Minimum Parameters:
1) -55C to 150C operating temperature range
2) Surface mount for PCB application
3) Dielectric rating of 1500 VAC, 1s
4) Primary inductance of 25uH – 45uH
5) Primary resistance < 3 ohms
6) Secondary inductance of 1mH – 2mH
7) Secondary resistance < 55 ohms
8) Leakage inductance < 20uH
9) Part thickness < 0.12 inches
10) Part board area < 0.16 square inches