ISO Office Container Specifications.xlsx
XLSX spreadsheet 13 KB Posted
- Attached to
- ISO Container Federal contract opportunity
- Solicitation number
- N0017823Q6928
About this file
This document provides specifications for modifications to a 20-foot ISO shipping container to outfit it as an office. Key details include cutting openings for a man door, air conditioning unit, and cable boots. Interior modifications involve installing insulation, plywood lining, LED lighting, electrical outlets, an HVAC unit, e-track flooring, and a built-in workbench. Exterior modifications include installing unistrut channels, entry panels, and applying paint in desert tan and interior white colors. Quality inspection and general arrangement drawings are required.
The related federal contract opportunity is a solicitation from the Department of the Navy Naval Sea Systems Command for ISO containers with an unspecified response due date. Details requested include products, quantities, delivery dates and other typical solicitation requirements.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 23Q6928_Update_Released.pdf | ||
| 23Q6928_Released.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| 20' Modified ISO Office Container Specifications |
| NEW 20' x 8'6" x 8'0" STEEL DRY FREIGHT ISO CONTAINER SB861.6 |
| Standard With (8) ISO Corner Fittings |
| FRONT END MODIFICATIONS |
| Supply & Weld In Place (2) Each Unistrut, P5500 - 1-5/8" x 2-7/16", 12 ga. Channel, |
| Solid, Full Width Horizontal Rows of Strut to Support Work Bench. |
| REAR END MODIFICATIONS (Standard Double Cargo Doors) |
| N/A, Solid walled rear end |
| CURBSIDE WALL MODIFICATIONS OR CUT OUTS |
| Cutout, Frame & Reinforce (1) Each 30" Wide X 80" High Framed, Clear Opening For Man Door. |
| Supply & Install (1) Each 30" Wide X 80" High Steel Man Door with 16" Sq. |
| Window. Includes Hardware, Fully Gasketed, Countersunk With Stainless Steel |
| Handle On Interior and Exterior |
| Cutout, Frame & Reinforce (1) Each Opening; 16" High X 26" Wide For Through |
| The Wall A/C Unit (Typ. Raid) |
| Fabricate & Install (1) Each Hinged, Gasketed Cover Plate (Typ. Raid) |
| Install additional hasp locking plate on the inside of Man Door and Frame. |
| ROADSIDE WALL MODIFICATIONS OR CUT OUTS |
| Supply & Weld In Place (2) Each Unistrut, P5500 - 1-5/8" x 2-7/16", 12 ga. Channel, |
| Solid, Full Width Horizontal Rows of Strut to Support Work Bench. |
| Cutout, Frame & Reinforce (2) Each 10" Sq. Openings, Framed with 2" Angle with |
| (4) 5/16"Ø Holes to Mount 5" Entry Panels. |
| Supply & Install (2) Each 1X1 5" Entry Panels, Valmont PN: E549. |
| Note: To be installed right above work bench half way down long wall. |
| Supply & Install (2) Each Cable Boot - 4-1/2” Boot with Ring - Black, TH Marine |
| PN: CBK-4-DP. |
| ROOF MODIFICATIONS OR CUT OUTS |
| N/A |
| FLOOR MODIFICATIONS |
| Route (3) Sections of Floor, 5"x192", to Accommodate Floor Mounted E-Track, ETrack |
| to be Flush with Finished Floor |
| Supply & Install (6) Pieces of 8' Horizontal E-Track Gray Painted, PN: HET8P-G. |
| Note: (1) Piece of E-Track to be Located Under Work Bench, (2) Pieces to be |
| Located in Common Area Approx 18" Part. Final Locations TBD. |
| Supply & Install Commercial Grade Linoleum Tile Floor Overlay |
| INTERIOR WALLS & CEILING, INSULATION & LININGS |
| 20' |
| Supply & Install SBI Standard Insulation Package In 20' Container, Which Consists |
| of 1-1/2" Foam Insulation, 3/8" Plywood With White Textured Plastic Lining. |
| Thermal Value Approx. R10. |
| INTERIOR PARTITION WALLS & DOORS |
| N/A |
| HEATING, VENTILATION, & AIR CONDITIONING SYSTEMS (HVAC) |
| Supply (1) Each Window Air Conditioner w/Heat. Cool/Heat Operation Mode, |
| Electric Heating Method, 12,000 BtuH Cooling, 10,700 BtuH Heating, 230VAC, |
| 11.2 CEER, Nema 6-20P Configuration 6 Ft. Power Cord, 4.9 Amps, 1062 Watts, 3.5 |
| lb./hr. Dehumidification, R-410A Refrigerant, 25-15/16" Wide, 29" Deep, 15-15/16" |
| High. Friedrich Model # KES12A33. |
| DUCT WORK & FIRE DAMPERS |
| N/A |
| ELECTRICAL & LIGHTING SYSTEMS |
Supply & Install (1) Each Exterior Mounted 30 Amp Power Inlet Box.
30 Amp 4-wire L14-30 Style Power Inlet Note: Located Curb Side Wall. Power Inlet Configuration is TBD Based on Customers Available Power Plug.
Supply & Install (1) Each Load Center, 100 Amps, 120/240VAC Voltage. Note:
Load Center to Include 30 Amp Main Breaker Circuit 1- LED Lighting - Supply & Install (2) 4' Long, 7,150 Lumens, 65 Watt 120-277 VAC, LED Light Fixture. IP65 Rated. PN: VTS-7CS-40K-U. Budget Provides (1) Light Switch & Breaker.
Circuit 2 - Supply & Install (2) Each Duplex Receptacles, Nema 5-15R, 15 Amp Breaker. Note: (1) to be GFCI and (1) to be Standard Commercial.
Circuit 3 - Supply & Install (2) Each Duplex Receptacles, Nema 5-15R, 15 Amp Breaker. Note: (1) to be GFCI and (1) to be Standard Commercial.
Circuit 4 - HVAC - Supply & Install (1) Each Dedicated Receptacle, Nema 6-20R, 20 Amp Breaker.
Note: Receptacle to be installed beside HVAC reinforced cutout.
Supply & Install (1) Each Grounding Stud to Power Entry Location. Note: Standard With All Electrical Packages.
| FURNITURE & BUILT-IN SHELVES & CABINETS |
| Supply & Install the Following Vidmar Items, Consisting of:Ref. Q-117808.1 |
| Install 16' work bench along left long wall and across the closed end of container. |
| (2) HT96 HARDWOOD TOP-96 X 30 X 1 3/4 |
| (1) HT84 HARDWOOD TOP-84 X 30 X 1 3/4 |
| (1) SP SPLICE PLATE KIT |
| (8) BL1551 BENCH LEG ST 155 |
| PAINTING SPECIFICATIONS & MARKINGS - INTERIOR & EXTERIOR: |
| 20' Container Blast Welds SSPC-SP10 and Brush Blast Needed Areas |
| New Exterior Industrial Marine Paint On Walls & Roof - Color:Desert Tan, #33446 |
| 20' Container Paint Preparation & Cleaning |
| 20' Container Primer and Top Coat: |
| 66% Zinc Primer |
| Polyzen Top Coat |
| New Interior Industrial Marine Paint On Walls & Ceiling - Color:Interior White for Insulated Products, #17925 |
| 20' Container Paint Preparation & Cleaning |
| 20' Container Primer and Top Coat: |
| 66% Zinc Primer |
| Polyzen Top Coat |
| Markings: |
| Original Unit Numbers |
| Supply & Install Manufactured By Sea Box ID Plate. Note: Not for Overseas Transport. |
| Marking package Type: |
| Overseas Shipping Marking Package; Includes Tare & Payload Weights |
| QUALITY INSPECTION, TESTING, DATA, DRAWINGS AND CUSTOMER DESIGN & REVIEW MEETINGS |
| Quality Check All Features |
| General Arrangement Drawings |