OFM Sensor Specifications The sensor that will be used must meet the requirements in Table 1: Sensor Requirements.
| Frequency Range, GHz |
| 0.02 – 18 |
| Maximum input power (RF), dBm |
| ≥ 15 |
| Number of full bandwidth selectable input antenna ports |
| ≥ 3 |
| Noise Figure |
| ≤ 20 dB across the entire band |
| Instantaneous Bandwidth, MHz |
| ≥ 100 |
| Tuning Resolution, Hz |
| ≤ 10 |
| Sweep Duration for 18 GHz at 1 MHz RBW, sec |
| ≤ 0.5 |
| Dynamic Range (single 100 MHz measurement), dB |
| ≥ 50 |
| Dynamic Range (between multiple 100 MHz measurements; e.g. internal AGC), dB |
| ≥ 80 |
Must be network addressable
Must autonomously conduct full band spectrum captures and threshold violation measurements
| Dimensions (HxLxW), in |
| ≤ 6x12x12 |
| Weight (as configured for outdoor operation), lbs |
| ≤ 15 |
| Power Input (Main supply), W |
| ≤ 100 |
| Operating Temperature, °F |
| ≤ -10 to ≥ 125 |
| Ingress Protection, IPXX |
| Solid Particle: 6; Liquid Ingress: ≥ 6 |
Must include 2 year software support
System must include all mounting hardware and power cords
Table 1: Sensor Requirements