MINIMUM TECHNICAL SPECIFICATIONS

1. The system shall be 19" W x 21" D x 7" H or smaller.

2. The system shall weigh less than 60 lb.

3. The system shall meet the following environmental specifications:

Operating Temp: 0° to +50° C Storage Temp: –40° to +85° C Relative Humidity: 5 to 95%, non-condensing Operating Shock: 15 g max. (11 msec, half sine wave) Operating Vibration: 10 to 20 Hz: 0.02 inch peak, 20 to 500 Hz: 1.4 g peak acceleration

4. The system shall meet the following sample rate requirements:

Sample rates up to 3.6 GHz in Dual-channel mode

Sample rates up to 1.8 GHz in Quad-channel mode

5. The system shall meet the following RF recording requirements:

Capable of recording RF/IF frequencies to 1.75 GHz in dual-channel mode

Capable of recording RF/IF frequencies to 2.8 GHz in quad-channel mode

12-bit A/D, with 16- and 8-bit packing modes

Real-time aggregate recording rates of at least 4.8 GB/sec per pair of channels

6. The system shall meet the following coherent recording requirements:

Capable of coherent recording in dual-channel mode

Capable of coherent recording in quad-channel mode

Capable of operating without inter-channel jitter

7. The system shall be built on the following platform:

Windows® 7 Professional workstation with high performance Intel® CoreTM i7 processor

8. The system shall have the following storage facility:

At least 61 terabytes of SSD storage to NTFS RAID solid-state disk array with selectable RAID levels of 0, 1, 5 and 6

9. The system shall contain a graphical user interface with signal analysis tools.

These tools shall include a virtual oscilloscope, a virtual spectrum analyzer and a spectrogram display.

10. The system shall include a C-callable API for integration.

11. The recorded files shall include file headers include time stamping and recording parameters.

12. The system shall have a facility to allow the loading of a trigger linked list table for the purpose of recording signals using a custom gating scheme.

The recorder shall be capable of setting delay, trigger length and number of times to repeat each link in a list.

The trigger shall be synchronous for all channel configurations.