB RFP
CODE
SEE ADDENDUM
BLOCK IS MARKED
DESTINATION UNLESS
12. DISCOUNT TERMS
(No Collect Calls)
13b. RATING
13a. THIS CONTRACT IS A RATED ORDER
X
CODE
N00253-15-T-0463 27-Jul-2015
b. TELEPHONE NUMBER
360-315-5851
8. OFFER DUE DATE/LOCAL TIME
10:00 AM 06 Aug 2015
5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
STANDARD FORM 1449 (REV 3/2005)
Prescribed by GSA
FAR (48 CFR) 53.212
(TYPE OR PRINT)
(SIGNATURE OF CONTRACTING OFFICER) 31c. DATE SIGNED
ADDENDA ARE
26. TOTAL AWARD AMOUNT (For Gov t. Use Only )
22. UNIT 23. UNIT PRICE 24. AMOUNT21. QUANTITY
CODE 10. THIS ACQUISITION IS
UNRESTRICTED
FAX: NAICS:
TEL:
CODE 18a. PAYMENT WILL BE MADE BYOFFEROR
SUCH ADDRESS IN OFFER
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT
BELOW IS CHECKED
TEL.
N00253
SIZE STD:
9. ISSUED BY
FACILITY
CODE
17a.CONTRACTOR/
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK
15. DELIVER TO CODE N00253 16. ADMINISTERED BY
NAVAL UNDERSEA WARFARE CENTER
RECEIVING OFFICER
ATTN: DIVISION KEYPORT SUPPLY OFFICER
BLDG 893
610 DOWELL STREET
KEYPORT WA 98345-7610
TEL: 360 396-2760 FAX:
7. FOR SOLICITATION
INFORMATION CALL:
a. NAME
MELINDA S CARLSON
2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER
(TYPE OR PRINT)
30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER
30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA
0 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.
25. ACCOUNTING AND APPROPRIATION DATA
1. REQUISITION NUMBER
19. ITEM NO. 20. SCHEDULE OF SUPPLIES/ SERVICES
SEE SCHEDULE
332311
TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND DELIVER ALL ITEMS
SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY ADDITIONAL SHEETS
SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED HEREIN.
SB
HUBZONE SB
SET ASIDE: 100 % FOR
OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
ARE NOT ATTACHED
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED
TEL: EMAIL:
1 COPIES
(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE
SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:
.OFFER DATED YOUR OFFER ON SOLICITATION
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN 29. AWARD OF CONTRACT: REFERENCE
X
8(A)
SVC-DISABLED VET-OWNED SB
EMERGING SB
X
X
32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
(CONTINUED)
SEE SCHEDULE
19. ITEM NO. 20. SCHEDULE OF SUPPLIES/ SERVICES 21. QUANTITY 22. UNIT 24. AMOUNT
PAGE 2 OF
23. UNIT PRICE
ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________
32a. QUANTITY IN COLUMN 21 HAS BEEN
RECEIVED INSPECTED
32b. SIGNATURE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE
37. CHECK NUMBER
FINALPARTIALCOMPLETE
36. PAYMENT35. AMOUNT VERIFIED
CORRECT FOR
34. VOUCHER NUMBER
FINAL
33. SHIP NUMBER
PARTIAL
38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY
41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT
41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE
42a. RECEIVED BY (Print)
42b. RECEIVED AT (Location)
42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS
STANDARD FORM 1449 (REV 3/2005) BACK
Prescribed by GSA
FAR (48 CFR) 53.212
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
N00253-15-T-0463
Section SF 30 - BLOCK 14 CONTINUATION PAGE
SOLICITATION INFORMATION
NOTE 1: Government Point of Contact for this Solicitation/Request for Quote (RFQ) is: Melinda Carlson Purchasing Agent, Phone: 360-315-5851, Fax: 360-396-7036 Email: melinda.carlson@navy.mil
NOTE 2: All questions regarding this solicitation should be submitted in writing as soon as practicable after receipt of solicitation. Email questions to Melinda Carlson. Questions received after a reasonable time may not be entertained.
NOTE 3: Utilize the pages in this solicitation to list all unit prices, extended prices, manufacturers and their part numbers, along with description changes (if any). Each Item No. or “CLIN” must be filled out.
Company quote forms may be used, but not substituted for a completed solicitation/amendment pages.
NOTE 4: If you cannot meet the requested delivery date/Period of Performance (POP), line through and replace with your availability. Offers shall be FOB Destination in accordance with FAR Clause 52.247-34
NOTE 5: Constructive Acceptance Timeframe is 7 days after receipt of material..
NOTE 6: Offeror shall supply Manufacturer and/or Service Provider’s information as requested in provision C.108. Supply city/state if in the United States and/or the country of origin if outside the United States.
NOTE 7: The government prefers submission of this RFQ by email or fax.
NOTE 8: Performance under this contract requires the contractor to adhere to Operations Security (OPSEC) requirements. Explanation of these requirements is detailed in Section I of the Operations Security Guide for Defense Contractors available online at:
http://www.navsea.navy.mil/Home/WarfareCenters/NUWCKeyport/Resources.aspx Click on OPSEC Guide For Defense Contractors on the right-hand side.
NOTE 9: COMPLIANCE WITH SPECIFICATIONS
In order to ensure compliance with all the specification requirements, the contractor shall indicate in its offer and notify the Government in a cover letter, what specifications, if any; the offeror does not intend to meet. The offeror shall explain, in detail, how any proposed deviation/exception will nonetheless meet the Government's functional requirements. Should descriptive literature be supplied by the offeror, it will be presumed that the offeror intends to meet all of the specifications, regardless of the descriptive literature, unless the offeror specifically notes its exceptions.
It shall be the obligation of the contractor to exercise due diligence to discover and to bring to the attention of the contracting officer at the earliest possible time, in writing, any ambiguities, discrepancies, inconsistencies, or conflicts in or between the specifications and the applicable drawings or other documents incorporated by reference herein. Failure to comply with such obligation shall be deemed a waiver and release of any and all claims for extra costs or delays arising out of such ambiguities, discrepancies, inconsistencies, and conflicts.
STATEMENT OF WORK
1.1 SIZE/WEIGHT/CAPACITY
1.1.1 20’Lx8’Wx8’6”H Steel Dry Freight International Standards Organization (ISO) container with eight (8) standard ISO corner fittings.
1.1.2 The container shall have ISO standard fork pockets for moving the unloaded container.
1.1.3 The container shall be of new construction
1.1.4 The container shall have corrugated steel sides and roof.
1.1.5 The container shall have insulated cargo doors and man door.
1.1.6 The container shall have a recessed HVAC unit (minimum of 2 ton capacity).
1.1.7 All additional equipment, connectors, handles, and tie downs external to the walls of the structure shall fit within the dimensions listed in section 1.1.1.
1.1.8 The total weight of the container at the completion of the fabrication and modification process shall not exceed 12,000 lbs.
1.1.9 The gross rated weight of each container shall be a minimum of 20,000 lbs.
1.2 MATERIALS/CONSTRUCTION –
1.2.1 All materials shall be inherently resistant to marine corrosion (i.e. fiberglass, stainless steel, marine grade aluminum, marine grade wood, painted steel).
1.2.2 All floors, walls and ceilings shall be sealed to prohibit the intrusion of water into the structure. Construction shall be done in such a way that water will not penetrate into the walls, ceiling, or floor from either the outside or the inside.
1.2.3 The interior floor covering shall be marine grade linoleum tile or comparable material.
1.2.4 One end of the container shall have double doors that are insulated and unobstructed when opened in order to move equipment racks into and out of the container.
1.2.5 The only penetrations permitted in the container are for;
1.2.5.1 The Heating Ventilation and Air Condition (HVAC) unit.
1.2.5.2 Power entry panels.
1.2.5.3 Cable penetrations.
1.2.5.4 Windows.
1.2.5.5 Personnel door.
1.2.6 PAINT:
1.2.6.1 Painting shall be completed only after all hot work fabrication has been completed.
1.2.6.2 All carbon steel surfaces shall be primed and painted.
1.2.6.2.1 This requirement is a corrosion control measure and applies to surfaces even if the surface is not visible upon fabrication completion.
1.2.6.3 Stainless steel pieces shall not be painted.
1.2.6.4 The selected paint manufacturer guidelines for surface preparation, application and curing of paints and primers shall be followed unless a more stringent requirement is stated in this document.
1.2.6.5 The exterior is all surfaces on the outside of the container.
1.2.6.5.1 For painting purposes this is to include the roof, all four walls/sides, understructure, cable penetrations, and personnel door.
1.2.6.6 The exterior shall have a minimum surface preparation standard of Society for Protective Coatings (SSPC)-SP 7 / National Association of Corrosion Engineers International (NACE) No. 4.
1.2.6.6.1 If the paint manufacturer specifies a more stringent value than SSPC-SP7 their specified surface preparation shall be followed.
1.2.6.7 The exterior color shall be Haze Gray.
1.2.6.7.1 The exterior roof top coat shall be a non-skid type top coating that satisfies MIL-PRF-24667C (C or newer).
1.2.6.7.2 The exterior walls/sides and understructure top coat shall satisfy MIL- PRF-24635C (C or newer)
1.2.6.8 The interior is all surfaces on the inside of the container.
1.2.6.9 The interior floor covering (section 1.2.3) shall not be painted.
1.2.6.10 The interior shall be painted
1.2.6.11 The interior paint top coat shall be marine grade semi-gloss polyurethane that is the color white.
1.2.6.12 The insulation covering shall be primed and painted unless section 1.2.7.4 applies.
1.2.6.13 The top coat of paint for the insulation covering shall be the same as in section 1.2.6.11
1.2.7 INSULATION (INTERIOR WALLS AND CEILING):
1.2.7.1 The walls (Right, Left, Front, Rear) and ceiling shall be covered with 1-1/2” extruded closed cell foam insulation laminated to 3/8” plywood.
1.2.7.2 The closed cell foam shall have a minimum R-value of 5. R-value is expressed in ft2• h•°F/Btu and determined by ASTM C518.
1.2.7.3 The plywood covering shall be fire-treated.
1.2.7.4 It is acceptable for the plywood covering to have a finish of white high density polyethylene (HDPE) as an alternative to painting the plywood.
1.2.7.5 Installation of the plywood covering with or without an HDPE finish shall be uniform throughout the container.
1.2.7.6 The insulation shall not cover the windows, the personnel door or the cable penetrations.
1.2.7.7 All insulation and coverings shall be secured into place by the appropriate industry standard method.
1.2.8 WINDOWS:
1.2.8.1 The two windows shall be installed on each side near the center of the container.
1.2.8.2 The window frame shall be welded to the container.
1.2.8.3 The windows shall not be able to be opened.
1.2.8.4 The window size shall have an opening of 24” wide by 24”.
1.2.8.5 The top of the window shall be less than 12 inches from the ceiling.
1.2.8.6 The windows shall be covered on the outside with steel bars to protect the glass.
1.2.8.6.1 The window glass shall be fire and impact safety rated.
1.2.8.6.2 The window glass shall not be wired glass.
1.2.9 PERSONNEL DOOR:
1.2.9.1 The personnel door shall be installed on the right side.
1.2.9.2 The personnel door frame shall be welded to the container.
1.2.9.3 The personnel door shall open/swing out.
1.2.9.4 The personnel door shall be right hand (RH) swing.
1.2.9.5 The personnel door shall have an opening of 36” wide by 80” to 84” high.
1.2.9.6 The personnel door shall have a window in the upper half of the door with steel bars to protect the glass.
1.2.9.6.1 The minimum window dimensions shall be 23”wide by 29” high.
1.2.9.6.2 The window glass shall be fire and impact safety rated.
1.2.9.6.3 The window glass shall not be wired glass.
1.2.9.7 The personnel door shall have a stainless steel lever type handle that is rated for use outside in a marine environment.
1.2.9.8 The personnel door shall be fitted with stainless steel hasp for a padlock.
1.2.9.9 The hasp shall be able to receive a padlock equivalent in size and shape to “Sargent & Greenleaf Padlock Model #8077AD.”
1.2.9.10 The personnel door shall be marine grade metal and have type 316L stainless steel or equivalent hinges.
1.2.9.11 The personnel door shall be able to swing open a minimum of 150 degrees.
1.2.9.12 A means to latch the personnel door, when it is in the fully open position, shall be installed on the outside of the container.
1.2.9.13 The personnel door shall have a rain-tight seal.
1.2.10 METAL ANCHOR CHANNEL
1.2.10.1 1-5/8” by 1-5/8” industry standard single channel anchor strut shall be used on the interior container walls and ceiling.
1.2.10.2 The single channel strut shall be made of 12 gauge steel.
1.2.10.3 The single channel strut shall be zinc coated with a minimum coating thickness of
0.5 MIL (MIL = 10-3 inch).
1.2.10.4 The single channel strut shall have a coating which satisfies ASTM B633, Type II
SC3.
1.2.10.5 The single channel strut shall be gold in color.
1.2.10.6 The single channel strut shall not be pierced or slotted. It shall have a solid back.
1.2.10.7 An example of satisfactory single channel strut is Unistrut® part # P1000.
1.2.10.8 Required Load Capacity of All Installed Metal Anchor Channel
1.2.10.8.1 All metal channels shall be secured such that a point load of 400 lbs., applied perpendicular to the longitudinal axis, acting at any location along its length satisfies the manufacturer’s requirements for the load demand.
1.2.10.8.2 The maximum allowable deflection for the 400 lb. point load, listed in section 1.2.10.8.1, shall be less than or equal to span/180.
1.2.10.9 The single channel strut shall be installed flush with the wall covering.
1.2.10.10 White caulking shall be applied, on the interior wall surface, where the single channel strut and insulation wall covering meet.
1.2.10.11 The first placement of single channel strut, for both walls and the roof, shall start 15” to 24” from the rear of the container. The intent of this distance range is to account for the corrugated steel of the walls and roof.
1.2.10.12 The single channel strut shall not be installed over any cutouts.
1.2.10.13 RIGHT & LEFT WALL INTERIOR:
1.2.10.13.1 Install the single channel strut vertically from floor to ceiling.
1.2.10.13.2 Space the single channel strut uniformly on 18” to 24” centers. The intent for this spacing range is to accommodate for the wall corrugation pattern.
1.2.10.13.3 First placement shall be as in section 1.2.10.11.
1.2.10.14 ROOF INTERIOR
1.2.10.14.1 Install the single channel strut on the interior of the roof perpendicular to the side walls.
1.2.10.14.2 The single channel strut shall span from the left wall to the right wall.
1.2.10.14.3 Space the single channel strut uniformly on 36” to 48” centers. The intent for this spacing range is to accommodate for the ceiling corrugation pattern.
1.2.10.14.4 First placement shall be as in section 1.2.10.11.
1.2.11 CABLE PENETRATIONS (Quantity 6 Threaded Pipe Couplers)
1.2.11.1 Quantity six (6) threaded pipe couplers shall be installed through the container walls at separate locations.
1.2.11.2 Pipe couplers shall be steel
1.2.11.3 Pipe couplers shall be welded, all around, to the walls of the container to form a water tight seal.
1.2.11.4 Pipe coupler threads shall satisfy ANSI/ASME B1.20.1 NPT.
1.2.11.5 Plugs shall be supplied for both ends of each threaded coupler.
1.2.11.6 Plugs shall be threaded Polyvinyl Chloride (PVC)
1.2.11.7 Quantity two threaded pipe coupler shall be 4” nominal pipe size.
1.2.11.8 Quantity four threaded pipe couplers shall be 2” nominal pipe size.
1.2.11.9 The threaded pipe couplers shall not extend beyond the following:
1.2.11.9.1 On the Exterior: Flush with the outermost part of the wall it is mounted in.
1.2.11.9.2 On the interior: 2” from the face of the insulation covering toward the interior.
1.2.11.10 LOCATION ON LEFT WALL: (Quantity 6 pipe couplers)
1.2.11.10.1 The two each 4” pipe couplers shall be installed near the top of the container. They shall be within 12” vertically of the top/roof of the container and within 3’ horizontally of the rear door.
1.2.11.10.2 The four each 2” pipe couplers shall be installed directly underneath the 4” couplers. They shall be within 12” vertically of the floor of the container and within 3’ horizontally of the rear door.
1.2.12 POWER PENETRATIONS
1.2.12.1 The power penetrations shall be welded into the right wall of the container forming a watertight seal with the wall.
1.2.12.2 The enclosures shall be an off-the-shelf wall-mount enclosure.
1.2.12.3 The enclosures shall be a National Electrical Manufacturers Association (NEMA) Type 4.
1.2.12.4 The enclosures shall have a height of 12” +/- 1”
1.2.12.5 The enclosures shall have a width of 9” +/- 1”
1.2.12.6 The enclosures shall have a depth of 6” +/- 1/2"
1.2.12.7 The waterproof door of the enclosure shall be secured/sealed by hand without the use of tools.
1.2.12.8 The upper enclosure top shall be 65” above the interior floor.
1.2.12.9 The lower enclosure top shall be 6” below the upper enclosure.
1.2.12.10 The enclosure forward edge shall be 6” to 9” away (moving towards the container rear end) horizontally from the HVAC unit when measured from the interior.
1.2.12.11 The enclosure exterior face (including the enclosure door) shall not extend beyond the container dimensions stated in section 1.1.1.
1.3 HEATING VENTILATIONS AND AIR CONDITIONING (HVAC)
1.3.1 The HVAC unit shall be located on the front wall of the container along its right side.
1.3.1.1 One edge of the HVAC unit shall be within 8” of the right edge of the container.
1.3.1.2 The top of the HVAC unit shall within 8” of the roof of the container.
1.3.2 The HVAC unit shall be recessed on the exterior of the container.
1.3.2.1 The HVAC it shall not increase the overall size of the container as specified in section 1.1.
1.3.3 An example, for placement of the recessed HVAC unit, is SEA BOX, Inc. model
# SB6408
1.3.4 All HVAC equipment shall be rated to operate in a marine environment.
1.3.5 The HVAC supply and return air openings shall be ducted to the inside of the front wall of the container.
1.3.5.1 Grilles shall be installed over the supply air and return air ducts.
1.3.6 The HVAC shall have a fresh air damper that is easily adjustable to allow different amounts of outside air to be introduced.
1.3.6.1 The air damper must have the function to be locked closed
1.3.6.2 The air damper must have a function to allow outside air ventilation up to 20% of the total airflow rating of the HVAC unit.
1.3.7 The HVAC access panels shall be located and accessible on the right side of the container.
1.3.8 The HVAC shall have a digital programmable thermostat.
1.3.9 The HVAC shall be powered by single phase 208/220/240 VAC.
1.3.10 The HVAC shall have a minimum operating airflow of 900 cubic feet per minute (CFM).
1.3.11 The HVAC shall have a minimum nominal cooling capacity of 24,000 British Thermal Units per Hour (BTUH).
1.3.12 The HVAC shall have a distribution duct along the upper right wall of the unit.
1.3.13 The distribution duct shall have 9 shuttered diffusers at equal intervals to allow the user to adjust the airflow to meet the varying needs of the installed equipment.
1.3.14 The duct size and diffusers shall be large enough to flow the required volume of air with half of the duct shutters close.
1.3.15 The HVAC shall have a minimum heating capacity of 8 Kilowatts (KW).
1.3.16 An example of a HVAC unit that satisfies the HVAC heating and cooling requirements is the Bard Wall Mounted Air Conditioner with heater element model
# W24L2-A08XX4XXE.
1.3.17 The HVAC shall be Energy Star® qualified.
1.3.17.1 The system shall have a Seasonal Energy Efficiency Rating (SEER) of 14 or greater, and an
1.3.17.2 Energy Efficiency Ratio (EER) of 11 or greater.
1.3.17.3 The EER is the British Thermal Unit (BTU) rating divided by the wattage consumed.
1.3.18 If multiple HVAC units are used; they shall be sequenced so the no two HVAC units come on at the same time.
1.3.18.1 There shall be a minimum 4 second delay between HVAC units coming on to control power load transients.
1.3.19 HVAC system shall be capable of cooling the interior of the container to 70° F in the Puget Sound area.
1.3.20 The calculated heat radiated inside the container from equipment, people, and solar radiation is 30,000 British Thermal Units (BTU).
1.3.21 The heating function of the HVAC unit shall be sufficient to keep the interior of the container at 70° F with no internal heat load and with an external temperature of 20° F.
1.3.22 Air exchange rates and heat recovery ventilation shall be in accordance with ASHRAE standard 62-99.
1.3.23 Occupancy of six people may be assumed.
1.3.24 Ducting must be at least 78 inches from the floor.
1.4 ELECTRICAL
1.4.1 All wiring internal to the container shall be enclosed in rigid metal electrical conduit.
1.4.2 All electrical components installed shall be Underwriters Laboratories Inc. (UL) Listed to USA safety standards.
1.4.3 The container shall have a 440/480 VAC power inlet and a 120/208 VAC power inlet.
1.4.4 A transformer shall be installed to transform the 440/480 power to 120/208 power.
1.4.5 Transformer shall be located along the front wall below the power distribution panel.
1.4.6 The container shall be supplied with an electrical transfer switch to switch between the 440/480 or 120/208 power inlet.
1.4.7 POWER DISTRIBUTION PANEL
1.4.7.1 One 100 amp 120/208 VAC power distribution panel shall be installed
1.4.7.2 The power distribution panel shall be secured on the front wall
1.4.7.3 No circuit breaker shall be a Ground Fault Circuit Interrupter (GFCI) type.
1.4.7.4 The power distribution panel shall be 100-ampere main breaker load center, 24-space 24-circuit with cover and ground bar.
1.4.7.5 The power distribution panel neutrals and grounds shall be connected to different buses.
1.4.7.6 The power distribution panel neutral bus shall be isolated from the panel.
1.4.7.7 The power distribution panel shall have a ground bar kit installed that is, at a minimum, a 24 position/terminal.
1.4.7.8 Maximum power distribution panel dimensions are;
1.4.7.8.1 Width (Left to Right) maximum is 14.5”
1.4.7.8.2 Height (Up and Down) maximum is 27”
1.4.7.8.3 Depth (In & Out)maximum is 6”
1.4.7.9 The power distribution panel shall be placed so the top is 70” to 73” above the interior floor.
1.4.7.10 The power distribution panel shall satisfy, or exceed, the requirements for NEMA type 2 enclosures.
1.4.7.11 The power distribution panel shall be supplied with power, entering at the base.
1.4.7.12 The base of power distribution panel must be clear so that the bottom may receive conduit for power
1.4.7.13 Panel shall not be grounded to the container.
1.4.7.14 Panel shall be supplied with the following circuit breakers;
1.4.7.14.1 Quantity one (1) 100 ampere main circuit breaker.
1.4.7.14.2 Quantity Four (4) three-pole 50 ampere
1.4.7.14.3 Quantity Ten (10) one-pole 20 ampere
1.4.7.14.4 Required quantity and rating for the HVAC unit
1.4.7.14.5 Required quantity and rating for the two lighting circuits
1.4.8 Lighting
1.4.8.1 Light switches shall be located on the interior wall within 1’ horizontally of the personnel door and 46” to 56” above the floor.
1.4.8.2 Light switches and switch housing shall be marine grade and there shall be two switches housed in a one outlet box.
1.4.8.3 Lighting shall be dual density: 20 lumens per square foot (ft.2) and 40 lumens per ft.2, measured at a height of 30 inches above the floor.
1.4.8.4 Lighting density shall be switch selectable.
1.4.8.4.1 One light circuit closed shall satisfy the lower lumen requirement
1.4.8.4.2 Both light circuits closed shall satisfy the larger lumen requirement.
1.4.8.5 Light fixtures shall be fluorescent light tube, enclosed and gasketed for use in a wet environment.
1.4.8.6 Light fixture lens shall be impact resistant.
1.4.8.7 Light fixture shall be UL Listed to US and Canadian Safety Standards.
1.4.8.8 Light fixture shall be powered by electrical power distribution Panel.
1.4.8.9 No light fixture shall be electrically grounded to the container.
1.4.8.10 No light fixture shall be in physical contact with the single channel strut.
1.4.9 Power outlets
1.4.9.1 Quad outlet boxes need to be installed 48 inches from the floor (within 6 inches of) 2, 6, 10, 14 and 18 feet from the double doors inside on both sides of the container.
1.4.9.2 Single 50 amp 208/240 outlet boxes need to be installed 48 inches from the floor (within 6 inches of) 4 and 12 feet from the double doors inside on both sides of the container.
1.4.10 Each outlet box shall have a separate breaker in the power distribution panel.
1.5 Delivery
The bid for this contract shall include all freight charges for delivery to;
NUWC Keyport 610 Dowell Street Attn: C/1021 Keyport, WA 98345-7610
1.6 A sketch detailing the location of the openings and equipment shall be submitted for government approval 5 days prior to fabrication or modification of the container.
Section SF 1449 - CONTINUATION SHEET
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
0001 1 Each
ISO CONTAINER
FFP
New Portable Communications Shelter, to be manufactured in accordance with the statement of work.
20'X8'X8.5" To include:
Personnel Door Windows Electrical Modifications and HVAC FOB: Destination
NET AMT
INSPECTION AND ACCEPTANCE TERMS
Supplies/services will be inspected/accepted at:
CLIN INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY
0001 Destination Government Destination Government
DELIVERY INFORMATION
CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS UIC
0001 30-SEP-2015 1 NAVAL UNDERSEA WARFARE CENTER
RECEIVING OFFICER
ATTN: DIVISION KEYPORT SUPPLY
OFFICER
BLDG 893
610 DOWELL STREET
KEYPORT WA 98345-7610
360 396-2760 FOB: Destination
N00253
CLAUSES INCORPORATED BY REFERENCE
52.204-2 Security Requirements AUG 1996 52.204-7 System for Award Management JUL 2013 52.204-13 System for Award Management Maintenance JUL 2013 52.204-16 Commercial and Government Entity Code Reporting NOV 2014 52.204-18 Commercial and Government Entity Code Maintenance NOV 2014 52.204-19 Incorporation by Reference of Representations and
Certifications.
DEC 2014
52.209-2 Prohibition on Contracting with Inverted Domestic Corporations--Representation
DEC 2014
52.211-15 Defense Priority And Allocation Requirements APR 2008 52.212-1 Instructions to Offerors--Commercial Items APR 2014 52.212-4 Contract Terms and Conditions--Commercial Items MAY 2015 52.232-39 Unenforceability of Unauthorized Obligations JUN 2013 52.232-40 Providing Accelerated Payments to Small Business
Subcontractors
DEC 2013
52.247-34 F.O.B. Destination NOV 1991 252.203-7000 Requirements Relating to Compensation of Former DoD
Officials
SEP 2011
252.203-7002 Requirement to Inform Employees of Whistleblower Rights SEP 2013 252.203-7005 Representation Relating to Compensation of Former DoD
Officials
NOV 2011
252.204-0001 Line Item Specific: Single Funding SEP 2009 252.204-7003 Control Of Government Personnel Work Product APR 1992 252.204-7004 Alt A System for Award Management Alternate A FEB 2014 252.204-7005 Oral Attestation of Security Responsibilities NOV 2001 252.204-7012 Safeguarding of Unclassified Controlled Technical
Information
NOV 2013
252.204-7015 Disclosure of Information to Litigation Support Contractors FEB 2014 252.211-7003 Item Unique Identification and Valuation DEC 2013 252.225-7000 Buy American--Balance Of Payments Program Certificate--
Basic (Nov 2014)
NOV 2014
252.225-7001 Buy American And Balance Of Payments Program-- Basic (Nov 2014)
NOV 2014
252.225-7048 Export-Controlled Items JUN 2013 252.232-7003 Electronic Submission of Payment Requests and Receiving
Reports
JUN 2012
252.232-7010 Levies on Contract Payments DEC 2006 252.243-7001 Pricing Of Contract Modifications DEC 1991 252.247-7023 Transportation of Supplies by Sea APR 2014
CLAUSES INCORPORATED BY FULL TEXT
52.204-17 OWNERSHIP OF CONTROL OF OFFEROR (NOV 2014)
(a) Definitions. As used in this provision--
Commercial and Government Entity (CAGE) code means—
(1) An identifier assigned to entities located in the United States or its outlying areas by the Defense Logistics Agency (DLA) Contractor and Government Entity (CAGE) Branch to identify a commercial or government entity, or
(2) An identifier assigned by a member of the North Atlantic Treaty Organization (NATO) or by the NATO Support Agency (NSPA) to entities located outside the United States and its outlying areas that the DLA Contractor and Government Entity (CAGE) Branch records and maintains in the CAGE master file. This type of code is known as an NCAGE code.
Highest-level owner means the entity that owns or controls an immediate owner of the offeror, or that owns or controls one or more entities that control an immediate owner of the offeror. No entity owns or exercises control of the highest level owner.
Immediate owner means an entity, other than the offeror, that has direct control of the offeror. Indicators of control include, but are not limited to, one or more of the following: Ownership or interlocking management, identity of interests among family members, shared facilities and equipment, and the common use of employees.
(b) The Offeror represents that it [ ___ ] has or [ ___ ] does not have an immediate owner. If the Offeror has more than one immediate owner (such as a joint venture), then the Offeror shall respond to paragraph (c) and if applicable, paragraph (d) of this provision for each participant in the joint venture.
(c) If the Offeror indicates ``has'' in paragraph (b) of this provision, enter the following information:
Immediate owner CAGE code:
Immediate owner legal name: ___
(Do not use a ``doing business as'' name)
Is the immediate owner owned or controlled by another entity?:
[ ___ ] Yes or [ ___ ] No.
(d) If the Offeror indicates ``yes'' in paragraph (c) of this provision, indicating that the immediate owner is owned or controlled by another entity, then enter the following information:
Highest-level owner CAGE code:
Highest-level owner legal name:
(Do not use a ``doing business as'' name)
(End of provision)
52.211-14 NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PREPAREDNESS, AND ENERGY PROGRAM USE (APR 2008)
Any contract awarded as a result of this solicitation will be DX rated order; XX DO rated order certified for national defense, emergency preparedness, and energy program use under the Defense Priorities and Allocations System (DPAS) (15 CFR 700), and the Contractor will be required to follow all of the requirements of this regulation. [Contracting Officer check appropriate box.]
52.212-3 OFFEROR REPRESENTATIONS AND CERTIFICATIONS--COMMERCIAL ITEMS (MAR 2015)
ALTERNATE I (OCT 2014)
The offeror shall complete only paragraphs (b) of this provision if the Offeror has completed the annual representations and certification electronically via the System for Award Management (SAM) Web site accessed through http://www.acquisition.gov . If the Offeror has not completed the annual representations and certifications electronically, the Offeror shall complete only paragraphs (c) through (p) of this provision.
(a) Definitions. As used in this provision--
“Economically disadvantaged women-owned small business (EDWOSB) concern” means a small business concern that is at least 51 percent directly and unconditionally owned by, and the management and daily business operations of which are controlled by, one or more women who are citizens of the United States and who are economically disadvantaged in accordance with 13 CFR part 127. It automatically qualifies as a women-owned small business eligible under the WOSB Program.
“Forced or indentured child labor” means all work or service—
(1) Exacted from any person under the age of 18 under the menace of any penalty for its nonperformance and for which the worker does not offer himself voluntarily; or
(2) Performed by any person under the age of 18 pursuant to a contract the enforcement of which can be accomplished by process or penalties.
“Highest-level owner” means the entity that owns or controls an immediate owner of the offeror, or that owns or controls one or more entities that control an immediate owner of the offeror. No entity owns or exercises control of the highest level owner.
“Immediate owner” means an entity, other than the offeror, that has direct control of the offeror. Indicators of control include, but are not limited to, one or more of the following: Ownership or interlocking management, identity of interests among family members, shared facilities and equipment, and the common use of employees.
“Inverted domestic corporation,” means a foreign incorporated entity that meets the definition of an inverted domestic corporation under 6 U.S.C. 395(b), applied in accordance with the rules and definitions of 6 U.S.C.
395(c).
“Manufactured end product” means any end product in product and service codes (PSCs) 1000-9999, except—
(1) PSC 5510, Lumber and Related Basic Wood Materials;
(2) Product or Service Group (PSG) 87, Agricultural Supplies;
(3) PSG 88, Live Animals;
(4) PSG 89, Subsistence;
(5) PSC 9410, Crude Grades of Plant Materials;
(6) PSC 9430, Miscellaneous Crude Animal Products, Inedible;
(7) PSC 9440, Miscellaneous Crude Agricultural and Forestry Products;
(8) PSC 9610, Ores;
(9) PSC 9620, Minerals, Natural and Synthetic; and
(10) PSC 9630, Additive Metal Materials.
“Place of manufacture” means the place where an end product is assembled out of components, or otherwise made or processed from raw materials into the finished product that is to be provided to the Government. If a product is disassembled and reassembled, the place of reassembly is not the place of manufacture.
“Restricted business operations” means business operations in Sudan that include power production activities, mineral extraction activities, oil-related activities, or the production of military equipment, as those terms are defined in the Sudan Accountability and Divestment Act of 2007 (Pub. L. 110-174). Restricted business operations do not include business operations that the person (as that term is defined in Section 2 of the Sudan Accountability and Divestment Act of 2007) conducting the business can demonstrate—
(1) Are conducted under contract directly and exclusively with the regional government of southern Sudan;
(2) Are conducted pursuant to specific authorization from the Office of Foreign Assets Control in the Department of the Treasury, or are expressly exempted under Federal law from the requirement to be conducted under such authorization;
(3) Consist of providing goods or services to marginalized populations of Sudan;
(4) Consist of providing goods or services to an internationally recognized peacekeeping force or humanitarian organization;
(5) Consist of providing goods or services that are used only to promote health or education; or
(6) Have been voluntarily suspended.
Sensitive technology—
(1) Means hardware, software, telecommunications equipment, or any other technology that is to be used specifically—
(i) To restrict the free flow of unbiased information in Iran; or
(ii) To disrupt, monitor, or otherwise restrict speech of the people of Iran; and
(2) Does not include information or informational materials the export of which the President does not have the authority to regulate or prohibit pursuant to section 203(b)(3) of the International Emergency Economic Powers Act (50 U.S.C. 1702(b)(3)).
“Service-disabled veteran-owned small business concern”—
(1) Means a small business concern—
(i) Not less than 51 percent of which is owned by one or more service-disabled veterans or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more service-disabled veterans; and
(ii) The management and daily business operations of which are controlled by one or more service-disabled veterans or, in the case of a service-disabled veteran with permanent and severe disability, the spouse or permanent caregiver of such veteran.
(2) Service-disabled veteran means a veteran, as defined in 38 U.S.C. 101(2), with a disability that is service-connected, as defined in 38 U.S.C. 101(16).
“Small business concern” means a concern, including its affiliates, that is independently owned and operated, not dominant in the field of operation in which it is bidding on Government contracts, and qualified as a small business under the criteria in 13 CFR Part 121 and size standards in this solicitation.
“Small disadvantaged business concern, consistent with 13 CFR 124.1002,” means a small business concern under the size standard applicable to the acquisition, that--
(1) Is at least 51 percent unconditionally and directly owned (as defined at 13 CFR 124.105) by--
(i) One or more socially disadvantaged (as defined at 13 CFR 124.103) and economically disadvantaged (as defined at 13 CFR 124.104) individuals who are citizens of the United States; and
(ii) Each individual claiming economic disadvantage has a net worth not exceeding $750,000 after taking into account the applicable exclusions set forth at 13 CFR 124.104(c)(2); and
(2) The management and daily business operations of which are controlled (as defined at 13.CFR 124.106) by individuals, who meet the criteria in paragraphs (1)(i) and (ii) of this definition.
“Subsidiary” means an entity in which more than 50 percent of the entity is owned—
(1) Directly by a parent corporation; or
(2) Through another subsidiary of a parent corporation.
“Veteran-owned small business concern” means a small business concern—
(1) Not less than 51 percent of which is owned by one or more veterans(as defined at 38 U.S.C. 101(2)) or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more veterans; and
(2) The management and daily business operations of which are controlled by one or more veterans.
“Women-owned business concern” means a concern which is at least 51 percent owned by one or more women; or in the case of any publicly owned business, at least 51 percent of the its stock is owned by one or more women; and whose management and daily business operations are controlled by one or more women.
“Women-owned small business concern” means a small business concern --
(1) That is at least 51 percent owned by one or more women or, in the case of any publicly owned business, at least 51 percent of the stock of which is owned by one or more women; and
(2) Whose management and daily business operations are controlled by one or more women.
“Women-owned small business (WOSB) concern eligible under the WOSB Program (in accordance with 13 CFR part 127),” means a small business concern that is at least 51 percent directly and unconditionally owned by, and the management and daily business operations of which are controlled by, one or more women who are citizens of the United States.
(b)
(1) Annual Representations and Certifications. Any changes provided by the offeror in paragraph (b)(2) of this provision do not automatically change the representations and certifications posted on the SAMwebsite.
(2) The offeror has completed the annual representations and certifications electronically via the SAM website accessed through https://www.acquisition.gov. After reviewing the SAM database information, the offeror verifies by submission of this offer that the representation and certifications currently posted electronically at FAR 52.212- 3, Offeror Representations and Certifications—Commercial Items, have been entered or updated in the last 12 months, are current, accurate, complete, and applicable to this solicitation (including the business size standard applicable to the NAICS code referenced for this solicitation), as of the date of this offer and are incorporated in this offer by reference (see FAR 4.1201), except for paragraphs ___ . [Offeror to identify the applicable paragraphs at (c) through (p) of this provision that the offeror has completed for the purposes of this solicitation only, if any.
These amended representation(s) and/or certification(s) are also incorporated in this offer and are current, accurate, and complete as of the date of this offer. Any changes provided by the offeror are applicable to this solicitation only, and do not result in an update to the representations and certifications posted electronically on
SAM.]
(c) Offerors must complete the following representations when the resulting contract is to be performed in the United States or its outlying areas. Check all that apply.
(1) Small business concern. The offeror represents as part of its offer that it [ ___ ] is, [ ___ ] is not a small business concern.
(2) Veteran-owned small business concern. [Complete only if the offeror represented itself as a small business concern in paragraph (c)(1) of this provision.] The offeror represents as part of its offer that it [ ___ ] is, [ ___ ] is not a veteran-owned small business concern.
(3) Service-disabled veteran-owned small business concern. [Complete only if the offeror represented itself as a veteran-owned small business concern in paragraph (c)(2) of this provision.] The offeror represents as part of its offer that it [ ___ ] is, [ ___ ] is not a service-disabled veteran-owned small business concern.
(4) Small disadvantaged business concern. [Complete only if the offeror represented itself as a small business concern in paragraph (c)(1) of this provision.]The offeror represents that it [ ___ ] is, [ ___ ] is not, a small disadvantaged business concern as defined in 13 CFR 124.1002.
(5) Women-owned small business concern. [Complete only if the offeror represented itself as a small business concern in paragraph (c)(1) of this provision.]The offeror represents that it [ ___ ] is, [ ___ ] is not a women-owned small business concern.
Note: Complete paragraphs (c)(8) and (c)(9) only if this solicitation is expected to exceed the simplified acquisition threshold.
(6) WOSB concern eligible under the WOSB Program. [Complete only if the offeror represented itself as a women-owned small business concern in paragraph (c)(5) of this provision.] The offeror represents that—
(i) It [ ___ ] is, [ ___ ] is not a WOSB concern eligible under the WOSB Program, has provided all the required documents to the WOSB Repository, and no change in circumstances or adverse decisions have been issued that affects its eligibility; and
(ii) It [ ___ ] is, [ ___ ] is not a joint venture that complies with the requirements of 13 CFR part 127, and the representation in paragraph (c)(6)(i) of this provision is accurate for each WOSB concern eligible under the WOSB Program participating in the joint venture. [The offeror shall enter the name or names of the WOSB concern eligible under the WOSB Program and other small businesses that are participating in the joint venture: ___ .] Each WOSB concern eligible under the WOSB Program participating in the joint venture shall submit a separate signed copy of the WOSB representation.
(7) Economically disadvantaged women-owned small business (EDWOSB) concern. [Complete only if the offeror represented itself as a WOSB concern eligible under the WOSB Program in (c)(6) of this provision.] The offeror represents that—
(i) It [ ___ ] is, [ ___ ] is not an EDWOSB concern, has provided all the required documents to the WOSB Repository, and no change in circumstances or adverse decisions have been issued that affects its eligibility; and
(ii) It [ ___ ] is, [ ___ ] is not a joint venture that complies with the requirements of 13 CFR part 127, and the representation in paragraph (c)(7)(i) of this provision is accurate for each EDWOSB concern participating in the joint venture. [The offeror shall enter the name or names of the EDWOSB concern and other small businesses that are participating in the joint venture: ___ .] Each EDWOSB concern participating in the joint venture shall submit a separate signed copy of the EDWOSB representation.
(8) Women-owned business concern (other than small business concern). [Complete only if the offeror is a women-owned business concern and did not represent itself as a small business concern in paragraph (c)(1) of this provision.] The offeror represents that it [ ___ ] is, a women-owned business concern.
(9) Tie bid priority for labor surplus area concerns. If this is an invitation for bid, small business offerors may identify the labor surplus areas in which costs to be incurred on account of manufacturing or production (by offeror or first-tier subcontractors) amount to more than 50 percent of the contract price:
(10) HUBZone small business concern. [Complete only if the offeror represented itself as a small business concern in paragraph (c)(1) of this provision.] The offeror represents, as part of its offer, that--
(i) It [ ___ ] is, [ ___ ] is not a HUBZone small business concern listed, on the date of this representation, on the List of Qualified HUBZone Small Business Concerns maintained by the Small Business Administration, and no material changes in ownership and control, principal office, or HUBZone employee percentage have occurred since it was certified in accordance with 13 CFR part 126; and
(ii) It [ ___ ] is, [ ___ ] is not a HUBZone joint venture that complies with the requirements of 13 CFR part 126, and the representation in paragraph (c)(10)(i) of this provision is accurate for each HUBZone small business concern participating in the HUBZone joint venture. [The offeror shall enter the names of each of the HUBZone small business concerns participating in the HUBZone joint venture: ___ .] Each HUBZone small business concern participating in the HUBZone joint venture shall submit a separate signed copy of the HUBZone representation.
(11) (Complete if the offeror has represented itself as disadvantaged in paragraph (c)(4) of this provision.)
[The offeror shall check the category in which its ownership falls]:
___ Black American.
___ Hispanic American.
___ Native American (American Indians, Eskimos, Aleuts, or Native Hawaiians).
___ Asian-Pacific American (persons with origins from Burma, Thailand, Malaysia, Indonesia, Singapore, Brunei, Japan, China, Taiwan, Laos, Cambodia (Kampuchea), Vietnam, Korea, The Philippines, Republic of Palau, Republic of the Marshall Islands, Federated States of Micronesia, the Commonwealth of the Northern Mariana Islands, Guam, Samoa, Macao, Hong Kong, Fiji, Tonga, Kiribati, Tuvalu, or Nauru).
___ Subcontinent Asian (Asian-Indian) American (persons with origins from India, Pakistan, Bangladesh, Sri Lanka, Bhutan, the Maldives Islands, or Nepal).
___ Individual/concern, other than one of the preceding.
(d) Representations required to implement provisions of Executive Order 11246 --
(1) Previous contracts and compliance. The offeror represents that --
(i) It [ ___ ] has, [ ___ ] has not, participated in a previous contract or subcontract subject to the Equal Opportunity clause of this solicitation; and
(ii) It [ ___ ] has, [ ___ ] has not, filed all required compliance reports.
(2) Affirmative Action Compliance. The offeror represents that --
(i) It [ ___ ] has developed and has on file, [ ___ ] has not developed and does not have on file, at each establishment, affirmative action programs required by rules and regulations of the Secretary of Labor (41 CFR parts 60-1 and 60-2), or
(ii) It [ ___ ] has not previously had contracts subject to the written affirmative action programs requirement of the rules and regulations of the Secretary of Labor.
(e) Certification Regarding Payments to Influence Federal Transactions (31 U.S.C. 1352). (Applies only if the contract is expected to exceed $150,000.) By submission of its offer, the offeror certifies to the best of its knowledge and belief that no Federal appropriated funds have been paid or will be paid to any person for influencing or attempting to influence an officer or employee of any agency, a Member of Congress, an officer or employee of Congress or an employee of a Member of Congress on his or her behalf in connection with the award of any resultant contract. If any registrants under the Lobbying Disclosure Act of 1995 have made a lobbying contact on behalf of the offeror with respect to this contract, the offeror shall complete and submit, with its offer, OMB Standard Form LLL, Disclosure of Lobbying Activities, to provide the name of the registrants. The offeror need not report regularly employed officers or employees of the offeror to whom payments of reasonable compensation were made.
(f) Buy American Certificate. (Applies only if the clause at Federal Acquisition Regulation (FAR) 52.225-1, Buy American – Supplies, is included in this solicitation.)
(1) The offeror certifies that each end product, except those listed in paragraph (f)(2) of this provision, is a domestic end product and that for other than COTS items, the offeror has considered components of unknown origin to have been mined, produced, or manufactured outside the United States. The offeror shall list as foreign end products those end products manufactured in the United States that do not qualify as domestic end products, i.e., an end product that is not a COTS item and does not meet the component test in paragraph (2) of the definition of “domestic end product.” The terms “commercially available off-the-shelf (COTS) item,” “component,” “domestic end product,” “end product,” “foreign end product,” and “United States” are defined in the clause of this solicitation entitled “Buy American—Supplies.”
(2) Foreign End Products:
LINE ITEM NO. COUNTRY OF ORIGIN
[List as necessary]
(3) The…