Minimum Parameters:

1) -55C to 150C operating temperature range

2) Surface mount for PCB application

3) Dielectric rating of 1500 VAC, 1s

4) Primary inductance of 25uH – 45uH

5) Primary resistance < 3 ohms

6) Secondary inductance of 1mH – 2mH

7) Secondary resistance < 55 ohms

8) Leakage inductance < 20uH

9) Part thickness < 0.12 inches

10) Part board area < 0.16 square inches