53-4028-16_DataRecorderSpec.docx
DOCX document 15 KB Posted
- Attached to
- Data Recorder Federal contract opportunity
- Solicitation number
- N00173-16-Q-0529
About this file
Minimum Technical Specification
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MINIMUM TECHNICAL SPECIFICATIONS
1. The system shall be 19" W x 21" D x 7" H or smaller.
2. The system shall weigh less than 60 lb.
3. The system shall meet the following environmental specifications:
Operating Temp: 0° to +50° C Storage Temp: –40° to +85° C Relative Humidity: 5 to 95%, non-condensing Operating Shock: 15 g max. (11 msec, half sine wave) Operating Vibration: 10 to 20 Hz: 0.02 inch peak, 20 to 500 Hz: 1.4 g peak acceleration
4. The system shall meet the following sample rate requirements:
Sample rates up to 3.6 GHz in Dual-channel mode
Sample rates up to 1.8 GHz in Quad-channel mode
5. The system shall meet the following RF recording requirements:
Capable of recording RF/IF frequencies to 1.75 GHz in dual-channel mode
Capable of recording RF/IF frequencies to 2.8 GHz in quad-channel mode
12-bit A/D, with 16- and 8-bit packing modes
Real-time aggregate recording rates of at least 4.8 GB/sec per pair of channels
6. The system shall meet the following coherent recording requirements:
Capable of coherent recording in dual-channel mode
Capable of coherent recording in quad-channel mode
Capable of operating without inter-channel jitter
7. The system shall be built on the following platform:
Windows® 7 Professional workstation with high performance Intel® CoreTM i7 processor
8. The system shall have the following storage facility:
At least 61 terabytes of SSD storage to NTFS RAID solid-state disk array with selectable RAID levels of 0, 1, 5 and 6
9. The system shall contain a graphical user interface with signal analysis tools.
These tools shall include a virtual oscilloscope, a virtual spectrum analyzer and a spectrogram display.
10. The system shall include a C-callable API for integration.
11. The recorded files shall include file headers include time stamping and recording parameters.
12. The system shall have a facility to allow the loading of a trigger linked list table for the purpose of recording signals using a custom gating scheme.
The recorder shall be capable of setting delay, trigger length and number of times to repeat each link in a list.
The trigger shall be synchronous for all channel configurations.
File details come from the government source that posted it. Updated .