This document is an amendment to Solicitation N0018924Q0448 for Rooftop Edge Railings. The purpose of this amendment is to provide questions and answers and to extend the solicitation close date. The solicitation is for safety railings that are non-penetrating to the roof structure, can withstand high winds, and include an access gate. The railings must cover approximately 215 linear feet, including 4 right angles, and be spaced 1 foot from the edge of the 16-foot tall, single-story building. The roof is a flat membrane/tar matting. The solicitation is being conducted under FAR Parts 12 and 13 for commercial items, with an associated NAICS code of 331110 and a small business size standard of 1,500 employees. The revised solicitation close date is 23-Jul-2024 at 12:00 PM.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| layout.pdf | ||
| 1.03 Minimum Requirements.pdf | ||
| 4.02 N0018924Q0448 Solicitation.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
V553224157MR65
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to provide questions and answ ers and to extend the solicitation close date. All other terms and conditions remain unchanged.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 19-Jul-2024
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X N0018924Q0448
X 9B. DATED (SEE ITEM 11)
17-Jul-2024
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
19-Jul-2024
CODE
NAVSUP FLC NORFOLK CONTRACTING
NORFOLK OFFICE
ATTN: J CLARK
1968 GILBRT STREET STE 600
NORFOLK VA 23511-3392
N00189 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N0018924Q0448
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SOLICITATION/CONTRACT FORM
The required response date/time has changed from 22-Jul-2024 12:00 PM to 23-Jul-2024 12:00 PM.
The following have been added by full text:
QUESTIONS & ANSWERS
Question 1: Do you have a drawing for the project that would show where the access gate would be located?
Answer 1: The gate location will be indicated on the attached picture of the building’s roof. The gate is indicated as a door labeled gate.
Question 2: Do you know what wind rating they are trying to meet? 130 mph? 150 mph?
Answer 2: The wind measurement rating is 130 mph.
Question 3: Do you have a layout for the railing needed?
Answer 3: See attached layout of building’s roof.
Question 4: What is the railing height requirement?
Answer 4: Railing height requirement will need to be 48 inches tall.
Question 5: Is there a parapet on the roof, what are its dimensions?
Answer 5: There is no parapet on the roof.
Question 6: What is the amount of Right Angles?
Answer 6: There would need to be 4 right angles for the corners of the space being covered.
Question 7: Is the roof accessed by a fixed ladder that we would need to leave an opening in the railing system or is access from internal stairs or hatch?
Answer 7: It is accessible by removable ladder.
Question 8: Can you confirm that the roof is a flat membrane roof?
Answer 8: It is a flat membrane roof.
Question 9: What is the height of the building?
Answer 9: It is a single story building and approximately 16 feet tall.
Quesstion 10: What is the roofing membrane type?
Answer 10: It is a built up roof / tar matting.
N0018924Q0448
(End of Summary of Changes)