1301043773

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

Amendment to incorporate addition of N9952B-235 Pre-Amplifier, in CLIN 0001 minimum specifications.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 3

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 17-Nov-2022

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X N0016723Q0013

X 9B. DATED (SEE ITEM 11)

04-Nov-2022

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

17-Nov-2022

CODE

NAVAL SURFACE WARFARE CENTER CARDEROCK

MICHAEL S. BRODIE

757-478-1118 MICHAEL.S.BRODIE7.CIV@US.NAVY.MI

904 CORPORATE LANE

CHESAPEAKE VA 23320

N00167 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

N0016723Q0013

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 1449 - CONTINUATION SHEET

SOLICITATION/CONTRACT FORM

The required response date/time has changed from 14-Nov-2022 04:00 PM to 22-Nov-2022 12:00 PM.

SUPPLIES OR SERVICES AND PRICES

CLIN 0001

The CLIN extended description has changed from:

FieldFox 50 GHz Microwave Analyzer (N9952B)Includes parts: • N9952B-010 Vector Network Analyzer Time Domain• N9952B-208 USB Power Sensor Measurements vs. Freq• N9952B-210 Vector Network Analyzer Trans/Ref• N9952B-211 Vector Network Analyzer full 2-port S-parameters• N9952B-212 1-port mixed mode S-parameters• N9952B-215 TDR cable measurements• N9952B-233 Spec Analyzer• N9952B 236 Interference analyzer and spectrogram• N9952B-302 USB power sensor support• N9952B-309 DC Bias Variable-Voltage Control• N9952B-310 Built-in power meter• N9952B-330 Pulse Measurements • N9952B-350 Real-time Spectrum Analyzer• N9952B-351 I/Q Analyzer

To:

FieldFox 50 GHz Microwave Analyzer (N9952B)Includes parts: • N9952B-010 Vector Network Analyzer Time Domain• N9952B-208 USB Power Sensor Measurements vs. Freq• N9952B-210 Vector Network Analyzer Trans/Ref• N9952B-211 Vector Network Analyzer full 2-port S-parameters• N9952B-212 1-port mixed mode S-parameters• N9952B-215 TDR cable measurements• N9952B-233 Spec Analyzer• N9952B-235 Pre-Amplifier• N9952B 236 Interference analyzer and spectrogram• N9952B-302 USB power sensor support• N9952B-309 DC Bias Variable-Voltage Control• N9952B-310 Built-in power meter• N9952B-330 Pulse Measurements • N9952B-350 Real-time Spectrum Analyzer• N9952B-351 I/Q Analyzer

The following have been modified:

Specifications Keysight Fieldfox

The device has to operate reliably and consistently as both a spectrum analyzer and a network analyzer with precision from 100 MHz to 50 GHz span of frequency, it has to work as Vector Network analyzer in time domain, it needs to have USB power sensor measurement vs frequency, Vector network analyzer transmission/reflection, Vector analyzer full 2 port S-parameters, 1 port mixed-mode S-parameters, and Time Domain Reflectometer RF measurements.

Includes parts:

N9952B-010 Vector Network Analyzer Time Domain, N9952B-208 USB Power Sensor Measurements vs. Freq, N9952B-210 Vector Network Analyzer Trans/Ref, N0016723Q0013

N9952B-211 Vector Network Analyzer full 2-port S-parameters, N9952B-212 1-port mixed mode S-parameters, N9952B-215 TDR cable measurements, N9952B-233 Spec Analyzer, N9952B-235 Pre-Amplifier, N9952B 236 Interference analyzer and spectrogram, N9952B-302 USB power sensor support, N9952B-309 DC Bias Variable-Voltage Control, N9952B-310 Built-in power meter, N9952B-330 Pulse Measurements, N9952B-350 Real-time Spectrum Analyzer, N9952B-351 I/Q Analyzer.

Additional requirements:

- 5-year KeysightCare technical support (R-55D-001-5ZU) [upgrade from standard 3-year plan]

- 3 year calibration plan (R-50C-011-3)

- Standard mechanical calibration kit, DC to 50 GHz, 2.4mm (return to Keysight warranty-1 year) (85056A)

(end of text)

(End of Summary of Changes)